Loading
Allen-Bradley 100-D210EZJ11 product image
Allen Bradley

IEC 210 A MCS D Contactor

PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Catalog #: 100-D210EZJ11
Lifecycle status: Discontinued
ErrorsErrors
Rockwell Automation announces that as of March 31, 2019, the IEC 210 A MCS D Contactor will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s).
Discontinued Date: March 31, 2019 Replacement Category: Engineering Replacement 替换产品: 100-E205KJ11 [https://www.rockwellautomation.com.cn/products/details.100-E205KJ11.html]
Allen-Bradley 100-D210EZJ11 product image
Allen Bradley
PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Lifecycle status: Discontinued
ErrorsErrors
Rockwell Automation announces that as of March 31, 2019, the IEC 210 A MCS D Contactor will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s).
Discontinued Date: March 31, 2019 Replacement Category: Engineering Replacement 替换产品: 100-E205KJ11 [https://www.rockwellautomation.com.cn/products/details.100-E205KJ11.html]
Add to BoM
  • Get Support
Repair Options
CloseClose
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
Schedule a repair Request repair documentation Repair terms and conditions
Technical Specifications
Documents
Technotes
Auxiliary Contact Cnfg 1 N.O. 1 N.C.
Coil Code 24V DC
Maximum Ampere Rating 210 A
Product Family IEC
Voltage type for actuating DC
Rated control supply voltage at DC 24 V
Type of electrical connection of main circuit Screw connection
Rated impulse withstand voltage (Uimp) 12 kV
Current (Ie), max 210 A
Optional overload relays Electronic
Current rating 115 A
Main current circuit resistance 0.22 mΩ
Rated filament current 210A @ 230/240V, AC-5b
Rated isolation voltage (Ui) 600V @ UL, CSA
Auxiliary contacts IP20 IEC 60529/DIN 40050
Rated power (enclosed) 75Hp @ 230V, 3-phase per UL/CSA
Rated operational current for contactor 156A @ 460V, elevator duty (UL/CSA)
Rated power for contactor 50Hp @ 230V, elevator duty (UL/CSA)
General purpose current (enclosed) 300 A per UL/CSA
Power dissipation 29.4 W @ 400V, AC-3, Ie
Operating time 35…110 ms @ DC, closing delay
Short time withstand (Icw) 2360A @ 10s, 60 °C (140 °F)
Coil consumption, hold-in 6 W @ DC control
Coil consumption, pick-up 380VA/240 W @ 50 Hz, 60 Hz, 50/60 Hz
Switching of 3-phase Capacitors Single capacitor: 98 kVAR @ 230V, AC-6b, 60 Hz, 40 °C
Total power dissipation DC control: 35.4 W @ 400V, AC-3, Ie
Operating limits, dropout (0.3...0.5) x Us @ DC control
Switching of lamps Gas discharge lA, open: 315A @ 40°C (104 °F), AC-5a
Insulation class of the coil Class B per VDE 0660, table 22
Rating for switching AC motors 75Hp @ 230V, 60 Hz, 3-phase (AC-2, AC-3)
Operating limits, pick-up (0.85...1.1) x Us @ DC control
BS88 fuses current rating Type 2 (per IEC 60947-4-1): 355A @ 415V, 65 kA available fault current
UL class K5 and RK5 fuses rating 500A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
Rated voltage (Ue) 690V @ AC, 50/60 Hz
DIN fuses (gG, gL) current rating Type 2 (per IEC 60947-4-1): 400A @ 690V, 50 kA available fault current
Coil voltage 24V DC electronic coil w/ electronic interface
Rated operational current (Ie) 85A @ 690V, AC-4 (approximately 200000 ops)
UL class J and CSA HRCI-J fuses rating Type2 (IEC60947-4-1): 400A @ 100kA available fault current per UL verified combination
UL inverse-time circuit breaker 300A @ 600V, 10 kA available fault current per UL listed combination
Switching of power transformers Apparent power: 91 kVA @ 500V, AC-6a @ 50Hz (n = 30)
Rated operational power (Pe) 80 kW @ 690V, AC-4 (approximately 200000 ops)
Switching of DC loads 3-Poles in series: 300A @ 48/60V (Shunt-wound Motors Starting, reverse current braking, reversing, stepping DC-3 at 60 °C)
Optional accessories Side-mount auxiliary contacts, surge suppressors, IP20 terminal blocks, terminal shields, terminal covers, connecting components, terminal lugs, mechanical/electrical interlocks
Features Panel mounting only, made of environmentally friendly materials, AC or DC coil control (conventional or electronic), integrated PLC interface (electronic coil)
Contacts 3 power poles with external NO and NC side-mounted auxiliary contact, optional side-mounted 2-pole external auxiliary contact blocks
Conventional coil type True
Electronic-EI coil type True
Rated coil frequency AC 50 Hz, 50/60 Hz DC
Frame terminal block conductor cross section, b max 25
Frame terminal block conductor cross section, s top 6
Frame terminal block conductor cross section, s bottom 6
Screw terminals Thru-hole
Conductor cross section, top opening 25
Conductor cross section, bottom opening 25
Vibration resistance IEC 60068-2-6
Shock resistance IEC 60068-2-27
Cross section per UL/CSA 4 AWG...600 MCM @ top
Lifespan Mechanical DC control: 10000000 ops
Switching frequency, max 120 ops/h
Recommended torque 43 Nm
Weight Non-reverse: 7.5 kg @ DC
Conductor cross section Main contact, s maximum: 6 mm
Protection class IP00 IEC 60529/DIN 40050
Altitude of installation site, max 2000 m (NN), per IEC60947-1
Protection against accidental contact Finger-and back-of-hand proof per VDE 0106, part 100
Ambient temperature Storage: -40…80 °C
Single contactor cover IP10 IEC 60529/DIN 40050
Contactor with frame terminal block IP20 IEC 60529/DIN 40050
Sales Info
Repairable NOT_REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 20.5
Lead Time 39
Dimension Width 25.001
Dimension Length 27.0
Stock Status NON_STOCKED
Weight 8.33
Weight Unit KG
Dimension Unit CM
类型 资源 发布
Installation Instructions 100-in042_-mu-e 100-IN042
Technical Data 100-td013_-en-p 100-TD013
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library Chevron RightChevron Right
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Technical Specifications
Auxiliary Contact Cnfg 1 N.O. 1 N.C.
Coil Code 24V DC
Maximum Ampere Rating 210 A
Product Family IEC
Voltage type for actuating DC
Rated control supply voltage at DC 24 V
Type of electrical connection of main circuit Screw connection
Rated impulse withstand voltage (Uimp) 12 kV
Current (Ie), max 210 A
Optional overload relays Electronic
Current rating 115 A
Main current circuit resistance 0.22 mΩ
Rated filament current 210A @ 230/240V, AC-5b
Rated isolation voltage (Ui) 600V @ UL, CSA
Auxiliary contacts IP20 IEC 60529/DIN 40050
Rated power (enclosed) 75Hp @ 230V, 3-phase per UL/CSA
Rated operational current for contactor 156A @ 460V, elevator duty (UL/CSA)
Rated power for contactor 50Hp @ 230V, elevator duty (UL/CSA)
General purpose current (enclosed) 300 A per UL/CSA
Power dissipation 29.4 W @ 400V, AC-3, Ie
Operating time 35…110 ms @ DC, closing delay
Short time withstand (Icw) 2360A @ 10s, 60 °C (140 °F)
Coil consumption, hold-in 6 W @ DC control
Coil consumption, pick-up 380VA/240 W @ 50 Hz, 60 Hz, 50/60 Hz
Switching of 3-phase Capacitors Single capacitor: 98 kVAR @ 230V, AC-6b, 60 Hz, 40 °C
Total power dissipation DC control: 35.4 W @ 400V, AC-3, Ie
Operating limits, dropout (0.3...0.5) x Us @ DC control
Switching of lamps Gas discharge lA, open: 315A @ 40°C (104 °F), AC-5a
Insulation class of the coil Class B per VDE 0660, table 22
Rating for switching AC motors 75Hp @ 230V, 60 Hz, 3-phase (AC-2, AC-3)
Operating limits, pick-up (0.85...1.1) x Us @ DC control
BS88 fuses current rating Type 2 (per IEC 60947-4-1): 355A @ 415V, 65 kA available fault current
UL class K5 and RK5 fuses rating 500A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
Rated voltage (Ue) 690V @ AC, 50/60 Hz
DIN fuses (gG, gL) current rating Type 2 (per IEC 60947-4-1): 400A @ 690V, 50 kA available fault current
Coil voltage 24V DC electronic coil w/ electronic interface
Rated operational current (Ie) 85A @ 690V, AC-4 (approximately 200000 ops)
UL class J and CSA HRCI-J fuses rating Type2 (IEC60947-4-1): 400A @ 100kA available fault current per UL verified combination
UL inverse-time circuit breaker 300A @ 600V, 10 kA available fault current per UL listed combination
Switching of power transformers Apparent power: 91 kVA @ 500V, AC-6a @ 50Hz (n = 30)
Rated operational power (Pe) 80 kW @ 690V, AC-4 (approximately 200000 ops)
Switching of DC loads 3-Poles in series: 300A @ 48/60V (Shunt-wound Motors Starting, reverse current braking, reversing, stepping DC-3 at 60 °C)
Optional accessories Side-mount auxiliary contacts, surge suppressors, IP20 terminal blocks, terminal shields, terminal covers, connecting components, terminal lugs, mechanical/electrical interlocks
Features Panel mounting only, made of environmentally friendly materials, AC or DC coil control (conventional or electronic), integrated PLC interface (electronic coil)
Contacts 3 power poles with external NO and NC side-mounted auxiliary contact, optional side-mounted 2-pole external auxiliary contact blocks
Conventional coil type True
Electronic-EI coil type True
Rated coil frequency AC 50 Hz, 50/60 Hz DC
Frame terminal block conductor cross section, b max 25
Frame terminal block conductor cross section, s top 6
Frame terminal block conductor cross section, s bottom 6
Screw terminals Thru-hole
Conductor cross section, top opening 25
Conductor cross section, bottom opening 25
Vibration resistance IEC 60068-2-6
Shock resistance IEC 60068-2-27
Cross section per UL/CSA 4 AWG...600 MCM @ top
Lifespan Mechanical DC control: 10000000 ops
Switching frequency, max 120 ops/h
Recommended torque 43 Nm
Weight Non-reverse: 7.5 kg @ DC
Conductor cross section Main contact, s maximum: 6 mm
Protection class IP00 IEC 60529/DIN 40050
Altitude of installation site, max 2000 m (NN), per IEC60947-1
Protection against accidental contact Finger-and back-of-hand proof per VDE 0106, part 100
Ambient temperature Storage: -40…80 °C
Single contactor cover IP10 IEC 60529/DIN 40050
Contactor with frame terminal block IP20 IEC 60529/DIN 40050
Sales Info
Repairable NOT_REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 20.5
Lead Time 39
Dimension Width 25.001
Dimension Length 27.0
Stock Status NON_STOCKED
Weight 8.33
Weight Unit KG
Dimension Unit CM
文档
100-in042_-mu-e Installation Instructions
100-IN042
100-td013_-en-p Technical Data
100-TD013
类型 资源 发布
Installation Instructions 100-in042_-mu-e 100-IN042
Technical Data 100-td013_-en-p 100-TD013
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library Chevron RightChevron Right
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Loading
Find your nearest distributor
Change location
EmailEmail
PhonePhone
Find a partner Chevron RightChevron Right
IEC 210 A MCS D Contactor
CloseClose
100-D210EZJ11
关闭
打印
Allen-Bradley 100-D210EZJ11 product image
手机:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页 Chevron RightChevron Right
  2. Chevron LeftChevron Left 产品 Chevron RightChevron Right
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose