生命周期状态: 产品成熟期
Product at a glance
Repair Options Available
Product Registration
生命周期状态: 产品成熟期
Product at a glance
Repair Options Available
Product Registration
添加到BoM
  • 注册产品
  • 寻找支持
技术规格
常规
Mechanical
Environmental
Electrical
Construction
图纸
文档
认证
配件
替代产品
技术说明
Option 3
No Selection for
Torque Performance Mode
Sensorless Vect Ctrl and V/Hz
Degree of protection (IP)
IP67
Shock
Opsal: 15 G
Wire strip length
Power and ground terminals: 9 mm (0.35 in)
Vibration
Opsal, 1 G, 0.15 mm (0.006 in) displacement
Tightening torque
Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal)
Disconnect lock out
Recommend 8 mm (5/16 in) lock shackle or hasp. The hasp should not exceed 8 mm (5/16 in) when closed.
Approximate shipping weight
19.1 kg
Altitude
1000 m
Operating temperature
-20 °C
Storage and transportation temperature
-25 °C
Humidity
5...95% on-condensing
Protection against shock
Power circuit: IP2X per IEC
Surge transient
1 kV L-L, 2 kV L-N (earth)
Radiated emissions
Class A, group 1, equivalent to C2 emissions
Conducted radio frequency emissions
Class A
Radio frequency electromagnetic field
10 V/m
Degree of protection (NEMA)
4
Pollution degree
3
Fast transient
2 kV
Electrostatic discharge
4 kV contact and 8 kV air
Communication
EtherNet/IP
Short circuit protection
25 A rated device
DeviceNet input current surge
15 A for 250 µs
DeviceNet input current
364mA @ 11V DC - 4.0 W
Total w/max. sensor inputs (4)
367mA @ 24V DC - 8.0 W
Overvoltage category
Control circuit: III per IEC
Product type
AC Drive
Rated impulse voltage
Power circuit: rated 6 kV
DeviceNet supply voltage rating
Range 11...25V DC @ 24V DC Nominal
Baud rates
125, 250, 500 kbps
Rated input operation voltage
24V DC
Input OFF-state current
<1.5 mA
Rated output operating current, max
Power circuit: 7.6 A @ 3-phase, 5 Hp rating
Input OFF-state voltage
0...5V DC
Input ON-state voltage
10...26V DC
Torque performance mode
Sensorless vector control and volts per Hz
Distance, max
500 m (1630 ft) @ 125 kbps
Operating frequency
Power circuit: 50/60 Hz
Input ON-state current
7.2mA @ 24V DC
Option 1
HAND-OFF-AUTO selector keypad with jog function
Number of contacts
Output rating- sourced from control circuit: 2
Short-circuit protection device list
Size per NEC group motor per UL/NEMA
Input compatibility
IEC 1133 Type 1+
Application in industrial area permitted (SCPD list)
Size per NFPA 70 (NEC) or NFPA 79 for group motor applications
Rated output operation voltage
Sourced from control circuit: 240V AC / 30V DC
Drive input current ratings
12.5A @ 460V, 5 Hp, 3-phase, 60 Hz
Option 2
M25 source brake contactor connector, no cable
Insulation voltage
Power circuit: rated 600V AC
Dielectric withstand
Power circuit: 2500V AC per IEC
Type of contacts
Output rating- sourced from control circuit: normally open (NO)
Outputs current (2) 1 A each, max
External devices powered by control voltage: 2 A @ with brake and output contactor
Current available
Sensor source: 50 mA maximum per input, 200 mA total
Type of control circuit
Output rating- sourced from control circuit: electromechanical relay
Conventional thermal current (Ith)
Output rating- sourced from control circuit: total of both outputs ≤2 A
RMS symmetrical amperes
30 kA @ 600Y/347V per IEC
Rated operation voltage
Power circuit: 380Y/220...480Y/277V AC
3-phase power/motor cable connection
ArmorConnect power media connectivity with no motor cable
Input filter - software selectable
ON to OFF: settable from 0…64 ms in 1 ms increments
Kind of current
Output rating- sourced from control circuit: AC/DC
Nominal control power (pick up)
External devices powered by control voltage: 64 W @ with maximum outputs, with brake and output contactor
Nominal control power (hold in)
External devices powered by control voltage: 64 W @ with maximum outputs, with brake and output contactor
Trip class
Class 10
Number of digital inputs
4
Number of digital outputs
2
Number of analogue inputs
4
Max. output frequency
400 Hz
Supporting protocol for EtherNet/IP
Yes
Mains frequency
50/60 Hz
Number of inputs
4
Enclosure type
IP67/NEMA 4
Disconnect
Motor disconnect
Connection type
Quick disconnects
Utilization category
Power circuit: AC-3 per IEC
External devices powered by DeviceNet
50 mA - total 200 mA
Voltage status
Sensor source: 11...25V DC from DeviceNet
Overload protection
I²t overload protection - 150% @ 60s, 200% @ 30s
Height, approx
287.5 mm @ 460V AC, conduit entrance, 3 Hp and above
Depth, approx
266.9 mm @ 460V AC, conduit entrance, 3 Hp and above
Terminal wire size
Control and safety monitor inputs: 1.0...4.0 mm² per IEC
Wire size
Power and ground terminals: 1.5...4.0 mm² per IEC (primary/sary terminal)
Width, approx
444.38 mm @ 460V AC, conduit entrance, 3 Hp and above
Number of poles
3
图纸
3D STP (STEP) Model 下载 (ZIP)
Product Drawing Drawing (DXF)
图纸
3D STP (STEP) Model 下载 (ZIP)
Product Drawing Drawing (DXF)
类型 资源 出版
User Manual 280e-um001_-en-p 280E-UM001
常规 Circuit Protection Device And SCCR Tables --
常规 External Connections and OL Curves --
常规 Specifications Sheet --
常规 Product Cutsheet --
常规 Repair Parts List --
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
Korean KC UL Listed
  • CE
  • American Bureau of Shippin
  • Korean KC
  • Safety
  • UL Listed

This product was certified with the above certifications as of 2025-07-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

每页项目:
1-1 关于 1
每页项目:
1-1 关于 1
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
技术规格
Option 3
No Selection for
Torque Performance Mode
Sensorless Vect Ctrl and V/Hz
Degree of protection (IP)
IP67
Shock
Opsal: 15 G
Wire strip length
Power and ground terminals: 9 mm (0.35 in)
Vibration
Opsal, 1 G, 0.15 mm (0.006 in) displacement
Tightening torque
Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal)
Disconnect lock out
Recommend 8 mm (5/16 in) lock shackle or hasp. The hasp should not exceed 8 mm (5/16 in) when closed.
Approximate shipping weight
19.1 kg
Altitude
1000 m
Operating temperature
-20 °C
Storage and transportation temperature
-25 °C
Humidity
5...95% on-condensing
Protection against shock
Power circuit: IP2X per IEC
Surge transient
1 kV L-L, 2 kV L-N (earth)
Radiated emissions
Class A, group 1, equivalent to C2 emissions
Conducted radio frequency emissions
Class A
Radio frequency electromagnetic field
10 V/m
Degree of protection (NEMA)
4
Pollution degree
3
Fast transient
2 kV
Electrostatic discharge
4 kV contact and 8 kV air
Communication
EtherNet/IP
Short circuit protection
25 A rated device
DeviceNet input current surge
15 A for 250 µs
DeviceNet input current
364mA @ 11V DC - 4.0 W
Total w/max. sensor inputs (4)
367mA @ 24V DC - 8.0 W
Overvoltage category
Control circuit: III per IEC
Product type
AC Drive
Rated impulse voltage
Power circuit: rated 6 kV
DeviceNet supply voltage rating
Range 11...25V DC @ 24V DC Nominal
Baud rates
125, 250, 500 kbps
Rated input operation voltage
24V DC
Input OFF-state current
<1.5 mA
Rated output operating current, max
Power circuit: 7.6 A @ 3-phase, 5 Hp rating
Input OFF-state voltage
0...5V DC
Input ON-state voltage
10...26V DC
Torque performance mode
Sensorless vector control and volts per Hz
Distance, max
500 m (1630 ft) @ 125 kbps
Operating frequency
Power circuit: 50/60 Hz
Input ON-state current
7.2mA @ 24V DC
Option 1
HAND-OFF-AUTO selector keypad with jog function
Number of contacts
Output rating- sourced from control circuit: 2
Short-circuit protection device list
Size per NEC group motor per UL/NEMA
Input compatibility
IEC 1133 Type 1+
Application in industrial area permitted (SCPD list)
Size per NFPA 70 (NEC) or NFPA 79 for group motor applications
Rated output operation voltage
Sourced from control circuit: 240V AC / 30V DC
Drive input current ratings
12.5A @ 460V, 5 Hp, 3-phase, 60 Hz
Option 2
M25 source brake contactor connector, no cable
Insulation voltage
Power circuit: rated 600V AC
Dielectric withstand
Power circuit: 2500V AC per IEC
Type of contacts
Output rating- sourced from control circuit: normally open (NO)
Outputs current (2) 1 A each, max
External devices powered by control voltage: 2 A @ with brake and output contactor
Current available
Sensor source: 50 mA maximum per input, 200 mA total
Type of control circuit
Output rating- sourced from control circuit: electromechanical relay
Conventional thermal current (Ith)
Output rating- sourced from control circuit: total of both outputs ≤2 A
RMS symmetrical amperes
30 kA @ 600Y/347V per IEC
Rated operation voltage
Power circuit: 380Y/220...480Y/277V AC
3-phase power/motor cable connection
ArmorConnect power media connectivity with no motor cable
Input filter - software selectable
ON to OFF: settable from 0…64 ms in 1 ms increments
Kind of current
Output rating- sourced from control circuit: AC/DC
Nominal control power (pick up)
External devices powered by control voltage: 64 W @ with maximum outputs, with brake and output contactor
Nominal control power (hold in)
External devices powered by control voltage: 64 W @ with maximum outputs, with brake and output contactor
Trip class
Class 10
Number of digital inputs
4
Number of digital outputs
2
Number of analogue inputs
4
Max. output frequency
400 Hz
Supporting protocol for EtherNet/IP
Yes
Mains frequency
50/60 Hz
Number of inputs
4
Enclosure type
IP67/NEMA 4
Disconnect
Motor disconnect
Connection type
Quick disconnects
Utilization category
Power circuit: AC-3 per IEC
External devices powered by DeviceNet
50 mA - total 200 mA
Voltage status
Sensor source: 11...25V DC from DeviceNet
Overload protection
I²t overload protection - 150% @ 60s, 200% @ 30s
Height, approx
287.5 mm @ 460V AC, conduit entrance, 3 Hp and above
Depth, approx
266.9 mm @ 460V AC, conduit entrance, 3 Hp and above
Terminal wire size
Control and safety monitor inputs: 1.0...4.0 mm² per IEC
Wire size
Power and ground terminals: 1.5...4.0 mm² per IEC (primary/sary terminal)
Width, approx
444.38 mm @ 460V AC, conduit entrance, 3 Hp and above
Number of poles
3
图纸
图纸
3D STP (STEP) Model 下载 (ZIP)
Product Drawing Drawing (DXF)
图纸
3D STP (STEP) Model 下载 (ZIP)
Product Drawing Drawing (DXF)
文档
280e-um001_-en-p User Manual
280E-UM001
Circuit Protection Device And SCCR Tables 常规
--
External Connections and OL Curves 常规
--
Specifications Sheet 常规
--
Product Cutsheet 常规
--
Repair Parts List 常规
--
类型 资源 出版
User Manual 280e-um001_-en-p 280E-UM001
常规 Circuit Protection Device And SCCR Tables --
常规 External Connections and OL Curves --
常规 Specifications Sheet --
常规 Product Cutsheet --
常规 Repair Parts List --
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
认证
Korean KC UL Listed
  • CE
  • American Bureau of Shippin
  • Korean KC
  • Safety
  • UL Listed

This product was certified with the above certifications as of 2025-07-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

配件
每页项目:
1-1 关于 1
替代产品
每页项目:
1-1 关于 1
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
Loading
寻找最近经销商
Contact your distributor in {0}
更改位置
EmailEmail
PhonePhone
寻找合作伙伴
EtherNet_IP ArmorStart VFD
CloseClose
284E-FVD7P6Z-25-RRW-3-DB1-SBW
关闭
打印
Chevron LeftChevron Left
Allen-Bradley 284E-FVD7P6Z-25-RRW-3-DB1-SBW product image
Chevron LeftChevron Left
Allen-Bradley 284E-FVD7P6Z-25-RRW-3-DB1-SBW product image
Allen-Bradley 284E-FVD7P6Z-25-RRW-3-DB1-SBW product image
电话:
呼叫
Rockwell Automation Home
Copyright ©2026 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页
  2. Chevron LeftChevron Left 产品
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose