Loading
Allen-Bradley 140M-C2E-A40 product image
Allen Bradley
140M-C2E-A40

Motor Protection Circuit-Breaker

PrintPrint
打印
EmailEmail
共享
Product RegistrationProduct Registration
QR code
Allen-Bradley 140M-C2E-A40 product image
Allen Bradley
生命周期状态: 停止
ErrorsErrors
Rockwell Automation announces that as of February 18, 2022, the Motor Protection Circuit-Breaker will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期: February 18, 2022 替代类别: Engineering Replacement 替代产品: 140MT-C3E-A40 [https://www.rockwellautomation.com.cn/products/details.140MT-C3E-A40.html]
Product at a glance
Replacement Available
生命周期状态: 停止
ErrorsErrors
Rockwell Automation announces that as of February 18, 2022, the Motor Protection Circuit-Breaker will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期: February 18, 2022 替代类别: Engineering Replacement 替代产品: 140MT-C3E-A40 [https://www.rockwellautomation.com.cn/products/details.140MT-C3E-A40.html]
Product at a glance
Replacement Available
添加到BoM
  • 寻找支持
Technical Specifications
Drawings
Documents
Technotes
Adj. Thermal Current Range (A) 0.25 - 0.4A,MxRtg MCPs(no OvPrt)is 1200.0A
With integrated auxiliary switch False
With integrated under voltage release False
Rated short-circuit breaking capacity lcu at 400 V, AC 100 kA
Rated operation power at AC-3, 230 V 0.06 kw
Rated operating voltage 230 A
Type of control element Turn button
Overload release current setting 0.25 A
Type of electrical connection of main circuit Screw connection
Magnetic release current per IEC 5.2 A
Rated operational current (Ie) per IEC 0.4 A
Magnetic trip current 5.2 A
Short circuit current (Type 2 coordination), max-inv 65kA @ 480V
Current range 0.25...0.40 A
Ultimate short circuit breaking capacity (Icu) per IEC 100kA @ 690V
Rated service short circuit breaking capacity (Ics) per IEC 100kA @ 690V
Hp rating, max 0.25Hp @ 575V, 3-phase
Rated operating voltage, max 690V per IEC, SEV, VDE0660
Electrical life cycle (Ie max.) 100000 ops
Short circuit current for combination motor controller with 100-K contactor, max-inv 65 kA @ 480Y/277V, UL 508-Type F
Short circuit current for combination motor controller with 100-C contactor, max-inv 65 kA @ 480Y/277V, UL 508-Type F
Short circuit current for self-protected combination motor controller with 100-C contactor, max-inv 65 kA @ 480Y/277V, UL 508-Type E
Switching of standard motors per IEC 0.18 kW @ 690V, 3-phase
KW rating, max 0.18 kW @ 690V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC No back-up fuse required @ 690V
Short circuit current for group motor installation with 100-K contactor, max-inv 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect with 100-K contactor, max-inv 65kA @ 480V, UL 508-manual motor controller
Short circuit current for group motor installation with 100-C contactor, max-inv 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect with 100-C contactor, max-inv 65kA @ 480V, UL 508-manual motor controller
Rated thermal current 0.1...32A @ 60°C ambient temperature (Ith)-inv
Short circuit current for tap conductor protection, max 65 kA @ 480Y/277V per UL 508-manual motor controller
Short circuit current for combination motor controller, max 65kA @ 480V/277V per UL 508-self-protected (Type E)
Fuse or circuit breaker per NEC, max 450 A, UL 508-manual motor controller
Fuse or circuit breaker rating per NEC, max 450 A, UL 508-manual motor controller with 100-C contactor
Short circuit current for group motor installation, max 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect, max 65kA @ 480V, UL 508-manual motor controller
Magnetic release current Fixed setting 13...14 x Ie max. Ie max. = maximum values of setting ranges, (±20 %)
Number of poles 3
With thermal protection True
Phase failure sensitive True
Switch off technique Thermomagnetic
Switching frequency, max 25 ops/h
Trip class 10
Rated frequency 50/60 Hz
Rated supply current 0.1 A
Total power loss (Pv) for circuit breaker at rated load operating temperature-inv 6 W
Phase loss protection Differential release
Fuse or circuit breaker rating with 100-K contactor per NEC, max 450 A, UL 508-manual motor controller
Main circuits/overvoltage category 6kV/III @ rated impulse withstand voltage (Uimp)
Auxiliary circuits/overvoltage category-inv 6kV/III @ rated impulse withstand voltage (Uimp)
Width 45 mm
Depth 74.5 mm
Height 90 mm
Contactor size (Type 2 coordination), min-inv 100-C09 @ 600V
Frame size Frame size C, 32 A
Contactor size, min-inv 100-K05: UL-508-Type F combination motor controller
Device construction Built-in device fixed built-in technique
Degree of protection (IP) IP2X
Weight 317 lb
Mechanical life operations 100000 /h
Breaking capacity Standard breaking capacity
Protection type Adjustable thermal/fixed magnetic (13 x In)
Factory option No circuit-breaker auxiliary or trip contacts
Terminal type Screw connection
Vibration resistance Ops (60068-2-6): 5 G
Shock resistance Transport (60068-2-27): 30 G, 11 ms, all axes
Ambient storage temperature -40 °C
Ambient operating temperature -25 °C
Ambient temperature compensation -20 °C
Site altitude To 2000 N.N.(m)
Moisture heat 40 °C, relative humidity 93 %, 56 d (60068-2-3)-inv
Dry heat 100 °C, relative humidity < 50 %, 7 d (60086-2-2)-inv
Dependence on temperature No current reduction @ 60 °C-inv
Moisture change climate 23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles (600068-2-30)-inv
Pollution degree 3
Utilization category Motor starter: AC-3 (IEC60947-4-1)
Overload protection characteristics IEC 60947-4-1 motor protection
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
类型 资源 出版
Technical Data 140m-td002_-en-p 140M-TD002
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库 Chevron RightChevron Right
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库 Chevron RightChevron Right
技术规格
Adj. Thermal Current Range (A) 0.25 - 0.4A,MxRtg MCPs(no OvPrt)is 1200.0A
With integrated auxiliary switch False
With integrated under voltage release False
Rated short-circuit breaking capacity lcu at 400 V, AC 100 kA
Rated operation power at AC-3, 230 V 0.06 kw
Rated operating voltage 230 A
Type of control element Turn button
Overload release current setting 0.25 A
Type of electrical connection of main circuit Screw connection
Magnetic release current per IEC 5.2 A
Rated operational current (Ie) per IEC 0.4 A
Magnetic trip current 5.2 A
Short circuit current (Type 2 coordination), max-inv 65kA @ 480V
Current range 0.25...0.40 A
Ultimate short circuit breaking capacity (Icu) per IEC 100kA @ 690V
Rated service short circuit breaking capacity (Ics) per IEC 100kA @ 690V
Hp rating, max 0.25Hp @ 575V, 3-phase
Rated operating voltage, max 690V per IEC, SEV, VDE0660
Electrical life cycle (Ie max.) 100000 ops
Short circuit current for combination motor controller with 100-K contactor, max-inv 65 kA @ 480Y/277V, UL 508-Type F
Short circuit current for combination motor controller with 100-C contactor, max-inv 65 kA @ 480Y/277V, UL 508-Type F
Short circuit current for self-protected combination motor controller with 100-C contactor, max-inv 65 kA @ 480Y/277V, UL 508-Type E
Switching of standard motors per IEC 0.18 kW @ 690V, 3-phase
KW rating, max 0.18 kW @ 690V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC No back-up fuse required @ 690V
Short circuit current for group motor installation with 100-K contactor, max-inv 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect with 100-K contactor, max-inv 65kA @ 480V, UL 508-manual motor controller
Short circuit current for group motor installation with 100-C contactor, max-inv 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect with 100-C contactor, max-inv 65kA @ 480V, UL 508-manual motor controller
Rated thermal current 0.1...32A @ 60°C ambient temperature (Ith)-inv
Short circuit current for tap conductor protection, max 65 kA @ 480Y/277V per UL 508-manual motor controller
Short circuit current for combination motor controller, max 65kA @ 480V/277V per UL 508-self-protected (Type E)
Fuse or circuit breaker per NEC, max 450 A, UL 508-manual motor controller
Fuse or circuit breaker rating per NEC, max 450 A, UL 508-manual motor controller with 100-C contactor
Short circuit current for group motor installation, max 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect, max 65kA @ 480V, UL 508-manual motor controller
Magnetic release current Fixed setting 13...14 x Ie max. Ie max. = maximum values of setting ranges, (±20 %)
Number of poles 3
With thermal protection True
Phase failure sensitive True
Switch off technique Thermomagnetic
Switching frequency, max 25 ops/h
Trip class 10
Rated frequency 50/60 Hz
Rated supply current 0.1 A
Total power loss (Pv) for circuit breaker at rated load operating temperature-inv 6 W
Phase loss protection Differential release
Fuse or circuit breaker rating with 100-K contactor per NEC, max 450 A, UL 508-manual motor controller
Main circuits/overvoltage category 6kV/III @ rated impulse withstand voltage (Uimp)
Auxiliary circuits/overvoltage category-inv 6kV/III @ rated impulse withstand voltage (Uimp)
Width 45 mm
Depth 74.5 mm
Height 90 mm
Contactor size (Type 2 coordination), min-inv 100-C09 @ 600V
Frame size Frame size C, 32 A
Contactor size, min-inv 100-K05: UL-508-Type F combination motor controller
Device construction Built-in device fixed built-in technique
Degree of protection (IP) IP2X
Weight 317 lb
Mechanical life operations 100000 /h
Breaking capacity Standard breaking capacity
Protection type Adjustable thermal/fixed magnetic (13 x In)
Factory option No circuit-breaker auxiliary or trip contacts
Terminal type Screw connection
Vibration resistance Ops (60068-2-6): 5 G
Shock resistance Transport (60068-2-27): 30 G, 11 ms, all axes
Ambient storage temperature -40 °C
Ambient operating temperature -25 °C
Ambient temperature compensation -20 °C
Site altitude To 2000 N.N.(m)
Moisture heat 40 °C, relative humidity 93 %, 56 d (60068-2-3)-inv
Dry heat 100 °C, relative humidity < 50 %, 7 d (60086-2-2)-inv
Dependence on temperature No current reduction @ 60 °C-inv
Moisture change climate 23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles (600068-2-30)-inv
Pollution degree 3
Utilization category Motor starter: AC-3 (IEC60947-4-1)
Overload protection characteristics IEC 60947-4-1 motor protection
图纸
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
140m-td002_-en-p Technical Data
140M-TD002
类型 资源 出版
Technical Data 140m-td002_-en-p 140M-TD002
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库 Chevron RightChevron Right
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库 Chevron RightChevron Right
Loading
寻找最近经销商
更改位置
EmailEmail
PhonePhone
寻找合作伙伴 Chevron RightChevron Right
Motor Protection Circuit-Breaker
CloseClose
140M-C2E-A40
关闭
打印
Allen-Bradley 140M-C2E-A40 product image
电话:
呼叫
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页 Chevron RightChevron Right
  2. Chevron LeftChevron Left 产品 Chevron RightChevron Right
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose