280D-F12B-10C-CRW
ArmorStart Starter
Rockwell Automation announces that as of October 08, 2024, the ArmorStart Starter will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
October 08, 2024
替代类别:
Engineering Replacement
Rockwell Automation announces that as of October 08, 2024, the ArmorStart Starter will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
October 08, 2024
替代类别:
Engineering Replacement
| Communications |
DeviceNet
|
|---|---|
| Product Family |
ArmorStart
|
| Degree of protection (IP) |
IP67
|
|---|---|
| Shipping weight, approx |
10.4 kg
|
| Shock |
Opsal: 15 G
|
| Wire strip length |
Power and ground terminals: 0.35 in (9 mm)
|
| Vibration |
Opsal, 1 G, 0.15 mm (0.006 in) displacement
|
| Tightening torque |
Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal)
|
| Mechanical life operations |
Output ratings (sourced from control circuit): 50000000 ops (18K ops/hr)
|
| Disconnect lock out |
Recommend 8 mm (5/16 in) lock shackle or hasp. The hasp should not exceed 8 mm (5/16 in) when closed.
|
| Baud rates |
500 kbps
|
|---|---|
| Overload selection current range |
1.1 A
|
| Communication |
DeviceNet
|
| Short circuit protection |
10 A rated device
|
| DeviceNet input current surge |
15 A for 250 µs
|
| DeviceNet input current |
364mA @ 11V DC - 4.0 W
|
| Total with maximum sensor inputs (4) |
367mA @ 24V DC - 8.8 W
|
| Overvoltage category |
Control circuit: III per IEC
|
| Rated operational current |
Power circuit: 5.5 A maximum
|
| Product type |
Full voltage starter
|
| Rated impulse voltage |
Power circuit: 6 kV
|
| DeviceNet supply voltage rating |
24V DC nominal
|
| Control (pick up) |
Power requirements: 0.292 A without HOA
|
| Control (hold in) |
Power requirements: 0.038 A without HOA
|
| Input OFF-state current |
<1.5 mA
|
| Input OFF-state voltage |
0...5V DC
|
| Input ON-state voltage |
10...26V DC
|
| Distance, max |
500 m (1630 ft) @ 125 kbps
|
| Operating frequency |
Power circuit: 50/60 Hz
|
| Input ON-state current |
7.2mA @ 24V DC
|
| Option 1 |
Status only keypad
|
| Number of contacts |
Output rating- sourced from control circuit: 2
|
| Voltage status only |
11...25V DC from DeviceNet
|
| Outputs current (2) 1 A max. each |
External devices powered by control voltage: 2 A without HOA
|
| Trip rating |
120% of full load current (FLC) setting
|
| Total control power (pick up) with max outputs |
External devices powered by control voltage: 579VA with HOA
|
| Total control power (hold in) with max outputs |
External devices powered by control voltage: 518VA with HOA
|
| Input compatibility |
IEC 1133 Type 1+ per IEC
|
| Application in industrial area permitted (SCPD list) |
Size per NFPA 70 (NEC) or NFPA 79 for group motor applications
|
| Rated output operation voltage |
Sourced from control circuit: 30V DC
|
| Insulation voltage |
Power circuit: rated 600V
|
| Dielectric withstand |
Power circuit: 2500V AC per IEC
|
| Type of contacts |
Output rating- sourced from control circuit: normally open (NO)
|
| Current available |
50 mA maximum per input, 200 mA total
|
| Type of control circuit |
Output rating- sourced from control circuit: electromechanical relay
|
| Conventional thermal current (Ith) |
Output rating- sourced from control circuit: total of both outputs ≤2 A
|
| Circuit breaker operational current rating, max |
60A @ 480V (with gland type: CR or DR)
|
| RMS symmetrical amperes |
65 kA @ 480Y/277V (with gland type: RR)
|
| Rated operation voltage |
Power circuit: 200...575V
|
| 3-phase power/motor cable connection |
Conduit entrance with no motor cable
|
| Input filter - software selectable |
Settable from 0...64 ms in 1 ms increments (ON to OFF)
|
| Kind of current |
Output ratings (sourced from control circuit): AC/DC (not to be used as an AC/DC power supply)
|
| Fuse operational current rating, max |
Time delay: 20 A @ 480Y/277V (with gland type: RR)
|
| Total control power (pick up) |
Power requirements: 84VA with HOA
|
| Total control power (hold in) |
Power requirements: 9VA without HOA
|
| Trip class |
Class 10, 15, 20
|
| Operational power rating |
Full voltage starters - IP67/Type 4/12: 3Hp @ 575V AC, 60 Hz
|
| Number of digital inputs |
4
|
| Number of digital outputs |
2
|
| Supporting protocol for DeviceNet |
Yes
|
| Application in industrial area permitted |
Yes
|
| Mains frequency |
50/60 Hz
|
| Short circuit protection device performance (SCPD) type |
Type 1
|
| Short circuit rating |
30 kA
|
| Disconnect |
Motor disconnect
|
| Connection type |
Quick disconnects
|
| Utilization category |
Power circuit: AC-3 per IEC
|
| External devices powered by DeviceNet |
50 mA - total 200 mA
|
| Electrical life cycle |
Output ratings (sourced from control circuit): 100000 ops (1.8K ops/hr)
|
| Altitude |
2000 m
|
|---|---|
| Operating temperature |
-20 °C
|
| Storage and transportation temperature |
-25 °C
|
| Humidity |
5...95% (noncondensing)
|
| Protection against shock |
Power circuit: IP2X per IEC
|
| Surge transient |
1 kV L-L, 2 kV L-N (earth)
|
| Radiated emissions |
Class A, Group 1, equivalent to C2 emissions
|
| Conducted radio frequency emissions |
Class A
|
| Radio frequency electromagnetic field |
10 V/m
|
| Degree of protection (NEMA) |
4
|
| Pollution degree |
3
|
| Fast transient |
2 kV
|
| Electrostatic discharge |
4 kV contact and 8 kV air
|
| Height, approx |
287.5 mm
|
|---|---|
| Depth, approx |
Motor connection 243 mm (9.57 in) M35 cordset
|
| Wire size |
Power and ground terminals: #16... AWG per UL/NEMA (primary/sary terminal)
|
| Width, approx |
351 mm
|
| Number of poles |
3
|
| 基本信息 | 出版 |
|---|---|
| Product Cutsheet | -- |
| Specifications Sheet | -- |
| External Connections and OL Curves | -- |
| Dimension Sheet (PDF) | -- |
| Repair Parts List | -- |
| 用户手册 | 出版 |
|---|---|
| 280-um004_-en-p | 280-UM004 |
- UKCA DOC
截至 2025-09-10,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。
技术规格
| Communications |
DeviceNet
|
|---|---|
| Product Family |
ArmorStart
|
| Degree of protection (IP) |
IP67
|
|---|---|
| Shipping weight, approx |
10.4 kg
|
| Shock |
Opsal: 15 G
|
| Wire strip length |
Power and ground terminals: 0.35 in (9 mm)
|
| Vibration |
Opsal, 1 G, 0.15 mm (0.006 in) displacement
|
| Tightening torque |
Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal)
|
| Mechanical life operations |
Output ratings (sourced from control circuit): 50000000 ops (18K ops/hr)
|
| Disconnect lock out |
Recommend 8 mm (5/16 in) lock shackle or hasp. The hasp should not exceed 8 mm (5/16 in) when closed.
|
| Baud rates |
500 kbps
|
|---|---|
| Overload selection current range |
1.1 A
|
| Communication |
DeviceNet
|
| Short circuit protection |
10 A rated device
|
| DeviceNet input current surge |
15 A for 250 µs
|
| DeviceNet input current |
364mA @ 11V DC - 4.0 W
|
| Total with maximum sensor inputs (4) |
367mA @ 24V DC - 8.8 W
|
| Overvoltage category |
Control circuit: III per IEC
|
| Rated operational current |
Power circuit: 5.5 A maximum
|
| Product type |
Full voltage starter
|
| Rated impulse voltage |
Power circuit: 6 kV
|
| DeviceNet supply voltage rating |
24V DC nominal
|
| Control (pick up) |
Power requirements: 0.292 A without HOA
|
| Control (hold in) |
Power requirements: 0.038 A without HOA
|
| Input OFF-state current |
<1.5 mA
|
| Input OFF-state voltage |
0...5V DC
|
| Input ON-state voltage |
10...26V DC
|
| Distance, max |
500 m (1630 ft) @ 125 kbps
|
| Operating frequency |
Power circuit: 50/60 Hz
|
| Input ON-state current |
7.2mA @ 24V DC
|
| Option 1 |
Status only keypad
|
| Number of contacts |
Output rating- sourced from control circuit: 2
|
| Voltage status only |
11...25V DC from DeviceNet
|
| Outputs current (2) 1 A max. each |
External devices powered by control voltage: 2 A without HOA
|
| Trip rating |
120% of full load current (FLC) setting
|
| Total control power (pick up) with max outputs |
External devices powered by control voltage: 579VA with HOA
|
| Total control power (hold in) with max outputs |
External devices powered by control voltage: 518VA with HOA
|
| Input compatibility |
IEC 1133 Type 1+ per IEC
|
| Application in industrial area permitted (SCPD list) |
Size per NFPA 70 (NEC) or NFPA 79 for group motor applications
|
| Rated output operation voltage |
Sourced from control circuit: 30V DC
|
| Insulation voltage |
Power circuit: rated 600V
|
| Dielectric withstand |
Power circuit: 2500V AC per IEC
|
| Type of contacts |
Output rating- sourced from control circuit: normally open (NO)
|
| Current available |
50 mA maximum per input, 200 mA total
|
| Type of control circuit |
Output rating- sourced from control circuit: electromechanical relay
|
| Conventional thermal current (Ith) |
Output rating- sourced from control circuit: total of both outputs ≤2 A
|
| Circuit breaker operational current rating, max |
60A @ 480V (with gland type: CR or DR)
|
| RMS symmetrical amperes |
65 kA @ 480Y/277V (with gland type: RR)
|
| Rated operation voltage |
Power circuit: 200...575V
|
| 3-phase power/motor cable connection |
Conduit entrance with no motor cable
|
| Input filter - software selectable |
Settable from 0...64 ms in 1 ms increments (ON to OFF)
|
| Kind of current |
Output ratings (sourced from control circuit): AC/DC (not to be used as an AC/DC power supply)
|
| Fuse operational current rating, max |
Time delay: 20 A @ 480Y/277V (with gland type: RR)
|
| Total control power (pick up) |
Power requirements: 84VA with HOA
|
| Total control power (hold in) |
Power requirements: 9VA without HOA
|
| Trip class |
Class 10, 15, 20
|
| Operational power rating |
Full voltage starters - IP67/Type 4/12: 3Hp @ 575V AC, 60 Hz
|
| Number of digital inputs |
4
|
| Number of digital outputs |
2
|
| Supporting protocol for DeviceNet |
Yes
|
| Application in industrial area permitted |
Yes
|
| Mains frequency |
50/60 Hz
|
| Short circuit protection device performance (SCPD) type |
Type 1
|
| Short circuit rating |
30 kA
|
| Disconnect |
Motor disconnect
|
| Connection type |
Quick disconnects
|
| Utilization category |
Power circuit: AC-3 per IEC
|
| External devices powered by DeviceNet |
50 mA - total 200 mA
|
| Electrical life cycle |
Output ratings (sourced from control circuit): 100000 ops (1.8K ops/hr)
|
| Altitude |
2000 m
|
|---|---|
| Operating temperature |
-20 °C
|
| Storage and transportation temperature |
-25 °C
|
| Humidity |
5...95% (noncondensing)
|
| Protection against shock |
Power circuit: IP2X per IEC
|
| Surge transient |
1 kV L-L, 2 kV L-N (earth)
|
| Radiated emissions |
Class A, Group 1, equivalent to C2 emissions
|
| Conducted radio frequency emissions |
Class A
|
| Radio frequency electromagnetic field |
10 V/m
|
| Degree of protection (NEMA) |
4
|
| Pollution degree |
3
|
| Fast transient |
2 kV
|
| Electrostatic discharge |
4 kV contact and 8 kV air
|
| Height, approx |
287.5 mm
|
|---|---|
| Depth, approx |
Motor connection 243 mm (9.57 in) M35 cordset
|
| Wire size |
Power and ground terminals: #16... AWG per UL/NEMA (primary/sary terminal)
|
| Width, approx |
351 mm
|
| Number of poles |
3
|
文档
|
Product Cutsheet
基本信息
-- |
|
Specifications Sheet
基本信息
-- |
|
External Connections and OL Curves
基本信息
-- |
|
Dimension Sheet (PDF)
基本信息
-- |
|
Repair Parts List
基本信息
-- |
|
280-um004_-en-p
用户手册
280-UM004 |
| 基本信息 | 出版 |
|---|---|
| Product Cutsheet | -- |
| Specifications Sheet | -- |
| External Connections and OL Curves | -- |
| Dimension Sheet (PDF) | -- |
| Repair Parts List | -- |
| 用户手册 | 出版 |
| 280-um004_-en-p | 280-UM004 |
认证
- UKCA DOC
截至 2025-09-10,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。