Product at a glance
Replacement Available
生命周期状态: 停止
ErrorsErrors
Rockwell Automation announces that as of February 25, 2022, the Motor Protection Circuit-Breaker will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期: February 25, 2022 替代类别: Engineering Replacement 替代产品: 140MT-D9E-B63 [https://www.rockwellautomation.com.cn/products/details.140MT-D9E-B63.html]
Product at a glance
Replacement Available
添加到BoM
  • 寻找支持
Technical Specifications
Drawings
Documents
Certifications
Technotes
With integrated auxiliary switch False
With integrated under voltage release False
Rated short-circuit breaking capacity lcu at 400 V, AC 100 kA
Rated operation power at AC-3, 400 V 2.2 kw
Rated permanent current Iu 6.3 A
Rated operation power at AC-3, 230 V 1.5 kw
Rated operating voltage 230 A
Type of control element Turn button
Overload release current setting 4 A
Type of electrical connection of main circuit Screw connection
Rated frequency 60 Hz
Magnetic release current per IEC 82 A
Rated operational current (Ie) per IEC 6.3 A
Magnetic trip current 82 A
Rated supply current (Ie) 1.6 A
Total power loss (Pv) for circuit breaker at rated load operating temperature 6 W
Current range 4 to 6.3 A
Ultimate short circuit breaking capacity (Icu) per IEC 6kA @ 690V
Rated service short circuit breaking capacity (Ics) per IEC 6kA @ 690V
Hp rating, max 5Hp @ 575V, 3-phase
Rated insulation voltage (Ui) 690V per IEC, SEV, VDE0660
Electrical life cycle 100000 ops (Ie maximum)
Switching of standard motors per IEC 4.0 kW @ 690V (AC-3), 3-phase
KW rating, max 4 kW @ 690V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC No back-up fuse required @ 500V
Short circuit current (Type 2 coordination), max 65kA @ 480V
Short circuit current for group motor installation with 100-C contactor, max 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect with 100-C contactor, max 65kA @ 480V, UL 508-manual motor controller
Short circuit current for group motor installation with 100-K contactor, max 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect with 100-K contactor, max 65kA @ 480V, UL 508-manual motor controller
Rated thermal current (Ith) 1.6...32 A @ up to 60 °C ambient temperature
Short circuit current for combination motor controller with 100-C contactor, max 65 kA @ 480Y/277V per UL 508-self-protected (Type E)
Short circuit current for tap conductor protection, max 65 kA @ 480Y/277V per UL 508-manual motor controller
Short circuit current for combination motor controller, max 65 kA @ 480Y/277V, UL 508-Type F
Fuse or circuit breaker per NEC, max 450 A, UL 508-manual motor controller with 100-C contactor
Rated impulse withstand voltage (Uimp) Main circuits/overvoltage category: 6 kV/III
Short circuit current for group motor installation, max 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect, max 65kA @ 480V, UL 508-manual motor controller
Number of poles 3
With thermal protection True
Phase failure sensitive True
Switch off technique Thermomagnetic
Switching frequency, max 25 ops/h
Overload trip class 10
Phase loss protection Differential release
Fuse or circuit breaker rating with 100-K contactor per NEC, max 450 A, UL 508-manual motor controller
Degree of protection (IP) IP2X
Weight 373 lb
Mechanical life operations 100000 /h
Breaking capacity High breaking capacity
Protection type Adjustable thermal/fixed magnetic (13 x In)
Factory option No circuit-breaker auxiliary or trip contacts
Vibration resistance Ops (60068-2-6): 5 G
Shock resistance Transport (60068-2-27): 30 g, 11 ms, all axes
Ambient storage temperature -40 °C
Ambient operating temperature -25 °C
Ambient temperature compensation -20 °C
Site altitude 2000 m (NN)
Dependence on temperature No current reduction
Magnetic release current (±20 %) Fixed setting 13...14 x Ie max. Ie max. = maximum values of setting ranges
Pollution degree 3
Moisture heat (60068-2-3) 40 °C, relative humidity 93 %, 56 d
Dry heat (60086-2-2) 100 °C, relative humidity < 50 %, 7 d
Moisture change climate (600068-2-30) 23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles
Frame size Frame size D, 32 A
Contactor size for combination motor controller, min 100-K05, UL-508-Type F
Contactor size, min 100-K05, UL 508-manual motor controller
Device construction Built-in device fixed built-in technique
Utilization category Motor starter: AC-3 (IEC60947-4-1)
Overload protection characteristics IEC 60947-4-1 motor protection
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
类型 资源 出版
Technical Data 140m-td002_-en-p 140M-TD002
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库 Chevron RightChevron Right
China CCC
  • China CCC

This product was certified with the above certifications as of 2025-08-26. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库 Chevron RightChevron Right
技术规格
With integrated auxiliary switch False
With integrated under voltage release False
Rated short-circuit breaking capacity lcu at 400 V, AC 100 kA
Rated operation power at AC-3, 400 V 2.2 kw
Rated permanent current Iu 6.3 A
Rated operation power at AC-3, 230 V 1.5 kw
Rated operating voltage 230 A
Type of control element Turn button
Overload release current setting 4 A
Type of electrical connection of main circuit Screw connection
Rated frequency 60 Hz
Magnetic release current per IEC 82 A
Rated operational current (Ie) per IEC 6.3 A
Magnetic trip current 82 A
Rated supply current (Ie) 1.6 A
Total power loss (Pv) for circuit breaker at rated load operating temperature 6 W
Current range 4 to 6.3 A
Ultimate short circuit breaking capacity (Icu) per IEC 6kA @ 690V
Rated service short circuit breaking capacity (Ics) per IEC 6kA @ 690V
Hp rating, max 5Hp @ 575V, 3-phase
Rated insulation voltage (Ui) 690V per IEC, SEV, VDE0660
Electrical life cycle 100000 ops (Ie maximum)
Switching of standard motors per IEC 4.0 kW @ 690V (AC-3), 3-phase
KW rating, max 4 kW @ 690V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC No back-up fuse required @ 500V
Short circuit current (Type 2 coordination), max 65kA @ 480V
Short circuit current for group motor installation with 100-C contactor, max 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect with 100-C contactor, max 65kA @ 480V, UL 508-manual motor controller
Short circuit current for group motor installation with 100-K contactor, max 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect with 100-K contactor, max 65kA @ 480V, UL 508-manual motor controller
Rated thermal current (Ith) 1.6...32 A @ up to 60 °C ambient temperature
Short circuit current for combination motor controller with 100-C contactor, max 65 kA @ 480Y/277V per UL 508-self-protected (Type E)
Short circuit current for tap conductor protection, max 65 kA @ 480Y/277V per UL 508-manual motor controller
Short circuit current for combination motor controller, max 65 kA @ 480Y/277V, UL 508-Type F
Fuse or circuit breaker per NEC, max 450 A, UL 508-manual motor controller with 100-C contactor
Rated impulse withstand voltage (Uimp) Main circuits/overvoltage category: 6 kV/III
Short circuit current for group motor installation, max 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect, max 65kA @ 480V, UL 508-manual motor controller
Number of poles 3
With thermal protection True
Phase failure sensitive True
Switch off technique Thermomagnetic
Switching frequency, max 25 ops/h
Overload trip class 10
Phase loss protection Differential release
Fuse or circuit breaker rating with 100-K contactor per NEC, max 450 A, UL 508-manual motor controller
Degree of protection (IP) IP2X
Weight 373 lb
Mechanical life operations 100000 /h
Breaking capacity High breaking capacity
Protection type Adjustable thermal/fixed magnetic (13 x In)
Factory option No circuit-breaker auxiliary or trip contacts
Vibration resistance Ops (60068-2-6): 5 G
Shock resistance Transport (60068-2-27): 30 g, 11 ms, all axes
Ambient storage temperature -40 °C
Ambient operating temperature -25 °C
Ambient temperature compensation -20 °C
Site altitude 2000 m (NN)
Dependence on temperature No current reduction
Magnetic release current (±20 %) Fixed setting 13...14 x Ie max. Ie max. = maximum values of setting ranges
Pollution degree 3
Moisture heat (60068-2-3) 40 °C, relative humidity 93 %, 56 d
Dry heat (60086-2-2) 100 °C, relative humidity < 50 %, 7 d
Moisture change climate (600068-2-30) 23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles
Frame size Frame size D, 32 A
Contactor size for combination motor controller, min 100-K05, UL-508-Type F
Contactor size, min 100-K05, UL 508-manual motor controller
Device construction Built-in device fixed built-in technique
Utilization category Motor starter: AC-3 (IEC60947-4-1)
Overload protection characteristics IEC 60947-4-1 motor protection
图纸
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
140m-td002_-en-p Technical Data
140M-TD002
类型 资源 出版
Technical Data 140m-td002_-en-p 140M-TD002
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库 Chevron RightChevron Right
认证
China CCC
  • China CCC

This product was certified with the above certifications as of 2025-08-26. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库 Chevron RightChevron Right
Loading
寻找最近经销商
更改位置
EmailEmail
PhonePhone
寻找合作伙伴 Chevron RightChevron Right
Motor Protection Circuit-Breaker
CloseClose
140M-D8E-B63
关闭
打印
Allen-Bradley 140M-D8E-B63 product image
电话:
呼叫
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页 Chevron RightChevron Right
  2. Chevron LeftChevron Left 产品 Chevron RightChevron Right
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose