281D-F12Z-10C-CR-3FR

ArmorStart Reversing Starter

PrintPrint
打印
EmailEmail
共享
Product RegistrationProduct Registration
二维码
Allen-Bradley 281D-F12Z-10C-CR-3FR product image
Allen-Bradley 281D-F12Z-10C-CR-3FR product image
Allen-Bradley 281D-F12Z-10C-CR-3FR product image
生命周期状态: 停止
ErrorsErrors
Rockwell Automation announces that as of October 08, 2024, the ArmorStart Reversing Starter will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期: October 08, 2024 替代类别: Engineering Replacement
产品概览
提供多种维修方式
生命周期状态: 停止
ErrorsErrors
Rockwell Automation announces that as of October 08, 2024, the ArmorStart Reversing Starter will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期: October 08, 2024 替代类别: Engineering Replacement
产品概览
提供多种维修方式
添加到BoM
  • 寻找支持
技术规格
基本信息
Mechanical
Electrical
Environmental
Construction
图纸
文档
配件
替代产品
技术说明
Product Family
ArmorStart
Degree of protection (IP)
IP67
Shipping weight, approx
10.4 kg
Shock
Opsal: 15 G
Wire strip length
Power and ground terminals: 0.35 in (9 mm)
Vibration
Opsal, 1 G, 0.15 mm (0.006 in) displacement
Tightening torque
Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal)
Mechanical life operations
Output ratings (sourced from control circuit): 50000000 ops (18K ops/hr)
Disconnect lock out
Recommend 8 mm (5/16 in) lock shackle or hasp. The hasp should not exceed 8 mm (5/16 in) when closed.
Baud rates
500 kbps
Overload selection current range
1.1 A
Communication
DeviceNet
Short circuit protection
10 A rated device
DeviceNet input current surge
15 A for 250 µs
DeviceNet input current
364mA @ 11V DC - 4.0 W
Total with maximum sensor inputs (4)
367mA @ 24V DC - 8.8 W
Overvoltage category
Control circuit: III per IEC
Rated operational current
Power circuit: 5.5 A maximum
Product type
Reversing starter
Rated impulse voltage
Power circuit: 6 kV
DeviceNet supply voltage rating
24V DC nominal
Control (pick up)
Power requirements: 0.71 A without HOA
Control (hold in)
Power requirements: 0.063 A without HOA
Rated input operation voltage
24V DC
Input OFF-state current
<1.5 mA
Input OFF-state voltage
0...5V DC
Input ON-state voltage
10...26V DC
Distance, max
500 m (1630 ft) @ 125 kbps
Operating frequency
Power circuit: 50/60 Hz
Input ON-state current
7.2mA @ 24V DC
Option 1
HAND-OFF-AUTO selector keypad with FORWARD and REVERSE
Number of contacts
Output rating- sourced from control circuit: 2
Voltage status only
11...25V DC from DeviceNet
Outputs current (2) 1 A max. each
External devices powered by control voltage: 2 A without HOA
Trip rating
120% of full load current (FLC) setting
Total control power (pick up) with max outputs
External devices powered by control voltage: 73 W with HOA
Total control power (hold in) with max outputs
External devices powered by control voltage: 58 W with HOA
Input compatibility
IEC 1133 Type 1+ per IEC
Application in industrial area permitted (SCPD list)
Size per NFPA 70 (NEC) or NFPA 79 for group motor applications
Rated output operation voltage
Sourced from control circuit: 30V DC
Insulation voltage
Power circuit: rated 600V
Dielectric withstand
Power circuit: 2500V AC per IEC
Type of contacts
Output rating- sourced from control circuit: normally open (NO)
Current available
50 mA maximum per input, 200 mA total
Type of control circuit
Output rating- sourced from control circuit: electromechanical relay
Conventional thermal current (Ith)
Output rating- sourced from control circuit: total of both outputs ≤2 A
Circuit breaker operational current rating, max
60A @ 480V (with gland type: CR or DR)
RMS symmetrical amperes
65 kA @ 480Y/277V (with gland type: RR)
Rated operation voltage
Power circuit: 200...575V
3-phase power/motor cable connection
Conduit entrance with motor cable
Input filter - software selectable
Settable from 0...64 ms in 1 ms increments (ON to OFF)
Kind of current
Output ratings (sourced from control circuit): AC/DC (not to be used as an AC/DC power supply)
Fuse operational current rating, max
Time delay: 20 A @ 480Y/277V (with gland type: RR)
Total control power (pick up)
Power requirements: 21 W with HOA
Total control power (hold in)
Power requirements: 5.6 W with HOA
Trip class
Class 10, 15, 20
Operational power rating
Reversing starters - IP67/Type 4/12: 3Hp @ 575V AC, 60 Hz
Number of digital inputs
4
Number of digital outputs
2
Supporting protocol for DeviceNet
Yes
Application in industrial area permitted
Yes
Mains frequency
50/60 Hz
Short circuit protection device performance (SCPD) type
Type 1
Short circuit rating
30 kA
Disconnect
Motor disconnect
Connection type
Quick disconnects
Utilization category
Power circuit: AC-3 per IEC
External devices powered by DeviceNet
50 mA - total 200 mA
Electrical life cycle
Output ratings (sourced from control circuit): 100000 ops (1.8K ops/hr)
Altitude
2000 m
Operating temperature
-20 °C
Storage and transportation temperature
-25 °C
Humidity
5...95% (noncondensing)
Protection against shock
Power circuit: IP2X per IEC
Surge transient
1 kV L-L, 2 kV L-N (earth)
Radiated emissions
Class A, Group 1, equivalent to C2 emissions
Conducted radio frequency emissions
Class A
Radio frequency electromagnetic field
10 V/m
Degree of protection (NEMA)
4
Pollution degree
3
Fast transient
2 kV
Electrostatic discharge
4 kV contact and 8 kV air
Height, approx
287.5 mm
Depth, approx
Motor connection 243 mm (9.57 in) M35 cordset
Wire size
Power and ground terminals: #16... AWG per UL/NEMA (primary/sary terminal)
Width, approx
351 mm
Number of poles
3
图纸
3D STEP Model (STP) 下载 (ZIP)
产品图纸 图纸 (DWG)
图纸
3D STEP Model (STP) 下载 (ZIP)
产品图纸 图纸 (DWG)
基本信息 出版
Repair Parts List --
External Connections and OL Curves --
Specifications Sheet --
Product Cutsheet --
Dimension Sheet (PDF) --
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
每页项目:
1-1 关于 1
每页项目:
1-1 关于 1
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
技术规格
Product Family
ArmorStart
Degree of protection (IP)
IP67
Shipping weight, approx
10.4 kg
Shock
Opsal: 15 G
Wire strip length
Power and ground terminals: 0.35 in (9 mm)
Vibration
Opsal, 1 G, 0.15 mm (0.006 in) displacement
Tightening torque
Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal)
Mechanical life operations
Output ratings (sourced from control circuit): 50000000 ops (18K ops/hr)
Disconnect lock out
Recommend 8 mm (5/16 in) lock shackle or hasp. The hasp should not exceed 8 mm (5/16 in) when closed.
Baud rates
500 kbps
Overload selection current range
1.1 A
Communication
DeviceNet
Short circuit protection
10 A rated device
DeviceNet input current surge
15 A for 250 µs
DeviceNet input current
364mA @ 11V DC - 4.0 W
Total with maximum sensor inputs (4)
367mA @ 24V DC - 8.8 W
Overvoltage category
Control circuit: III per IEC
Rated operational current
Power circuit: 5.5 A maximum
Product type
Reversing starter
Rated impulse voltage
Power circuit: 6 kV
DeviceNet supply voltage rating
24V DC nominal
Control (pick up)
Power requirements: 0.71 A without HOA
Control (hold in)
Power requirements: 0.063 A without HOA
Rated input operation voltage
24V DC
Input OFF-state current
<1.5 mA
Input OFF-state voltage
0...5V DC
Input ON-state voltage
10...26V DC
Distance, max
500 m (1630 ft) @ 125 kbps
Operating frequency
Power circuit: 50/60 Hz
Input ON-state current
7.2mA @ 24V DC
Option 1
HAND-OFF-AUTO selector keypad with FORWARD and REVERSE
Number of contacts
Output rating- sourced from control circuit: 2
Voltage status only
11...25V DC from DeviceNet
Outputs current (2) 1 A max. each
External devices powered by control voltage: 2 A without HOA
Trip rating
120% of full load current (FLC) setting
Total control power (pick up) with max outputs
External devices powered by control voltage: 73 W with HOA
Total control power (hold in) with max outputs
External devices powered by control voltage: 58 W with HOA
Input compatibility
IEC 1133 Type 1+ per IEC
Application in industrial area permitted (SCPD list)
Size per NFPA 70 (NEC) or NFPA 79 for group motor applications
Rated output operation voltage
Sourced from control circuit: 30V DC
Insulation voltage
Power circuit: rated 600V
Dielectric withstand
Power circuit: 2500V AC per IEC
Type of contacts
Output rating- sourced from control circuit: normally open (NO)
Current available
50 mA maximum per input, 200 mA total
Type of control circuit
Output rating- sourced from control circuit: electromechanical relay
Conventional thermal current (Ith)
Output rating- sourced from control circuit: total of both outputs ≤2 A
Circuit breaker operational current rating, max
60A @ 480V (with gland type: CR or DR)
RMS symmetrical amperes
65 kA @ 480Y/277V (with gland type: RR)
Rated operation voltage
Power circuit: 200...575V
3-phase power/motor cable connection
Conduit entrance with motor cable
Input filter - software selectable
Settable from 0...64 ms in 1 ms increments (ON to OFF)
Kind of current
Output ratings (sourced from control circuit): AC/DC (not to be used as an AC/DC power supply)
Fuse operational current rating, max
Time delay: 20 A @ 480Y/277V (with gland type: RR)
Total control power (pick up)
Power requirements: 21 W with HOA
Total control power (hold in)
Power requirements: 5.6 W with HOA
Trip class
Class 10, 15, 20
Operational power rating
Reversing starters - IP67/Type 4/12: 3Hp @ 575V AC, 60 Hz
Number of digital inputs
4
Number of digital outputs
2
Supporting protocol for DeviceNet
Yes
Application in industrial area permitted
Yes
Mains frequency
50/60 Hz
Short circuit protection device performance (SCPD) type
Type 1
Short circuit rating
30 kA
Disconnect
Motor disconnect
Connection type
Quick disconnects
Utilization category
Power circuit: AC-3 per IEC
External devices powered by DeviceNet
50 mA - total 200 mA
Electrical life cycle
Output ratings (sourced from control circuit): 100000 ops (1.8K ops/hr)
Altitude
2000 m
Operating temperature
-20 °C
Storage and transportation temperature
-25 °C
Humidity
5...95% (noncondensing)
Protection against shock
Power circuit: IP2X per IEC
Surge transient
1 kV L-L, 2 kV L-N (earth)
Radiated emissions
Class A, Group 1, equivalent to C2 emissions
Conducted radio frequency emissions
Class A
Radio frequency electromagnetic field
10 V/m
Degree of protection (NEMA)
4
Pollution degree
3
Fast transient
2 kV
Electrostatic discharge
4 kV contact and 8 kV air
Height, approx
287.5 mm
Depth, approx
Motor connection 243 mm (9.57 in) M35 cordset
Wire size
Power and ground terminals: #16... AWG per UL/NEMA (primary/sary terminal)
Width, approx
351 mm
Number of poles
3
图纸
图纸
3D STEP Model (STP) 下载 (ZIP)
产品图纸 图纸 (DWG)
图纸
3D STEP Model (STP) 下载 (ZIP)
产品图纸 图纸 (DWG)
文档
Repair Parts List 基本信息
--
External Connections and OL Curves 基本信息
--
Specifications Sheet 基本信息
--
Product Cutsheet 基本信息
--
Dimension Sheet (PDF) 基本信息
--
基本信息 出版
Repair Parts List --
External Connections and OL Curves --
Specifications Sheet --
Product Cutsheet --
Dimension Sheet (PDF) --
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
配件
每页项目:
1-1 关于 1
替代产品
每页项目:
1-1 关于 1
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
Loading
寻找最近经销商
请联系您在{0}的经销商
更改位置
EmailEmail
PhonePhone
寻找合作伙伴
ArmorStart Reversing Starter
CloseClose
281D-F12Z-10C-CR-3FR
关闭
打印
Chevron LeftChevron Left
Allen-Bradley 281D-F12Z-10C-CR-3FR product image
Chevron LeftChevron Left
Allen-Bradley 281D-F12Z-10C-CR-3FR product image
Allen-Bradley 281D-F12Z-10C-CR-3FR product image
电话:
呼叫
Rockwell Automation Home
Copyright ©2026 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页
  2. Chevron LeftChevron Left 产品
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose