Width
260 mm
Height
217.83 mm
Depth
166.5 mm
Number of poles
Power circuit: 3
Wire size
Power terminal: (2) #18... AWG (0.8...5.2 mm²) per terminal
Degree of protection (IP)
IP66
Shipping weight, approx
4.6 kg
Power rating
Power terminal: 25A @ 600V AC
Shock
Opsal: 30 G, exceeds IEC 60947-1
Gland plate options
Conduit entry for power and motor (no cable)
Wire strip length
0.35 ±0.01 in (9 ±2 mm)
Vibration
Opsal: 2.5 G @ tested to MIL-STD-810G, exceeds IEC 60947-1
Tightening torque
Power terminal: 10.6 ±2 in-lb (1.2 ±0.2 Nm)
Mechanical life operations
Disconnect: 200000
Disconnect lock out
Maximum of 3/8 in (9.5 mm) diam lock shackle or hasp
Contactor opening delay
8 ms
Contactor closing delay
18 ms
Wire type
Multi-strand copper wire
Disconnect LOTO locks
Up to 2 locks or hasps are supported
Contactor utilization category
AC-1, AC-3, AC-4 per IEC (refer to life load curves)
Altitude
2000 m
Operating temperature
-20 °C
Storage and transportation temperature
-25 °C
Conducted emission
EN 60947-4-1, Class A
Humidity
5...95% (noncondensing)
Surge transient
1 kV (12) L-L, 2 kV (2) L-N (earth)
Radiated emissions
EN 60947-4-1, Class A
Radio frequency electromagnetic field
EN 60947-4-1, 10V/m, 80 MHz...1 GHz, 10V/m, 1.4 GHz...2 GHz
Degree of protection (NEMA)
4
Pollution degree
3
Radio frequency conducted disturbance immunity
10V @ 150kHz...80 MHz
Electrostatic discharge
4 kV contact and 8 kV air
Fast transient
2 kV (power), 2 kV (PE), 1 kV (communications and control)
DHCP timeout
30 s
Web server
HTTP 1.1
Input ON-state current (pin 4)
2.6mA @ 24V DC
Operating dielectric withstand
2000V AC per IEC
Overvoltage category
Power circuit: III
Product type
Full voltage starter
Fuse rating
UL Class fuse (45 A, maximum)
Consume instance (command)
Default of 3 words (instance 150)
Produce instance (status)
Default of 14 words (instance 152)
Insulation voltage (Ui)
Output ratings: rated 2000V AC per IEC
Rated operating current, max
Power circuit: 0.24...3.5A @ 2Hp (1.5 kW)
Rated input operation voltage
24V DC
Input OFF-state current
<1.5 mA
Input OFF-state voltage
5V DC
Operating frequency
Power circuit: 50/60 Hz (±10%)
User options 1
HAND-OFF-AUTO selector keypad
Trip rating
Power circuit: 120% of full load current (FLC) setting
Application in industrial area permitted (SCPD list)
Size per NFPA 70 (NEC) or NFPA 79 for group motor applications
Short circuit coordination
Type 1
Overload type
Power circuit: solid-state I²t
Insulation voltage
Rated 250V AC
Dielectric withstand
Power circuit: 2500V AC per IEC
Concurrent TCP connections
Network connections: maximum of 15 encapsulated messages over both TCP and UDP
RMS symmetrical amperes
5 kA @ 480Y/277 (short circuit current rating)
Power
Control circuit (external source): 6.6 W @ switched and unswitched power supply requirements
Current, nom
Control circuit (external source): 275 mA @ switched and unswitched power supply requirements
Peak inrush
Control circuit (external source): <5 A for 35 ms @ unswitched power supply requirements
Voltage
Control circuit (external source): 19.2...26.4V DC @ unswitched power supply requirements
Trip class
Power circuit: Class 10 (default), 15, 20 with thermal memory retention (see motor overload trip curves)
Current, max
Control circuit (external source): 450 mA @ unswitched power supply requirements
Power, max
Control circuit (external source): 6.6 W + (24V DC x user defined) @ switched and unswitched power supply requirements
Data
Transported over both TCP and UDP
Application in industrial area permitted
Yes
Supporting protocol for EtherNet/IP
Yes
Mains frequency
50/60 Hz
Number of input devices, max
6
Output OFF-state leakage current, max
1 µa
Number of outputs, max
6
Number of configurable digital I/O
6
Input filtering
100 µs
OFF time, min
200 ms
Sockets, max
150
Output supply voltage (switched power)
A1/A2
Input per connection
1/each
Output per connection
1/each
Output blocking voltage, max
35V DC
Sensor input leakage current, max
<2.5 mA
Type of outputs
DC sourcing
Sensor input operating voltage
19.2...26V DC
Concurrent sessions
Web server: 20
Rated output operating voltage (Ue)
19.2...26.4V DC
Disconnect
Motor disconnect
Output operating current (Ie), nom
500 mA per point
Output thermal current (Ithe), max
500 mA per point
Connection type
Quick disconnects
Output state
Normally open (NO)
Rated impulse voltage (Uimp)
Power circuit: 4 kV
Output utilization category
DC-1, DC-13 per IEC
Ethernet ports
2 (embedded switch)
Message support
Unicast or multicast
Input ON-state voltage (pin 4), nom
10...26.4V DC @ 24V DC
IP configuration
Static, DHCP or BOOTP
Input supply voltage
Unswitched power A3/A2
Type of inputs
24V DC current sinking
Concurrent explicit messages, max (CIP Class 3)
Network connections: 6
Input power terminals
Power circuit: L1, L2, L3
Motor power terminals
Power circuit: T1, T2, T3
Application
Power circuit: three-phase
Overload reset level
Power circuit: 1...100% TCU
Ethernet network topologies supported
Star, tree, linear and ring
DeviceLogix I/O response
Input ratings: 2 ms @ 500 Hz
Output load types
Resistive or light inductive
PE (earth ground) terminal
Power circuit: 4 PE terminals
Reset mode
Power circuit: automatic/manual
Input bounce filter (software configurable)
OFF-ON or ON-OFF: 0.5 ms + 64 ms
Ethernet communication rate
10/100 Mbps, half or full-duplex
Class 1 connection API
Network connections: 2...3200 ms
Input connection type
Single keyed M12, quick disconnect
Output connection type
Single keyed M12, quick disconnect
Ethernet cable
Category 5e: shielded or unshielded
Class 3 connection API
Network connections: 100...10000 ms
Security
Web server: login and password configurable
Power supply
Control circuit (external source): NEC class 2
Rated operating voltage, max
Power circuit: 400Y/230...480Y/277 (-15%, +10%)
Device level ring support
Beacon performance, IEEE 1588 transparent clock
Ethernet connector
M12, D code, female, with Ethernet keying, 4 pin
Request packet interval (RPI)
Network connections: 20 ms default (2 ms minimum)
Rated operating voltage
Control circuit (external source): 24V DC (+10%, -20%)
Webpage features
Web server: status, diagnostics and configuration tabs
Output overcurrent protection
1.5 A (the sum of all outputs cannot exceed this value)
E-mail
Web server: support simple mail transfer protocol (SMTP)
Output surge suppression
Integrated diode to help protect against switching loads
EtherNet/IP ODVA – conformance testing
EtherNet/IP interoperability performance - per A9 PF 2.1
Address conflict detection (ACD)
IP v4 address conflict detection for EtherNet/IP devices
Overvoltage protection
Control circuit (external source): reverse-polarity protected
Sensor sourcing input current (pin 1), max
50 mA per point (maximum 300 mA total for sourcing one device)
Packet rate (pps)
500 packets-per-s (2000 µs), Tx, 500 packets-per-s (2000 µs), Rx
Output current (each)
Control circuit (external source): 500 mA @ switched power supply requirements
Input current (each)
Control circuit (external source): 50 mA @ unswitched power supply requirements
Number of inputs (x 50 mA)
Control circuit (external source): user defined @ switched and unswitched power supply requirements
Number of outputs (x 500 mA)
Control circuit (external source): user defined @ switched and unswitched power supply requirements
I/O connections, max (CIP Class 1)
Network connections: supports up to 2 class 1 CIP connections [exclusive owner (data) or listen-only]. One connection per PLC. Listen only connection requires a data connection to be established.
图纸
2D Drawings (DXF/DWG) 下载 (ZIP)
3D STP (STEP) Model 下载 (ZIP)
Dimension Drawings (PDF) 下载 (PDF)
图纸
2D Drawings (DXF/DWG) 下载 (ZIP)
3D STP (STEP) Model 下载 (ZIP)
Dimension Drawings (PDF) 下载 (PDF)
类型 资源 出版
Selection Guide 280-sg002_-en-p 280-SG002
Technical Data 290-td001_-en-p 290-TD001
User Manual 290e-um001_-en-p 290E-UM001
常规 Specifications --
常规 Wiring Diagrams --
常规 Cicuit Protection Device And SCCR Tables --
常规 Product Cutsheet --
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
Australian RCM China CCC
  • Australian RCM
  • China CCC

This product was certified with the above certifications as of 2025-11-06. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

每页项目:
1-1 关于 1
每页项目:
1-1 关于 1
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
技术规格
Width
260 mm
Height
217.83 mm
Depth
166.5 mm
Number of poles
Power circuit: 3
Wire size
Power terminal: (2) #18... AWG (0.8...5.2 mm²) per terminal
Degree of protection (IP)
IP66
Shipping weight, approx
4.6 kg
Power rating
Power terminal: 25A @ 600V AC
Shock
Opsal: 30 G, exceeds IEC 60947-1
Gland plate options
Conduit entry for power and motor (no cable)
Wire strip length
0.35 ±0.01 in (9 ±2 mm)
Vibration
Opsal: 2.5 G @ tested to MIL-STD-810G, exceeds IEC 60947-1
Tightening torque
Power terminal: 10.6 ±2 in-lb (1.2 ±0.2 Nm)
Mechanical life operations
Disconnect: 200000
Disconnect lock out
Maximum of 3/8 in (9.5 mm) diam lock shackle or hasp
Contactor opening delay
8 ms
Contactor closing delay
18 ms
Wire type
Multi-strand copper wire
Disconnect LOTO locks
Up to 2 locks or hasps are supported
Contactor utilization category
AC-1, AC-3, AC-4 per IEC (refer to life load curves)
Altitude
2000 m
Operating temperature
-20 °C
Storage and transportation temperature
-25 °C
Conducted emission
EN 60947-4-1, Class A
Humidity
5...95% (noncondensing)
Surge transient
1 kV (12) L-L, 2 kV (2) L-N (earth)
Radiated emissions
EN 60947-4-1, Class A
Radio frequency electromagnetic field
EN 60947-4-1, 10V/m, 80 MHz...1 GHz, 10V/m, 1.4 GHz...2 GHz
Degree of protection (NEMA)
4
Pollution degree
3
Radio frequency conducted disturbance immunity
10V @ 150kHz...80 MHz
Electrostatic discharge
4 kV contact and 8 kV air
Fast transient
2 kV (power), 2 kV (PE), 1 kV (communications and control)
DHCP timeout
30 s
Web server
HTTP 1.1
Input ON-state current (pin 4)
2.6mA @ 24V DC
Operating dielectric withstand
2000V AC per IEC
Overvoltage category
Power circuit: III
Product type
Full voltage starter
Fuse rating
UL Class fuse (45 A, maximum)
Consume instance (command)
Default of 3 words (instance 150)
Produce instance (status)
Default of 14 words (instance 152)
Insulation voltage (Ui)
Output ratings: rated 2000V AC per IEC
Rated operating current, max
Power circuit: 0.24...3.5A @ 2Hp (1.5 kW)
Rated input operation voltage
24V DC
Input OFF-state current
<1.5 mA
Input OFF-state voltage
5V DC
Operating frequency
Power circuit: 50/60 Hz (±10%)
User options 1
HAND-OFF-AUTO selector keypad
Trip rating
Power circuit: 120% of full load current (FLC) setting
Application in industrial area permitted (SCPD list)
Size per NFPA 70 (NEC) or NFPA 79 for group motor applications
Short circuit coordination
Type 1
Overload type
Power circuit: solid-state I²t
Insulation voltage
Rated 250V AC
Dielectric withstand
Power circuit: 2500V AC per IEC
Concurrent TCP connections
Network connections: maximum of 15 encapsulated messages over both TCP and UDP
RMS symmetrical amperes
5 kA @ 480Y/277 (short circuit current rating)
Power
Control circuit (external source): 6.6 W @ switched and unswitched power supply requirements
Current, nom
Control circuit (external source): 275 mA @ switched and unswitched power supply requirements
Peak inrush
Control circuit (external source): <5 A for 35 ms @ unswitched power supply requirements
Voltage
Control circuit (external source): 19.2...26.4V DC @ unswitched power supply requirements
Trip class
Power circuit: Class 10 (default), 15, 20 with thermal memory retention (see motor overload trip curves)
Current, max
Control circuit (external source): 450 mA @ unswitched power supply requirements
Power, max
Control circuit (external source): 6.6 W + (24V DC x user defined) @ switched and unswitched power supply requirements
Data
Transported over both TCP and UDP
Application in industrial area permitted
Yes
Supporting protocol for EtherNet/IP
Yes
Mains frequency
50/60 Hz
Number of input devices, max
6
Output OFF-state leakage current, max
1 µa
Number of outputs, max
6
Number of configurable digital I/O
6
Input filtering
100 µs
OFF time, min
200 ms
Sockets, max
150
Output supply voltage (switched power)
A1/A2
Input per connection
1/each
Output per connection
1/each
Output blocking voltage, max
35V DC
Sensor input leakage current, max
<2.5 mA
Type of outputs
DC sourcing
Sensor input operating voltage
19.2...26V DC
Concurrent sessions
Web server: 20
Rated output operating voltage (Ue)
19.2...26.4V DC
Disconnect
Motor disconnect
Output operating current (Ie), nom
500 mA per point
Output thermal current (Ithe), max
500 mA per point
Connection type
Quick disconnects
Output state
Normally open (NO)
Rated impulse voltage (Uimp)
Power circuit: 4 kV
Output utilization category
DC-1, DC-13 per IEC
Ethernet ports
2 (embedded switch)
Message support
Unicast or multicast
Input ON-state voltage (pin 4), nom
10...26.4V DC @ 24V DC
IP configuration
Static, DHCP or BOOTP
Input supply voltage
Unswitched power A3/A2
Type of inputs
24V DC current sinking
Concurrent explicit messages, max (CIP Class 3)
Network connections: 6
Input power terminals
Power circuit: L1, L2, L3
Motor power terminals
Power circuit: T1, T2, T3
Application
Power circuit: three-phase
Overload reset level
Power circuit: 1...100% TCU
Ethernet network topologies supported
Star, tree, linear and ring
DeviceLogix I/O response
Input ratings: 2 ms @ 500 Hz
Output load types
Resistive or light inductive
PE (earth ground) terminal
Power circuit: 4 PE terminals
Reset mode
Power circuit: automatic/manual
Input bounce filter (software configurable)
OFF-ON or ON-OFF: 0.5 ms + 64 ms
Ethernet communication rate
10/100 Mbps, half or full-duplex
Class 1 connection API
Network connections: 2...3200 ms
Input connection type
Single keyed M12, quick disconnect
Output connection type
Single keyed M12, quick disconnect
Ethernet cable
Category 5e: shielded or unshielded
Class 3 connection API
Network connections: 100...10000 ms
Security
Web server: login and password configurable
Power supply
Control circuit (external source): NEC class 2
Rated operating voltage, max
Power circuit: 400Y/230...480Y/277 (-15%, +10%)
Device level ring support
Beacon performance, IEEE 1588 transparent clock
Ethernet connector
M12, D code, female, with Ethernet keying, 4 pin
Request packet interval (RPI)
Network connections: 20 ms default (2 ms minimum)
Rated operating voltage
Control circuit (external source): 24V DC (+10%, -20%)
Webpage features
Web server: status, diagnostics and configuration tabs
Output overcurrent protection
1.5 A (the sum of all outputs cannot exceed this value)
E-mail
Web server: support simple mail transfer protocol (SMTP)
Output surge suppression
Integrated diode to help protect against switching loads
EtherNet/IP ODVA – conformance testing
EtherNet/IP interoperability performance - per A9 PF 2.1
Address conflict detection (ACD)
IP v4 address conflict detection for EtherNet/IP devices
Overvoltage protection
Control circuit (external source): reverse-polarity protected
Sensor sourcing input current (pin 1), max
50 mA per point (maximum 300 mA total for sourcing one device)
Packet rate (pps)
500 packets-per-s (2000 µs), Tx, 500 packets-per-s (2000 µs), Rx
Output current (each)
Control circuit (external source): 500 mA @ switched power supply requirements
Input current (each)
Control circuit (external source): 50 mA @ unswitched power supply requirements
Number of inputs (x 50 mA)
Control circuit (external source): user defined @ switched and unswitched power supply requirements
Number of outputs (x 500 mA)
Control circuit (external source): user defined @ switched and unswitched power supply requirements
I/O connections, max (CIP Class 1)
Network connections: supports up to 2 class 1 CIP connections [exclusive owner (data) or listen-only]. One connection per PLC. Listen only connection requires a data connection to be established.
图纸
图纸
2D Drawings (DXF/DWG) 下载 (ZIP)
3D STP (STEP) Model 下载 (ZIP)
Dimension Drawings (PDF) 下载 (PDF)
图纸
2D Drawings (DXF/DWG) 下载 (ZIP)
3D STP (STEP) Model 下载 (ZIP)
Dimension Drawings (PDF) 下载 (PDF)
文档
280-sg002_-en-p Selection Guide
280-SG002
290-td001_-en-p Technical Data
290-TD001
290e-um001_-en-p User Manual
290E-UM001
Specifications 常规
--
Wiring Diagrams 常规
--
Cicuit Protection Device And SCCR Tables 常规
--
Product Cutsheet 常规
--
类型 资源 出版
Selection Guide 280-sg002_-en-p 280-SG002
Technical Data 290-td001_-en-p 290-TD001
User Manual 290e-um001_-en-p 290E-UM001
常规 Specifications --
常规 Wiring Diagrams --
常规 Cicuit Protection Device And SCCR Tables --
常规 Product Cutsheet --
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
认证
Australian RCM China CCC
  • Australian RCM
  • China CCC

This product was certified with the above certifications as of 2025-11-06. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

配件
每页项目:
1-1 关于 1
替代产品
每页项目:
1-1 关于 1
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
Loading
寻找最近经销商
Contact your distributor in {0}
更改位置
EmailEmail
PhonePhone
寻找合作伙伴
Direct Online Starter
CloseClose
290E-FAZ-G1-3
关闭
打印
Chevron LeftChevron Left
Allen-Bradley 290E-FAZ-G1-3 product image
Chevron LeftChevron Left
Allen-Bradley 290E-FAZ-G1-3 product image
Allen-Bradley 290E-FAZ-G1-3 product image
电话:
呼叫
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页
  2. Chevron LeftChevron Left 产品
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose