20AC030F0AYNANC0

PowerFlex 70 AC Drive 30 A at 15 kW 20A

PrintPrint
打印
EmailEmail
共享
Product RegistrationProduct Registration
QR code
Allen-Bradley 20AC030F0AYNANC0 product image
Allen-Bradley 20AC030F0AYNANC0 product image
Allen-Bradley 20AC030F0AYNANC0 product image
生命周期状态: 产品停产
ErrorsErrors
Rockwell Automation announces that as of May 30, 2027, the PowerFlex 70 AC Drive 30 A at 15 kW 20A will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期: May 30, 2027 替代类别: Engineering Replacement
Product at a glance
Repair Options Available
生命周期状态: 产品停产
ErrorsErrors
Rockwell Automation announces that as of May 30, 2027, the PowerFlex 70 AC Drive 30 A at 15 kW 20A will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期: May 30, 2027 替代类别: Engineering Replacement
Product at a glance
Repair Options Available
添加到BoM
  • 寻找支持
技术规格
常规
Mechanical
Electrical
Construction
Environmental
图纸
文档
认证
配件
替代产品
技术说明
Brake IGBT
Brake IGBT Installed
Brake Resistor
No Internal
Control And I/O
Enhanced Control with 24V I/O
Feedback Options
No ftdback
Filter Options
W/ EMC Filt & ComModeChoke
Internal Communication Module
No Communication Module
Sub Brand
PowerFlex 70 AC Drive
Degree of protection (IP)
IP66
Shock
15 G peak for 11 ms duration (±1.0 ms)
Vibration
0.152 mm (0.006 in) displacement, 1 G peak
Number of analogue outputs
1
Mains voltage
400 V
Integrated breaking resistance
No
Internal dynamic brake resistors
62 ohm
Brake IGBT
Brake IGBT installed
Bus undervoltage output shutoff
305V DC @ 380/400V
Bus undervoltage fault level
300V DC @ 380/400V
Internal communication module
No communication module
AC input undervoltage trip
233V AC @ 380/400V
Bus voltage, nom
540V DC @ 380/400V
Bus overvoltage trip
810V DC @ 380/400V
Circuit breaker current rating, max
120A @ 400V AC, 3-phase
Motor circuit protector current rating, max
50A @ 400V AC, 3-phase
Output current rating, continuous
30A @ 400V AC, 3-phase
Output current rating, 1 min
33A @ 400V AC, 3-phase
Output current rating, 3 sec
45A @ 400V AC, 3-phase
Logic control ride-thru
0.5 s minimum, 2 s typical
Brake resistor
Without drive mounted brake resistor
Input current rating
30.3A @ 400V AC, 3-phase
Documentation
Manual
Carrier frequency
Standard control: 2, 3, 4, 5, 6, 7, 8, 9, and 10 kHz, vector control: 2, 4, 8, and 12 kHz, drive rating based on 4 kHz
Encoder quadrature
90° ±27°
AC input overvoltage trip
475V AC @ 380/400V
Input power rating
21 kVA @ 400V AC, 3-phase
Dual element time delay fuse current rating
40...60A @ 400V AC, 3-phase
Non-time delay fuse current rating
40...120A @ 400V AC, 3-phase
Heat sink thermistor
Monitored by microprocessor overtemp trip
Drive to motor power ratio, max
Recommended not greater than 2:1 ratio
Stop modes
Multiple progmable stop modes including - RA, Coast, DC-brake, Fast brake, RA-to-hold and S-curve
Acceleration/deceleration
Two independently progmable accel and decel times. Each time can be progmed from 0...3600 s in 0.1 s increments
Frequency accuracy
Digital input: within ±0.01% of set output frequency
Number of digital inputs
6
Number of digital outputs
2
Internal watts loss
42.9 W @ 400V @ 15Hp normal duty
Number of analogue inputs
2
Motor voltage, nom
460V @ 380...480V drive rating, 480V nominal line voltage
Human interface model
No HIM-blank plate
Supporting protocol for DeviceNet
Yes
Application in industrial area permitted
Yes
External watts loss
432.9 W @ 400V @ 15Hp normal duty
Total watts loss
475.8 W @ 400V @ 15Hp normal duty
Line voltage, nom
480V @ 380...480V drive rating, 460V nominal motor voltage
Supporting protocol for EtherNet/IP
Yes
Mains frequency
50 Hz
Output frequency range
Standard control: 0...400 Hz, enhanced control: 0...500 Hz
Internal EMC filtering
S environment filter per CE EMC directive (89/336/EEC)
Feedback option
No ftdback
Drive full power range
460...528V @ 380...480V drive rating, 460V nominal motor voltage
Drive operating range
342...528V @ 380...480V drive rating, 460V nominal motor voltage
Torque regulation
Without ftdback +/-10%, with ftdback +/-5%
Enclosure type
Flanged Mount - Front IP20, NEMA Type 1, Rear = NEMA Type 4X/12 (Indoor /Outdoor)
Output current rating
30 A, 15 kW normal duty, 11 kW heavy duty, frame D
Cooling fan operation
Frames B, D, and E: fan operates when power is applied and in run condition
Control options
Enhanced control with 24V I/O
Drive overcurrent trip
Software current limit: 20...160% of rated current
Efficiency
97.5% at rated A, nominal line volts
Encoder supply
5V/12V configurable ±5%
Speed control-speed regulation
Without ftdback (Vector Control mode): 0.1% of base speed across 120:1 speed range, 120:1 operating range, 30 rad/sec bandwidth
Current limit capability
Proactive current limit progmable from 20...160% of rated output current, Independently progmable proportional and integral gain
Selectable motor control
Sensorless vector with full tuning. Standards V/Hz with full custom capability and vector control
Frequency control-speed regulation
With slip compensation (Volts per Hz mode): 0.5% of base speed across 40:1 speed range, 40:1 operating range, 10 rad/sec bandwidth
Input phases
Three-phase input provides full rating for all drives. single-phase ops provides 50% of rated current
Control method
Sine coded PWM with progmable carrier frequency. Ratings apply to all drives
Number of HW-interfaces RS-232
2
Number of HW-interfaces RS-485
2
Number of HW-interfaces USB
2
Number of phases output
3
Number of phases input
3
Relative symmetric net voltage tolerance
10 %
With control element
Yes
Supporting protocol for TCP/IP
Yes
Supporting protocol for PROFIBUS
Yes
Supporting protocol for CAN
Yes
Supporting protocol for Modbus
Yes
Application in domestic- and commercial area permitted
Yes
Motor overload protection
Class 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL 508C file E59272
Input frequency tolerance
47 Hz
Encoder duty cycle
50% ±10%
Voltage tolerance
-10 %
Displacement power factor (all drives)
0.98 across speed range
Short circuit rating, max
200000 A symmetrical
Output voltage range
0 to rated motor voltage
Encoder type
Incremental, dual channel
Power ride-thru
15 ms at full load
Short circuit trip
Phase-to-phase on drive output
Ground fault trip
Phase-to-ground on drive output
Drive to motor power ratio, min
Recommended not less than 1:2 ratio
Control logic noise immunity
Showering arc transients upto 1500V peak
Line transients
Up to 6000 volts peak per IEEE C62.41-1991
Short circuit current rating, max
Maximum short circuit current rating to match specified fuse/circuit breaker capability
Intermittent overload
110% overload capability for up to 1 min, 150% overload capability for up to 3 s
Height, approx
IP66, NEMA/UL Type 4X/12 for indoor use: 350 mm
Depth, approx
IP66, NEMA/UL Type 4X/12 for indoor use: 210.7 mm
Width, approx
IP66, NEMA/UL Type 4X/12 for indoor use: 219.9 mm
Weight, approx
IP66, NEMA/UL Type 4X/12 for indoor use: 9.13 kg
Altitude
1000 m (3300 ft.) maximum without derating
Degree of protection (NEMA)
4X
Surrounding air temperature, max
Flange mount: 0...50 °C (32...122 °F) without derating
Atmosphere
Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors or dust, If the drive is not going to be installed immediately, store the drive where it is not exposed to a corrosive atmosphere
Storage temperature
-40 °C
Relative humidity
5...95% noncondensing
Pollution degree 1 according to EN 61800-5-1
No pollution occurs, only dry non-conductive pollution occurs, and has no influence
Pollution degree 4 according to EN 61800-5-1
The pollution generates persistent conductivity caused, for exAle, by conductive dust, rain or snow
Pollution degree 3 according to EN 61800-5-1
Conductive pollution occurs, dry non-conductive pollution occurs and becomes conductive due to condensation
Pollution degree 2 according to EN 61800-5-1
Normally only non-conductive pollution occurs, Occasionally a temporary conductivity, caused by condensation is expected when the drive is out of ops
Surrounding environment pollution degree
All enclosures are acceptable for pollution degree 1 and 2, an enclosure that meets or exceeds IP54, NEMA/UL type 12, is required for pollution degree 3 and 4
图纸
PowerTerminal Block Drawing 下载 (PDF)
3D STEP (STP) Model 下载 (ZIP)
2D Dimension Drawing (PDF) 下载 (PDF)
Dimension Drawing (Catalog Pages) 下载 (PDF)
Control Terminal Block Drawing 下载 (PDF)
2D Dimension Drawing (DWG/DXF) 下载 (ZIP)
图纸
PowerTerminal Block Drawing 下载 (PDF)
3D STEP (STP) Model 下载 (ZIP)
2D Dimension Drawing (PDF) 下载 (PDF)
Dimension Drawing (Catalog Pages) 下载 (PDF)
Control Terminal Block Drawing 下载 (PDF)
2D Dimension Drawing (DWG/DXF) 下载 (ZIP)
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
类型 资源 出版
Application Techniques APPLICATION_TECHNIQUES_pflex-at001_-en-p PFLEX-AT001
Installation Instructions INSTALLATION_INSTRUCTIONS_20a-in002_-mu-p 20A-IN002
Quick Reference QUICK_REFERENCE_20him-qr001_-mu-p 20HIM-QR001
Reference Manual REFERENCE_MANUAL_pflex-rm004_-en-e PFLEX-RM004
Technical Data 20a-td001_-en-p 20A-TD001
User Manual USER_MANUAL_20a-um001_-en-p 20A-UM001
Wiring Diagram WIRING_DIAGRAM_21vw-wd002_-en-p 21VW-WD002
常规 Product Cutsheet --
常规 Product Brochure --
常规 Fuse Size Table --
常规 Wire Size Table --
常规 Parameter List --
常规 Product Profile --
常规 PowerFlex 70 700 Reference Manual - Vol 1 PFLEX-RM001
常规 Specification Sheet --
常规 Drive Specification --
常规 Routine Maintenance Guidelines --
常规 User Manual Documentation Update --
常规 User Manual --
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
Eurasion Economic Community Australian RCM UL Listed Korean KC
  • Eurasion Economic Community
  • CE
  • Lloyds Register
  • Australian RCM
  • Safety
  • Seismic
  • Semiconductor Inds Immunit
  • UL Listed
  • Korean KC

This product was certified with the above certifications as of 2025-12-24. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

每页项目:
1-1 关于 1
每页项目:
1-1 关于 1
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
技术规格
Brake IGBT
Brake IGBT Installed
Brake Resistor
No Internal
Control And I/O
Enhanced Control with 24V I/O
Feedback Options
No ftdback
Filter Options
W/ EMC Filt & ComModeChoke
Internal Communication Module
No Communication Module
Sub Brand
PowerFlex 70 AC Drive
Degree of protection (IP)
IP66
Shock
15 G peak for 11 ms duration (±1.0 ms)
Vibration
0.152 mm (0.006 in) displacement, 1 G peak
Number of analogue outputs
1
Mains voltage
400 V
Integrated breaking resistance
No
Internal dynamic brake resistors
62 ohm
Brake IGBT
Brake IGBT installed
Bus undervoltage output shutoff
305V DC @ 380/400V
Bus undervoltage fault level
300V DC @ 380/400V
Internal communication module
No communication module
AC input undervoltage trip
233V AC @ 380/400V
Bus voltage, nom
540V DC @ 380/400V
Bus overvoltage trip
810V DC @ 380/400V
Circuit breaker current rating, max
120A @ 400V AC, 3-phase
Motor circuit protector current rating, max
50A @ 400V AC, 3-phase
Output current rating, continuous
30A @ 400V AC, 3-phase
Output current rating, 1 min
33A @ 400V AC, 3-phase
Output current rating, 3 sec
45A @ 400V AC, 3-phase
Logic control ride-thru
0.5 s minimum, 2 s typical
Brake resistor
Without drive mounted brake resistor
Input current rating
30.3A @ 400V AC, 3-phase
Documentation
Manual
Carrier frequency
Standard control: 2, 3, 4, 5, 6, 7, 8, 9, and 10 kHz, vector control: 2, 4, 8, and 12 kHz, drive rating based on 4 kHz
Encoder quadrature
90° ±27°
AC input overvoltage trip
475V AC @ 380/400V
Input power rating
21 kVA @ 400V AC, 3-phase
Dual element time delay fuse current rating
40...60A @ 400V AC, 3-phase
Non-time delay fuse current rating
40...120A @ 400V AC, 3-phase
Heat sink thermistor
Monitored by microprocessor overtemp trip
Drive to motor power ratio, max
Recommended not greater than 2:1 ratio
Stop modes
Multiple progmable stop modes including - RA, Coast, DC-brake, Fast brake, RA-to-hold and S-curve
Acceleration/deceleration
Two independently progmable accel and decel times. Each time can be progmed from 0...3600 s in 0.1 s increments
Frequency accuracy
Digital input: within ±0.01% of set output frequency
Number of digital inputs
6
Number of digital outputs
2
Internal watts loss
42.9 W @ 400V @ 15Hp normal duty
Number of analogue inputs
2
Motor voltage, nom
460V @ 380...480V drive rating, 480V nominal line voltage
Human interface model
No HIM-blank plate
Supporting protocol for DeviceNet
Yes
Application in industrial area permitted
Yes
External watts loss
432.9 W @ 400V @ 15Hp normal duty
Total watts loss
475.8 W @ 400V @ 15Hp normal duty
Line voltage, nom
480V @ 380...480V drive rating, 460V nominal motor voltage
Supporting protocol for EtherNet/IP
Yes
Mains frequency
50 Hz
Output frequency range
Standard control: 0...400 Hz, enhanced control: 0...500 Hz
Internal EMC filtering
S environment filter per CE EMC directive (89/336/EEC)
Feedback option
No ftdback
Drive full power range
460...528V @ 380...480V drive rating, 460V nominal motor voltage
Drive operating range
342...528V @ 380...480V drive rating, 460V nominal motor voltage
Torque regulation
Without ftdback +/-10%, with ftdback +/-5%
Enclosure type
Flanged Mount - Front IP20, NEMA Type 1, Rear = NEMA Type 4X/12 (Indoor /Outdoor)
Output current rating
30 A, 15 kW normal duty, 11 kW heavy duty, frame D
Cooling fan operation
Frames B, D, and E: fan operates when power is applied and in run condition
Control options
Enhanced control with 24V I/O
Drive overcurrent trip
Software current limit: 20...160% of rated current
Efficiency
97.5% at rated A, nominal line volts
Encoder supply
5V/12V configurable ±5%
Speed control-speed regulation
Without ftdback (Vector Control mode): 0.1% of base speed across 120:1 speed range, 120:1 operating range, 30 rad/sec bandwidth
Current limit capability
Proactive current limit progmable from 20...160% of rated output current, Independently progmable proportional and integral gain
Selectable motor control
Sensorless vector with full tuning. Standards V/Hz with full custom capability and vector control
Frequency control-speed regulation
With slip compensation (Volts per Hz mode): 0.5% of base speed across 40:1 speed range, 40:1 operating range, 10 rad/sec bandwidth
Input phases
Three-phase input provides full rating for all drives. single-phase ops provides 50% of rated current
Control method
Sine coded PWM with progmable carrier frequency. Ratings apply to all drives
Number of HW-interfaces RS-232
2
Number of HW-interfaces RS-485
2
Number of HW-interfaces USB
2
Number of phases output
3
Number of phases input
3
Relative symmetric net voltage tolerance
10 %
With control element
Yes
Supporting protocol for TCP/IP
Yes
Supporting protocol for PROFIBUS
Yes
Supporting protocol for CAN
Yes
Supporting protocol for Modbus
Yes
Application in domestic- and commercial area permitted
Yes
Motor overload protection
Class 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL 508C file E59272
Input frequency tolerance
47 Hz
Encoder duty cycle
50% ±10%
Voltage tolerance
-10 %
Displacement power factor (all drives)
0.98 across speed range
Short circuit rating, max
200000 A symmetrical
Output voltage range
0 to rated motor voltage
Encoder type
Incremental, dual channel
Power ride-thru
15 ms at full load
Short circuit trip
Phase-to-phase on drive output
Ground fault trip
Phase-to-ground on drive output
Drive to motor power ratio, min
Recommended not less than 1:2 ratio
Control logic noise immunity
Showering arc transients upto 1500V peak
Line transients
Up to 6000 volts peak per IEEE C62.41-1991
Short circuit current rating, max
Maximum short circuit current rating to match specified fuse/circuit breaker capability
Intermittent overload
110% overload capability for up to 1 min, 150% overload capability for up to 3 s
Height, approx
IP66, NEMA/UL Type 4X/12 for indoor use: 350 mm
Depth, approx
IP66, NEMA/UL Type 4X/12 for indoor use: 210.7 mm
Width, approx
IP66, NEMA/UL Type 4X/12 for indoor use: 219.9 mm
Weight, approx
IP66, NEMA/UL Type 4X/12 for indoor use: 9.13 kg
Altitude
1000 m (3300 ft.) maximum without derating
Degree of protection (NEMA)
4X
Surrounding air temperature, max
Flange mount: 0...50 °C (32...122 °F) without derating
Atmosphere
Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors or dust, If the drive is not going to be installed immediately, store the drive where it is not exposed to a corrosive atmosphere
Storage temperature
-40 °C
Relative humidity
5...95% noncondensing
Pollution degree 1 according to EN 61800-5-1
No pollution occurs, only dry non-conductive pollution occurs, and has no influence
Pollution degree 4 according to EN 61800-5-1
The pollution generates persistent conductivity caused, for exAle, by conductive dust, rain or snow
Pollution degree 3 according to EN 61800-5-1
Conductive pollution occurs, dry non-conductive pollution occurs and becomes conductive due to condensation
Pollution degree 2 according to EN 61800-5-1
Normally only non-conductive pollution occurs, Occasionally a temporary conductivity, caused by condensation is expected when the drive is out of ops
Surrounding environment pollution degree
All enclosures are acceptable for pollution degree 1 and 2, an enclosure that meets or exceeds IP54, NEMA/UL type 12, is required for pollution degree 3 and 4
图纸
图纸
PowerTerminal Block Drawing 下载 (PDF)
3D STEP (STP) Model 下载 (ZIP)
2D Dimension Drawing (PDF) 下载 (PDF)
Dimension Drawing (Catalog Pages) 下载 (PDF)
Control Terminal Block Drawing 下载 (PDF)
2D Dimension Drawing (DWG/DXF) 下载 (ZIP)
图纸
PowerTerminal Block Drawing 下载 (PDF)
3D STEP (STP) Model 下载 (ZIP)
2D Dimension Drawing (PDF) 下载 (PDF)
Dimension Drawing (Catalog Pages) 下载 (PDF)
Control Terminal Block Drawing 下载 (PDF)
2D Dimension Drawing (DWG/DXF) 下载 (ZIP)
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
APPLICATION_TECHNIQUES_pflex-at001_-en-p Application Techniques
PFLEX-AT001
INSTALLATION_INSTRUCTIONS_20a-in002_-mu-p Installation Instructions
20A-IN002
QUICK_REFERENCE_20him-qr001_-mu-p Quick Reference
20HIM-QR001
REFERENCE_MANUAL_pflex-rm004_-en-e Reference Manual
PFLEX-RM004
20a-td001_-en-p Technical Data
20A-TD001
USER_MANUAL_20a-um001_-en-p User Manual
20A-UM001
WIRING_DIAGRAM_21vw-wd002_-en-p Wiring Diagram
21VW-WD002
Product Cutsheet 常规
--
Product Brochure 常规
--
Fuse Size Table 常规
--
Wire Size Table 常规
--
Parameter List 常规
--
Product Profile 常规
--
PowerFlex 70 700 Reference Manual - Vol 1 常规
PFLEX-RM001
Specification Sheet 常规
--
Drive Specification 常规
--
Routine Maintenance Guidelines 常规
--
User Manual Documentation Update 常规
--
User Manual 常规
--
类型 资源 出版
Application Techniques APPLICATION_TECHNIQUES_pflex-at001_-en-p PFLEX-AT001
Installation Instructions INSTALLATION_INSTRUCTIONS_20a-in002_-mu-p 20A-IN002
Quick Reference QUICK_REFERENCE_20him-qr001_-mu-p 20HIM-QR001
Reference Manual REFERENCE_MANUAL_pflex-rm004_-en-e PFLEX-RM004
Technical Data 20a-td001_-en-p 20A-TD001
User Manual USER_MANUAL_20a-um001_-en-p 20A-UM001
Wiring Diagram WIRING_DIAGRAM_21vw-wd002_-en-p 21VW-WD002
常规 Product Cutsheet --
常规 Product Brochure --
常规 Fuse Size Table --
常规 Wire Size Table --
常规 Parameter List --
常规 Product Profile --
常规 PowerFlex 70 700 Reference Manual - Vol 1 PFLEX-RM001
常规 Specification Sheet --
常规 Drive Specification --
常规 Routine Maintenance Guidelines --
常规 User Manual Documentation Update --
常规 User Manual --
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
认证
Eurasion Economic Community Australian RCM UL Listed Korean KC
  • Eurasion Economic Community
  • CE
  • Lloyds Register
  • Australian RCM
  • Safety
  • Seismic
  • Semiconductor Inds Immunit
  • UL Listed
  • Korean KC

This product was certified with the above certifications as of 2025-12-24. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

配件
每页项目:
1-1 关于 1
替代产品
每页项目:
1-1 关于 1
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
Loading
寻找最近经销商
Contact your distributor in {0}
更改位置
EmailEmail
PhonePhone
寻找合作伙伴
PowerFlex 70 AC Drive 30 A at 15 kW 20A
CloseClose
20AC030F0AYNANC0
关闭
打印
Chevron LeftChevron Left
Allen-Bradley 20AC030F0AYNANC0 product image
Chevron LeftChevron Left
Allen-Bradley 20AC030F0AYNANC0 product image
Allen-Bradley 20AC030F0AYNANC0 product image
电话:
呼叫
Rockwell Automation Home