20DC056A0EYNANANK
PowerFlex 700S AC Drive 56 A 30 kW 20D
Rockwell Automation announces that as of June 30, 2023, the PowerFlex 700S AC Drive 56 A 30 kW 20D will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
June 30, 2023
替代类别:
Engineering Replacement
产品概览
Rockwell Automation announces that as of June 30, 2023, the PowerFlex 700S AC Drive 56 A 30 kW 20D will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
June 30, 2023
替代类别:
Engineering Replacement
产品概览
| Brake IGBT |
Brake IGBT Installed
|
|---|---|
| Filter Options |
W/ EMC Filt & ComModeChoke
|
| Internal Communication Module |
No Communication Module
|
| Product Family |
PowerFlex 700S AC Drive
|
| Degree of protection (IP) |
IP20
|
|---|---|
| Shock |
10 G peak for 11 ms duration (±1.0 ms)
|
| PWM frequency |
4 kHz @ 540V DC
|
| Vibration |
0.152 mm (0.006 in.) displacement, 1 G peak, 5.5 Hz
|
| Number of analogue outputs |
2
|
|---|---|
| Mains voltage |
400 V
|
| Integrated breaking resistance |
No
|
| Max. output voltage |
932 V
|
| DC bus overvoltage trip |
810V DC @ 380/400V
|
| DC nominal bus voltage |
540V DC @ 380/400V
|
| Brake IGBT |
Brake IGBT installed
|
| Internal communication module |
No communication module
|
| Fuse current rating |
100A @ 540V DC
|
| Input voltage rating |
400V AC, 3-phase, 50 Hz
|
| Displacement power factor |
0.98 across speed range
|
| Output current, continuous |
56A @ 540V DC
|
| Output current, 1 min |
64A @ 540V DC
|
| Output current, 3 sec |
86A @ 540V DC
|
| Circuit breaker current rating, max |
200A @ 400V AC, 3-phase
|
| Motor circuit protector current rating, max |
100A @ 400V AC, 3-phase
|
| Logic control ride-thru |
0.25 s, drive not running
|
| Brake resistor |
No internal brake resistor
|
| Cable |
20D-DL2-CL3, 20D-DL2-CR3
|
| Input current rating |
61.9A @ 540V DC
|
| Rated power rating |
30 kW @ 540V DC, normal duty
|
| Documentation |
English documentation
|
| Carrier frequency |
Drive rating: 4 kHz, settings: 2, 4, 6, 8, 10 kHz (6 kHz is for V/Hz ops only)
|
| AC input overvoltage trip |
600V AC @ 380/400V (six pulse, 3-phase)
|
| Input power rating |
36.7 kVA @ 400V AC, 3-phase
|
| Electronic motor overload protection |
Class 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL 508C file E59272
|
| Dual element time delay fuse current rating |
70...125A @ 400V AC, 3-phase
|
| Non-time delay fuse current rating |
70...200A @ 400V AC, 3-phase
|
| Heat sink thermistor |
Monitored by microprocessor overtemperature trip
|
| Drive to motor power ratio, max |
The drive to motor rating cannot exceed a 2:1 ratio
|
| Stop modes |
Multiple progmable stop modes including - RA, Coast, and Current Limit
|
| Acceleration/deceleration |
Independently progmable accel and decel times adjustable from 0 to 6553.5 in 0.1 s increments
|
| Number of digital inputs |
6
|
| Number of digital outputs |
2
|
| Number of analogue inputs |
3
|
| Motor voltage, nom |
383V @ 380...400V drive rating, 400V nominal line voltage
|
| Human interface model |
No HIM (no blank plastic inserted)
|
| Additional configuration |
Phase II DriveLogix 5730
|
| Max. output frequency |
400 Hz
|
| Line voltage, nom |
400V @ 380...400V drive rating, 383V nominal motor voltage
|
| Mains frequency |
50 Hz
|
| Internal EMC filtering |
With EMC filter & common mode choke
|
| User available memory base |
1.5 MB (compactflash for non-volatile storage also available)
|
| Watt loss |
708 W @ 400V AC, 30 kW normal duty, 22 kW heavy duty
|
| Feedback option |
Future use
|
| Drive full power range |
383...528V @ 380...400V drive rating, 383V nominal motor voltage
|
| Drive operating range |
325...528V @ 380...400V drive rating, 383V nominal motor voltage
|
| Torque regulation |
Torque regulation - without ftdback: ±5%, 600 rad/sec bandwidth
|
| Battery |
1769-BA 0.59 g lithium
|
| Enclosure type |
IP20/NEMA/UL Type 1
|
| Output current rating |
56 A, 30 kW normal duty, 22 kW heavy duty, frame 3
|
| Control options |
Phase II control, expanded cassette
|
| Drive overcurrent trip |
Software current limit: 105% of motor rated to 200% of drive rated current
|
| Efficiency |
97.5% at rated A, nominal line volts
|
| Speed control |
Speed regulation - without ftdback: 0.1% of base speed across 120:1 speed range, 120:1 operating range, 50 rad/sec bandwidth
|
| Current limit capability |
Independent motoring and regenerative power limits progmable to 800% of rated output current
|
| Selectable motor control |
Field oriented control with and without a ftdback device and permanent magnet motor control
|
| Serial cable |
1761-CBLPM02 to 1761-NET-AIC, 1761-CBLPA00 to 1761-NET-AIC, 1756-CP3 directly to controller,1747-CP3 directly to controller, category 3(2)
|
| Input phases |
Six-pulse, 3-phase input provides full rating for all drives, single-phase ops provides 50% of rated current
|
| Control method |
Induction motor and brushless motor: sine coded PWM with progmable carrier frequency, indirect self organized, field-oriented control, current-regulated, ratings apply to all drives, refer to the PowerFlex 700S Phase ll control reference manual, public
|
| Number of phases output |
3
|
| Number of phases input |
3
|
| Relative symmetric net voltage tolerance |
10 %
|
| Input frequency, max |
400 Hz
|
| Output frequency range |
0 Hz
|
| DC bus undervoltage trip |
Adjustable
|
| Output voltage range |
0 to rated motor voltage
|
| Power ride-thru |
15 ms at full load
|
| S-curve time |
Adjustable 0.5...4.0 s
|
| Short circuit trip |
Phase-to-phase on drive output
|
| Ground fault trip |
Phase-to-ground on drive output
|
| Control logic noise immunity |
Showering arc transients upto 1500V peak
|
| Line transients |
Up to 6000 volts peak per IEEE C62.41-1991
|
| Compact I/O configuration |
Up to (16) modules (8 modules per bank or 4 max on either side of the power supply)
|
| Intermittent overload |
110% overload capability for up to 1 min, 150% overload capability for up to 3 s
|
| Short circuit current, max |
Using recommended fuse or circuit breaker type: maximum short circuit current rating to match specified fuse/circuit breaker capability ≤200000 A
|
| Encoder voltage supply |
5V DC or 12V DC 320 mA/channel, 5V DC minimum high state voltage state of 0.4V DC @ 12V DC minimum high state voltage of 7.0V DC, maximum low state voltage of 0.4V DC
|
| Height, approx |
517.5 mm
|
|---|---|
| Depth, approx |
200 mm
|
| Width, approx |
253.9 mm
|
| Weight, approx |
Drive: 18.55 kg
|
| Sound level |
Frame 3: 61 dB @ 120 CFM fan speed
|
|---|---|
| Altitude |
1000 m (3300 ft.) maximum without derating
|
| Degree of protection (NEMA) |
1
|
| Atmosphere |
Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors, or dust, If the drive is not going to be installed for a period of time, it must be stored in an area where it will not be exposed to a corrosi
|
| Operating temperature |
50 °C @ 540V DC
|
| Storage temperature |
-40 °C
|
| Relative humidity |
5...95% noncondensing
|
| Surrounding air temperature without derating |
NEMA/UL Type 1: 0° to 40° C (32° to 104° F)
|
| 基本信息 | 出版 |
|---|---|
| User Manual | 20D-UM006 |
| PowerFlex 700S with Phase I Control Reference Manual | PFLEX-RM002 |
| PowerFlex 700S AC Drives with Phase II Control Reference Manual | PFLEX-RM003 |
| Product Cutsheet | -- |
| Technical Data | -- |
| Product Profile | -- |
| Drive Logix Manual | -- |
| 安装说明 | 出版 |
|---|---|
| 20d-in024_-en-p | 20D-IN024 |
| 技术数据 | 出版 |
|---|---|
| 20d-td002_-en-p | 20D-TD002 |
| 用户手册 | 出版 |
|---|---|
| 20d-um001_-en-p | 20D-UM001 |
- Eurasion Economic Community
截至 2025-12-07,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。
技术规格
| Brake IGBT |
Brake IGBT Installed
|
|---|---|
| Filter Options |
W/ EMC Filt & ComModeChoke
|
| Internal Communication Module |
No Communication Module
|
| Product Family |
PowerFlex 700S AC Drive
|
| Degree of protection (IP) |
IP20
|
|---|---|
| Shock |
10 G peak for 11 ms duration (±1.0 ms)
|
| PWM frequency |
4 kHz @ 540V DC
|
| Vibration |
0.152 mm (0.006 in.) displacement, 1 G peak, 5.5 Hz
|
| Number of analogue outputs |
2
|
|---|---|
| Mains voltage |
400 V
|
| Integrated breaking resistance |
No
|
| Max. output voltage |
932 V
|
| DC bus overvoltage trip |
810V DC @ 380/400V
|
| DC nominal bus voltage |
540V DC @ 380/400V
|
| Brake IGBT |
Brake IGBT installed
|
| Internal communication module |
No communication module
|
| Fuse current rating |
100A @ 540V DC
|
| Input voltage rating |
400V AC, 3-phase, 50 Hz
|
| Displacement power factor |
0.98 across speed range
|
| Output current, continuous |
56A @ 540V DC
|
| Output current, 1 min |
64A @ 540V DC
|
| Output current, 3 sec |
86A @ 540V DC
|
| Circuit breaker current rating, max |
200A @ 400V AC, 3-phase
|
| Motor circuit protector current rating, max |
100A @ 400V AC, 3-phase
|
| Logic control ride-thru |
0.25 s, drive not running
|
| Brake resistor |
No internal brake resistor
|
| Cable |
20D-DL2-CL3, 20D-DL2-CR3
|
| Input current rating |
61.9A @ 540V DC
|
| Rated power rating |
30 kW @ 540V DC, normal duty
|
| Documentation |
English documentation
|
| Carrier frequency |
Drive rating: 4 kHz, settings: 2, 4, 6, 8, 10 kHz (6 kHz is for V/Hz ops only)
|
| AC input overvoltage trip |
600V AC @ 380/400V (six pulse, 3-phase)
|
| Input power rating |
36.7 kVA @ 400V AC, 3-phase
|
| Electronic motor overload protection |
Class 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL 508C file E59272
|
| Dual element time delay fuse current rating |
70...125A @ 400V AC, 3-phase
|
| Non-time delay fuse current rating |
70...200A @ 400V AC, 3-phase
|
| Heat sink thermistor |
Monitored by microprocessor overtemperature trip
|
| Drive to motor power ratio, max |
The drive to motor rating cannot exceed a 2:1 ratio
|
| Stop modes |
Multiple progmable stop modes including - RA, Coast, and Current Limit
|
| Acceleration/deceleration |
Independently progmable accel and decel times adjustable from 0 to 6553.5 in 0.1 s increments
|
| Number of digital inputs |
6
|
| Number of digital outputs |
2
|
| Number of analogue inputs |
3
|
| Motor voltage, nom |
383V @ 380...400V drive rating, 400V nominal line voltage
|
| Human interface model |
No HIM (no blank plastic inserted)
|
| Additional configuration |
Phase II DriveLogix 5730
|
| Max. output frequency |
400 Hz
|
| Line voltage, nom |
400V @ 380...400V drive rating, 383V nominal motor voltage
|
| Mains frequency |
50 Hz
|
| Internal EMC filtering |
With EMC filter & common mode choke
|
| User available memory base |
1.5 MB (compactflash for non-volatile storage also available)
|
| Watt loss |
708 W @ 400V AC, 30 kW normal duty, 22 kW heavy duty
|
| Feedback option |
Future use
|
| Drive full power range |
383...528V @ 380...400V drive rating, 383V nominal motor voltage
|
| Drive operating range |
325...528V @ 380...400V drive rating, 383V nominal motor voltage
|
| Torque regulation |
Torque regulation - without ftdback: ±5%, 600 rad/sec bandwidth
|
| Battery |
1769-BA 0.59 g lithium
|
| Enclosure type |
IP20/NEMA/UL Type 1
|
| Output current rating |
56 A, 30 kW normal duty, 22 kW heavy duty, frame 3
|
| Control options |
Phase II control, expanded cassette
|
| Drive overcurrent trip |
Software current limit: 105% of motor rated to 200% of drive rated current
|
| Efficiency |
97.5% at rated A, nominal line volts
|
| Speed control |
Speed regulation - without ftdback: 0.1% of base speed across 120:1 speed range, 120:1 operating range, 50 rad/sec bandwidth
|
| Current limit capability |
Independent motoring and regenerative power limits progmable to 800% of rated output current
|
| Selectable motor control |
Field oriented control with and without a ftdback device and permanent magnet motor control
|
| Serial cable |
1761-CBLPM02 to 1761-NET-AIC, 1761-CBLPA00 to 1761-NET-AIC, 1756-CP3 directly to controller,1747-CP3 directly to controller, category 3(2)
|
| Input phases |
Six-pulse, 3-phase input provides full rating for all drives, single-phase ops provides 50% of rated current
|
| Control method |
Induction motor and brushless motor: sine coded PWM with progmable carrier frequency, indirect self organized, field-oriented control, current-regulated, ratings apply to all drives, refer to the PowerFlex 700S Phase ll control reference manual, public
|
| Number of phases output |
3
|
| Number of phases input |
3
|
| Relative symmetric net voltage tolerance |
10 %
|
| Input frequency, max |
400 Hz
|
| Output frequency range |
0 Hz
|
| DC bus undervoltage trip |
Adjustable
|
| Output voltage range |
0 to rated motor voltage
|
| Power ride-thru |
15 ms at full load
|
| S-curve time |
Adjustable 0.5...4.0 s
|
| Short circuit trip |
Phase-to-phase on drive output
|
| Ground fault trip |
Phase-to-ground on drive output
|
| Control logic noise immunity |
Showering arc transients upto 1500V peak
|
| Line transients |
Up to 6000 volts peak per IEEE C62.41-1991
|
| Compact I/O configuration |
Up to (16) modules (8 modules per bank or 4 max on either side of the power supply)
|
| Intermittent overload |
110% overload capability for up to 1 min, 150% overload capability for up to 3 s
|
| Short circuit current, max |
Using recommended fuse or circuit breaker type: maximum short circuit current rating to match specified fuse/circuit breaker capability ≤200000 A
|
| Encoder voltage supply |
5V DC or 12V DC 320 mA/channel, 5V DC minimum high state voltage state of 0.4V DC @ 12V DC minimum high state voltage of 7.0V DC, maximum low state voltage of 0.4V DC
|
| Height, approx |
517.5 mm
|
|---|---|
| Depth, approx |
200 mm
|
| Width, approx |
253.9 mm
|
| Weight, approx |
Drive: 18.55 kg
|
| Sound level |
Frame 3: 61 dB @ 120 CFM fan speed
|
|---|---|
| Altitude |
1000 m (3300 ft.) maximum without derating
|
| Degree of protection (NEMA) |
1
|
| Atmosphere |
Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors, or dust, If the drive is not going to be installed for a period of time, it must be stored in an area where it will not be exposed to a corrosi
|
| Operating temperature |
50 °C @ 540V DC
|
| Storage temperature |
-40 °C
|
| Relative humidity |
5...95% noncondensing
|
| Surrounding air temperature without derating |
NEMA/UL Type 1: 0° to 40° C (32° to 104° F)
|
文档
|
User Manual
基本信息
20D-UM006 |
|
PowerFlex 700S with Phase I Control Reference Manual
基本信息
PFLEX-RM002 |
|
PowerFlex 700S AC Drives with Phase II Control Reference Manual
基本信息
PFLEX-RM003 |
|
Product Cutsheet
基本信息
-- |
|
Technical Data
基本信息
-- |
|
Product Profile
基本信息
-- |
|
Drive Logix Manual
基本信息
-- |
|
20d-in024_-en-p
安装说明
20D-IN024 |
|
20d-td002_-en-p
技术数据
20D-TD002 |
|
20d-um001_-en-p
用户手册
20D-UM001 |
| 基本信息 | 出版 |
|---|---|
| User Manual | 20D-UM006 |
| PowerFlex 700S with Phase I Control Reference Manual | PFLEX-RM002 |
| PowerFlex 700S AC Drives with Phase II Control Reference Manual | PFLEX-RM003 |
| Product Cutsheet | -- |
| Technical Data | -- |
| Product Profile | -- |
| Drive Logix Manual | -- |
| 安装说明 | 出版 |
| 20d-in024_-en-p | 20D-IN024 |
| 技术数据 | 出版 |
| 20d-td002_-en-p | 20D-TD002 |
| 用户手册 | 出版 |
| 20d-um001_-en-p | 20D-UM001 |