| Network |
Ethernet
|
|---|---|
| Port |
10
|
| Width |
15.3 cm
|
|---|---|
| Height |
14.8 cm
|
| Depth |
11.75 cm
|
| Screw torque, power and alarm terminals |
0.23 nm
|
| Layer 2 |
No
|
|---|---|
| Layer 3 |
Yes
|
| Manageable |
Yes
|
| Power dissipation |
15.7 W
|
| Power consumption, maximum (expansion module power not included) |
15.7 W
|
| Total number of ports |
10
|
| Wire size, ethernet connection |
RJ45 connector according to IEC 60603-7, 2 or 4-pair category 5e minimum cable according to TIA 568-B.1 or category 5 cable according to ISO/IEC 24702
|
| Ethernet |
Yes
|
| Protection type—Electronic S (short time trip units) |
Panel mount
|
| Alarm relay, CL 2/SELV at 30 V DC, maximum |
1 A
|
| Inrush current, maximum |
2 A
|
| Isolation voltage (continuous), basic insulation type, power to ground, power to network channels, and power to alarm |
75 V
|
| Maximum insulation, DC power and alarm connections |
1.2 mm
|
| Oscillatory surge withstand IEEE C37.90.1 |
2.5 kV
|
| Switch input, CL 2/SELV at 18 - 60 V DC, maximum |
2 A
|
| Wire size, DC power and alarm connections, solid or stranded copper wire rated at 90 °C or greater |
0.5 mm²
|
| Wire size, ground connection, solid or stranded copper wire rated at 75 °C or greater |
3.3 mm²
|
| Wiring category on alarm ports |
2
|
| Wiring category on Ethernet ports |
2
|
| Wiring category on power ports |
2
|
| Degree of protection (IP) |
IP20
|
|---|---|
| Housing base material |
Open-style
|
| Nominal position |
T4
|
| Temperature, surrounding air, maximum |
60 °C
|
| EFT/B immunity for IEC 61000-4-4 at 5 kHz on alarm ports |
±2
|
| EFT/B immunity for IEC 61000-4-4 at 5 kHz on Ethernet ports |
±2
|
| Emissions, CISPR11 (IEC 61000-6-4) |
Class A
|
| ESD immunity, IEC 61000-4-2, air discharges |
15 kV
|
| ESD immunity, IEC 61000-4-2, contact discharges |
8 kV
|
| Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 1000 - 2700 MHz |
10 kg/km
|
| Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz |
10 kg/km
|
| Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock) |
30 g
|
| Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock) |
20 g
|
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on Ethernet ports |
±2
|
| Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold) |
-40 °C
|
| Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock) |
-40 °C
|
| Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat) |
-40 °C
|
| Selectable start times |
T4
|
| Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms) |
10 V
|
| EFT/B immunity for IEC 61000-4-4 at 2.5 kHz on alarm ports |
±4
|
| EFT/B immunity for IEC 61000-4-4 at 2.5 kHz on Ethernet ports |
±4
|
| EFT/B immunity for IEC 61000-4-4 at 2.5 kHz on power ports |
±4
|
| EFT/B immunity for IEC 61000-4-4 at 5 kHz on power ports |
±2
|
| Magnetic field immunity, IEC 61000-4-8, long duration at 50 and 60 Hz (A/m) |
30
|
| Magnetic field immunity, IEC 61000-4-8, short duration at 50 and 60 Hz (A/m) |
300
|
| Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 1000 MHz |
20 kg/km
|
| Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz |
10 kg/km
|
| Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing |
5 %
|
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on alarm ports |
±2
|
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on power ports |
±2
|
| Surge transient immunity, IEC 61000-4-5, line-line (DM) on alarm ports |
±1
|
| Surge transient immunity, IEC 61000-4-5, line-line (DM) on power ports |
±1
|
| Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold) |
-40 °C
|
| Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock) |
-40 °C
|
| Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat) |
-40 °C
|
| Vibration, IEC 60068-2-6 (test Fc, operating) at 10 - 500 Hz |
2 g
|
| Voltage variation IEC 61000-4-29, interruption on DC supply ports |
10 ms
|
| 类型 | 资源 | 出版 |
|---|---|---|
| Application Techniques | APPLICATION_TECHNIQUES_enet-at007_-en-p | ENET-AT007 |
| Application Techniques | APPLICATION_TECHNIQUES_enet-at006_-en-p | ENET-AT006 |
| Installation Instructions | 1783-in016_-en-p | 1783-IN016 |
| Reference Manual | REFERENCE_MANUAL_enet-rm002_-en-p | ENET-RM002 |
| Technical Data | 1783-td001_-en-p | 1783-TD001 |
| User Manual | 1783-um003_-en-p | 1783-UM003 |
| User Manual | USER_MANUAL_1783-um007_-en-p | 1783-UM007 |
| 个人资料 | PROFILE_migrat-pp043_-en-p | MIGRAT-PP043 |
提供下载
- AOP for Stratix 5400/5410/5700/8000/8300/2500 Switches v14.01.05
- AOP for Stratix 5400/5410/5700/8000/8300/2500 Switches v15.01.07
- AOP for Stratix 5400/5410/5700/8000/8300/2500 Switches v15.03.02
- AOP for Stratix 5700, 8000, 8300, 5400, 5410, 2500 v17.01.05
- EDS files for 1783-RMS10T (multi)
- EDS files for Stratix Family (multi)
- AOP - Add On Profiles for 1783 and all Stratix v22.01.01
- Firmware for 1783-RMS10T, V 12.2(55)SE
- MOROCCO DOC
This product was certified with the above certifications as of 2025-09-08. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
技术规格
| Network |
Ethernet
|
|---|---|
| Port |
10
|
| Width |
15.3 cm
|
|---|---|
| Height |
14.8 cm
|
| Depth |
11.75 cm
|
| Screw torque, power and alarm terminals |
0.23 nm
|
| Layer 2 |
No
|
|---|---|
| Layer 3 |
Yes
|
| Manageable |
Yes
|
| Power dissipation |
15.7 W
|
| Power consumption, maximum (expansion module power not included) |
15.7 W
|
| Total number of ports |
10
|
| Wire size, ethernet connection |
RJ45 connector according to IEC 60603-7, 2 or 4-pair category 5e minimum cable according to TIA 568-B.1 or category 5 cable according to ISO/IEC 24702
|
| Ethernet |
Yes
|
| Protection type—Electronic S (short time trip units) |
Panel mount
|
| Alarm relay, CL 2/SELV at 30 V DC, maximum |
1 A
|
| Inrush current, maximum |
2 A
|
| Isolation voltage (continuous), basic insulation type, power to ground, power to network channels, and power to alarm |
75 V
|
| Maximum insulation, DC power and alarm connections |
1.2 mm
|
| Oscillatory surge withstand IEEE C37.90.1 |
2.5 kV
|
| Switch input, CL 2/SELV at 18 - 60 V DC, maximum |
2 A
|
| Wire size, DC power and alarm connections, solid or stranded copper wire rated at 90 °C or greater |
0.5 mm²
|
| Wire size, ground connection, solid or stranded copper wire rated at 75 °C or greater |
3.3 mm²
|
| Wiring category on alarm ports |
2
|
| Wiring category on Ethernet ports |
2
|
| Wiring category on power ports |
2
|
| Degree of protection (IP) |
IP20
|
|---|---|
| Housing base material |
Open-style
|
| Nominal position |
T4
|
| Temperature, surrounding air, maximum |
60 °C
|
| EFT/B immunity for IEC 61000-4-4 at 5 kHz on alarm ports |
±2
|
| EFT/B immunity for IEC 61000-4-4 at 5 kHz on Ethernet ports |
±2
|
| Emissions, CISPR11 (IEC 61000-6-4) |
Class A
|
| ESD immunity, IEC 61000-4-2, air discharges |
15 kV
|
| ESD immunity, IEC 61000-4-2, contact discharges |
8 kV
|
| Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 1000 - 2700 MHz |
10 kg/km
|
| Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz |
10 kg/km
|
| Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock) |
30 g
|
| Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock) |
20 g
|
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on Ethernet ports |
±2
|
| Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold) |
-40 °C
|
| Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock) |
-40 °C
|
| Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat) |
-40 °C
|
| Selectable start times |
T4
|
| Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms) |
10 V
|
| EFT/B immunity for IEC 61000-4-4 at 2.5 kHz on alarm ports |
±4
|
| EFT/B immunity for IEC 61000-4-4 at 2.5 kHz on Ethernet ports |
±4
|
| EFT/B immunity for IEC 61000-4-4 at 2.5 kHz on power ports |
±4
|
| EFT/B immunity for IEC 61000-4-4 at 5 kHz on power ports |
±2
|
| Magnetic field immunity, IEC 61000-4-8, long duration at 50 and 60 Hz (A/m) |
30
|
| Magnetic field immunity, IEC 61000-4-8, short duration at 50 and 60 Hz (A/m) |
300
|
| Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 1000 MHz |
20 kg/km
|
| Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz |
10 kg/km
|
| Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing |
5 %
|
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on alarm ports |
±2
|
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on power ports |
±2
|
| Surge transient immunity, IEC 61000-4-5, line-line (DM) on alarm ports |
±1
|
| Surge transient immunity, IEC 61000-4-5, line-line (DM) on power ports |
±1
|
| Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold) |
-40 °C
|
| Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock) |
-40 °C
|
| Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat) |
-40 °C
|
| Vibration, IEC 60068-2-6 (test Fc, operating) at 10 - 500 Hz |
2 g
|
| Voltage variation IEC 61000-4-29, interruption on DC supply ports |
10 ms
|
文档
|
APPLICATION_TECHNIQUES_enet-at007_-en-p
Application Techniques
ENET-AT007 |
|
APPLICATION_TECHNIQUES_enet-at006_-en-p
Application Techniques
ENET-AT006 |
|
1783-in016_-en-p
Installation Instructions
1783-IN016 |
|
REFERENCE_MANUAL_enet-rm002_-en-p
Reference Manual
ENET-RM002 |
|
1783-td001_-en-p
Technical Data
1783-TD001 |
|
1783-um003_-en-p
User Manual
1783-UM003 |
|
USER_MANUAL_1783-um007_-en-p
User Manual
1783-UM007 |
|
PROFILE_migrat-pp043_-en-p
个人资料
MIGRAT-PP043 |
| 类型 | 资源 | 出版 |
|---|---|---|
| Application Techniques | APPLICATION_TECHNIQUES_enet-at007_-en-p | ENET-AT007 |
| Application Techniques | APPLICATION_TECHNIQUES_enet-at006_-en-p | ENET-AT006 |
| Installation Instructions | 1783-in016_-en-p | 1783-IN016 |
| Reference Manual | REFERENCE_MANUAL_enet-rm002_-en-p | ENET-RM002 |
| Technical Data | 1783-td001_-en-p | 1783-TD001 |
| User Manual | 1783-um003_-en-p | 1783-UM003 |
| User Manual | USER_MANUAL_1783-um007_-en-p | 1783-UM007 |
| 个人资料 | PROFILE_migrat-pp043_-en-p | MIGRAT-PP043 |
下载
提供下载
- AOP for Stratix 5400/5410/5700/8000/8300/2500 Switches v14.01.05
- AOP for Stratix 5400/5410/5700/8000/8300/2500 Switches v15.01.07
- AOP for Stratix 5400/5410/5700/8000/8300/2500 Switches v15.03.02
- AOP for Stratix 5700, 8000, 8300, 5400, 5410, 2500 v17.01.05
- EDS files for 1783-RMS10T (multi)
- EDS files for Stratix Family (multi)
- AOP - Add On Profiles for 1783 and all Stratix v22.01.01
- Firmware for 1783-RMS10T, V 12.2(55)SE
认证
- MOROCCO DOC
This product was certified with the above certifications as of 2025-09-08. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
替代产品
技术说明
Loading
Copyright ©2025 Rockwell Automation, Inc.