技术规格
基本信息
Electrical
Mechanical
Environmental
Construction
图纸
文档
认证
配件
替代产品
技术说明
Control Voltage
100...240V AC
With display
No
Voltage type for actuating
AC
Rated operating voltage Ue
200 V
Rated control supply voltage at AC 50 Hz
100 V
Rated control supply voltage at AC 60 Hz
100 V
Controller rating
180 A
Continuous duty power structure heat dissipation
540 W
Overload current for line connected devices
60 A
Overload current for delta connected devices
104 A
Controller type
SMC-50
Trip classes
5...30
Trip current rating
118% of motor FLC
Base power draw from control module with heat sink fan
75 W @ 24V DC
DV/DT protection
RC snubber network
Repetitive peak inverse voltage rating
1400V per UL/CSA/NEMA for power circuit
Operating frequency
47...63 Hz or DC for control power
Rated impulse voltage
6000V per IEC for power circuit
Dielectric withstand
2500V per IEC for power circuit
Line connected motor current
Normal/standard duty: 60...180A @ 400/415/460V AC, 3-phase
Delta connected motor current
Normal/standard duty: 104...311A @ 400/415/460V AC, 3-phase
Transient protection
Metal oxide varistors: 220 J
Insulation voltage
Rated 500V per IEC for power circuit
Line connected motor power
Normal/standard duty: 50...150Hp @ 460V AC, 60 Hz, 3-phase
Delta connected motor power
Normal/standard duty: 63...160 kW @ 400/415V AC @ 50Hz, 3-phase
High capacity available fault current, max
65kA @ 600V, typical current 500 A time delay Class J or Class L fuse for inside delta connected motors
Utilization category
MG 1 per UL/CSA/NEMA for normal duty
Option power adder
5VA @ 100...240V AC, 150-SM6 (for each option installed, add to base power to obtain total power requirement)
Standard controller feature
Torque control
Standard available fault current, max
18kA @ 600V, typical current 800 A non-time delay fuse for inside delta connected motors
Optional controller feature
Param configuration/progming tools
Integrated motor overload protection
Yes
Short circuit protection device performance (SCPD) type
Type 1
Control power ride through
22 ms for control power
Control module battery type
CR 2032 for control power
Overload type
Electronic - using I2t algorithm
Output current, max
300mA @ 24V DC supply (terminals 8 and 12) for control power
Degree of protection (IP)
IP00
Shock
Opsal: 15 G
Width
Line/wye: 609.6 mm
Depth
Line/wye: 304.8 mm
Height
Line/wye: 762 mm
Power terminal lugs
One 10.5 mm (0.41 in) diam hole per power pole
Vibration
Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Function
Single direction
Power terminal markings
NEMA, CENELEC EN50 012
Control terminals
ClAing yoke connection, M3 screw clA
Storage and transportation temperature
-25 °C
Rated surrounding temperature range without derating
-20 °C
Humidity
5...95% (noncondensing)
Protection against electrical shock
IP2X (with optional terminal cover) per IEC
EMC emission levels
Radiated emissions: Class A (per EN 60947-4-2)
EMC immunity levels
Surge transient per EN 60947-4-2
Altitude
2000 m (6560 ft) without derating, for ops above 2000...7000 m (6560...22965 ft) maximum, refer to Thermal Wizard
Pollution degree
2
Mounting orientation
Vertical
Atmospheric protection
ANSI/ISA - 71.04-2013, class G3 environment
Operating ambient temperature
40 to 65 °C (104 to 149 °F) (refer to thermal wizard)
Number of poles
3
Horizontal clearance, min
0 cm
Vertical clearance, min
15 cm
Enclosure
Open type
Metal parts
Plated brass, copper or steel
Control modules
Thermoset and thermoplastic moldings
Power poles
Heatsink hockey puck thyristor modular design
图纸
3-Dimensional Drawing (STP) 下载 (ZIP)
Drawing File (PDF) 下载 (PDF)
2-Dimensional Drawings (DXF, DWG) 下载 (ZIP)
图纸
3-Dimensional Drawing (STP) 下载 (ZIP)
Drawing File (PDF) 下载 (PDF)
2-Dimensional Drawings (DXF, DWG) 下载 (ZIP)
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
基本信息 出版
Product Cutsheet --
Circuit Protection Devices And SCCR Tables --
Web Link to Technical Data (Includes Specifications and Modes of Operation) 150-TD009
用户手册 出版
150-um011_-en-p 150-UM011
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
访问技术文档中心 搜索文献资料库
China CCC Eurasion Economic Community Australian RCM
  • China CCC
  • Eurasion Economic Community
  • Australian RCM

截至 2026-01-31,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。

每页项目:
1-1 关于 1
每页项目:
1-1 关于 1
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
技术规格
Control Voltage
100...240V AC
With display
No
Voltage type for actuating
AC
Rated operating voltage Ue
200 V
Rated control supply voltage at AC 50 Hz
100 V
Rated control supply voltage at AC 60 Hz
100 V
Controller rating
180 A
Continuous duty power structure heat dissipation
540 W
Overload current for line connected devices
60 A
Overload current for delta connected devices
104 A
Controller type
SMC-50
Trip classes
5...30
Trip current rating
118% of motor FLC
Base power draw from control module with heat sink fan
75 W @ 24V DC
DV/DT protection
RC snubber network
Repetitive peak inverse voltage rating
1400V per UL/CSA/NEMA for power circuit
Operating frequency
47...63 Hz or DC for control power
Rated impulse voltage
6000V per IEC for power circuit
Dielectric withstand
2500V per IEC for power circuit
Line connected motor current
Normal/standard duty: 60...180A @ 400/415/460V AC, 3-phase
Delta connected motor current
Normal/standard duty: 104...311A @ 400/415/460V AC, 3-phase
Transient protection
Metal oxide varistors: 220 J
Insulation voltage
Rated 500V per IEC for power circuit
Line connected motor power
Normal/standard duty: 50...150Hp @ 460V AC, 60 Hz, 3-phase
Delta connected motor power
Normal/standard duty: 63...160 kW @ 400/415V AC @ 50Hz, 3-phase
High capacity available fault current, max
65kA @ 600V, typical current 500 A time delay Class J or Class L fuse for inside delta connected motors
Utilization category
MG 1 per UL/CSA/NEMA for normal duty
Option power adder
5VA @ 100...240V AC, 150-SM6 (for each option installed, add to base power to obtain total power requirement)
Standard controller feature
Torque control
Standard available fault current, max
18kA @ 600V, typical current 800 A non-time delay fuse for inside delta connected motors
Optional controller feature
Param configuration/progming tools
Integrated motor overload protection
Yes
Short circuit protection device performance (SCPD) type
Type 1
Control power ride through
22 ms for control power
Control module battery type
CR 2032 for control power
Overload type
Electronic - using I2t algorithm
Output current, max
300mA @ 24V DC supply (terminals 8 and 12) for control power
Degree of protection (IP)
IP00
Shock
Opsal: 15 G
Width
Line/wye: 609.6 mm
Depth
Line/wye: 304.8 mm
Height
Line/wye: 762 mm
Power terminal lugs
One 10.5 mm (0.41 in) diam hole per power pole
Vibration
Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Function
Single direction
Power terminal markings
NEMA, CENELEC EN50 012
Control terminals
ClAing yoke connection, M3 screw clA
Storage and transportation temperature
-25 °C
Rated surrounding temperature range without derating
-20 °C
Humidity
5...95% (noncondensing)
Protection against electrical shock
IP2X (with optional terminal cover) per IEC
EMC emission levels
Radiated emissions: Class A (per EN 60947-4-2)
EMC immunity levels
Surge transient per EN 60947-4-2
Altitude
2000 m (6560 ft) without derating, for ops above 2000...7000 m (6560...22965 ft) maximum, refer to Thermal Wizard
Pollution degree
2
Mounting orientation
Vertical
Atmospheric protection
ANSI/ISA - 71.04-2013, class G3 environment
Operating ambient temperature
40 to 65 °C (104 to 149 °F) (refer to thermal wizard)
Number of poles
3
Horizontal clearance, min
0 cm
Vertical clearance, min
15 cm
Enclosure
Open type
Metal parts
Plated brass, copper or steel
Control modules
Thermoset and thermoplastic moldings
Power poles
Heatsink hockey puck thyristor modular design
图纸
图纸
3-Dimensional Drawing (STP) 下载 (ZIP)
Drawing File (PDF) 下载 (PDF)
2-Dimensional Drawings (DXF, DWG) 下载 (ZIP)
图纸
3-Dimensional Drawing (STP) 下载 (ZIP)
Drawing File (PDF) 下载 (PDF)
2-Dimensional Drawings (DXF, DWG) 下载 (ZIP)
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
Product Cutsheet 基本信息
--
Circuit Protection Devices And SCCR Tables 基本信息
--
Web Link to Technical Data (Includes Specifications and Modes of Operation) 基本信息
150-TD009
150-um011_-en-p 用户手册
150-UM011
基本信息 出版
Product Cutsheet --
Circuit Protection Devices And SCCR Tables --
Web Link to Technical Data (Includes Specifications and Modes of Operation) 150-TD009
用户手册 出版
150-um011_-en-p 150-UM011
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
访问技术文档中心 搜索文献资料库
认证
China CCC Eurasion Economic Community Australian RCM
  • China CCC
  • Eurasion Economic Community
  • Australian RCM

截至 2026-01-31,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。

配件
每页项目:
1-1 关于 1
替代产品
每页项目:
1-1 关于 1
技术说明
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
寻找最近经销商
请联系您在{0}的经销商
更改位置
EmailEmail
PhonePhone
寻找合作伙伴
SMC-50 SOLID STATE MOTOR CONTROLLER 180A
CloseClose
150-SB4NBD
关闭
打印
Allen-Bradley 150-SB4NBD product image
电话:
呼叫
Rockwell Automation Home
Copyright ©2026 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页
  2. Chevron LeftChevron Left 产品
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose