Loading
  • alt text
alt text
280D-FN-10-C

ArmorStart Repair Base Mod Starter

PrintPrint
打印
EmailEmail
共享
Product RegistrationProduct Registration
二维码
Allen-Bradley 280D-FN-10-C product image
生命周期状态: 停止
ErrorsErrors
Rockwell Automation announces that as of October 08, 2024, the ArmorStart Repair Base Mod Starter will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期: October 08, 2024 替代类别: No planned RA replacement
产品概览
提供多种维修方式
生命周期状态: 停止
ErrorsErrors
Rockwell Automation announces that as of October 08, 2024, the ArmorStart Repair Base Mod Starter will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期: October 08, 2024 替代类别: No planned RA replacement
产品概览
提供多种维修方式
添加到BoM
  • 寻找支持
技术规格
基本信息
Mechanical
Environmental
Electrical
Construction
文档
认证
替代产品
技术说明
Base Module
Base Module Only
Communications
DeviceNet
Degree of protection (IP)
IP67
Shipping weight, approx
10.4 kg
Shock
Opsal: 15 G
Wire strip length
Power and ground terminals: 0.35 in (9 mm)
Vibration
Opsal, 1 G, 0.15 mm (0.006 in) displacement
Tightening torque
Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal)
Mechanical life operations
Output ratings (sourced from control circuit): 50000000 ops (18K ops/hr)
Disconnect lock out
Recommend 8 mm (5/16 in) lock shackle or hasp. The hasp should not exceed 8 mm (5/16 in) when closed.
Altitude
2000 m
Operating temperature
-20 °C
Humidity
5...95% (noncondensing)
Protection against shock
Power circuit: IP2X per IEC
Surge transient
1 kV L-L, 2 kV L-N (earth)
Radiated emissions
Class A, Group 1, equivalent to C2 emissions
Conducted radio frequency emissions
Class A
Radio frequency electromagnetic field
10 V/m
Degree of protection (NEMA)
4
Pollution degree
3
Fast transient
2 kV
Storage and transportation temperature range
-25 °C
Electrostatic discharge
4 kV contact and 8 kV air
Overload current
3.2 A
Communication
DeviceNet
Short circuit protection
10 A rated device
DeviceNet input current surge
15 A for 250 µs
DeviceNet input current
364mA @ 11V DC - 4.0 W
Total w/max. sensor inputs (4)
367mA @ 24V DC - 8.8 W
Overvoltage category
Control circuit: III per IEC
Rated operational current
Power circuit: 5.5 A maximum
Rated impulse voltage
Power circuit: 6 kV
DeviceNet supply voltage rating
Range 11...25V DC @ 24V DC nominal
Baud rates
125, 250, 500 kbps
Control current (pick up)
Power requirements: 0.71 A without HOA
Control current (hold in)
Power requirements: 0.63 A without HOA
Rated input operation voltage
Sourced from control circuit: 24V DC
Input OFF-state current
<1.5 mA
Input OFF-state voltage
0...5V DC
Input ON-state voltage
10...26V DC
Distance, max
500 m (1630 ft) @ 125 kbps
Operating frequency
Power circuit: 50/60 Hz
Input ON-state current
7.2mA @ 24V DC
Number of contacts
Output rating- sourced from control circuit: 2
Voltage status only
Sensor source: 11...25V DC from DeviceNet
Output current, max
External devices powered by control voltage: 2 A without HOA
Trip rating
120% of full load current (FLC) setting
Input compatibility
IEC 1133 Type 1+ per IEC
Application in industrial area permitted (SCPD list)
Size per NFPA 70 (NEC) or NFPA 79 for group motor applications
Rated output operation voltage
Sourced from control circuit: 240V AC / 30V DC
Insulation voltage
Power circuit: rated 600V
Dielectric withstand
Power circuit: 2500V AC per IEC
Type of contacts
Output rating- sourced from control circuit: normally open (NO)
Current available
Sensor source: 50 mA maximum per input, 200 mA total
Type of control circuit
Output rating- sourced from control circuit: electromechanical relay
Conventional thermal current (Ith)
Output rating- sourced from control circuit: total of both outputs ≤2 A
Circuit breaker operational current rating, max
60A @ 480V (with gland type: CR or DR)
RMS symmetrical amperes
65 kA @ 480Y/277V (with gland type: RR)
Rated operation voltage
Power circuit: 200...575V
3-phase power/motor cable connection
Conduit entrance
Input filter - software selectable
Settable from 0...64 ms in 1 ms increments (ON to OFF)
Kind of current
Output ratings (sourced from control circuit): AC/DC (not to be used as an AC/DC power supply)
Fuse operational current rating, max
Time delay: 20 A @ 480Y/277V (with gland type: RR)
Total control power (pick up)
Power requirements: 84VA with HOA
Total control power (hold in)
Power requirements: 9VA without HOA
Trip class
Class 10, 15, 20
Operational power rating
Full voltage starters - IP67/Type 4/12: 3Hp @ 460V AC, 60 Hz (Current rating 1.1...5.55 A)
Number of digital inputs
4
Number of digital outputs
2
Supporting protocol for DeviceNet
Yes
Application in industrial area permitted
Yes
Max. output frequency
400 Hz
Mains frequency
50/60 Hz
Short circuit protection device performance (SCPD) type
Type 1
Utilization category
Power circuit: AC-3 per IEC
External devices powered by DeviceNet
50 mA - total 200 mA
Electrical life cycle
Output ratings (sourced from control circuit): 100000 ops (1.8K ops/hr)
Wire size
Power and ground terminals: #16... AWG per UL/NEMA (primary/sary terminal)
Number of poles
3
基本信息 出版
Product Cutsheet --
用户手册 出版
280-um004_-en-p 280-UM004
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
UKCA DOC
  • UKCA DOC

截至 2025-09-08,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。

每页项目:
1-1 关于 1
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
技术规格
Base Module
Base Module Only
Communications
DeviceNet
Degree of protection (IP)
IP67
Shipping weight, approx
10.4 kg
Shock
Opsal: 15 G
Wire strip length
Power and ground terminals: 0.35 in (9 mm)
Vibration
Opsal, 1 G, 0.15 mm (0.006 in) displacement
Tightening torque
Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal)
Mechanical life operations
Output ratings (sourced from control circuit): 50000000 ops (18K ops/hr)
Disconnect lock out
Recommend 8 mm (5/16 in) lock shackle or hasp. The hasp should not exceed 8 mm (5/16 in) when closed.
Altitude
2000 m
Operating temperature
-20 °C
Humidity
5...95% (noncondensing)
Protection against shock
Power circuit: IP2X per IEC
Surge transient
1 kV L-L, 2 kV L-N (earth)
Radiated emissions
Class A, Group 1, equivalent to C2 emissions
Conducted radio frequency emissions
Class A
Radio frequency electromagnetic field
10 V/m
Degree of protection (NEMA)
4
Pollution degree
3
Fast transient
2 kV
Storage and transportation temperature range
-25 °C
Electrostatic discharge
4 kV contact and 8 kV air
Overload current
3.2 A
Communication
DeviceNet
Short circuit protection
10 A rated device
DeviceNet input current surge
15 A for 250 µs
DeviceNet input current
364mA @ 11V DC - 4.0 W
Total w/max. sensor inputs (4)
367mA @ 24V DC - 8.8 W
Overvoltage category
Control circuit: III per IEC
Rated operational current
Power circuit: 5.5 A maximum
Rated impulse voltage
Power circuit: 6 kV
DeviceNet supply voltage rating
Range 11...25V DC @ 24V DC nominal
Baud rates
125, 250, 500 kbps
Control current (pick up)
Power requirements: 0.71 A without HOA
Control current (hold in)
Power requirements: 0.63 A without HOA
Rated input operation voltage
Sourced from control circuit: 24V DC
Input OFF-state current
<1.5 mA
Input OFF-state voltage
0...5V DC
Input ON-state voltage
10...26V DC
Distance, max
500 m (1630 ft) @ 125 kbps
Operating frequency
Power circuit: 50/60 Hz
Input ON-state current
7.2mA @ 24V DC
Number of contacts
Output rating- sourced from control circuit: 2
Voltage status only
Sensor source: 11...25V DC from DeviceNet
Output current, max
External devices powered by control voltage: 2 A without HOA
Trip rating
120% of full load current (FLC) setting
Input compatibility
IEC 1133 Type 1+ per IEC
Application in industrial area permitted (SCPD list)
Size per NFPA 70 (NEC) or NFPA 79 for group motor applications
Rated output operation voltage
Sourced from control circuit: 240V AC / 30V DC
Insulation voltage
Power circuit: rated 600V
Dielectric withstand
Power circuit: 2500V AC per IEC
Type of contacts
Output rating- sourced from control circuit: normally open (NO)
Current available
Sensor source: 50 mA maximum per input, 200 mA total
Type of control circuit
Output rating- sourced from control circuit: electromechanical relay
Conventional thermal current (Ith)
Output rating- sourced from control circuit: total of both outputs ≤2 A
Circuit breaker operational current rating, max
60A @ 480V (with gland type: CR or DR)
RMS symmetrical amperes
65 kA @ 480Y/277V (with gland type: RR)
Rated operation voltage
Power circuit: 200...575V
3-phase power/motor cable connection
Conduit entrance
Input filter - software selectable
Settable from 0...64 ms in 1 ms increments (ON to OFF)
Kind of current
Output ratings (sourced from control circuit): AC/DC (not to be used as an AC/DC power supply)
Fuse operational current rating, max
Time delay: 20 A @ 480Y/277V (with gland type: RR)
Total control power (pick up)
Power requirements: 84VA with HOA
Total control power (hold in)
Power requirements: 9VA without HOA
Trip class
Class 10, 15, 20
Operational power rating
Full voltage starters - IP67/Type 4/12: 3Hp @ 460V AC, 60 Hz (Current rating 1.1...5.55 A)
Number of digital inputs
4
Number of digital outputs
2
Supporting protocol for DeviceNet
Yes
Application in industrial area permitted
Yes
Max. output frequency
400 Hz
Mains frequency
50/60 Hz
Short circuit protection device performance (SCPD) type
Type 1
Utilization category
Power circuit: AC-3 per IEC
External devices powered by DeviceNet
50 mA - total 200 mA
Electrical life cycle
Output ratings (sourced from control circuit): 100000 ops (1.8K ops/hr)
Wire size
Power and ground terminals: #16... AWG per UL/NEMA (primary/sary terminal)
Number of poles
3
文档
Product Cutsheet 基本信息
--
280-um004_-en-p 用户手册
280-UM004
基本信息 出版
Product Cutsheet --
用户手册 出版
280-um004_-en-p 280-UM004
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
认证
UKCA DOC
  • UKCA DOC

截至 2025-09-08,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。

替代产品
每页项目:
1-1 关于 1
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
Loading
寻找最近经销商
请联系您在{0}的经销商
更改位置
EmailEmail
PhonePhone
寻找合作伙伴
ArmorStart Repair Base Mod Starter
CloseClose
280D-FN-10-C
关闭
打印
Allen-Bradley 280D-FN-10-C product image
电话:
呼叫
Rockwell Automation Home
Copyright ©2026 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页
  2. Chevron LeftChevron Left 产品
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose