140M-C2E-C10
Motor Protection Circuit-Breaker
Rockwell Automation announces that as of February 04, 2022, the Motor Protection Circuit-Breaker will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
February 04, 2022
替代类别:
Engineering Replacement
替代产品:
140MT-C3E-C10
[https://www.rockwellautomation.com.cn/products/details.140MT-C3E-C10.html]
Product at a glance
Rockwell Automation announces that as of February 04, 2022, the Motor Protection Circuit-Breaker will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
February 04, 2022
替代类别:
Engineering Replacement
替代产品:
140MT-C3E-C10
[https://www.rockwellautomation.com.cn/products/details.140MT-C3E-C10.html]
Product at a glance
| Adj. Thermal Current Range (A) | 6.3 - 10A,MxRtg MCPs(no OvPrt)is 1200.0A |
|---|---|
| Circuit Breaker Type | Mtr Prt Circuit Breaker |
| With integrated auxiliary switch | False |
|---|---|
| With integrated under voltage release | False |
| Rated short-circuit breaking capacity lcu at 400 V, AC | 100 kA |
| Rated operation power at AC-3, 400 V | 4 kw |
| Rated operation power at AC-3, 230 V | 2.2 kw |
| Rated operating voltage | 230 A |
| Type of control element | Turn button |
| Overload release current setting | 6.3 A |
| Type of electrical connection of main circuit | Screw connection |
| Magnetic release current per IEC | 130 A |
| Rated operational current (Ie) per IEC | 10 A |
| Magnetic trip current | 130 A |
| Short circuit current (Type 2 coordination), max-inv | 50kA @ 480V |
| Current range | 6.3...10 A |
| Ultimate short circuit breaking capacity (Icu) per IEC | 50kA @ 500V |
| Rated service short circuit breaking capacity (Ics) per IEC | 50kA @ 500V |
| Hp rating, max | 7.5Hp @ 460V, 3-phase |
| Rated operating voltage, max | 690V per IEC, SEV, VDE0660 |
| Electrical life cycle | (Ie max.) 100000 ops |
| Short circuit current for combination motor controller with 100-K contactor, max-inv | 65 kA @ 480Y/277V, UL 508-Type F |
| Short circuit current for combination motor controller with 100-C contactor, max-inv | 65 kA @ 480Y/277V, UL 508-Type F |
| Short circuit current for self-protected combination motor controller with 100-C contactor, max-inv | 65 kA @ 480Y/277V, UL 508-Type E |
| Switching of standard motors per IEC | 7.5 kW @ 690V, 3-phase |
| KW rating, max | 7.5 kW @ 690V (AC-3), 3-phase |
| Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC | No back-up fuse required @ 400/415V |
| Short circuit current for group motor installation with 100-K contactor, max-inv | 65kA @ 480V, UL 508-manual motor controller |
| Short circuit current for motor disconnect with 100-K contactor, max-inv | 65kA @ 480V, UL 508-manual motor controller |
| Short circuit current for group motor installation with 100-C contactor, max-inv | 65kA @ 480V, UL 508-manual motor controller |
| Short circuit current for motor disconnect with 100-C contactor, max-inv | 65kA @ 480V, UL 508-manual motor controller |
| Rated thermal current | 0.1...32A @ 60°C ambient temperature (Ith)-inv |
| Short circuit current for tap conductor protection, max | 65 kA @ 480Y/277V per UL 508-manual motor controller |
| Short circuit current for combination motor controller, max | 65kA @ 480V/277V per UL 508-self-protected (Type E) |
| Fuse or circuit breaker per NEC, max | 450 A, UL 508-manual motor controller |
| Fuse or circuit breaker rating per NEC, max | 450 A, UL 508-manual motor controller with 100-C contactor |
| Short circuit current for group motor installation, max | 65kA @ 480V, UL 508-manual motor controller |
| Short circuit current for motor disconnect, max | 65kA @ 480V, UL 508-manual motor controller |
| Magnetic release current | Fixed setting 13...14 x Ie max. Ie max. = maximum values of setting ranges, (±20 %) |
| Number of poles | 3 |
| With thermal protection | True |
| Phase failure sensitive | True |
| Switch off technique | Thermomagnetic |
| Switching frequency, max | 25 ops/h |
| Trip class | 10 |
| Rated frequency | 50/60 Hz |
| Rated supply current | 0.1 A |
| Total power loss (Pv) for circuit breaker at rated load operating temperature-inv | 6 W |
| Phase loss protection | Differential release |
| Fuse or circuit breaker rating with 100-K contactor per NEC, max | 450 A, UL 508-manual motor controller |
| Main circuits/overvoltage category | 6kV/III @ rated impulse withstand voltage (Uimp) |
| Auxiliary circuits/overvoltage category-inv | 6kV/III @ rated impulse withstand voltage (Uimp) |
| Width | 45 mm |
|---|---|
| Depth | 74.5 mm |
| Height | 90 mm |
| Contactor size (Type 2 coordination), min-inv | 100-C30 @ 600V |
| Frame size | Frame size C, 32 A |
| Contactor size, min-inv | 100-K09: UL-508-Type F combination motor controller |
| Device construction | Built-in device fixed built-in technique |
| Degree of protection (IP) | IP2X |
|---|---|
| Weight | 317 lb |
| Mechanical life operations | 100000 /h |
| Breaking capacity | Standard breaking capacity |
| Protection type | Adjustable thermal/fixed magnetic (13 x In) |
| Factory option | No circuit-breaker auxiliary or trip contacts |
| Terminal type | Screw connection |
| Vibration resistance | Ops (60068-2-6): 5 G |
| Shock resistance | Transport (60068-2-27): 30 G, 11 ms, all axes |
| Ambient storage temperature | -40 °C |
|---|---|
| Ambient operating temperature | -25 °C |
| Ambient temperature compensation | -20 °C |
| Site altitude | To 2000 N.N.(m) |
| Moisture heat | 40 °C, relative humidity 93 %, 56 d (60068-2-3)-inv |
| Dry heat | 100 °C, relative humidity < 50 %, 7 d (60086-2-2)-inv |
| Dependence on temperature | No current reduction @ 60 °C-inv |
| Moisture change climate | 23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles (600068-2-30)-inv |
| Pollution degree | 3 |
| Utilization category | Motor starter: AC-3 (IEC60947-4-1) |
|---|---|
| Overload protection characteristics | IEC 60947-4-1 motor protection |
| 类型 | 资源 | 出版 |
|---|---|---|
| Technical Data | 140m-td002_-en-p | 140M-TD002 |
技术规格
| Adj. Thermal Current Range (A) | 6.3 - 10A,MxRtg MCPs(no OvPrt)is 1200.0A |
|---|---|
| Circuit Breaker Type | Mtr Prt Circuit Breaker |
| With integrated auxiliary switch | False |
|---|---|
| With integrated under voltage release | False |
| Rated short-circuit breaking capacity lcu at 400 V, AC | 100 kA |
| Rated operation power at AC-3, 400 V | 4 kw |
| Rated operation power at AC-3, 230 V | 2.2 kw |
| Rated operating voltage | 230 A |
| Type of control element | Turn button |
| Overload release current setting | 6.3 A |
| Type of electrical connection of main circuit | Screw connection |
| Magnetic release current per IEC | 130 A |
| Rated operational current (Ie) per IEC | 10 A |
| Magnetic trip current | 130 A |
| Short circuit current (Type 2 coordination), max-inv | 50kA @ 480V |
| Current range | 6.3...10 A |
| Ultimate short circuit breaking capacity (Icu) per IEC | 50kA @ 500V |
| Rated service short circuit breaking capacity (Ics) per IEC | 50kA @ 500V |
| Hp rating, max | 7.5Hp @ 460V, 3-phase |
| Rated operating voltage, max | 690V per IEC, SEV, VDE0660 |
| Electrical life cycle | (Ie max.) 100000 ops |
| Short circuit current for combination motor controller with 100-K contactor, max-inv | 65 kA @ 480Y/277V, UL 508-Type F |
| Short circuit current for combination motor controller with 100-C contactor, max-inv | 65 kA @ 480Y/277V, UL 508-Type F |
| Short circuit current for self-protected combination motor controller with 100-C contactor, max-inv | 65 kA @ 480Y/277V, UL 508-Type E |
| Switching of standard motors per IEC | 7.5 kW @ 690V, 3-phase |
| KW rating, max | 7.5 kW @ 690V (AC-3), 3-phase |
| Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC | No back-up fuse required @ 400/415V |
| Short circuit current for group motor installation with 100-K contactor, max-inv | 65kA @ 480V, UL 508-manual motor controller |
| Short circuit current for motor disconnect with 100-K contactor, max-inv | 65kA @ 480V, UL 508-manual motor controller |
| Short circuit current for group motor installation with 100-C contactor, max-inv | 65kA @ 480V, UL 508-manual motor controller |
| Short circuit current for motor disconnect with 100-C contactor, max-inv | 65kA @ 480V, UL 508-manual motor controller |
| Rated thermal current | 0.1...32A @ 60°C ambient temperature (Ith)-inv |
| Short circuit current for tap conductor protection, max | 65 kA @ 480Y/277V per UL 508-manual motor controller |
| Short circuit current for combination motor controller, max | 65kA @ 480V/277V per UL 508-self-protected (Type E) |
| Fuse or circuit breaker per NEC, max | 450 A, UL 508-manual motor controller |
| Fuse or circuit breaker rating per NEC, max | 450 A, UL 508-manual motor controller with 100-C contactor |
| Short circuit current for group motor installation, max | 65kA @ 480V, UL 508-manual motor controller |
| Short circuit current for motor disconnect, max | 65kA @ 480V, UL 508-manual motor controller |
| Magnetic release current | Fixed setting 13...14 x Ie max. Ie max. = maximum values of setting ranges, (±20 %) |
| Number of poles | 3 |
| With thermal protection | True |
| Phase failure sensitive | True |
| Switch off technique | Thermomagnetic |
| Switching frequency, max | 25 ops/h |
| Trip class | 10 |
| Rated frequency | 50/60 Hz |
| Rated supply current | 0.1 A |
| Total power loss (Pv) for circuit breaker at rated load operating temperature-inv | 6 W |
| Phase loss protection | Differential release |
| Fuse or circuit breaker rating with 100-K contactor per NEC, max | 450 A, UL 508-manual motor controller |
| Main circuits/overvoltage category | 6kV/III @ rated impulse withstand voltage (Uimp) |
| Auxiliary circuits/overvoltage category-inv | 6kV/III @ rated impulse withstand voltage (Uimp) |
| Width | 45 mm |
|---|---|
| Depth | 74.5 mm |
| Height | 90 mm |
| Contactor size (Type 2 coordination), min-inv | 100-C30 @ 600V |
| Frame size | Frame size C, 32 A |
| Contactor size, min-inv | 100-K09: UL-508-Type F combination motor controller |
| Device construction | Built-in device fixed built-in technique |
| Degree of protection (IP) | IP2X |
|---|---|
| Weight | 317 lb |
| Mechanical life operations | 100000 /h |
| Breaking capacity | Standard breaking capacity |
| Protection type | Adjustable thermal/fixed magnetic (13 x In) |
| Factory option | No circuit-breaker auxiliary or trip contacts |
| Terminal type | Screw connection |
| Vibration resistance | Ops (60068-2-6): 5 G |
| Shock resistance | Transport (60068-2-27): 30 G, 11 ms, all axes |
| Ambient storage temperature | -40 °C |
|---|---|
| Ambient operating temperature | -25 °C |
| Ambient temperature compensation | -20 °C |
| Site altitude | To 2000 N.N.(m) |
| Moisture heat | 40 °C, relative humidity 93 %, 56 d (60068-2-3)-inv |
| Dry heat | 100 °C, relative humidity < 50 %, 7 d (60086-2-2)-inv |
| Dependence on temperature | No current reduction @ 60 °C-inv |
| Moisture change climate | 23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles (600068-2-30)-inv |
| Pollution degree | 3 |
| Utilization category | Motor starter: AC-3 (IEC60947-4-1) |
|---|---|
| Overload protection characteristics | IEC 60947-4-1 motor protection |
文档
|
140m-td002_-en-p
Technical Data
140M-TD002 |
| 类型 | 资源 | 出版 |
|---|---|---|
| Technical Data | 140m-td002_-en-p | 140M-TD002 |
技术说明
Loading
Copyright ©2025 Rockwell Automation, Inc.