Loading
  • alt text
alt text
100-K09KY01

IEC 9 A Miniature Contactor

PrintPrint
打印
EmailEmail
共享
Product RegistrationProduct Registration
QR code
Allen-Bradley 100-K09KY01 product image
生命周期状态: 活跃
生命周期状态: 活跃
添加到BoM
  • 寻找支持
技术规格
常规
Mechanical
Electrical
Environmental
图纸
文档
配件
替代产品
技术说明
Auxiliary Contact Cnfg
1 N.C.,3 N.O. Poles
Product Family
IEC
Terminal Type
Screw Type Terminals
Number of normally open contacts as main contact
3
Number of auxiliary contacts as normally closed contact
1
Vibration resistance
IEC 60068-2
Shock resistance
IEC 60068-2
Altitude, max
2000 m (NN) per IEC 60947-4
Lifespan
Mechanical DC control: 15000000 ops
Switching frequency, max
250 ops/h, AC-4 (approximately 200000 ops)
Recommended torque
10.6 in-lb
Weight
DC: 0.2 kg
Conductor cross section
Main contact, 2 conductor: 1...2.5 mm² + 1...4 mm²
Protection class
IP2X
Voltage type for actuating
AC
Rated control supply voltage at AC 50 Hz
48 V
Rated control supply voltage at AC 60 Hz
48 V
Rated control supply voltage at DC
0 V
Type of electrical connection of main circuit
Screw connection
Rated impulse withstand voltage (Uimp)
6 kV
Optional overload relays
Bimetallic
Main current circuit resistance
2.2 mΩ
Power dissipation (all circuits)
0.9 W @ 400V, AC-3, Ie
Rated filament current
9A @ 230/240V, AC-5b
Rated isolation voltage (Ui)
IEC: 690V, UL, CSA: 600V
Switching of motor load
11A @ 400V, AC-7b (50 Hz)
Packaging
Single pack (quantity of 1)
Auxiliary contacts
IP2X
Rated current (enclosed)
9.8A @ 115V, 1-phase per UL/CSA
Rated power (enclosed)
5Hp @ 575V, 3-phase per UL/CSA
Auxiliary contact configuration
1 NC
Capacitance, max
750 µF @ short-circuit current of 10 kA
General purpose current (enclosed)
15 A per UL/CSA
Operating time, closing delay
6...12 ms DC (conventional)
Switching of low inductive loads
20A @ 400V, AC-7a per IEC 61095 (50 Hz)
Short time withstand (Icw)
96A @ 10s, 60 °C
Operating time, opening delay
8...12 ms with integrated diode
Coil consumption, hold-in
Cold 3.0 W, warm 2.6 W DC (conventional)
Coil consumption, pick-up
Cold 3.0 W, warm 2.6 W DC (conventional)
Total power dissipation
DC control: 3.5 W @ 400V, AC-3, Ie
Operating limits, dropout
(0.2...0.75) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Switching of lamps
Gas discharge lA, open: 18A @ 40°C, AC-5a
Insulation class of the coil
Class F per IEC 60085, Class 105 insulation system per UL 508
Rating for switching AC motors
3-poles: 5Hp @ 575V (AC-2, AC-3, AC-4), 3-phase (60 Hz)
Switching of hermetically sealed cooling compressor motors
18A @ 400V, AC-8a (manual reset of overload release (50 Hz))
Operating limits, pick-up
(0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz
UL class K5 and RK5 fuses rating
40A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
DIN fuses (gG, gL) current rating
Type 2 (per IEC 60947-4-1): 20A @ 400V, 50 kA available fault current
Rated operational current (Ie)
8.9A @ 690V, Star-Delta starting (50 Hz)
UL class J and CSA HRCI-J fuses rating
30A @ 600V, 50 kA available fault current per UL 508 and CSA 22.2 No. 14
Switching of power transformers
Apparent power: 4 kVA @ 500V, AC-6a @ 50Hz (n = 30)
Rated operational power (Pe)
8.3 kW @ 240V, AC-1 (50 Hz), ambient temperature 40 °C
Switching of DC loads
3-poles in series: 9A @ 48/60V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C)
Optional accessories
Front-mount auxiliary contacts, surge suppressors, electronic timers, mechanical interlocks
Features
Mini-contactors, Uniform panel mounting dimensions, Panel mounting or mounting on 35 mm DIN Rail, Made of environmentally friendly materials
UL class CC and CSA HRCI-MISC fuses rating
30A @ 600V, 50 kA available fault current per UL 508 and CSA 22.2 No. 14
Climatic withstand
IEC 60068-2-30
Ambient temperature
Storage: -55...80 (-67...176)
图纸
3-Dimensional STEP model (STP) 下载 (ZIP)
Product Drawing Drawing (DXF)
图纸
3-Dimensional STEP model (STP) 下载 (ZIP)
Product Drawing Drawing (DXF)
类型 资源 出版
Technical Data 140mp-td002_-en-p 140MP-TD002
常规 Circuit Protection Device and SCCR Tables --
常规 Technical Detail 100-TD013
常规 Product Cutsheet --
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
每页项目:
1-1 关于 1
每页项目:
1-1 关于 1
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
技术规格
Auxiliary Contact Cnfg
1 N.C.,3 N.O. Poles
Product Family
IEC
Terminal Type
Screw Type Terminals
Number of normally open contacts as main contact
3
Number of auxiliary contacts as normally closed contact
1
Vibration resistance
IEC 60068-2
Shock resistance
IEC 60068-2
Altitude, max
2000 m (NN) per IEC 60947-4
Lifespan
Mechanical DC control: 15000000 ops
Switching frequency, max
250 ops/h, AC-4 (approximately 200000 ops)
Recommended torque
10.6 in-lb
Weight
DC: 0.2 kg
Conductor cross section
Main contact, 2 conductor: 1...2.5 mm² + 1...4 mm²
Protection class
IP2X
Voltage type for actuating
AC
Rated control supply voltage at AC 50 Hz
48 V
Rated control supply voltage at AC 60 Hz
48 V
Rated control supply voltage at DC
0 V
Type of electrical connection of main circuit
Screw connection
Rated impulse withstand voltage (Uimp)
6 kV
Optional overload relays
Bimetallic
Main current circuit resistance
2.2 mΩ
Power dissipation (all circuits)
0.9 W @ 400V, AC-3, Ie
Rated filament current
9A @ 230/240V, AC-5b
Rated isolation voltage (Ui)
IEC: 690V, UL, CSA: 600V
Switching of motor load
11A @ 400V, AC-7b (50 Hz)
Packaging
Single pack (quantity of 1)
Auxiliary contacts
IP2X
Rated current (enclosed)
9.8A @ 115V, 1-phase per UL/CSA
Rated power (enclosed)
5Hp @ 575V, 3-phase per UL/CSA
Auxiliary contact configuration
1 NC
Capacitance, max
750 µF @ short-circuit current of 10 kA
General purpose current (enclosed)
15 A per UL/CSA
Operating time, closing delay
6...12 ms DC (conventional)
Switching of low inductive loads
20A @ 400V, AC-7a per IEC 61095 (50 Hz)
Short time withstand (Icw)
96A @ 10s, 60 °C
Operating time, opening delay
8...12 ms with integrated diode
Coil consumption, hold-in
Cold 3.0 W, warm 2.6 W DC (conventional)
Coil consumption, pick-up
Cold 3.0 W, warm 2.6 W DC (conventional)
Total power dissipation
DC control: 3.5 W @ 400V, AC-3, Ie
Operating limits, dropout
(0.2...0.75) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Switching of lamps
Gas discharge lA, open: 18A @ 40°C, AC-5a
Insulation class of the coil
Class F per IEC 60085, Class 105 insulation system per UL 508
Rating for switching AC motors
3-poles: 5Hp @ 575V (AC-2, AC-3, AC-4), 3-phase (60 Hz)
Switching of hermetically sealed cooling compressor motors
18A @ 400V, AC-8a (manual reset of overload release (50 Hz))
Operating limits, pick-up
(0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz
UL class K5 and RK5 fuses rating
40A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
DIN fuses (gG, gL) current rating
Type 2 (per IEC 60947-4-1): 20A @ 400V, 50 kA available fault current
Rated operational current (Ie)
8.9A @ 690V, Star-Delta starting (50 Hz)
UL class J and CSA HRCI-J fuses rating
30A @ 600V, 50 kA available fault current per UL 508 and CSA 22.2 No. 14
Switching of power transformers
Apparent power: 4 kVA @ 500V, AC-6a @ 50Hz (n = 30)
Rated operational power (Pe)
8.3 kW @ 240V, AC-1 (50 Hz), ambient temperature 40 °C
Switching of DC loads
3-poles in series: 9A @ 48/60V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C)
Optional accessories
Front-mount auxiliary contacts, surge suppressors, electronic timers, mechanical interlocks
Features
Mini-contactors, Uniform panel mounting dimensions, Panel mounting or mounting on 35 mm DIN Rail, Made of environmentally friendly materials
UL class CC and CSA HRCI-MISC fuses rating
30A @ 600V, 50 kA available fault current per UL 508 and CSA 22.2 No. 14
Climatic withstand
IEC 60068-2-30
Ambient temperature
Storage: -55...80 (-67...176)
图纸
图纸
3-Dimensional STEP model (STP) 下载 (ZIP)
Product Drawing Drawing (DXF)
图纸
3-Dimensional STEP model (STP) 下载 (ZIP)
Product Drawing Drawing (DXF)
文档
140mp-td002_-en-p Technical Data
140MP-TD002
Circuit Protection Device and SCCR Tables 常规
--
Technical Detail 常规
100-TD013
Product Cutsheet 常规
--
类型 资源 出版
Technical Data 140mp-td002_-en-p 140MP-TD002
常规 Circuit Protection Device and SCCR Tables --
常规 Technical Detail 100-TD013
常规 Product Cutsheet --
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
配件
每页项目:
1-1 关于 1
替代产品
每页项目:
1-1 关于 1
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
Loading
寻找最近经销商
Contact your distributor in {0}
更改位置
EmailEmail
PhonePhone
寻找合作伙伴
IEC 9 A Miniature Contactor
CloseClose
100-K09KY01
关闭
打印
Allen-Bradley 100-K09KY01 product image
电话:
呼叫
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页
  2. Chevron LeftChevron Left 产品
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose