Loading
Allen-Bradley 20AC022A3AYNANG0 product image
Allen Bradley

PowerFlex 70 AC Drive 22 A at 11 kW 20A

PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Catalog #: 20AC022A3AYNANG0
Lifecycle status: Discontinued
ErrorsErrors
Rockwell Automation announces that as of June 01, 2023, the PowerFlex 70 AC Drive 22 A at 11 kW 20A will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s).
Discontinued Date: June 01, 2023 Replacement Category: Direct Replacement
Allen-Bradley 20AC022A3AYNANG0 product image
Allen Bradley
PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Lifecycle status: Discontinued
ErrorsErrors
Rockwell Automation announces that as of June 01, 2023, the PowerFlex 70 AC Drive 22 A at 11 kW 20A will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s).
Discontinued Date: June 01, 2023 Replacement Category: Direct Replacement
Add to BoM
  • Add to Repair Quote
  • Get Support
Technical Specifications
Documents
Certifications
Alternative Products
Technotes
Brake Resistor No Internal
Control And I/O Enh Control, with Safe-Off
Feedback Options No ftdback
Filter Options W/ EMC Filt & ComModeChoke
Internal Communication Module No Communication Module
Degree of protection (IP) IP20
Shock 15 G peak for 11 ms duration (±1.0 ms)
Vibration 0.152 mm (0.006 in) displacement, 1 G peak
Number of analogue outputs 1
Mains voltage 400 V
Integrated breaking resistance False
Internal dynamic brake resistors 62 ohm
Brake IGBT Brake IGBT installed
Bus undervoltage output shutoff 305V DC @ 380/400V
Bus undervoltage fault level 300V DC @ 380/400V
Internal communication module No communication module
AC input undervoltage trip 233V AC @ 380/400V
Bus voltage, nom 540V DC @ 380/400V
Bus overvoltage trip 810V DC @ 380/400V
Circuit breaker current rating, max 80A @ 400V AC, 3-phase
Motor circuit protector current rating, max 30A @ 400V AC, 3-phase
Output current rating, continuous 22A @ 400V AC, 3-phase
Output current rating, 1 min 24.2A @ 400V AC, 3-phase
Output current rating, 3 sec 33A @ 400V AC, 3-phase
Logic control ride-thru 0.5 s minimum, 2 s typical
Brake resistor Without drive mounted brake resistor
Input current rating 21.9A @ 400V AC, 3-phase
Documentation Manual
Carrier frequency Standard control: 2, 3, 4, 5, 6, 7, 8, 9, and 10 kHz, vector control: 2, 4, 8, and 12 kHz, drive rating based on 4 kHz
Encoder quadrature 90° ±27°
AC input overvoltage trip 475V AC @ 380/400V
Input power rating 7.6 kVA @ 400V AC, 1-phase
Dual element time delay fuse current rating 30...45A @ 400V AC, 3-phase
Non-time delay fuse current rating 30...80A @ 400V AC, 3-phase
Heat sink thermistor Monitored by microprocessor overtemp trip
Drive to motor power ratio, max Recommended not greater than 2:1 ratio
Stop modes Multiple progmable stop modes including - RA, Coast, DC-brake, Fast brake, RA-to-hold and S-curve
Acceleration/deceleration Two independently progmable accel and decel times. Each time can be progmed from 0...3600 s in 0.1 s increments
Frequency accuracy Digital input: within ±0.01% of set output frequency
Number of digital inputs 6
Number of digital outputs 2
Internal watts loss 34.2 W @ 400V @ 11Hp normal duty
Number of analogue inputs 2
Motor voltage, nom 460V @ 380...480V drive rating, 480V nominal line voltage
Human interface model LCD display, full numeric keypad
Supporting protocol for DeviceNet True
Application in industrial area permitted True
External watts loss 305.4 W @ 400V @ 11Hp normal duty
Total watts loss 339.6 W @ 400V @ 11Hp normal duty
Line voltage, nom 480V @ 380...480V drive rating, 460V nominal motor voltage
Supporting protocol for EtherNet/IP True
Mains frequency 50 Hz
Output frequency range Standard control: 0...400 Hz, enhanced control: 0...500 Hz
Internal EMC filtering S environment filter per CE EMC directive (89/336/EEC)
Feedback option No ftdback
Drive full power range 460...528V @ 380...480V drive rating, 460V nominal motor voltage
Drive operating range 342...528V @ 380...480V drive rating, 460V nominal motor voltage
Torque regulation Without ftdback +/-10%, with ftdback +/-5%
Enclosure type Panel mount-IP20/NEMA Type 1
Output current rating 22 A, 11 kW normal duty, 7.5 kW heavy duty, frame D
Cooling fan operation Frames B, D, and E: fan operates when power is applied and in run condition
Control options Enhanced control with safe torque off
Drive overcurrent trip Software current limit: 20...160% of rated current
Efficiency 97.5% at rated A, nominal line volts
Encoder supply 5V/12V configurable ±5%
Speed control-speed regulation Without ftdback (Vector Control mode): 0.1% of base speed across 120:1 speed range, 120:1 operating range, 30 rad/sec bandwidth
Current limit capability Proactive current limit progmable from 20...160% of rated output current, Independently progmable proportional and integral gain
Selectable motor control Sensorless vector with full tuning. Standards V/Hz with full custom capability and vector control
Frequency control-speed regulation With slip compensation (Volts per Hz mode): 0.5% of base speed across 40:1 speed range, 40:1 operating range, 10 rad/sec bandwidth
Input phases Three-phase input provides full rating for all drives. single-phase ops provides 50% of rated current
Control method Sine coded PWM with progmable carrier frequency. Ratings apply to all drives
Number of HW-interfaces RS-232 2
Number of HW-interfaces RS-485 2
Number of HW-interfaces USB 2
Number of phases output 3
Number of phases input 3
Relative symmetric net voltage tolerance 10 %
With control element True
Supporting protocol for TCP/IP True
Supporting protocol for PROFIBUS True
Supporting protocol for CAN True
Supporting protocol for Modbus True
Application in domestic- and commercial area permitted True
Motor overload protection Class 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL 508C file E59272
Input frequency tolerance 47 Hz
Encoder duty cycle 50% ±10%
Voltage tolerance -10 %
Displacement power factor (all drives) 0.98 across speed range
Short circuit rating, max 200000 A symmetrical
Output voltage range 0 to rated motor voltage
Encoder type Incremental, dual channel
Power ride-thru 15 ms at full load
Short circuit trip Phase-to-phase on drive output
Ground fault trip Phase-to-ground on drive output
Drive to motor power ratio, min Recommended not less than 1:2 ratio
Control logic noise immunity Showering arc transients upto 1500V peak
Line transients Up to 6000 volts peak per IEEE C62.41-1991
Short circuit current rating, max Maximum short circuit current rating to match specified fuse/circuit breaker capability
Intermittent overload 110% overload capability for up to 1 min, 150% overload capability for up to 3 s
Height, approx IP66, NEMA/UL Type 4X/12 for indoor use: 350 mm
Depth, approx IP66, NEMA/UL Type 4X/12 for indoor use: 210.7 mm
Width, approx IP66, NEMA/UL Type 4X/12 for indoor use: 219.9 mm
Weight, approx IP66, NEMA/UL Type 4X/12 for indoor use: 9.13 kg
Altitude 1000 m (3300 ft.) maximum without derating
Degree of protection (NEMA) 1
Surrounding air temperature, max IP20, NEMA/UL Type 1: 0...50 °C (32...122 °F) without derating
Atmosphere Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors or dust, If the drive is not going to be installed immediately, store the drive where it is not exposed to a corrosive atmosphere
Storage temperature -40 °C
Relative humidity 5...95% noncondensing
Pollution degree 1 according to EN 61800-5-1 No pollution occurs, only dry non-conductive pollution occurs, and has no influence
Pollution degree 4 according to EN 61800-5-1 The pollution generates persistent conductivity caused, for exAle, by conductive dust, rain or snow
Pollution degree 3 according to EN 61800-5-1 Conductive pollution occurs, dry non-conductive pollution occurs and becomes conductive due to condensation
Pollution degree 2 according to EN 61800-5-1 Normally only non-conductive pollution occurs, Occasionally a temporary conductivity, caused by condensation is expected when the drive is out of ops
Surrounding environment pollution degree All enclosures are acceptable for pollution degree 1 and 2, an enclosure that meets or exceeds IP54, NEMA/UL type 12, is required for pollution degree 3 and 4
Sales Info
Repairable REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 33.299
Lead Time 53
Dimension Width 32.995
Dimension Length 45.11
Stock Status NON_STOCKED
Weight 10.786
Weight Unit KG
Dimension Unit CM
类型 资源 发布
Application Techniques APPLICATION_TECHNIQUES_pflex-at001_-en-p PFLEX-AT001
Installation Instructions INSTALLATION_INSTRUCTIONS_20a-in002_-mu-p 20A-IN002
Quick Reference QUICK_REFERENCE_20him-qr001_-mu-p 20HIM-QR001
Reference Manual REFERENCE_MANUAL_pflex-rm004_-en-e PFLEX-RM004
Technical Data 20a-td001_-en-p 20A-TD001
User Manual USER_MANUAL_20a-um001_-en-p 20A-UM001
Wiring Diagram WIRING_DIAGRAM_21vw-wd002_-en-p 21VW-WD002
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library Chevron RightChevron Right
Eurasion Economic Community
  • Eurasion Economic Community

This product was certified with the above certifications as of 2025-04-14. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

每页条目数:
1-1 的 1
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Technical Specifications
Brake Resistor No Internal
Control And I/O Enh Control, with Safe-Off
Feedback Options No ftdback
Filter Options W/ EMC Filt & ComModeChoke
Internal Communication Module No Communication Module
Degree of protection (IP) IP20
Shock 15 G peak for 11 ms duration (±1.0 ms)
Vibration 0.152 mm (0.006 in) displacement, 1 G peak
Number of analogue outputs 1
Mains voltage 400 V
Integrated breaking resistance False
Internal dynamic brake resistors 62 ohm
Brake IGBT Brake IGBT installed
Bus undervoltage output shutoff 305V DC @ 380/400V
Bus undervoltage fault level 300V DC @ 380/400V
Internal communication module No communication module
AC input undervoltage trip 233V AC @ 380/400V
Bus voltage, nom 540V DC @ 380/400V
Bus overvoltage trip 810V DC @ 380/400V
Circuit breaker current rating, max 80A @ 400V AC, 3-phase
Motor circuit protector current rating, max 30A @ 400V AC, 3-phase
Output current rating, continuous 22A @ 400V AC, 3-phase
Output current rating, 1 min 24.2A @ 400V AC, 3-phase
Output current rating, 3 sec 33A @ 400V AC, 3-phase
Logic control ride-thru 0.5 s minimum, 2 s typical
Brake resistor Without drive mounted brake resistor
Input current rating 21.9A @ 400V AC, 3-phase
Documentation Manual
Carrier frequency Standard control: 2, 3, 4, 5, 6, 7, 8, 9, and 10 kHz, vector control: 2, 4, 8, and 12 kHz, drive rating based on 4 kHz
Encoder quadrature 90° ±27°
AC input overvoltage trip 475V AC @ 380/400V
Input power rating 7.6 kVA @ 400V AC, 1-phase
Dual element time delay fuse current rating 30...45A @ 400V AC, 3-phase
Non-time delay fuse current rating 30...80A @ 400V AC, 3-phase
Heat sink thermistor Monitored by microprocessor overtemp trip
Drive to motor power ratio, max Recommended not greater than 2:1 ratio
Stop modes Multiple progmable stop modes including - RA, Coast, DC-brake, Fast brake, RA-to-hold and S-curve
Acceleration/deceleration Two independently progmable accel and decel times. Each time can be progmed from 0...3600 s in 0.1 s increments
Frequency accuracy Digital input: within ±0.01% of set output frequency
Number of digital inputs 6
Number of digital outputs 2
Internal watts loss 34.2 W @ 400V @ 11Hp normal duty
Number of analogue inputs 2
Motor voltage, nom 460V @ 380...480V drive rating, 480V nominal line voltage
Human interface model LCD display, full numeric keypad
Supporting protocol for DeviceNet True
Application in industrial area permitted True
External watts loss 305.4 W @ 400V @ 11Hp normal duty
Total watts loss 339.6 W @ 400V @ 11Hp normal duty
Line voltage, nom 480V @ 380...480V drive rating, 460V nominal motor voltage
Supporting protocol for EtherNet/IP True
Mains frequency 50 Hz
Output frequency range Standard control: 0...400 Hz, enhanced control: 0...500 Hz
Internal EMC filtering S environment filter per CE EMC directive (89/336/EEC)
Feedback option No ftdback
Drive full power range 460...528V @ 380...480V drive rating, 460V nominal motor voltage
Drive operating range 342...528V @ 380...480V drive rating, 460V nominal motor voltage
Torque regulation Without ftdback +/-10%, with ftdback +/-5%
Enclosure type Panel mount-IP20/NEMA Type 1
Output current rating 22 A, 11 kW normal duty, 7.5 kW heavy duty, frame D
Cooling fan operation Frames B, D, and E: fan operates when power is applied and in run condition
Control options Enhanced control with safe torque off
Drive overcurrent trip Software current limit: 20...160% of rated current
Efficiency 97.5% at rated A, nominal line volts
Encoder supply 5V/12V configurable ±5%
Speed control-speed regulation Without ftdback (Vector Control mode): 0.1% of base speed across 120:1 speed range, 120:1 operating range, 30 rad/sec bandwidth
Current limit capability Proactive current limit progmable from 20...160% of rated output current, Independently progmable proportional and integral gain
Selectable motor control Sensorless vector with full tuning. Standards V/Hz with full custom capability and vector control
Frequency control-speed regulation With slip compensation (Volts per Hz mode): 0.5% of base speed across 40:1 speed range, 40:1 operating range, 10 rad/sec bandwidth
Input phases Three-phase input provides full rating for all drives. single-phase ops provides 50% of rated current
Control method Sine coded PWM with progmable carrier frequency. Ratings apply to all drives
Number of HW-interfaces RS-232 2
Number of HW-interfaces RS-485 2
Number of HW-interfaces USB 2
Number of phases output 3
Number of phases input 3
Relative symmetric net voltage tolerance 10 %
With control element True
Supporting protocol for TCP/IP True
Supporting protocol for PROFIBUS True
Supporting protocol for CAN True
Supporting protocol for Modbus True
Application in domestic- and commercial area permitted True
Motor overload protection Class 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL 508C file E59272
Input frequency tolerance 47 Hz
Encoder duty cycle 50% ±10%
Voltage tolerance -10 %
Displacement power factor (all drives) 0.98 across speed range
Short circuit rating, max 200000 A symmetrical
Output voltage range 0 to rated motor voltage
Encoder type Incremental, dual channel
Power ride-thru 15 ms at full load
Short circuit trip Phase-to-phase on drive output
Ground fault trip Phase-to-ground on drive output
Drive to motor power ratio, min Recommended not less than 1:2 ratio
Control logic noise immunity Showering arc transients upto 1500V peak
Line transients Up to 6000 volts peak per IEEE C62.41-1991
Short circuit current rating, max Maximum short circuit current rating to match specified fuse/circuit breaker capability
Intermittent overload 110% overload capability for up to 1 min, 150% overload capability for up to 3 s
Height, approx IP66, NEMA/UL Type 4X/12 for indoor use: 350 mm
Depth, approx IP66, NEMA/UL Type 4X/12 for indoor use: 210.7 mm
Width, approx IP66, NEMA/UL Type 4X/12 for indoor use: 219.9 mm
Weight, approx IP66, NEMA/UL Type 4X/12 for indoor use: 9.13 kg
Altitude 1000 m (3300 ft.) maximum without derating
Degree of protection (NEMA) 1
Surrounding air temperature, max IP20, NEMA/UL Type 1: 0...50 °C (32...122 °F) without derating
Atmosphere Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors or dust, If the drive is not going to be installed immediately, store the drive where it is not exposed to a corrosive atmosphere
Storage temperature -40 °C
Relative humidity 5...95% noncondensing
Pollution degree 1 according to EN 61800-5-1 No pollution occurs, only dry non-conductive pollution occurs, and has no influence
Pollution degree 4 according to EN 61800-5-1 The pollution generates persistent conductivity caused, for exAle, by conductive dust, rain or snow
Pollution degree 3 according to EN 61800-5-1 Conductive pollution occurs, dry non-conductive pollution occurs and becomes conductive due to condensation
Pollution degree 2 according to EN 61800-5-1 Normally only non-conductive pollution occurs, Occasionally a temporary conductivity, caused by condensation is expected when the drive is out of ops
Surrounding environment pollution degree All enclosures are acceptable for pollution degree 1 and 2, an enclosure that meets or exceeds IP54, NEMA/UL type 12, is required for pollution degree 3 and 4
Sales Info
Repairable REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 33.299
Lead Time 53
Dimension Width 32.995
Dimension Length 45.11
Stock Status NON_STOCKED
Weight 10.786
Weight Unit KG
Dimension Unit CM
文档
APPLICATION_TECHNIQUES_pflex-at001_-en-p Application Techniques
PFLEX-AT001
INSTALLATION_INSTRUCTIONS_20a-in002_-mu-p Installation Instructions
20A-IN002
QUICK_REFERENCE_20him-qr001_-mu-p Quick Reference
20HIM-QR001
REFERENCE_MANUAL_pflex-rm004_-en-e Reference Manual
PFLEX-RM004
20a-td001_-en-p Technical Data
20A-TD001
USER_MANUAL_20a-um001_-en-p User Manual
20A-UM001
WIRING_DIAGRAM_21vw-wd002_-en-p Wiring Diagram
21VW-WD002
类型 资源 发布
Application Techniques APPLICATION_TECHNIQUES_pflex-at001_-en-p PFLEX-AT001
Installation Instructions INSTALLATION_INSTRUCTIONS_20a-in002_-mu-p 20A-IN002
Quick Reference QUICK_REFERENCE_20him-qr001_-mu-p 20HIM-QR001
Reference Manual REFERENCE_MANUAL_pflex-rm004_-en-e PFLEX-RM004
Technical Data 20a-td001_-en-p 20A-TD001
User Manual USER_MANUAL_20a-um001_-en-p 20A-UM001
Wiring Diagram WIRING_DIAGRAM_21vw-wd002_-en-p 21VW-WD002
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library Chevron RightChevron Right
认证
Eurasion Economic Community
  • Eurasion Economic Community

This product was certified with the above certifications as of 2025-04-14. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Alternative Products
每页条目数:
1-1 的 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Loading
Find your nearest distributor
Change location
EmailEmail
PhonePhone
Find a partner Chevron RightChevron Right
PowerFlex 70 AC Drive 22 A at 11 kW 20A
CloseClose
20AC022A3AYNANG0
关闭
打印
Allen-Bradley 20AC022A3AYNANG0 product image
手机:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页 Chevron RightChevron Right
  2. Chevron LeftChevron Left 产品 Chevron RightChevron Right
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose