Published Date: May 9, 2024
Last updated: August 5, 2025
Revision Number: 1.0
CVSS Score: v3.1: 7.5/10, v4.0: 7.7/10
AFFECTED PRODUCTS AND SOLUTION
Affected Product
|
Affected Versions
|
Corrected in software version
|
FactoryTalk® Historian SE
|
< v9.0
|
v9.01 and later
|
SECURITY ISSUE DETAILS
Rockwell Automation used version 3.1 and 4.0 of the CVSS scoring system to assess the following security issues.
CVE-2023-31274 IMPACT
FactoryTalk® Historian SE utilizes the AVEVA PI Server, which contains a security issue. This could allow an unauthenticated user to cause a partial denial-of-service condition. This happens in the PI Message Subsystem of a PI Server by consuming available memory. This exists in FactoryTalk® Historian SE versions 9.0 and earlier. Use of this issue could cause FactoryTalk® Historian SE to become unavailable. This would requiring a power cycle to recover it.
CVSS Base Score v3.1: 7.5/10
CVSS Vector String: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CVSS Base Score v4.0: 7.7/10
CVSS Vector String: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:N/SI:N/SA:H
CWE: Dependency on Vulnerable third-party Component
CVE-2023-34348 IMPACT
FactoryTalk® Historian SE use the AVEVA PI Server. This contains a security issue that could allow an unauthenticated user to remotely crash the PI Message Subsystem of a PI Server. This would result in a denial-of-service condition. This issue exists in FactoryTalk® Historian SE versions 9.0 and earlier. Use of this could cause FactoryTalk® Historian SE to become unavailable. This requires a power cycle to recover it.
CVSS Base Score v3.1: 7.5/10
CVSS Vector String: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CVSS Base Score v4.0: 7.7/10
CVSS Vector String: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:N/SI:N/SA:H
CWE: Dependency on Vulnerable third-party Component
Known Exploited Vulnerability (KEV) database: No
Users can use Stakeholder-Specific Vulnerability Categorization to create more environment-specific categories.
Mitigations and Workarounds
Customers using the affected software should install FactoryTalk® Historian SE version 9.01 or higher as soon as feasible. For customers unable to upgrade to v9.0, defensive measures are available in the Rockwell article.
-
Customers should use our suggested security best practices to minimize the risks.
ADDITIONAL RESOURCES
Glossary
Denial-of-Service: malicious attempt to overwhelm a web property with traffic in order to disrupt its normal operations
Known Exploited Vulnerability (KEV) database: an official list of security flaws that attackers have actively exploited
PI Message Subsystem: A part of the PI System that handles logging and messaging. IT is responsible for managing PI Logs, which are binary files located in the PI/Log folder on a PI Server or PIPC/Log on clients and interfaced nodes