Loading
Allen-Bradley 100S-E16KY23C product image
Allen Bradley
100S-E16KY23C

IEC 16 A Safety Contactor

PrintPrint
打印
EmailEmail
共享
Product RegistrationProduct Registration
QR code
Allen-Bradley 100S-E16KY23C product image
Allen Bradley
生命周期状态: 活跃
生命周期状态: 活跃
添加到BoM
  • 寻找支持
Technical Specifications
Drawings
Documents
Certifications
Accessories
Technotes
Number of auxiliary contacts as normally open contact 2
Number of auxiliary contacts as normally closed contact 3
Vibration resistance IEC 60068-2-6
Shock resistance IEC 60068-2-27
Altitude, max 3000 m of installation site
Switching frequency, max 600 ops/hr, AC-1
Weight AC/DC (electronic): 0.43 kg (0.95 lbs.)
Protection class Contactor main contact: IP2X
Dimensions, approx Length x height x width: 45 x 86 x 77 mm (1.77 x 3.39 x 3.03 in)
Voltage type for actuating AC/DC
Rated control supply voltage at AC 50 Hz 48 V
Rated control supply voltage at AC 60 Hz 48 V
Rated control supply voltage at DC 48 V
Type of electrical connection of main circuit Screw connection
Rated impulse voltage withstand (Uimp) 6 kV
Operating time, closing delay 40 ms
Operating time, opening delay 11 ms
Main current circuit resistance 0.36 mΩ
Rated isolation voltage (Ui) 690V per IEC
Function Non-reversing safety contactor
Standard coil, pick-up 50VA/50 W @ 48...130V AC/DC
Standard coil, hold-in 2.2VA/2 W @ 48...130V AC/DC
General purpose current (enclosed) 20A @ 600V per UL/CSA
Power dissipation 1.2 W per pole at Ie, AC-1, 400V
Short time withstand (Icw) 3-pole: 80A @ 30s (40 °C)
FLA 30A @ 600V, 3-phase per UL/CSA HVAC applications
Rated operational current and power (enclosed) 5 Hp @ 220-240V, 3-phase per UL/CSA
LRA 180 A @ 440-480V AC, 3-phase per UL/CSA HVAC applications
Electromagnetic compatibility IEC 60947-1 - Environment A and B (100-E09...E38 only.)
Total power dissipation 3.05 W at Ie, AC-3, 400V, AC/DC control (120-250V)
Operating limits, dropout (≤0.60) x Us @ DC control
Rating for switching AC motors 3-poles: 9 kW @ 690V, AC-2, AC-3 (50 Hz)
Operating limits, pick-up (0.85...1.1) x Us @ 50/60 Hz
MCCB current rating Type 2 (per IEC 60947-4-1): 28A @ 400V, 70 kA available fault current
DIN fuses (gG) current rating Type 2 (per IEC 60947-4-1): 35A @ 400V, 100 kA available fault current
Rated voltage (Ue) 24V @ 48V, 110V @ 220V, 440V DC
Switching of lighting loads Tungsten lA: 30A @ 600V, 3-phase (break all lines) per UL/CSA
UL class RK5 fuses rating Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60A @ 600V, 5 kA available fault current
Rated operational current (Ie) 3-poles: 30A @ 40°C, AC-1 (690V)
UL class J and CSA HRCI-J fuses rating Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60A @ 600V, 100 kA available fault current
UL inverse-time circuit breaker Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60A @ 600V, 10 kA available fault current
Switching of power transformers Apparent power: 9 kVA @ 208V @ 60Hz (n = 20)
Rated operational power (Pe) 9 kW @ 690V, AC-2, AC-3 switching of 3-phase motors (50 Hz), ambient temperature 60 °C (140 °F)
Switching of DC loads 3-poles in series: 30A @ 220V (Shunt-wound motors starting, reverse current breaking, reversing, stepping DC-3 at 60 °C)
Optional accessories Side-mount auxiliary contacts, Mechanical interlocks
Features Mirror contact performance on auxiliary contacts, Red N.C. low-power auxiliary contacts used for ftdback circuit, SUVA third-party certification, AC/ DC operating coils, Mirror contact symbol on front
Climatic withstand Category B according to IEC 60947-1, annex Q
Ambient temperature Storage: -60...80 °C (-76...176 °F)
Coil insulation class Class F per IEC 60947-4-1
图纸
3D STP (STEP) Model Download (ZIP)
图纸
3D STP (STEP) Model Download (ZIP)
类型 资源 出版
General Product Cutsheet --
Technical Data 100-td013_-en-p 100-TD013
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库 Chevron RightChevron Right
China CCC UL Listed Australian RCM Eurasion Economic Community Korean KC
  • China CCC
  • UL Listed
  • Australian RCM
  • Eurasion Economic Community
  • Korean KC
  • CE
  • Registro Italiano Navale
  • SUVA LVD Type Approval
  • MOROCCO DOC

This product was certified with the above certifications as of 2025-09-09. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

每页项目:
1-1 关于 1
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库 Chevron RightChevron Right
技术规格
Number of auxiliary contacts as normally open contact 2
Number of auxiliary contacts as normally closed contact 3
Vibration resistance IEC 60068-2-6
Shock resistance IEC 60068-2-27
Altitude, max 3000 m of installation site
Switching frequency, max 600 ops/hr, AC-1
Weight AC/DC (electronic): 0.43 kg (0.95 lbs.)
Protection class Contactor main contact: IP2X
Dimensions, approx Length x height x width: 45 x 86 x 77 mm (1.77 x 3.39 x 3.03 in)
Voltage type for actuating AC/DC
Rated control supply voltage at AC 50 Hz 48 V
Rated control supply voltage at AC 60 Hz 48 V
Rated control supply voltage at DC 48 V
Type of electrical connection of main circuit Screw connection
Rated impulse voltage withstand (Uimp) 6 kV
Operating time, closing delay 40 ms
Operating time, opening delay 11 ms
Main current circuit resistance 0.36 mΩ
Rated isolation voltage (Ui) 690V per IEC
Function Non-reversing safety contactor
Standard coil, pick-up 50VA/50 W @ 48...130V AC/DC
Standard coil, hold-in 2.2VA/2 W @ 48...130V AC/DC
General purpose current (enclosed) 20A @ 600V per UL/CSA
Power dissipation 1.2 W per pole at Ie, AC-1, 400V
Short time withstand (Icw) 3-pole: 80A @ 30s (40 °C)
FLA 30A @ 600V, 3-phase per UL/CSA HVAC applications
Rated operational current and power (enclosed) 5 Hp @ 220-240V, 3-phase per UL/CSA
LRA 180 A @ 440-480V AC, 3-phase per UL/CSA HVAC applications
Electromagnetic compatibility IEC 60947-1 - Environment A and B (100-E09...E38 only.)
Total power dissipation 3.05 W at Ie, AC-3, 400V, AC/DC control (120-250V)
Operating limits, dropout (≤0.60) x Us @ DC control
Rating for switching AC motors 3-poles: 9 kW @ 690V, AC-2, AC-3 (50 Hz)
Operating limits, pick-up (0.85...1.1) x Us @ 50/60 Hz
MCCB current rating Type 2 (per IEC 60947-4-1): 28A @ 400V, 70 kA available fault current
DIN fuses (gG) current rating Type 2 (per IEC 60947-4-1): 35A @ 400V, 100 kA available fault current
Rated voltage (Ue) 24V @ 48V, 110V @ 220V, 440V DC
Switching of lighting loads Tungsten lA: 30A @ 600V, 3-phase (break all lines) per UL/CSA
UL class RK5 fuses rating Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60A @ 600V, 5 kA available fault current
Rated operational current (Ie) 3-poles: 30A @ 40°C, AC-1 (690V)
UL class J and CSA HRCI-J fuses rating Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60A @ 600V, 100 kA available fault current
UL inverse-time circuit breaker Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60A @ 600V, 10 kA available fault current
Switching of power transformers Apparent power: 9 kVA @ 208V @ 60Hz (n = 20)
Rated operational power (Pe) 9 kW @ 690V, AC-2, AC-3 switching of 3-phase motors (50 Hz), ambient temperature 60 °C (140 °F)
Switching of DC loads 3-poles in series: 30A @ 220V (Shunt-wound motors starting, reverse current breaking, reversing, stepping DC-3 at 60 °C)
Optional accessories Side-mount auxiliary contacts, Mechanical interlocks
Features Mirror contact performance on auxiliary contacts, Red N.C. low-power auxiliary contacts used for ftdback circuit, SUVA third-party certification, AC/ DC operating coils, Mirror contact symbol on front
Climatic withstand Category B according to IEC 60947-1, annex Q
Ambient temperature Storage: -60...80 °C (-76...176 °F)
Coil insulation class Class F per IEC 60947-4-1
图纸
图纸
3D STP (STEP) Model Download (ZIP)
图纸
3D STP (STEP) Model Download (ZIP)
文档
Product Cutsheet General
--
100-td013_-en-p Technical Data
100-TD013
类型 资源 出版
General Product Cutsheet --
Technical Data 100-td013_-en-p 100-TD013
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库 Chevron RightChevron Right
认证
China CCC UL Listed Australian RCM Eurasion Economic Community Korean KC
  • China CCC
  • UL Listed
  • Australian RCM
  • Eurasion Economic Community
  • Korean KC
  • CE
  • Registro Italiano Navale
  • SUVA LVD Type Approval
  • MOROCCO DOC

This product was certified with the above certifications as of 2025-09-09. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

配件
每页项目:
1-1 关于 1
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库 Chevron RightChevron Right
Loading
寻找最近经销商
更改位置
EmailEmail
PhonePhone
寻找合作伙伴 Chevron RightChevron Right
IEC 16 A Safety Contactor
CloseClose
100S-E16KY23C
关闭
打印
Allen-Bradley 100S-E16KY23C product image
电话:
呼叫
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页 Chevron RightChevron Right
  2. Chevron LeftChevron Left 产品 Chevron RightChevron Right
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose