| Output |
2 Solid State
|
|---|
| Number of outputs, safety related, undelayed, with contact |
0
|
|---|---|
| Number of outputs, safety related, delayed, with contact |
0
|
| Number of outputs, signalling function, undelayed, with contact |
0
|
| Number of outputs, safety related, undelayed, semiconductors |
2
|
| Number of outputs, safety related, delayed, semiconductors |
0
|
| Number of outputs, signalling function, undelayed, semiconductors |
1
|
| Number of outputs, signalling function, delayed, semiconductors |
0
|
| With start input |
No
|
| With muting function |
No
|
| Voltage type for actuating |
DC
|
| Rated control supply voltage at DC |
24 V
|
| Model |
Basic device
|
| Type of electric connection |
Screw connection
|
| Evaluation inputs |
Other
|
| Power consumption |
2 W
|
| Configurable logic |
AND/OR
|
| Continuous safety output current |
14, 24: 1.5 A each, 34, 44: 0.5 A each
|
| Wire size |
0.2 to 2.5 mm²
|
| Number of outputs, signalling function, delayed, with contact |
0
|
| With feedback circuit |
Yes
|
| Suitable for monitoring of magnetic switches |
Yes
|
| Suitable for monitoring of proximity switches |
Yes
|
| Suitable for monitoring of emergency-stop circuits |
Yes
|
| Suitable for monitoring of optoelectronic protection equipment |
Yes
|
| Suitable for monitoring of position switches |
Yes
|
| Suitable for monitoring of tactile sensors |
Yes
|
| Suitable for monitoring of valves |
Yes
|
| Surge auxillary output current duration, max |
5 ms
|
| Continuous auxiliary output current |
50 mA
|
| Surge auxiliary output current |
700 mA
|
| Other input |
SWS input
|
| Other output |
SWS output
|
| Operating voltage |
20.4 V
|
| SIL according to IEC 61508 |
3
|
|---|---|
| With approval according to UL |
Yes
|
| Stop category according to IEC 60204 |
0
|
| Performance level according to EN ISO 13849-1 |
Level e
|
| Type of safety according to IEC 61496-1 |
4
|
| With approval for TUV |
Yes
|
| With detachable clamps |
Yes
|
|---|---|
| Rated control supply voltage at AC 50 Hz |
0 V
|
| Rated control supply voltage at AC 60 Hz |
0 V
|
| Vibration |
10...55 Hz, 0.35 mm
|
| Shock |
Shock proof, operating: 10 G, 16 ms
|
| Release-delay |
0 s
|
| Rail mounting possible |
Yes
|
| Enclosure protection |
IP40 (NEMA 1)
|
| MTTFd |
484 year
|
|---|---|
| T cycle |
8/28.8 (h/s)
|
| Mission time |
20 year
|
| Hours of operation |
24 h
|
| DC avg. (EN ISO 13849-1) |
99 %
|
| Days of operation |
365 dbays
|
| Performance level |
Up to e
|
| Evaluation input |
SWS input
|
| Operating temperature |
-5 °C
|
|---|---|
| Relative humidity |
90%
|
| Height |
119.4 mm
|
|---|---|
| Width |
22.5 mm
|
| Depth |
113.6 mm
|
| 基本信息 | 出版 |
|---|---|
| Product Cutsheet | -- |
| Link to Online Catalog | -- |
| Link to Application Examples Brochure | SAFETY-WD001 |
| Link to Application and Wiring Diagram Brochure | SAFETY-WD001 |
| Link to Connection Diagrams | -- |
| 安装说明 | 出版 |
|---|---|
| 440r-in085_-en-p | 440R-IN085 |
| 用户手册 | 出版 |
|---|---|
| 440r-um013_-en-p | 440R-UM013 |
- Korean KC
- Kosha Approval
截至 2026-01-31,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。
| 技术说明 |
|---|
技术规格
| Output |
2 Solid State
|
|---|
| Number of outputs, safety related, undelayed, with contact |
0
|
|---|---|
| Number of outputs, safety related, delayed, with contact |
0
|
| Number of outputs, signalling function, undelayed, with contact |
0
|
| Number of outputs, safety related, undelayed, semiconductors |
2
|
| Number of outputs, safety related, delayed, semiconductors |
0
|
| Number of outputs, signalling function, undelayed, semiconductors |
1
|
| Number of outputs, signalling function, delayed, semiconductors |
0
|
| With start input |
No
|
| With muting function |
No
|
| Voltage type for actuating |
DC
|
| Rated control supply voltage at DC |
24 V
|
| Model |
Basic device
|
| Type of electric connection |
Screw connection
|
| Evaluation inputs |
Other
|
| Power consumption |
2 W
|
| Configurable logic |
AND/OR
|
| Continuous safety output current |
14, 24: 1.5 A each, 34, 44: 0.5 A each
|
| Wire size |
0.2 to 2.5 mm²
|
| Number of outputs, signalling function, delayed, with contact |
0
|
| With feedback circuit |
Yes
|
| Suitable for monitoring of magnetic switches |
Yes
|
| Suitable for monitoring of proximity switches |
Yes
|
| Suitable for monitoring of emergency-stop circuits |
Yes
|
| Suitable for monitoring of optoelectronic protection equipment |
Yes
|
| Suitable for monitoring of position switches |
Yes
|
| Suitable for monitoring of tactile sensors |
Yes
|
| Suitable for monitoring of valves |
Yes
|
| Surge auxillary output current duration, max |
5 ms
|
| Continuous auxiliary output current |
50 mA
|
| Surge auxiliary output current |
700 mA
|
| Other input |
SWS input
|
| Other output |
SWS output
|
| Operating voltage |
20.4 V
|
| SIL according to IEC 61508 |
3
|
|---|---|
| With approval according to UL |
Yes
|
| Stop category according to IEC 60204 |
0
|
| Performance level according to EN ISO 13849-1 |
Level e
|
| Type of safety according to IEC 61496-1 |
4
|
| With approval for TUV |
Yes
|
| With detachable clamps |
Yes
|
|---|---|
| Rated control supply voltage at AC 50 Hz |
0 V
|
| Rated control supply voltage at AC 60 Hz |
0 V
|
| Vibration |
10...55 Hz, 0.35 mm
|
| Shock |
Shock proof, operating: 10 G, 16 ms
|
| Release-delay |
0 s
|
| Rail mounting possible |
Yes
|
| Enclosure protection |
IP40 (NEMA 1)
|
| MTTFd |
484 year
|
|---|---|
| T cycle |
8/28.8 (h/s)
|
| Mission time |
20 year
|
| Hours of operation |
24 h
|
| DC avg. (EN ISO 13849-1) |
99 %
|
| Days of operation |
365 dbays
|
| Performance level |
Up to e
|
| Evaluation input |
SWS input
|
| Operating temperature |
-5 °C
|
|---|---|
| Relative humidity |
90%
|
| Height |
119.4 mm
|
|---|---|
| Width |
22.5 mm
|
| Depth |
113.6 mm
|
图纸
文档
|
Product Cutsheet
基本信息
-- |
|
Link to Online Catalog
基本信息
-- |
|
Link to Application Examples Brochure
基本信息
SAFETY-WD001 |
|
Link to Application and Wiring Diagram Brochure
基本信息
SAFETY-WD001 |
|
Link to Connection Diagrams
基本信息
-- |
|
440r-in085_-en-p
安装说明
440R-IN085 |
|
440r-um013_-en-p
用户手册
440R-UM013 |
| 基本信息 | 出版 |
|---|---|
| Product Cutsheet | -- |
| Link to Online Catalog | -- |
| Link to Application Examples Brochure | SAFETY-WD001 |
| Link to Application and Wiring Diagram Brochure | SAFETY-WD001 |
| Link to Connection Diagrams | -- |
| 安装说明 | 出版 |
| 440r-in085_-en-p | 440R-IN085 |
| 用户手册 | 出版 |
| 440r-um013_-en-p | 440R-UM013 |
认证
- Korean KC
- Kosha Approval
截至 2026-01-31,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。
配件
替代产品
技术说明
| 技术说明 |
|---|
Copyright ©2026 Rockwell Automation, Inc.