生命周期状态:
活跃
Description
100S-E MCS-E 安全接触器,40A,AC3 负载,48~130V AC 50/60Hz / 48~130V DC 电子线圈,0 个常开触点 0 个常闭触点标准辅助触点和 2 个常开触点 2 个常闭触点低功率辅助触点
100S-E40KY422C
IEC 40 A Safety Contactor
Serial #:
此产品尚未验证,请{}确认真实性
注册您的产品
生命周期状态:
活跃
Description
100S-E MCS-E 安全接触器,40A,AC3 负载,48~130V AC 50/60Hz / 48~130V DC 电子线圈,0 个常开触点 0 个常闭触点标准辅助触点和 2 个常开触点 2 个常闭触点低功率辅助触点
概述
Physical Characteristics
Mechanical
Compliance & Environment
Standards & Protection
Electrical & Connectivity
Power & Electrical Characteristics
图纸
文档
认证
配件
技术说明
| 唯一产品序列号 |
100S-E40KY422C
|
|---|---|
| 通用产品代码(UPC) |
191326905459
|
| 预计交期 |
47 天
|
| 标准保修期 |
1年 查看详情 |
| 原产国 |
法国
|
Mechanical
| Altitude, max |
3000 m of installation site
|
|---|---|
| Height |
Approx 125.5 mm
|
| Length |
Approx 70 mm
|
| Number of auxiliary contacts as normally closed contact |
2
|
| Number of auxiliary contacts as normally open contact |
2
|
| Number of normally closed contacts as main contact |
0
|
| Number of normally open contacts as main contact |
4
|
| Protection class |
Contactor main contact: IP2X (100-E40...E96 meet IP2X when used with 100-ESC... terminal shrouds.)
|
| Shock resistance |
IEC 60068-2-27
|
| Switching frequency, max |
600 ops/hr, AC-1
|
| Vibration resistance |
IEC 60068-2-6
|
| Weight |
AC/DC (electronic): 0.98 kg (2.16 lbs.)
|
| Width |
Approx 113.5 mm
|
| Ambient temperature |
Storage: -60...80 °C (-76...176 °F)
|
|---|---|
| Climatic withstand |
Category B according to IEC 60947-1, annex Q
|
| DIN fuses (gG) current rating |
Type 2 (per IEC 60947-4-1): 40A @ 690V, 60 kA available fault current
|
|---|---|
| Electromagnetic compatibility |
IEC 60947-1 - Environment A and B (100-E09...E38 only.)
|
| FLA |
60A @ 600V, 3-phase per UL/CSA HVAC applications
|
| Features |
Mirror contact performance on auxiliary contacts, Red N.C. low-power auxiliary contacts used for ftdback circuit, SUVA third-party certification, AC/ DC operating coils, Mirror contact symbol on front
|
| Function |
Non-reversing safety contactor
|
| General purpose current (enclosed) |
34A @ 600V per UL/CSA
|
| LRA |
360 A @ 440-480V AC, 3-phase per UL/CSA HVAC applications
|
| MCCB current rating |
Type 2 (per IEC 60947-4-1): 520A @ 400V, 70 kA available fault current
|
| Main current circuit resistance |
0.21 mΩ
|
| Operating limits, dropout |
(≤0.60) x Us @ DC control
|
| Operating limits, pick-up |
(0.85...1.1) x Us @ 50/60 Hz
|
| Operating time, closing delay |
42 ms
|
| Operating time, opening delay |
17 ms
|
| Optional accessories |
Side-mount auxiliary contacts, Mechanical interlocks IP20 terminal shields
|
| Power dissipation |
7 W per pole at Ie, AC-1, 400V
|
| Rated control supply voltage at AC 50 Hz |
250 V
|
| Rated control supply voltage at AC 60 Hz |
250 V
|
| Rated control supply voltage at DC |
250 V
|
| Rated impulse voltage withstand (Uimp) |
6 kV
|
| Rated isolation voltage (Ui) |
690V per IEC
|
| Rated operational current (Ie) |
70A @ 690V, AC-1 active power load (50/60 Hz), ambient temperature 40 °C (104 °F)
|
| Rated operational current and power |
5Hp @ 230V AC, 500000 electrical ops, 1-phase per UL/CSA elevator duty
|
| Rated operational current and power (enclosed) |
7.5Hp @ 240V, 1-phase per UL/CSA
|
| Rated operational power (Pe) |
84 kW @ 690V, AC-1 active power load (50/60 Hz), ambient temperature 40 °C (104 °F)
|
| Rated voltage (Ue) |
24V @ 48V, 110V @ 220V, 440V DC
|
| Rating for switching AC motors |
3-poles: 40Hp @ 575V, AC-2, AC-3 (60 Hz)
|
| Short time withstand (Icw) |
3-pole: 600A @ 10s (40 °C)
|
| Standard coil, hold-in |
4VA/2 W @ 48...130V AC/DC
|
| Standard coil, pick-up |
25VA/25 W @ 48...130V AC/DC
|
| Switching of DC loads |
3-poles in series: 70A @ 220V (Shunt-wound motors starting, reverse current breaking, reversing, stepping DC-3 at 60 °C)
|
| Switching of lighting loads |
Tungsten lA: 65A @ 600V, 3-phase (break all lines) per UL/CSA
|
| Switching of power transformers |
Apparent power: 87 kVA @ 600V @ 60Hz (n = 15)
|
| Total power dissipation |
10.1 W at Ie, AC-3, 400V, AC/DC control (120-250V)
|
| Type of electrical connection of main circuit |
Screw connection
|
| UL class J and CSA HRCI-J fuses rating |
Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 150A @ 600V, 100 kA available fault current
|
| UL class RK5 fuses rating |
Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 150A @ 600V, 5 kA available fault current
|
| UL inverse-time circuit breaker |
Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 250A @ 600V, 5 kA available fault current
|
| Voltage type for actuating |
AC/DC
|
| 基本信息 | 出版 |
|---|---|
| Product Cutsheet | -- |
| 技术数据 | 出版 |
|---|---|
| 100-td013_-en-p | 100-TD013 |
- China CCC
- UL Listed
- Australian RCM
- CE
- Eurasion Economic Community
- Korean KC
- Registro Italiano Navale
- SUVA LVD Type Approval
- MOROCCO DOC
截至 2026-07-09,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。
正在查找认证文件?
请浏览我们内容详尽的资料库,查看该产品及其他产品的认证信息。
法规信息
| 欧盟进口商地址 |
Rockwell Automation N.V |
|---|---|
| 欧盟授权代表地址 |
Rockwell Automation N.V |
每页项目:
| 技术说明 |
|---|
概述
| 唯一产品序列号 |
100S-E40KY422C
|
|---|---|
| 通用产品代码(UPC) |
191326905459
|
| 预计交期 |
47 天
|
| 标准保修期 |
1年 查看详情 |
| 原产国 |
法国
|
Physical Characteristics
Mechanical
| Altitude, max |
3000 m of installation site
|
|---|---|
| Height |
Approx 125.5 mm
|
| Length |
Approx 70 mm
|
| Number of auxiliary contacts as normally closed contact |
2
|
| Number of auxiliary contacts as normally open contact |
2
|
| Number of normally closed contacts as main contact |
0
|
| Number of normally open contacts as main contact |
4
|
| Protection class |
Contactor main contact: IP2X (100-E40...E96 meet IP2X when used with 100-ESC... terminal shrouds.)
|
| Shock resistance |
IEC 60068-2-27
|
| Switching frequency, max |
600 ops/hr, AC-1
|
| Vibration resistance |
IEC 60068-2-6
|
| Weight |
AC/DC (electronic): 0.98 kg (2.16 lbs.)
|
| Width |
Approx 113.5 mm
|
Compliance & Environment
| Ambient temperature |
Storage: -60...80 °C (-76...176 °F)
|
|---|---|
| Climatic withstand |
Category B according to IEC 60947-1, annex Q
|
Electrical & Connectivity
| DIN fuses (gG) current rating |
Type 2 (per IEC 60947-4-1): 40A @ 690V, 60 kA available fault current
|
|---|---|
| Electromagnetic compatibility |
IEC 60947-1 - Environment A and B (100-E09...E38 only.)
|
| FLA |
60A @ 600V, 3-phase per UL/CSA HVAC applications
|
| Features |
Mirror contact performance on auxiliary contacts, Red N.C. low-power auxiliary contacts used for ftdback circuit, SUVA third-party certification, AC/ DC operating coils, Mirror contact symbol on front
|
| Function |
Non-reversing safety contactor
|
| General purpose current (enclosed) |
34A @ 600V per UL/CSA
|
| LRA |
360 A @ 440-480V AC, 3-phase per UL/CSA HVAC applications
|
| MCCB current rating |
Type 2 (per IEC 60947-4-1): 520A @ 400V, 70 kA available fault current
|
| Main current circuit resistance |
0.21 mΩ
|
| Operating limits, dropout |
(≤0.60) x Us @ DC control
|
| Operating limits, pick-up |
(0.85...1.1) x Us @ 50/60 Hz
|
| Operating time, closing delay |
42 ms
|
| Operating time, opening delay |
17 ms
|
| Optional accessories |
Side-mount auxiliary contacts, Mechanical interlocks IP20 terminal shields
|
| Power dissipation |
7 W per pole at Ie, AC-1, 400V
|
| Rated control supply voltage at AC 50 Hz |
250 V
|
| Rated control supply voltage at AC 60 Hz |
250 V
|
| Rated control supply voltage at DC |
250 V
|
| Rated impulse voltage withstand (Uimp) |
6 kV
|
| Rated isolation voltage (Ui) |
690V per IEC
|
| Rated operational current (Ie) |
70A @ 690V, AC-1 active power load (50/60 Hz), ambient temperature 40 °C (104 °F)
|
| Rated operational current and power |
5Hp @ 230V AC, 500000 electrical ops, 1-phase per UL/CSA elevator duty
|
| Rated operational current and power (enclosed) |
7.5Hp @ 240V, 1-phase per UL/CSA
|
| Rated operational power (Pe) |
84 kW @ 690V, AC-1 active power load (50/60 Hz), ambient temperature 40 °C (104 °F)
|
| Rated voltage (Ue) |
24V @ 48V, 110V @ 220V, 440V DC
|
| Rating for switching AC motors |
3-poles: 40Hp @ 575V, AC-2, AC-3 (60 Hz)
|
| Short time withstand (Icw) |
3-pole: 600A @ 10s (40 °C)
|
| Standard coil, hold-in |
4VA/2 W @ 48...130V AC/DC
|
| Standard coil, pick-up |
25VA/25 W @ 48...130V AC/DC
|
| Switching of DC loads |
3-poles in series: 70A @ 220V (Shunt-wound motors starting, reverse current breaking, reversing, stepping DC-3 at 60 °C)
|
| Switching of lighting loads |
Tungsten lA: 65A @ 600V, 3-phase (break all lines) per UL/CSA
|
| Switching of power transformers |
Apparent power: 87 kVA @ 600V @ 60Hz (n = 15)
|
| Total power dissipation |
10.1 W at Ie, AC-3, 400V, AC/DC control (120-250V)
|
| Type of electrical connection of main circuit |
Screw connection
|
| UL class J and CSA HRCI-J fuses rating |
Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 150A @ 600V, 100 kA available fault current
|
| UL class RK5 fuses rating |
Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 150A @ 600V, 5 kA available fault current
|
| UL inverse-time circuit breaker |
Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 250A @ 600V, 5 kA available fault current
|
| Voltage type for actuating |
AC/DC
|
文档
|
Product Cutsheet
基本信息
-- |
|
100-td013_-en-p
技术数据
100-TD013 |
| 基本信息 | 出版 |
|---|---|
| Product Cutsheet | -- |
| 技术数据 | 出版 |
| 100-td013_-en-p | 100-TD013 |
认证
- China CCC
- UL Listed
- Australian RCM
- CE
- Eurasion Economic Community
- Korean KC
- Registro Italiano Navale
- SUVA LVD Type Approval
- MOROCCO DOC
截至 2026-07-09,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。
正在查找认证文件?
请浏览我们内容详尽的资料库,查看该产品及其他产品的认证信息。
法规信息
| 欧盟进口商地址 |
Rockwell Automation N.V |
|---|---|
| 欧盟授权代表地址 |
Rockwell Automation N.V |
配件
每页项目:
技术说明
| 技术说明 |
|---|
基于制造地点的多个原产国
IEC 40 A Safety Contactor
100S-E40KY422C
关闭
打印