20DC015A0EYNANANK
PowerFlex 700S AC Drive 20D
Rockwell Automation announces that as of June 30, 2023, the PowerFlex 700S AC Drive 20D will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
June 30, 2023
替代类别:
Engineering Replacement
Product at a glance
Rockwell Automation announces that as of June 30, 2023, the PowerFlex 700S AC Drive 20D will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
June 30, 2023
替代类别:
Engineering Replacement
Product at a glance
| Brake IGBT |
Brake IGBT Installed
|
|---|---|
| Feedback Options |
Future Use
|
| Filter Options |
W/ EMC Filt & ComModeChoke
|
| Product Family |
PowerFlex 700S AC Drive
|
| Degree of protection (IP) |
IP20
|
|---|---|
| Shock |
10 G peak for 11 ms duration (±1.0 ms)
|
| PWM frequency |
4 kHz @ 540V DC
|
| Vibration |
0.152 mm (0.006 in.) displacement, 1 G peak, 5.5 Hz
|
| Number of analogue outputs |
2
|
|---|---|
| Mains voltage |
400 V
|
| Integrated breaking resistance |
No
|
| Max. output voltage |
932 V
|
| Internal dynamic brake resistors |
115 ohm
|
| DC bus overvoltage trip |
810V DC @ 380/400V
|
| DC nominal bus voltage |
540V DC @ 380/400V
|
| Brake IGBT |
Brake IGBT installed
|
| Internal communication module |
No communication module
|
| Fuse current rating |
25A @ 540V DC
|
| Input voltage rating |
400V AC, 3-phase, 50 Hz
|
| Displacement power factor |
0.98 across speed range
|
| Output current, continuous |
15.4A @ 540V DC
|
| Output current, 1 min |
17.2A @ 540V DC
|
| Output current, 3 sec |
23.1A @ 540V DC
|
| Circuit breaker current rating, max |
60A @ 400V AC, 3-phase
|
| Motor circuit protector current rating, max |
20A @ 400V AC, 3-phase
|
| Logic control ride-thru |
0.25 s, drive not running
|
| Brake resistor |
No internal brake resistor
|
| Cable |
20D-DL2-CL3, 20D-DL2-CR3
|
| Input current rating |
16.8A @ 540V DC
|
| Rated power rating |
7.5 kW @ 540V DC, normal duty
|
| Documentation |
English documentation
|
| Carrier frequency |
Drive rating: 4 kHz, settings: 2, 4, 6, 8, 10 kHz (6 kHz is for V/Hz ops only)
|
| AC input overvoltage trip |
600V AC @ 380/400V (six pulse, 3-phase)
|
| Input power rating |
10.0 kVA @ 400V AC, 3-phase
|
| Electronic motor overload protection |
Class 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL 508C file E59272
|
| Dual element time delay fuse current rating |
20...30A @ 400V AC, 3-phase
|
| Non-time delay fuse current rating |
20...60A @ 400V AC, 3-phase
|
| Heat sink thermistor |
Monitored by microprocessor overtemperature trip
|
| Drive to motor power ratio, max |
The drive to motor rating cannot exceed a 2:1 ratio
|
| Stop modes |
Multiple progmable stop modes including - RA, Coast, and Current Limit
|
| Acceleration/deceleration |
Independently progmable accel and decel times adjustable from 0 to 6553.5 in 0.1 s increments
|
| Number of digital inputs |
6
|
| Number of digital outputs |
2
|
| Number of analogue inputs |
3
|
| Motor voltage, nom |
383V @ 380...400V drive rating, 400V nominal line voltage
|
| Human interface model |
No HIM (no blank plastic inserted)
|
| Additional configuration |
Phase II DriveLogix 5730
|
| Max. output frequency |
400 Hz
|
| Line voltage, nom |
400V @ 380...400V drive rating, 383V nominal motor voltage
|
| Mains frequency |
50 Hz
|
| Internal EMC filtering |
With EMC filter & common mode choke
|
| User available memory base |
1.5 MB (compactflash for non-volatile storage also available)
|
| Watt loss |
271 W @ 400V AC, 7.5 kW normal duty, 5.5 kW heavy duty
|
| Feedback option |
Future use
|
| Drive full power range |
383...528V @ 380...400V drive rating, 383V nominal motor voltage
|
| Drive operating range |
325...528V @ 380...400V drive rating, 383V nominal motor voltage
|
| Torque regulation |
Torque regulation - without ftdback: ±5%, 600 rad/sec bandwidth
|
| Battery |
1769-BA 0.59 g lithium
|
| Enclosure type |
IP20/NEMA/UL Type 1
|
| Output current rating |
15.4 A, 7.5 kW normal duty, 5.5 kW heavy duty, frame 1
|
| Control options |
Phase II control, expanded cassette
|
| Drive overcurrent trip |
Software current limit: 105% of motor rated to 200% of drive rated current
|
| Efficiency |
97.5% at rated A, nominal line volts
|
| Speed control |
Speed regulation - without ftdback: 0.1% of base speed across 120:1 speed range, 120:1 operating range, 50 rad/sec bandwidth
|
| Current limit capability |
Independent motoring and regenerative power limits progmable to 800% of rated output current
|
| Selectable motor control |
Field oriented control with and without a ftdback device and permanent magnet motor control
|
| Serial cable |
1761-CBLPM02 to 1761-NET-AIC, 1761-CBLPA00 to 1761-NET-AIC, 1756-CP3 directly to controller,1747-CP3 directly to controller, category 3(2)
|
| Input phases |
Six-pulse, 3-phase input provides full rating for all drives, single-phase ops provides 50% of rated current
|
| Control method |
Induction motor and brushless motor: sine coded PWM with progmable carrier frequency, indirect self organized, field-oriented control, current-regulated, ratings apply to all drives, refer to the PowerFlex 700S Phase ll control reference manual, public
|
| Number of phases output |
3
|
| Number of phases input |
3
|
| Relative symmetric net voltage tolerance |
10 %
|
| Input frequency, max |
400 Hz
|
| Output frequency range |
0 Hz
|
| DC bus undervoltage trip |
Adjustable
|
| Output voltage range |
0 to rated motor voltage
|
| Power ride-thru |
15 ms at full load
|
| S-curve time |
Adjustable 0.5...4.0 s
|
| Short circuit trip |
Phase-to-phase on drive output
|
| Ground fault trip |
Phase-to-ground on drive output
|
| Control logic noise immunity |
Showering arc transients upto 1500V peak
|
| Line transients |
Up to 6000 volts peak per IEEE C62.41-1991
|
| Compact I/O configuration |
Up to (16) modules (8 modules per bank or 4 max on either side of the power supply)
|
| Intermittent overload |
110% overload capability for up to 1 min, 150% overload capability for up to 3 s
|
| Short circuit current, max |
Using recommended fuse or circuit breaker type: maximum short circuit current rating to match specified fuse/circuit breaker capability ≤200000 A
|
| Encoder voltage supply |
5V DC or 12V DC 320 mA/channel, 5V DC minimum high state voltage state of 0.4V DC @ 12V DC minimum high state voltage of 7.0V DC, maximum low state voltage of 0.4V DC
|
| Height, approx |
336 mm
|
|---|---|
| Depth, approx |
200 mm
|
| Width, approx |
166.9 mm
|
| Weight, approx |
Drive: 7.03 kg
|
| Sound level |
Frame 1: 59 dB @ 30 CFM fan speed
|
|---|---|
| Altitude |
1000 m (3300 ft.) maximum without derating
|
| Degree of protection (NEMA) |
1
|
| Atmosphere |
Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors, or dust, If the drive is not going to be installed for a period of time, it must be stored in an area where it will not be exposed to a corrosi
|
| Operating temperature |
50 °C @ 540V DC
|
| Storage temperature |
-40 °C
|
| Relative humidity |
5...95% noncondensing
|
| Surrounding air temperature without derating |
NEMA/UL Type 1: 0° to 40° C (32° to 104° F)
|
| 图纸 | |
|---|---|
| Dimension Drawing | 下载 (PDF) |
| Product Drawing | Drawing (DXF) |
| 图纸 |
|---|
| Dimension Drawing 下载 (PDF) |
| Product Drawing Drawing (DXF) |
| 类型 | 资源 | 出版 |
|---|---|---|
| Installation Instructions | 20d-in024_-en-p | 20D-IN024 |
| Technical Data | 20d-td002_-en-p | 20D-TD002 |
| User Manual | 20d-um001_-en-p | 20D-UM001 |
| 常规 | Product Cutsheet | -- |
| 常规 | PowerFlex 700S with Phase I Control Reference Manual | PFLEX-RM002 |
| 常规 | PowerFlex 700S AC Drives with Phase II Control Reference Manual | PFLEX-RM003 |
| 常规 | Technical Data | -- |
| 常规 | Product Profile | -- |
| 常规 | User Manual | 20D-UM006 |
| 常规 | Drive Logix Manual | -- |
- Eurasion Economic Community
This product was certified with the above certifications as of 2025-12-07. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
技术规格
| Brake IGBT |
Brake IGBT Installed
|
|---|---|
| Feedback Options |
Future Use
|
| Filter Options |
W/ EMC Filt & ComModeChoke
|
| Product Family |
PowerFlex 700S AC Drive
|
| Degree of protection (IP) |
IP20
|
|---|---|
| Shock |
10 G peak for 11 ms duration (±1.0 ms)
|
| PWM frequency |
4 kHz @ 540V DC
|
| Vibration |
0.152 mm (0.006 in.) displacement, 1 G peak, 5.5 Hz
|
| Number of analogue outputs |
2
|
|---|---|
| Mains voltage |
400 V
|
| Integrated breaking resistance |
No
|
| Max. output voltage |
932 V
|
| Internal dynamic brake resistors |
115 ohm
|
| DC bus overvoltage trip |
810V DC @ 380/400V
|
| DC nominal bus voltage |
540V DC @ 380/400V
|
| Brake IGBT |
Brake IGBT installed
|
| Internal communication module |
No communication module
|
| Fuse current rating |
25A @ 540V DC
|
| Input voltage rating |
400V AC, 3-phase, 50 Hz
|
| Displacement power factor |
0.98 across speed range
|
| Output current, continuous |
15.4A @ 540V DC
|
| Output current, 1 min |
17.2A @ 540V DC
|
| Output current, 3 sec |
23.1A @ 540V DC
|
| Circuit breaker current rating, max |
60A @ 400V AC, 3-phase
|
| Motor circuit protector current rating, max |
20A @ 400V AC, 3-phase
|
| Logic control ride-thru |
0.25 s, drive not running
|
| Brake resistor |
No internal brake resistor
|
| Cable |
20D-DL2-CL3, 20D-DL2-CR3
|
| Input current rating |
16.8A @ 540V DC
|
| Rated power rating |
7.5 kW @ 540V DC, normal duty
|
| Documentation |
English documentation
|
| Carrier frequency |
Drive rating: 4 kHz, settings: 2, 4, 6, 8, 10 kHz (6 kHz is for V/Hz ops only)
|
| AC input overvoltage trip |
600V AC @ 380/400V (six pulse, 3-phase)
|
| Input power rating |
10.0 kVA @ 400V AC, 3-phase
|
| Electronic motor overload protection |
Class 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL 508C file E59272
|
| Dual element time delay fuse current rating |
20...30A @ 400V AC, 3-phase
|
| Non-time delay fuse current rating |
20...60A @ 400V AC, 3-phase
|
| Heat sink thermistor |
Monitored by microprocessor overtemperature trip
|
| Drive to motor power ratio, max |
The drive to motor rating cannot exceed a 2:1 ratio
|
| Stop modes |
Multiple progmable stop modes including - RA, Coast, and Current Limit
|
| Acceleration/deceleration |
Independently progmable accel and decel times adjustable from 0 to 6553.5 in 0.1 s increments
|
| Number of digital inputs |
6
|
| Number of digital outputs |
2
|
| Number of analogue inputs |
3
|
| Motor voltage, nom |
383V @ 380...400V drive rating, 400V nominal line voltage
|
| Human interface model |
No HIM (no blank plastic inserted)
|
| Additional configuration |
Phase II DriveLogix 5730
|
| Max. output frequency |
400 Hz
|
| Line voltage, nom |
400V @ 380...400V drive rating, 383V nominal motor voltage
|
| Mains frequency |
50 Hz
|
| Internal EMC filtering |
With EMC filter & common mode choke
|
| User available memory base |
1.5 MB (compactflash for non-volatile storage also available)
|
| Watt loss |
271 W @ 400V AC, 7.5 kW normal duty, 5.5 kW heavy duty
|
| Feedback option |
Future use
|
| Drive full power range |
383...528V @ 380...400V drive rating, 383V nominal motor voltage
|
| Drive operating range |
325...528V @ 380...400V drive rating, 383V nominal motor voltage
|
| Torque regulation |
Torque regulation - without ftdback: ±5%, 600 rad/sec bandwidth
|
| Battery |
1769-BA 0.59 g lithium
|
| Enclosure type |
IP20/NEMA/UL Type 1
|
| Output current rating |
15.4 A, 7.5 kW normal duty, 5.5 kW heavy duty, frame 1
|
| Control options |
Phase II control, expanded cassette
|
| Drive overcurrent trip |
Software current limit: 105% of motor rated to 200% of drive rated current
|
| Efficiency |
97.5% at rated A, nominal line volts
|
| Speed control |
Speed regulation - without ftdback: 0.1% of base speed across 120:1 speed range, 120:1 operating range, 50 rad/sec bandwidth
|
| Current limit capability |
Independent motoring and regenerative power limits progmable to 800% of rated output current
|
| Selectable motor control |
Field oriented control with and without a ftdback device and permanent magnet motor control
|
| Serial cable |
1761-CBLPM02 to 1761-NET-AIC, 1761-CBLPA00 to 1761-NET-AIC, 1756-CP3 directly to controller,1747-CP3 directly to controller, category 3(2)
|
| Input phases |
Six-pulse, 3-phase input provides full rating for all drives, single-phase ops provides 50% of rated current
|
| Control method |
Induction motor and brushless motor: sine coded PWM with progmable carrier frequency, indirect self organized, field-oriented control, current-regulated, ratings apply to all drives, refer to the PowerFlex 700S Phase ll control reference manual, public
|
| Number of phases output |
3
|
| Number of phases input |
3
|
| Relative symmetric net voltage tolerance |
10 %
|
| Input frequency, max |
400 Hz
|
| Output frequency range |
0 Hz
|
| DC bus undervoltage trip |
Adjustable
|
| Output voltage range |
0 to rated motor voltage
|
| Power ride-thru |
15 ms at full load
|
| S-curve time |
Adjustable 0.5...4.0 s
|
| Short circuit trip |
Phase-to-phase on drive output
|
| Ground fault trip |
Phase-to-ground on drive output
|
| Control logic noise immunity |
Showering arc transients upto 1500V peak
|
| Line transients |
Up to 6000 volts peak per IEEE C62.41-1991
|
| Compact I/O configuration |
Up to (16) modules (8 modules per bank or 4 max on either side of the power supply)
|
| Intermittent overload |
110% overload capability for up to 1 min, 150% overload capability for up to 3 s
|
| Short circuit current, max |
Using recommended fuse or circuit breaker type: maximum short circuit current rating to match specified fuse/circuit breaker capability ≤200000 A
|
| Encoder voltage supply |
5V DC or 12V DC 320 mA/channel, 5V DC minimum high state voltage state of 0.4V DC @ 12V DC minimum high state voltage of 7.0V DC, maximum low state voltage of 0.4V DC
|
| Height, approx |
336 mm
|
|---|---|
| Depth, approx |
200 mm
|
| Width, approx |
166.9 mm
|
| Weight, approx |
Drive: 7.03 kg
|
| Sound level |
Frame 1: 59 dB @ 30 CFM fan speed
|
|---|---|
| Altitude |
1000 m (3300 ft.) maximum without derating
|
| Degree of protection (NEMA) |
1
|
| Atmosphere |
Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors, or dust, If the drive is not going to be installed for a period of time, it must be stored in an area where it will not be exposed to a corrosi
|
| Operating temperature |
50 °C @ 540V DC
|
| Storage temperature |
-40 °C
|
| Relative humidity |
5...95% noncondensing
|
| Surrounding air temperature without derating |
NEMA/UL Type 1: 0° to 40° C (32° to 104° F)
|
图纸
| 图纸 | |
|---|---|
| Dimension Drawing | 下载 (PDF) |
| Product Drawing | Drawing (DXF) |
| 图纸 |
|---|
| Dimension Drawing 下载 (PDF) |
| Product Drawing Drawing (DXF) |
文档
|
20d-in024_-en-p
Installation Instructions
20D-IN024 |
|
20d-td002_-en-p
Technical Data
20D-TD002 |
|
20d-um001_-en-p
User Manual
20D-UM001 |
|
Product Cutsheet
常规
-- |
|
PowerFlex 700S with Phase I Control Reference Manual
常规
PFLEX-RM002 |
|
PowerFlex 700S AC Drives with Phase II Control Reference Manual
常规
PFLEX-RM003 |
|
Technical Data
常规
-- |
|
Product Profile
常规
-- |
|
User Manual
常规
20D-UM006 |
|
Drive Logix Manual
常规
-- |
| 类型 | 资源 | 出版 |
|---|---|---|
| Installation Instructions | 20d-in024_-en-p | 20D-IN024 |
| Technical Data | 20d-td002_-en-p | 20D-TD002 |
| User Manual | 20d-um001_-en-p | 20D-UM001 |
| 常规 | Product Cutsheet | -- |
| 常规 | PowerFlex 700S with Phase I Control Reference Manual | PFLEX-RM002 |
| 常规 | PowerFlex 700S AC Drives with Phase II Control Reference Manual | PFLEX-RM003 |
| 常规 | Technical Data | -- |
| 常规 | Product Profile | -- |
| 常规 | User Manual | 20D-UM006 |
| 常规 | Drive Logix Manual | -- |
认证
- Eurasion Economic Community
This product was certified with the above certifications as of 2025-12-07. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
配件
替代产品
技术说明
Loading
Copyright ©2025 Rockwell Automation, Inc.