| Degree of protection (IP) |
IP67
|
|---|---|
| Shipping weight, approx |
13.6 kg
|
| Shock |
Opsal: 15 G
|
| Wire strip length |
Power and ground terminals: 0.35 in (9 mm)
|
| Vibration |
Opsal, 1 G, 0.15 mm (0.006 in) displacement
|
| Tightening torque |
Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal)
|
| Disconnect lock out |
Recommend 8 mm (5/16 in) lock shackle or hasp. The hasp should not exceed 8 mm (5/16 in) when closed.
|
| Altitude |
1000 m
|
|---|---|
| Operating temperature |
-20 °C
|
| Storage and transportation temperature |
-25 °C
|
| Humidity |
5...95% (noncondensing)
|
| Protection against shock |
Power circuit: IP2X per IEC
|
| Surge transient |
1 kV (12) L-L, 2 kV (2) L-N (earth)
|
| Radiated emissions |
Class A, Group 1, equivalent to C2 emissions
|
| Conducted radio frequency emissions |
10V rms communications cables, 10V rms (PE), 150 kHz...80 MHz
|
| Radio frequency electromagnetic field |
10V/m, 80 MHz...1 GHz, 3V/m, 1.4 GHz...2 GHz, 1V/m, 2.0 GHz...2.7 GHz
|
| Degree of protection (NEMA) |
4
|
| Pollution degree |
3
|
| Electrostatic discharge |
4 kV contact and 8 kV air
|
| Fast transient |
2 kV (power), 2 kV (PE), 1 kV (communications and control)
|
| Option 3 |
EMI filter
|
|---|---|
| DHCP timeout |
Ethernet port: 30 s
|
| Web server |
Embedded web server
|
| Control module |
Control module only
|
| Overvoltage category |
Control circuit: III per IEC
|
| Rated impulse voltage |
Power circuit: 6 kV
|
| IP address |
Ethernet port: DHCP enabled by default
|
| Ports |
Ethernet port: embedded switch with 2 ports
|
| Faultless power ride through |
Sensorless vector control: 100 ms
|
| Rated input operation voltage |
Sourced from control circuit (A3/A2): 24V DC
|
| Input OFF-state current |
Sourced from control circuit (A3/A2): <1.5 mA
|
| Rated output operating current, max |
Power circuit: 2.3 A @ 3-phase, 1 Hp rating
|
| Input OFF-state voltage |
Sourced from control circuit (A3/A2): 0...5V DC
|
| Module inrush current |
EtherNet/IP version: 1.09 A (A1/A2 with HOA)
|
| Module steady current |
EtherNet/IP version: 0.3 A (A3/A2 without HOA)
|
| Total control power (running) |
EtherNet/IP version: 7.2 W (A3/A2 without HOA)
|
| Hp (KW) rating/input voltage, max |
Sensorless vector control: 5 Hp (3.3 kW)/480V AC
|
| Input ON-state voltage |
Sourced from control circuit (A3/A2): 10...26V DC
|
| Torque performance mode |
Sensorless vector control and volts per Hz
|
| Operating frequency |
Power Circuit: 50/60 Hz
|
| Input ON-state current |
Sourced from control circuit (A3/A2): 7.2mA @ 24V DC
|
| Ethernet receptacles |
Ethernet Port: 2 D-coded, 4-pin female M12 connectors
|
| Option 1 |
HAND-OFF-AUTO selector keypad with jog function
|
| Number of contacts |
Output ratings - sourced from control circuit (A1/A2): 2
|
| Voltage status only |
Sensor source: 11...26.4V DC from unswitched power
|
| Type of current |
Output ratings - sourced from control circuit (A1/A2): 24V DC
|
| Short-circuit protection device list |
Size per NFPA 70 (NEC) or NFPA 79 for group motor applications
|
| Input compatibility |
Sourced from control circuit (A3/A2): IEC 1+ per IEC
|
| ON-state voltage, max |
Output ratings - sourced from control circuit (A1/A2): 1.5V DC
|
| Rated output operation voltage |
Sourced from control circuit (A1/A2): 26.4V DC
|
| Drive output current ratings |
Sensorless vector control: 2.3A @ 460V, 60 Hz, 3-phase, 1 Hp
|
| Drive input current ratings |
Sensorless vector control: 9.00A @ 380V, 50 Hz, 3-phase, 2.2 kW
|
| Option 2 |
Source brake contactor
|
| Insulation voltage |
Power circuit: rated 600V
|
| Frequency accuracy - digital input |
Sensorless vector control: within ±0.05% of set output frequency.
|
| Carrier frequency |
Sensorless vector control: 2...16 kHz. drive rating is based on 4 kHz.
|
| Speed regulation - open loop with slip compensation |
Sensorless vector control: ±1% of base speed across a 60:1 speed range
|
| DB resistance, min |
97 Ω @ drive input voltage of 480V @ 50/60Hz, 2.2 kW, 3 Hp
|
| Communication rate |
Ethernet port: 10/100 Mbs with auto negotiate half duplex and full duplex
|
| Dielectric withstand |
Power circuit: 2500V AC per IEC
|
| Type of contacts |
Output ratings - sourced from control circuit (A1/A2): normally open (N.O.)
|
| Electronic motor overload protection |
Sensorless vector control: Class 10 protection with speed sensitive response
|
| Current available |
Sensor source: 50 mA maximum per input, 200 mA for any single point
|
| Type of control circuit |
Output ratings - sourced from control circuit (A1/A2): solid state sourcing output
|
| Conventional thermal current (Ith) |
Output ratings - sourced from control circuit (A1/A2): 0.5 A each, 1 A max. combined
|
| Circuit breaker operational current rating, max |
60A @ 480V (with gland type: RR)
|
| RMS symmetrical amperes |
65 kA @ 480Y/277V (with gland type: RR)
|
| Total control power |
EtherNet/IP version: 8.4 W with dynamic brake or output contactor option (A3/A2 with HOA)
|
| Rated operation voltage |
Power circuit: 380...480V
|
| 3-phase power/motor cable connection |
Round-ArmorStart ST compatible
|
| Input filter - software selectable |
Sourced from control circuit (A3/A3): settable from 0...64 ms in 1 ms increments (ON to OFF)
|
| Fuse operational current rating, max |
Time delay: 20 A @ 480Y/277V (with gland type: RR)
|
| Total control power (pick up) |
EtherNet/IP version: 7.2 W (A3/A2 without HOA)
|
| Peak output current |
Sourced from control circuit (A1/A2): current limited 2-8 A (5 A nominal) @ 24V DC
|
| Over voltage |
Sensorless vector control: 380...460V AC input - trip occurs @ 810V DC bus voltage (equivalent to 575V AC incoming line)
|
| Under voltage |
Sensorless vector control: 380...480V AC input - trip occurs @ 390V DC bus voltage (equivalent to 275V AC incoming line)
|
| Stop modes |
Sensorless vector control: multiple progmable stop modes including - rA, coast, DC-brake, rA-to-hold and S curve.
|
| Data |
Ethernet port: Transported over both TCP and UDP, Minimum of 500 I/O packets/s (pps), Supports up to 150 concurrent TCP sockets
|
| Input frequency response, max |
Sourced from control circuit (A3/A2): 200 Hz (DeviceLogix response is greater than 200 Hz, network response depends on control system network performance.)
|
| Device connections |
TCP port supports 5 concurrent incoming connections
|
| Application in industrial area permitted |
Yes
|
| Max. output frequency |
400 Hz
|
| Supporting protocol for EtherNet/IP |
Yes
|
| Mains frequency |
50/60 Hz
|
| Short circuit protection device performance (SCPD) type |
Type 1
|
| Drive efficiency |
97.5% typical
|
| Drive output frequency |
0...400 Hz progmable
|
| Utilization category |
Power circuit: AC-3 per IEC
|
| Preset speeds |
Sensorless vector control: 8
|
| Skip frequency |
Sensorless vector control: Yes
|
| StepLogic® functionality |
Sensorless vector control: Yes
|
| Timer/counter functions |
Sensorless vector control: Yes
|
| Security |
Web server: login and password configurable
|
| Internal fan for 284 |
Fan L10 ops data: 80K hr at 40 °C (104 °F)
|
| Configuration |
Web server: status, diagnostics and configuration tabs
|
|
Web server: support simple mail transfer protocol (SMTP)
|
|
| Off-state leakage current, max |
Output ratings - sourced from control circuit (A1/A2): 10 µA
|
| Blocking voltage, max |
Output ratings - sourced from control circuit (A1/A2): 35V DC
|
| Fault recovery |
DLR: ring recovery time is less than 3 ms for a 50 node network
|
| Overcurrent |
Sensorless vector control: 200% hardware limit, 300% instantaneous fault
|
| Device level ring |
Beacon-based performance including IEEE 1588 end to end transparent clock
|
| Load types |
Output ratings - sourced from control circuit (A1/A2): resistive or light inductive
|
| Surge suppression |
Output ratings - sourced from control circuit (A1/A2): integrated diode, clA @ 35V DC
|
| Cycle rate, max |
Output ratings - sourced from control circuit (A1/A2): 30 ops/minute capacitive and inductive loads
|
| Thermo-protection |
Output ratings - sourced from control circuit (A1/A2): integrated short circuit and over current protection
|
| Motor overload protection |
Sensorless vector control: I²t overload protection - 150% @ 60s, 200% @ 3s (provides Class 10 protection)
|
| Accel/decel |
Sensorless vector control: two independently progmable accel and decel times. each time may be progmed from 0...600 s in 0.1 s increments.
|
| Wire size |
Power and ground terminals: #16... AWG per UL/NEMA (primary/sary terminal)
|
|---|
| 基本信息 | 出版 |
|---|---|
| Technical Data | 280ES-TD001 |
| User Manual | 280-UM002 |
| Selection Guide | 280-SG002 |
| Product Profile | 280ES-PC001 |
| Product Cutsheet | -- |
- CE
- Korean KC
截至 2025-07-19,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。
技术规格
| Degree of protection (IP) |
IP67
|
|---|---|
| Shipping weight, approx |
13.6 kg
|
| Shock |
Opsal: 15 G
|
| Wire strip length |
Power and ground terminals: 0.35 in (9 mm)
|
| Vibration |
Opsal, 1 G, 0.15 mm (0.006 in) displacement
|
| Tightening torque |
Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal)
|
| Disconnect lock out |
Recommend 8 mm (5/16 in) lock shackle or hasp. The hasp should not exceed 8 mm (5/16 in) when closed.
|
| Altitude |
1000 m
|
|---|---|
| Operating temperature |
-20 °C
|
| Storage and transportation temperature |
-25 °C
|
| Humidity |
5...95% (noncondensing)
|
| Protection against shock |
Power circuit: IP2X per IEC
|
| Surge transient |
1 kV (12) L-L, 2 kV (2) L-N (earth)
|
| Radiated emissions |
Class A, Group 1, equivalent to C2 emissions
|
| Conducted radio frequency emissions |
10V rms communications cables, 10V rms (PE), 150 kHz...80 MHz
|
| Radio frequency electromagnetic field |
10V/m, 80 MHz...1 GHz, 3V/m, 1.4 GHz...2 GHz, 1V/m, 2.0 GHz...2.7 GHz
|
| Degree of protection (NEMA) |
4
|
| Pollution degree |
3
|
| Electrostatic discharge |
4 kV contact and 8 kV air
|
| Fast transient |
2 kV (power), 2 kV (PE), 1 kV (communications and control)
|
| Option 3 |
EMI filter
|
|---|---|
| DHCP timeout |
Ethernet port: 30 s
|
| Web server |
Embedded web server
|
| Control module |
Control module only
|
| Overvoltage category |
Control circuit: III per IEC
|
| Rated impulse voltage |
Power circuit: 6 kV
|
| IP address |
Ethernet port: DHCP enabled by default
|
| Ports |
Ethernet port: embedded switch with 2 ports
|
| Faultless power ride through |
Sensorless vector control: 100 ms
|
| Rated input operation voltage |
Sourced from control circuit (A3/A2): 24V DC
|
| Input OFF-state current |
Sourced from control circuit (A3/A2): <1.5 mA
|
| Rated output operating current, max |
Power circuit: 2.3 A @ 3-phase, 1 Hp rating
|
| Input OFF-state voltage |
Sourced from control circuit (A3/A2): 0...5V DC
|
| Module inrush current |
EtherNet/IP version: 1.09 A (A1/A2 with HOA)
|
| Module steady current |
EtherNet/IP version: 0.3 A (A3/A2 without HOA)
|
| Total control power (running) |
EtherNet/IP version: 7.2 W (A3/A2 without HOA)
|
| Hp (KW) rating/input voltage, max |
Sensorless vector control: 5 Hp (3.3 kW)/480V AC
|
| Input ON-state voltage |
Sourced from control circuit (A3/A2): 10...26V DC
|
| Torque performance mode |
Sensorless vector control and volts per Hz
|
| Operating frequency |
Power Circuit: 50/60 Hz
|
| Input ON-state current |
Sourced from control circuit (A3/A2): 7.2mA @ 24V DC
|
| Ethernet receptacles |
Ethernet Port: 2 D-coded, 4-pin female M12 connectors
|
| Option 1 |
HAND-OFF-AUTO selector keypad with jog function
|
| Number of contacts |
Output ratings - sourced from control circuit (A1/A2): 2
|
| Voltage status only |
Sensor source: 11...26.4V DC from unswitched power
|
| Type of current |
Output ratings - sourced from control circuit (A1/A2): 24V DC
|
| Short-circuit protection device list |
Size per NFPA 70 (NEC) or NFPA 79 for group motor applications
|
| Input compatibility |
Sourced from control circuit (A3/A2): IEC 1+ per IEC
|
| ON-state voltage, max |
Output ratings - sourced from control circuit (A1/A2): 1.5V DC
|
| Rated output operation voltage |
Sourced from control circuit (A1/A2): 26.4V DC
|
| Drive output current ratings |
Sensorless vector control: 2.3A @ 460V, 60 Hz, 3-phase, 1 Hp
|
| Drive input current ratings |
Sensorless vector control: 9.00A @ 380V, 50 Hz, 3-phase, 2.2 kW
|
| Option 2 |
Source brake contactor
|
| Insulation voltage |
Power circuit: rated 600V
|
| Frequency accuracy - digital input |
Sensorless vector control: within ±0.05% of set output frequency.
|
| Carrier frequency |
Sensorless vector control: 2...16 kHz. drive rating is based on 4 kHz.
|
| Speed regulation - open loop with slip compensation |
Sensorless vector control: ±1% of base speed across a 60:1 speed range
|
| DB resistance, min |
97 Ω @ drive input voltage of 480V @ 50/60Hz, 2.2 kW, 3 Hp
|
| Communication rate |
Ethernet port: 10/100 Mbs with auto negotiate half duplex and full duplex
|
| Dielectric withstand |
Power circuit: 2500V AC per IEC
|
| Type of contacts |
Output ratings - sourced from control circuit (A1/A2): normally open (N.O.)
|
| Electronic motor overload protection |
Sensorless vector control: Class 10 protection with speed sensitive response
|
| Current available |
Sensor source: 50 mA maximum per input, 200 mA for any single point
|
| Type of control circuit |
Output ratings - sourced from control circuit (A1/A2): solid state sourcing output
|
| Conventional thermal current (Ith) |
Output ratings - sourced from control circuit (A1/A2): 0.5 A each, 1 A max. combined
|
| Circuit breaker operational current rating, max |
60A @ 480V (with gland type: RR)
|
| RMS symmetrical amperes |
65 kA @ 480Y/277V (with gland type: RR)
|
| Total control power |
EtherNet/IP version: 8.4 W with dynamic brake or output contactor option (A3/A2 with HOA)
|
| Rated operation voltage |
Power circuit: 380...480V
|
| 3-phase power/motor cable connection |
Round-ArmorStart ST compatible
|
| Input filter - software selectable |
Sourced from control circuit (A3/A3): settable from 0...64 ms in 1 ms increments (ON to OFF)
|
| Fuse operational current rating, max |
Time delay: 20 A @ 480Y/277V (with gland type: RR)
|
| Total control power (pick up) |
EtherNet/IP version: 7.2 W (A3/A2 without HOA)
|
| Peak output current |
Sourced from control circuit (A1/A2): current limited 2-8 A (5 A nominal) @ 24V DC
|
| Over voltage |
Sensorless vector control: 380...460V AC input - trip occurs @ 810V DC bus voltage (equivalent to 575V AC incoming line)
|
| Under voltage |
Sensorless vector control: 380...480V AC input - trip occurs @ 390V DC bus voltage (equivalent to 275V AC incoming line)
|
| Stop modes |
Sensorless vector control: multiple progmable stop modes including - rA, coast, DC-brake, rA-to-hold and S curve.
|
| Data |
Ethernet port: Transported over both TCP and UDP, Minimum of 500 I/O packets/s (pps), Supports up to 150 concurrent TCP sockets
|
| Input frequency response, max |
Sourced from control circuit (A3/A2): 200 Hz (DeviceLogix response is greater than 200 Hz, network response depends on control system network performance.)
|
| Device connections |
TCP port supports 5 concurrent incoming connections
|
| Application in industrial area permitted |
Yes
|
| Max. output frequency |
400 Hz
|
| Supporting protocol for EtherNet/IP |
Yes
|
| Mains frequency |
50/60 Hz
|
| Short circuit protection device performance (SCPD) type |
Type 1
|
| Drive efficiency |
97.5% typical
|
| Drive output frequency |
0...400 Hz progmable
|
| Utilization category |
Power circuit: AC-3 per IEC
|
| Preset speeds |
Sensorless vector control: 8
|
| Skip frequency |
Sensorless vector control: Yes
|
| StepLogic® functionality |
Sensorless vector control: Yes
|
| Timer/counter functions |
Sensorless vector control: Yes
|
| Security |
Web server: login and password configurable
|
| Internal fan for 284 |
Fan L10 ops data: 80K hr at 40 °C (104 °F)
|
| Configuration |
Web server: status, diagnostics and configuration tabs
|
|
Web server: support simple mail transfer protocol (SMTP)
|
|
| Off-state leakage current, max |
Output ratings - sourced from control circuit (A1/A2): 10 µA
|
| Blocking voltage, max |
Output ratings - sourced from control circuit (A1/A2): 35V DC
|
| Fault recovery |
DLR: ring recovery time is less than 3 ms for a 50 node network
|
| Overcurrent |
Sensorless vector control: 200% hardware limit, 300% instantaneous fault
|
| Device level ring |
Beacon-based performance including IEEE 1588 end to end transparent clock
|
| Load types |
Output ratings - sourced from control circuit (A1/A2): resistive or light inductive
|
| Surge suppression |
Output ratings - sourced from control circuit (A1/A2): integrated diode, clA @ 35V DC
|
| Cycle rate, max |
Output ratings - sourced from control circuit (A1/A2): 30 ops/minute capacitive and inductive loads
|
| Thermo-protection |
Output ratings - sourced from control circuit (A1/A2): integrated short circuit and over current protection
|
| Motor overload protection |
Sensorless vector control: I²t overload protection - 150% @ 60s, 200% @ 3s (provides Class 10 protection)
|
| Accel/decel |
Sensorless vector control: two independently progmable accel and decel times. each time may be progmed from 0...600 s in 0.1 s increments.
|
| Wire size |
Power and ground terminals: #16... AWG per UL/NEMA (primary/sary terminal)
|
|---|
图纸
文档
|
Technical Data
基本信息
280ES-TD001 |
|
User Manual
基本信息
280-UM002 |
|
Selection Guide
基本信息
280-SG002 |
|
Product Profile
基本信息
280ES-PC001 |
|
Product Cutsheet
基本信息
-- |
| 基本信息 | 出版 |
|---|---|
| Technical Data | 280ES-TD001 |
| User Manual | 280-UM002 |
| Selection Guide | 280-SG002 |
| Product Profile | 280ES-PC001 |
| Product Cutsheet | -- |
认证
- CE
- Korean KC
截至 2025-07-19,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。
技术说明
Loading
Copyright ©2026 Rockwell Automation, Inc.