| I/O Isolation | None |
|---|
| Number of analogue inputs | 2 |
|---|---|
| Resolution of the analogue inputs | 14 bit |
| Resolution of the analogue outputs | 14 bit |
| Input, current | False |
| Input, voltage | False |
| Input, resistor | True |
| Input, resistance thermometer | False |
| Input, thermocouple | False |
| Input signal, configurable | False |
| Output, current | False |
| Output, voltage | False |
| Output signal configurable | False |
| Analogue inputs configurable | False |
| Analogue outputs configurable | False |
| Type of electric connection | Screw connection |
| Normal mode rejection ratio | 70 dB @ 50/60 Hz |
| Accuracy | ±1.0 °C @ 25 °C (77 °F) |
| Wire size | Solid: 0.14 mm2 AWG)...1.5 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum, Stranded: 0.14 mm2 AWG)...1.0 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum |
| Open circuit detection time | 8 to 1212 |
| Suitable for safety functions | False |
| SIL according to IEC 61508 | None |
| Common mode rejection ratio | 100 dB @ 50/60Hz |
| RTD types supported | 100 Ω Platinum 385, 200 Ω Platinum 385, 500 Ω Platinum 385, 1000 Ω Platinum 385, 100 Ω Platinum 392, 200 Ω Platinum 392, 500 Ω Platinum 392, 1000 Ω Platinum 392, 10 Ω Copper 427, 120 Ω Nickel 672, 604 Ω Nickel-Iron 518 |
| Surrounding air temperature, max | 65 °C |
|---|---|
| North American temperature code | T4 |
| Power consumption | 40mA @ 3.3V |
| Emissions | CISPR 11 (IEC 61000-6-4): Class A |
| ESD immunity | IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges |
| EFT/B immunity | IEC 61000-4-4: ±2kV @ 5kHz on shielded ports |
| Conducted RF immunity | IEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz |
| Surge transient immunity | IEC 61000-4-5: ±2 kV line-earth(CM) on shielded ports |
| Operating temperature | -20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock) |
| Radiated RF immunity | IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz, |
| Nonoperating temperature | -40...85 °C (-40...185 °F), IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) |
| Vibration | IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz |
|---|---|
| Shock | IEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating |
| Mounting torque | 0.2 nm |
| Terminal screw torque | 0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver) |
| Input impedance | >5 MΩ |
|---|
| Explosion safety category for gas | None |
|---|---|
| Explosion safety category for dust | None |
| 图纸 | |
|---|---|
| 3D STP (STEP) Model | Download (ZIP) |
| Product Drawing | Drawing (DXF) |
| 图纸 |
|---|
| 3D STP (STEP) Model Download (ZIP) |
| Product Drawing Drawing (DXF) |
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
| 类型 | 资源 | 出版 |
|---|---|---|
| General | Brochure | -- |
| General | Wiring Diagram | -- |
| General | Product Cutsheet | -- |
| General | Installation Guide | -- |
| User Manual | 2080-um004_-en-e | 2080-UM004 |
| User Manual | Micro800 Plug-in Modules User Manual | 2080-UM002 |
- Korean Register of Shippin
This product was certified with the above certifications as of 2025-09-09. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
技术规格
| I/O Isolation | None |
|---|
| Number of analogue inputs | 2 |
|---|---|
| Resolution of the analogue inputs | 14 bit |
| Resolution of the analogue outputs | 14 bit |
| Input, current | False |
| Input, voltage | False |
| Input, resistor | True |
| Input, resistance thermometer | False |
| Input, thermocouple | False |
| Input signal, configurable | False |
| Output, current | False |
| Output, voltage | False |
| Output signal configurable | False |
| Analogue inputs configurable | False |
| Analogue outputs configurable | False |
| Type of electric connection | Screw connection |
| Normal mode rejection ratio | 70 dB @ 50/60 Hz |
| Accuracy | ±1.0 °C @ 25 °C (77 °F) |
| Wire size | Solid: 0.14 mm2 AWG)...1.5 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum, Stranded: 0.14 mm2 AWG)...1.0 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum |
| Open circuit detection time | 8 to 1212 |
| Suitable for safety functions | False |
| SIL according to IEC 61508 | None |
| Common mode rejection ratio | 100 dB @ 50/60Hz |
| RTD types supported | 100 Ω Platinum 385, 200 Ω Platinum 385, 500 Ω Platinum 385, 1000 Ω Platinum 385, 100 Ω Platinum 392, 200 Ω Platinum 392, 500 Ω Platinum 392, 1000 Ω Platinum 392, 10 Ω Copper 427, 120 Ω Nickel 672, 604 Ω Nickel-Iron 518 |
| Surrounding air temperature, max | 65 °C |
|---|---|
| North American temperature code | T4 |
| Power consumption | 40mA @ 3.3V |
| Emissions | CISPR 11 (IEC 61000-6-4): Class A |
| ESD immunity | IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges |
| EFT/B immunity | IEC 61000-4-4: ±2kV @ 5kHz on shielded ports |
| Conducted RF immunity | IEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz |
| Surge transient immunity | IEC 61000-4-5: ±2 kV line-earth(CM) on shielded ports |
| Operating temperature | -20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock) |
| Radiated RF immunity | IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz, |
| Nonoperating temperature | -40...85 °C (-40...185 °F), IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) |
| Vibration | IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz |
|---|---|
| Shock | IEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating |
| Mounting torque | 0.2 nm |
| Terminal screw torque | 0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver) |
| Input impedance | >5 MΩ |
|---|
| Explosion safety category for gas | None |
|---|---|
| Explosion safety category for dust | None |
图纸
| 图纸 | |
|---|---|
| 3D STP (STEP) Model | Download (ZIP) |
| Product Drawing | Drawing (DXF) |
| 图纸 |
|---|
| 3D STP (STEP) Model Download (ZIP) |
| Product Drawing Drawing (DXF) |
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
|
Brochure
General
-- |
|
Wiring Diagram
General
-- |
|
Product Cutsheet
General
-- |
|
Installation Guide
General
-- |
|
2080-um004_-en-e
User Manual
2080-UM004 |
|
Micro800 Plug-in Modules User Manual
User Manual
2080-UM002 |
| 类型 | 资源 | 出版 |
|---|---|---|
| General | Brochure | -- |
| General | Wiring Diagram | -- |
| General | Product Cutsheet | -- |
| General | Installation Guide | -- |
| User Manual | 2080-um004_-en-e | 2080-UM004 |
| User Manual | Micro800 Plug-in Modules User Manual | 2080-UM002 |
认证
- Korean Register of Shippin
This product was certified with the above certifications as of 2025-09-09. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
技术说明
Loading
Copyright ©2025 Rockwell Automation, Inc.