| Continuous VA (XFrmr Rating) |
63 VA
|
|---|---|
| PrimaryCode |
240/480V(60Hz), 220/440V(50Hz)
|
| SecondaryCode |
110V (50Hz) / 120V (60Hz)
|
| Rated apparent power |
63 VA
|
|---|---|
| Secondary voltage |
110V-50 Hz/120V-60 Hz
|
| Fuse block option |
0 primary-0 sary
|
| Secondary fuse size |
4A @ 24V (per NEC)
|
| Primary voltage |
240/480V-60 Hz/220/440V-50 Hz
|
| Factory installed options |
No cover/no sary fuse
|
| Inrush VA |
347VA @ 85% of rated sary voltage, 40% power factor
|
| Primary fuse size |
0.75A @ 240V (when only primary protection is used per NEC)
|
| Short-circuit-proof |
No
|
| Bulk package |
Single pack
|
|---|---|
| Depth |
Without fusing: 3-7/8 in (98.00 mm)
|
| Width |
Without fusing: 3.5 in (88.90 mm)
|
| Height |
Without fusing: 2-3/8 in (73.91 mm)
|
| Shipping weight, approx |
Without top mounted fuse block: 4.5 lb (2.04 Kg)
|
| Modular version |
No
|
| Ring core |
No
|
| Built as energy saving transformer |
No
|
| Built as safety transformer |
No
|
| Built as isolating transformer |
No
|
| Conductor material |
Copper
|
| Type of insulation material according to IEC 85 |
B
|
|---|
| Suitable for mounting on PCB |
No
|
|---|
| 类型 | 资源 | 出版 |
|---|---|---|
| Technical Data | 1497-td001_-en-p | 1497-TD001 |
| 常规 | Product Cutsheet | -- |
技术规格
| Continuous VA (XFrmr Rating) |
63 VA
|
|---|---|
| PrimaryCode |
240/480V(60Hz), 220/440V(50Hz)
|
| SecondaryCode |
110V (50Hz) / 120V (60Hz)
|
| Rated apparent power |
63 VA
|
|---|---|
| Secondary voltage |
110V-50 Hz/120V-60 Hz
|
| Fuse block option |
0 primary-0 sary
|
| Secondary fuse size |
4A @ 24V (per NEC)
|
| Primary voltage |
240/480V-60 Hz/220/440V-50 Hz
|
| Factory installed options |
No cover/no sary fuse
|
| Inrush VA |
347VA @ 85% of rated sary voltage, 40% power factor
|
| Primary fuse size |
0.75A @ 240V (when only primary protection is used per NEC)
|
| Short-circuit-proof |
No
|
| Bulk package |
Single pack
|
|---|---|
| Depth |
Without fusing: 3-7/8 in (98.00 mm)
|
| Width |
Without fusing: 3.5 in (88.90 mm)
|
| Height |
Without fusing: 2-3/8 in (73.91 mm)
|
| Shipping weight, approx |
Without top mounted fuse block: 4.5 lb (2.04 Kg)
|
| Modular version |
No
|
| Ring core |
No
|
| Built as energy saving transformer |
No
|
| Built as safety transformer |
No
|
| Built as isolating transformer |
No
|
| Conductor material |
Copper
|
| Type of insulation material according to IEC 85 |
B
|
|---|
| Suitable for mounting on PCB |
No
|
|---|
文档
|
1497-td001_-en-p
Technical Data
1497-TD001 |
|
Product Cutsheet
常规
-- |
| 类型 | 资源 | 出版 |
|---|---|---|
| Technical Data | 1497-td001_-en-p | 1497-TD001 |
| 常规 | Product Cutsheet | -- |
配件
替代产品
技术说明
Loading
Copyright ©2025 Rockwell Automation, Inc.