| Consist Of | Screws |
|---|---|
| I/O Status Indication | None |
| Number of analogue inputs | 4 |
|---|---|
| Resolution of the analogue inputs | 12 bit |
| Input, current | True |
| Input, voltage | True |
| Input, resistor | False |
| Input, resistance thermometer | False |
| Input, thermocouple | False |
| Input signal, configurable | False |
| Output, current | False |
| Output, voltage | False |
| Output signal configurable | False |
| Analogue inputs configurable | True |
| Analogue outputs configurable | False |
| Type of electric connection | Screw connection |
| Data range | 0 to 65535 |
| Channel to channel isolation | Non-isolation |
| Update time | 180 ms per enabled channel |
| Input group to bus isolation | No isolation |
| Module error | Voltage: ±1.5% @ over full temperature range, -20...65°C (-4...149°F), Current: ±2.0% @ over full temperature range, -20...65°C (-4...149°F) |
| Wire size | Solid: 0.14 mm2 AWG)...1.5 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum, Stranded: 0.14 mm2 AWG)...1.0 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum |
| Suitable for safety functions | False |
| SIL according to IEC 61508 | None |
| Recommended maximum shielded cable length | 10 m |
| Voltage ranges | 0 |
| Current range | 0 mA |
| Field input calibration | Not required |
| Overall accuracy | Voltage terminal: ±1% full scale @ 25°C, Current terminal: ±1% full scale @ 25°C |
| Surrounding air temperature, max | 65 °C |
|---|---|
| North American temperature code | T4 |
| Power consumption | <60mA @ 3.3V |
| Emissions | CISPR 11 (IEC 61000-6-4): Class A |
| ESD immunity | IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges |
| EFT/B immunity | IEC 61000-4-4: ±2kV @ 5kHz on shielded ports |
| Relative humidity | IEC 60068-2-30 (Test Db, unpackaged dA heat), 5...95% noncondensing |
| Conducted RF immunity | IEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz |
| Surge transient immunity | IEC 61000-4-5: ±2 kV line-earth(CM) on shielded ports |
| Operating temperature | -20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock) |
| Radiated RF immunity | IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz, |
| Operating altitude | 2000 m |
| Nonoperating temperature | -40...85 °C (-40...185 °F), IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) |
| Non-linearity | ±0.1% @ in % full scale |
|---|
| Repeatability | ±0.1% |
|---|
| Vibration | IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz |
|---|---|
| Shock | IEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating |
| Mounting torque | 0.2 nm |
| Terminal screw torque | 0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver) |
| Input impedance | >100 kΩ for voltage mode, 250 Ω for current mode |
|---|
| Explosion safety category for gas | None |
|---|---|
| Explosion safety category for dust | None |
| 图纸 | |
|---|---|
| 3D STP (STEP) Model | Download (ZIP) |
| Product Drawing | Drawing (DXF) |
| 图纸 |
|---|
| 3D STP (STEP) Model Download (ZIP) |
| Product Drawing Drawing (DXF) |
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
| 类型 | 资源 | 出版 |
|---|---|---|
| General | Product Cutsheet | -- |
| General | Wiring Diagram | -- |
| General | Installation Guide | -- |
| General | Brochure | -- |
| User Manual | 2080-um004_-en-e | 2080-UM004 |
| User Manual | Micro800 Plug-in Modules User Manual | 2080-UM002 |
- Korean Register of Shippin
- Bureau Veritas
This product was certified with the above certifications as of 2025-10-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
技术规格
| Consist Of | Screws |
|---|---|
| I/O Status Indication | None |
| Number of analogue inputs | 4 |
|---|---|
| Resolution of the analogue inputs | 12 bit |
| Input, current | True |
| Input, voltage | True |
| Input, resistor | False |
| Input, resistance thermometer | False |
| Input, thermocouple | False |
| Input signal, configurable | False |
| Output, current | False |
| Output, voltage | False |
| Output signal configurable | False |
| Analogue inputs configurable | True |
| Analogue outputs configurable | False |
| Type of electric connection | Screw connection |
| Data range | 0 to 65535 |
| Channel to channel isolation | Non-isolation |
| Update time | 180 ms per enabled channel |
| Input group to bus isolation | No isolation |
| Module error | Voltage: ±1.5% @ over full temperature range, -20...65°C (-4...149°F), Current: ±2.0% @ over full temperature range, -20...65°C (-4...149°F) |
| Wire size | Solid: 0.14 mm2 AWG)...1.5 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum, Stranded: 0.14 mm2 AWG)...1.0 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum |
| Suitable for safety functions | False |
| SIL according to IEC 61508 | None |
| Recommended maximum shielded cable length | 10 m |
| Voltage ranges | 0 |
| Current range | 0 mA |
| Field input calibration | Not required |
| Overall accuracy | Voltage terminal: ±1% full scale @ 25°C, Current terminal: ±1% full scale @ 25°C |
| Surrounding air temperature, max | 65 °C |
|---|---|
| North American temperature code | T4 |
| Power consumption | <60mA @ 3.3V |
| Emissions | CISPR 11 (IEC 61000-6-4): Class A |
| ESD immunity | IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges |
| EFT/B immunity | IEC 61000-4-4: ±2kV @ 5kHz on shielded ports |
| Relative humidity | IEC 60068-2-30 (Test Db, unpackaged dA heat), 5...95% noncondensing |
| Conducted RF immunity | IEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz |
| Surge transient immunity | IEC 61000-4-5: ±2 kV line-earth(CM) on shielded ports |
| Operating temperature | -20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock) |
| Radiated RF immunity | IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz, |
| Operating altitude | 2000 m |
| Nonoperating temperature | -40...85 °C (-40...185 °F), IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) |
| Non-linearity | ±0.1% @ in % full scale |
|---|
| Repeatability | ±0.1% |
|---|
| Vibration | IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz |
|---|---|
| Shock | IEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating |
| Mounting torque | 0.2 nm |
| Terminal screw torque | 0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver) |
| Input impedance | >100 kΩ for voltage mode, 250 Ω for current mode |
|---|
| Explosion safety category for gas | None |
|---|---|
| Explosion safety category for dust | None |
图纸
| 图纸 | |
|---|---|
| 3D STP (STEP) Model | Download (ZIP) |
| Product Drawing | Drawing (DXF) |
| 图纸 |
|---|
| 3D STP (STEP) Model Download (ZIP) |
| Product Drawing Drawing (DXF) |
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
|
Product Cutsheet
General
-- |
|
Wiring Diagram
General
-- |
|
Installation Guide
General
-- |
|
Brochure
General
-- |
|
2080-um004_-en-e
User Manual
2080-UM004 |
|
Micro800 Plug-in Modules User Manual
User Manual
2080-UM002 |
| 类型 | 资源 | 出版 |
|---|---|---|
| General | Product Cutsheet | -- |
| General | Wiring Diagram | -- |
| General | Installation Guide | -- |
| General | Brochure | -- |
| User Manual | 2080-um004_-en-e | 2080-UM004 |
| User Manual | Micro800 Plug-in Modules User Manual | 2080-UM002 |
认证
- Korean Register of Shippin
- Bureau Veritas
This product was certified with the above certifications as of 2025-10-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
技术说明
Loading
Copyright ©2025 Rockwell Automation, Inc.