Loading
View all IEC Standard Contactors
  • alt text
alt text
100-D630ED11

IEC 630 A MCS D Contactor

PrintPrint
打印
EmailEmail
共享
Product RegistrationProduct Registration
二维码
Allen-Bradley 100-D630ED11 product image
生命周期状态: 停止
ErrorsErrors
Rockwell Automation announces that as of March 31, 2019, the IEC 630 A MCS D Contactor will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期: March 31, 2019 替代类别: Engineering Replacement 替代产品: 100-E580ED11 [https://www.rockwellautomation.com.cn/products/details.100-E580ED11.html]
产品概览
可享更换服务
生命周期状态: 停止
ErrorsErrors
Rockwell Automation announces that as of March 31, 2019, the IEC 630 A MCS D Contactor will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期: March 31, 2019 替代类别: Engineering Replacement 替代产品: 100-E580ED11 [https://www.rockwellautomation.com.cn/products/details.100-E580ED11.html]
产品概览
可享更换服务
添加到BoM
  • 寻找支持
技术规格
基本信息
Electrical
Mechanical
Environmental
Construction
文档
替代产品
技术说明
Contact Configuration
1 N.O. 1 N.C.
Maximum Ampere Rating
630 A
Sub Brand
IEC
Voltage type for actuating
AC/DC
Rated control supply voltage at AC 50 Hz
110 V
Rated control supply voltage at AC 60 Hz
110 V
Rated control supply voltage at DC
110 V
Type of electrical connection of main circuit
Screw connection
Rated impulse withstand voltage (Uimp)
12 kV
Current (Ie), max
630 A
Optional overload relays
Electronic
Current rating
115 A
Main current circuit resistance
0.19 mΩ
Rated isolation voltage (Ui)
600V @ UL, CSA
Auxiliary contacts
IP20 IEC 60529/DIN 40050
Rated power (enclosed)
600Hp @ 575V, 3-phase per UL/CSA
General purpose current (enclosed)
630 A per UL/CSA
Power dissipation
226.2 W @ 400V, AC-3, Ie
Operating time
70…145 ms @ DC, closing delay
Short time withstand (Icw)
6300A @ 10s, 60 °C (140 °F)
Coil consumption, hold-in
33VA/30 W @ 50 Hz, 60 Hz, 50/60 Hz
Coil consumption, pick-up
1980 W @ DC control
Total power dissipation
DC control: 256.2 W @ 400V, AC-3, Ie
Operating limits, dropout
(0.1...0.8) x Us @ DC control
Insulation class of the coil
Class B per VDE 0660, table 22
Rating for switching AC motors
600Hp @ 575V, 60 Hz, 3-phase (AC-2, AC-3)
Operating limits, pick-up
(0.85...1.1) x Us @ DC control
BS88 fuses current rating
TBD
UL class L fuses rating
2000A @ 600V, 35 kA available fault current per UL 508 and CSA 22.2 No. 14
Rated voltage (Ue)
690V @ AC, 50/60 Hz
DIN fuses (gG, gL) current rating
TBD
Coil voltage
110-130V 50/60 Hz/110-130V DC electronic coil w/ electronic interface
Rated operational current (Ie)
800A @ 690V, AC-1 (50 Hz), ambient temperature 40 °C
UL inverse-time circuit breaker
1200A @ 600V, 30 kA available fault current per UL listed combination
Rated operational power (Pe)
956 kW @ 690V, AC-1 (50 Hz), ambient temperature 40 °C
Optional accessories
Side-mount auxiliary contacts, surge suppressors, IP20 terminal blocks, terminal shields, terminal covers, connecting components, terminal lugs, mechanical/electrical interlocks
Features
Panel mounting only, made of environmentally friendly materials, AC or DC coil control (conventional or electronic), integrated PLC interface (electronic coil)
Contacts
3 power poles with external NO and NC side-mounted auxiliary contact, optional side-mounted 2-pole external auxiliary contact blocks
Conventional coil type
Yes
Electronic-EI coil type
Yes
Rated coil frequency
AC 50 Hz, 50/60 Hz DC
Screw terminals
Threaded
Vibration resistance
IEC 60068-2-6
Shock resistance
IEC 60068-2-27
Cross section per UL/CSA
(2X) 2/0...500 MCM
Lifespan
Mechanical DC control: 2000000 ops
Recommended torque
68 Nm
Weight
Non-reverse: 28.6 kg @ DC
Conductor cross section
Main contact, s maximum: 16 mm
Protection class
IP00 IEC 60529/DIN 40050
Altitude of installation site, max
2000 m (NN), per IEC60947-1
Protection against accidental contact
Finger-and back-of-hand proof per VDE 0106, part 100
Ambient temperature
Storage: -40…80 °C
Single contactor cover
IP10 IEC 60529/DIN 40050
Contactor with frame terminal block
IP20 IEC 60529/DIN 40050
安装说明 出版
100-in042_-mu-e 100-IN042
技术数据 出版
100-td013_-en-p 100-TD013
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
每页项目:
1-1 关于 1
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
技术规格
Contact Configuration
1 N.O. 1 N.C.
Maximum Ampere Rating
630 A
Sub Brand
IEC
Voltage type for actuating
AC/DC
Rated control supply voltage at AC 50 Hz
110 V
Rated control supply voltage at AC 60 Hz
110 V
Rated control supply voltage at DC
110 V
Type of electrical connection of main circuit
Screw connection
Rated impulse withstand voltage (Uimp)
12 kV
Current (Ie), max
630 A
Optional overload relays
Electronic
Current rating
115 A
Main current circuit resistance
0.19 mΩ
Rated isolation voltage (Ui)
600V @ UL, CSA
Auxiliary contacts
IP20 IEC 60529/DIN 40050
Rated power (enclosed)
600Hp @ 575V, 3-phase per UL/CSA
General purpose current (enclosed)
630 A per UL/CSA
Power dissipation
226.2 W @ 400V, AC-3, Ie
Operating time
70…145 ms @ DC, closing delay
Short time withstand (Icw)
6300A @ 10s, 60 °C (140 °F)
Coil consumption, hold-in
33VA/30 W @ 50 Hz, 60 Hz, 50/60 Hz
Coil consumption, pick-up
1980 W @ DC control
Total power dissipation
DC control: 256.2 W @ 400V, AC-3, Ie
Operating limits, dropout
(0.1...0.8) x Us @ DC control
Insulation class of the coil
Class B per VDE 0660, table 22
Rating for switching AC motors
600Hp @ 575V, 60 Hz, 3-phase (AC-2, AC-3)
Operating limits, pick-up
(0.85...1.1) x Us @ DC control
BS88 fuses current rating
TBD
UL class L fuses rating
2000A @ 600V, 35 kA available fault current per UL 508 and CSA 22.2 No. 14
Rated voltage (Ue)
690V @ AC, 50/60 Hz
DIN fuses (gG, gL) current rating
TBD
Coil voltage
110-130V 50/60 Hz/110-130V DC electronic coil w/ electronic interface
Rated operational current (Ie)
800A @ 690V, AC-1 (50 Hz), ambient temperature 40 °C
UL inverse-time circuit breaker
1200A @ 600V, 30 kA available fault current per UL listed combination
Rated operational power (Pe)
956 kW @ 690V, AC-1 (50 Hz), ambient temperature 40 °C
Optional accessories
Side-mount auxiliary contacts, surge suppressors, IP20 terminal blocks, terminal shields, terminal covers, connecting components, terminal lugs, mechanical/electrical interlocks
Features
Panel mounting only, made of environmentally friendly materials, AC or DC coil control (conventional or electronic), integrated PLC interface (electronic coil)
Contacts
3 power poles with external NO and NC side-mounted auxiliary contact, optional side-mounted 2-pole external auxiliary contact blocks
Conventional coil type
Yes
Electronic-EI coil type
Yes
Rated coil frequency
AC 50 Hz, 50/60 Hz DC
Screw terminals
Threaded
Vibration resistance
IEC 60068-2-6
Shock resistance
IEC 60068-2-27
Cross section per UL/CSA
(2X) 2/0...500 MCM
Lifespan
Mechanical DC control: 2000000 ops
Recommended torque
68 Nm
Weight
Non-reverse: 28.6 kg @ DC
Conductor cross section
Main contact, s maximum: 16 mm
Protection class
IP00 IEC 60529/DIN 40050
Altitude of installation site, max
2000 m (NN), per IEC60947-1
Protection against accidental contact
Finger-and back-of-hand proof per VDE 0106, part 100
Ambient temperature
Storage: -40…80 °C
Single contactor cover
IP10 IEC 60529/DIN 40050
Contactor with frame terminal block
IP20 IEC 60529/DIN 40050
文档
100-in042_-mu-e 安装说明
100-IN042
100-td013_-en-p 技术数据
100-TD013
安装说明 出版
100-in042_-mu-e 100-IN042
技术数据 出版
100-td013_-en-p 100-TD013
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
替代产品
每页项目:
1-1 关于 1
技术说明
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
寻找最近经销商
请联系您在{0}的经销商
更改位置
EmailEmail
PhonePhone
寻找合作伙伴
IEC 630 A MCS D Contactor
CloseClose
100-D630ED11
关闭
打印
Allen-Bradley 100-D630ED11 product image
电话:
呼叫
Rockwell Automation Home
Copyright ©2026 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页
  2. Chevron LeftChevron Left 产品
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose