Loading
Allen-Bradley 1783-LMS8 product image
Allen Bradley
畅销产品
1783-LMS8

Stratix2500 8Port Lightly Managed Switch

PrintPrint
打印
EmailEmail
共享
Product RegistrationProduct Registration
QR code
Allen-Bradley 1783-LMS8 product image
Allen Bradley
生命周期状态: 活跃
Product at a glance
Product Registration
生命周期状态: 活跃
Product at a glance
Product Registration
添加到BoM
  • 注册产品
  • 寻找支持
Technical Specifications
Drawings
Documents
Certifications
Accessories
Alternative Products
Technotes
Network Media
Male RJ45 to Male RJ45 Patchcord, Unshielded Twisted Pair, Teal TPE Cable, 1.9 m
# of Copper Ports Required
8 or less
# of Fiber Ports Required
None
Stratix Ethernet Family
Stratix 2500
Width
45.7 cm
Height
144.8 cm
Depth
115 cm
Torque, functional ground lug screw
0.51 nm
Torque, power terminal screw
0.19 nm
Number of ports 10/100 Mbps RJ45
8
Layer 2
False
Layer 3
False
Manageable
True
Pulse (digital) output
5.3 W
Power dissipation
5.3 W
Power Input
12 - 24V DC, 0.4 - 0.2 A (SELV)
Total number of ports
8
Wire size, ethernet connection
RJ45 connector according to IEC 60603-7, 2 or 4-pair category 5e minimum cable according to TIA 568-B.1 or category 5 cable according to ISO/IEC 24702
Ethernet
True
Wire size, DC power connection, solid or stranded copper wire rated at 30 °C, or greater, above the surrounding air temperature
0.82 mm²
Wire size, ground connection, solid or stranded copper wire
3.3 mm²
Wiring category on communication ports
2
Wiring category on power ports
2
Degree of protection (IP)
IP30
Housing base material
Open-style
Nominal position
T4
Delta connected motor power, max
T4
Temperature, surrounding air, maximum
60 °C
EFT/B immunity for IEC 61000-4-4 at 100 kHz on DC power ports
±3
EFT/B immunity for IEC 61000-4-4 at 100 kHz on Ethernet ports
±3
Emissions, CISPR11 (IEC 61000-6-4)
IEC 61000-6-4
ESD immunity, IEC 61000-4-2, air discharges
8 kV
ESD immunity, IEC 61000-4-2, contact discharges
6 kV
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 2000 - 2700 MHz
3 kg/km
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 2000 MHz
10 kg/km
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz
10 kg/km
Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock)
30 g
Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock)
30 g
Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold)
-20 °C
Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock)
-20 °C
Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat)
-20 °C
Ambient temperature, maximum
60 °C
Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms)
10 V
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz
10 kg/km
Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing
5 %
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on communication ports
±2
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on DC power ports
±2
Surge transient immunity, IEC 61000-4-5, line-line (DM) on DC power ports
±1
Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold)
-40 °C
Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock)
-40 °C
Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat)
-40 °C
图纸
2-Dimensional Drawing (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
图纸
2-Dimensional Drawing (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
类型 资源 出版
Application Techniques APPLICATION_TECHNIQUES_enet-at007_-en-p ENET-AT007
Application Techniques APPLICATION_TECHNIQUES_enet-at006_-en-p ENET-AT006
General Product Cutsheet --
General Product Registration Link --
Installation Instructions 1783-in016_-en-p 1783-IN016
Profile PROFILE_migrat-pp043_-en-p MIGRAT-PP043
Reference Manual REFERENCE_MANUAL_enet-rm002_-en-p ENET-RM002
User Manual 1783-um009_-en-p 1783-UM009
User Manual USER_MANUAL_1783-um007_-en-p 1783-UM007
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
访问技术文档中心 搜索文献资料库
China CCC UL Listed UKCA DOC
  • Semiconductor Inds Immunit
  • China CCC
  • UL Listed
  • UL Listed Hazardous
  • UKCA DOC
  • MOROCCO DOC
  • UK EX CERTIFICATE

This product was certified with the above certifications as of 2025-11-03. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

每页项目:
1-1 关于 1
每页项目:
1-1 关于 1
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
技术规格
Network Media
Male RJ45 to Male RJ45 Patchcord, Unshielded Twisted Pair, Teal TPE Cable, 1.9 m
# of Copper Ports Required
8 or less
# of Fiber Ports Required
None
Stratix Ethernet Family
Stratix 2500
Width
45.7 cm
Height
144.8 cm
Depth
115 cm
Torque, functional ground lug screw
0.51 nm
Torque, power terminal screw
0.19 nm
Number of ports 10/100 Mbps RJ45
8
Layer 2
False
Layer 3
False
Manageable
True
Pulse (digital) output
5.3 W
Power dissipation
5.3 W
Power Input
12 - 24V DC, 0.4 - 0.2 A (SELV)
Total number of ports
8
Wire size, ethernet connection
RJ45 connector according to IEC 60603-7, 2 or 4-pair category 5e minimum cable according to TIA 568-B.1 or category 5 cable according to ISO/IEC 24702
Ethernet
True
Wire size, DC power connection, solid or stranded copper wire rated at 30 °C, or greater, above the surrounding air temperature
0.82 mm²
Wire size, ground connection, solid or stranded copper wire
3.3 mm²
Wiring category on communication ports
2
Wiring category on power ports
2
Degree of protection (IP)
IP30
Housing base material
Open-style
Nominal position
T4
Delta connected motor power, max
T4
Temperature, surrounding air, maximum
60 °C
EFT/B immunity for IEC 61000-4-4 at 100 kHz on DC power ports
±3
EFT/B immunity for IEC 61000-4-4 at 100 kHz on Ethernet ports
±3
Emissions, CISPR11 (IEC 61000-6-4)
IEC 61000-6-4
ESD immunity, IEC 61000-4-2, air discharges
8 kV
ESD immunity, IEC 61000-4-2, contact discharges
6 kV
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 2000 - 2700 MHz
3 kg/km
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 2000 MHz
10 kg/km
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz
10 kg/km
Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock)
30 g
Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock)
30 g
Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold)
-20 °C
Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock)
-20 °C
Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat)
-20 °C
Ambient temperature, maximum
60 °C
Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms)
10 V
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz
10 kg/km
Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing
5 %
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on communication ports
±2
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on DC power ports
±2
Surge transient immunity, IEC 61000-4-5, line-line (DM) on DC power ports
±1
Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold)
-40 °C
Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock)
-40 °C
Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat)
-40 °C
图纸
图纸
2-Dimensional Drawing (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
图纸
2-Dimensional Drawing (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
文档
APPLICATION_TECHNIQUES_enet-at007_-en-p Application Techniques
ENET-AT007
APPLICATION_TECHNIQUES_enet-at006_-en-p Application Techniques
ENET-AT006
Product Cutsheet General
--
Product Registration Link General
--
1783-in016_-en-p Installation Instructions
1783-IN016
PROFILE_migrat-pp043_-en-p Profile
MIGRAT-PP043
REFERENCE_MANUAL_enet-rm002_-en-p Reference Manual
ENET-RM002
1783-um009_-en-p User Manual
1783-UM009
USER_MANUAL_1783-um007_-en-p User Manual
1783-UM007
类型 资源 出版
Application Techniques APPLICATION_TECHNIQUES_enet-at007_-en-p ENET-AT007
Application Techniques APPLICATION_TECHNIQUES_enet-at006_-en-p ENET-AT006
General Product Cutsheet --
General Product Registration Link --
Installation Instructions 1783-in016_-en-p 1783-IN016
Profile PROFILE_migrat-pp043_-en-p MIGRAT-PP043
Reference Manual REFERENCE_MANUAL_enet-rm002_-en-p ENET-RM002
User Manual 1783-um009_-en-p 1783-UM009
User Manual USER_MANUAL_1783-um007_-en-p 1783-UM007
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
访问技术文档中心 搜索文献资料库
认证
China CCC UL Listed UKCA DOC
  • Semiconductor Inds Immunit
  • China CCC
  • UL Listed
  • UL Listed Hazardous
  • UKCA DOC
  • MOROCCO DOC
  • UK EX CERTIFICATE

This product was certified with the above certifications as of 2025-11-03. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

配件
每页项目:
1-1 关于 1
替代产品
每页项目:
1-1 关于 1
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
Loading
寻找最近经销商
更改位置
EmailEmail
PhonePhone
寻找合作伙伴
Stratix2500 8Port Lightly Managed Switch
CloseClose
1783-LMS8
关闭
打印
Allen-Bradley 1783-LMS8 product image
电话:
呼叫
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页
  2. Chevron LeftChevron Left 产品
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose