生命周期状态:
停止
Rockwell Automation announces that as of January 30, 2025, the Stratix 5400 12 Port Managed Switch will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停售日期:
January 30, 2025
替代类别:
Engineering Replacement
产品概览
产品注册
Description
Stratix 5400,8个10/100/1000铜质端口,4个10/100/1000组合端口,二层FW
1783-HMS8TG4CGN
Stratix 5400 12 Port Managed Switch
Serial #:
此产品尚未验证,请{}确认真实性
注册您的产品
生命周期状态:
停止
Rockwell Automation announces that as of January 30, 2025, the Stratix 5400 12 Port Managed Switch will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停售日期:
January 30, 2025
替代类别:
Engineering Replacement
产品概览
产品注册
Description
Stratix 5400,8个10/100/1000铜质端口,4个10/100/1000组合端口,二层FW
概述
Electrical & Connectivity
General Features
Power & Electrical Characteristics
Physical Characteristics
Mechanical
Compliance & Environment
Standards & Protection
图纸
文档
下载
认证
配件
替代产品
技术说明
| 唯一产品序列号 |
1783-HMS8TG4CGN
|
|---|---|
| 通用产品代码(UPC) |
887172556487
|
| 标准保修期 |
1年 查看详情 |
| 原产国 |
多个
|
| Conformal coating |
False
|
|---|---|
| NAT |
True
|
| Network |
Ethernet
|
| Port |
12
|
| SW Type |
Layer 2
|
| Alarm relay at 30V DC |
1 A
|
|---|---|
| Alarm relay at 48V DC |
0.5 A
|
| CIP sync (IEEE 1588) |
True
|
| DLR |
True
|
| Ethernet |
True
|
| Isolation voltage (continuous), basic insulation type, all ports to ground |
60 V
|
| Layer 2 |
True
|
| Layer 3 |
False
|
| Manageable |
True
|
| Mounting method |
DIN rail (top hat rail)
|
| NAT |
True
|
| Number of combination ports 10/100/1000 Mbps |
4
|
| Number of combination-ports RJ45/Mini GBIC |
4
|
| Number of ports 10/100/1000 Mbps RJ45 |
8
|
| Power consumption at 24V DC, 40 ˚C |
35 W
|
| Power dissipation |
35 W
|
| Power input at 12 - 54V DC, maximum |
3.7 A
|
| Protection type |
Alarm not rated
|
| Total number of ports |
12
|
| Wire size, DC power connection, solid or stranded copper wire rated at 30 ˚C, or greater, above the surrounding air temperature |
0.52 mm²
|
| Wire size, alarm connection, solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire |
0.5 mm²
|
| Wire size, ground connection, solid or stranded copper wire |
4 mm²
|
| Wire strip length, DC power connection |
6.3±0.5
|
| Wire strip length, alarm connection |
6.3±0.5
|
| Wiring category on DC power and alarm ports |
2
|
| Wiring category on Ethernet ports |
2
|
| Wiring category on console ports |
3
|
Mechanical
| Approximate weight |
2.88 kg
|
|---|---|
| Depth |
14.67 cm
|
| Height |
16.45 cm
|
| Screw torque, alarm terminal |
0.23 nm
|
| Screw torque, ground terminal |
0.51 nm
|
| Screw torque, power terminal |
0.56 nm
|
| Width |
15.54 cm
|
| Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms) |
10 V
|
|---|---|
| Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on Ethernet ports |
±2.5
|
| Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on power and alarm ports |
±2.5
|
| Damped oscillatory wave immunity, IEC 61000-4-18, line-line (DM) on power and alarm ports |
±1
|
| Delta connected motor power, max |
T3
|
| EFT/B immunity for IEC 61000-4-4 at 5 - 100 kHz on DC power ports |
±3
|
| EFT/B immunity for IEC 61000-4-4 at 5 - 100 kHz on Ethernet ports |
±3
|
| EFT/B immunity for IEC 61000-4-4 at 5 - 100 kHz on alarm ports |
±3
|
| ESD immunity, IEC 61000-4-2, air discharges |
8 kV
|
| ESD immunity, IEC 61000-4-2, contact discharges |
6 kV
|
| Emissions |
IEC 61000-6-4
|
| Housing base material |
Open-style
|
| Magnetic field immunity, IEC 61000-4-8, long duration at 50 - 60 Hz (A/m) |
300
|
| Magnetic field immunity, IEC 61000-4-8, short duration at 50 - 60 Hz (A/m) |
1000
|
| Magnetic pulse immunity, IEC 61000-4-9 (A/m) |
300
|
| Nominal position |
T3
|
| Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 2000 - 2700 MHz |
20 kg/km
|
| Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 2000 MHz |
20 kg/km
|
| Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz |
10 kg/km
|
| Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz |
10 kg/km
|
| Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing |
5 %
|
| Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock) |
30 g
|
| Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock) |
15 g
|
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on DC power ports |
±2
|
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on Ethernet ports |
±2
|
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on alarm ports |
±2
|
| Surge transient immunity, IEC 61000-4-5, line-line (DM) on DC power ports |
±1
|
| Surge transient immunity, IEC 61000-4-5, line-line (DM) on alarm ports |
±1
|
| Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold) |
-40 °C
|
| Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock) |
-40 °C
|
| Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat) |
-40 °C
|
| Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold) |
-40 °C
|
| Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock) |
-40 °C
|
| Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat) |
-40 °C
|
| Temperature, surrounding air, maximum |
70 °C
|
| Vibration, IEC 60068-2-6 (test Fc, operating) at 5 - 150 Hz |
1 g
|
| Voltage variation, IEC 61000-4-29, interruption on DC power ports |
10 ms
|
| 参考手册 | 出版 |
|---|---|
| REFERENCE_MANUAL_enet-rm002_-en-p | ENET-RM002 |
| 基本信息 | 出版 |
|---|---|
| Product Cutsheet | -- |
| Product Registration Link | -- |
| 安装说明 | 出版 |
|---|---|
| 1783-in016_-en-p | 1783-IN016 |
| 应用技巧 | 出版 |
|---|---|
| APPLICATION_TECHNIQUES_enet-at007_-en-p | ENET-AT007 |
| APPLICATION_TECHNIQUES_enet-at006_-en-p | ENET-AT006 |
| 技术数据 | 出版 |
|---|---|
| 1783-td002_-en-p | 1783-TD002 |
| 用户手册 | 出版 |
|---|---|
| USER_MANUAL_1783-um007_-en-p | 1783-UM007 |
| 配置文件 | 出版 |
|---|---|
| PROFILE_migrat-pp043_-en-p | MIGRAT-PP043 |
版本:
发布说明
CVE-2018-0466, CVE-2018-0473, CVE-2018-15373, CVE-2018-0470, CVE-2018-0467
Product Security Advisory
-
CVE-2018-0466, CVE-2018-0473, CVE-2018-15373, CVE-2018-0470, CVE-2018-0467
Product Security Advisory
-
CVE-2018-0466, CVE-2018-0473, CVE-2018-15373, CVE-2018-0470, CVE-2018-0467
Product Security Advisory
-
CVE-2018-0466, CVE-2018-0473, CVE-2018-15373, CVE-2018-0470, CVE-2018-0467
Product Security Advisory
-
CVE-2018-0466, CVE-2018-0473, CVE-2018-15373, CVE-2018-0470, CVE-2018-0467
Product Security Advisory
-
AOP for Stratix 5400, 5410, 8000, 8300, Armor and Stratix 5700 v13.03.06
AOP - Add On Profiles
433 MB
发布说明
- China CCC
- UL Listed Hazardous
截至 2026-08-11,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。
正在查找认证文件?
请浏览我们内容详尽的资料库,查看该产品及其他产品的认证信息。
法规信息
| 欧盟进口商地址 |
Rockwell Automation N.V |
|---|---|
| 欧盟授权代表地址 |
Rockwell Automation N.V |
每页项目:
每页项目:
| 技术说明 |
|---|
概述
| 唯一产品序列号 |
1783-HMS8TG4CGN
|
|---|---|
| 通用产品代码(UPC) |
887172556487
|
| 标准保修期 |
1年 查看详情 |
| 原产国 |
多个
|
Electrical & Connectivity
| Conformal coating |
False
|
|---|---|
| NAT |
True
|
| Network |
Ethernet
|
| Port |
12
|
| SW Type |
Layer 2
|
| Alarm relay at 30V DC |
1 A
|
|---|---|
| Alarm relay at 48V DC |
0.5 A
|
| CIP sync (IEEE 1588) |
True
|
| DLR |
True
|
| Ethernet |
True
|
| Isolation voltage (continuous), basic insulation type, all ports to ground |
60 V
|
| Layer 2 |
True
|
| Layer 3 |
False
|
| Manageable |
True
|
| Mounting method |
DIN rail (top hat rail)
|
| NAT |
True
|
| Number of combination ports 10/100/1000 Mbps |
4
|
| Number of combination-ports RJ45/Mini GBIC |
4
|
| Number of ports 10/100/1000 Mbps RJ45 |
8
|
| Power consumption at 24V DC, 40 ˚C |
35 W
|
| Power dissipation |
35 W
|
| Power input at 12 - 54V DC, maximum |
3.7 A
|
| Protection type |
Alarm not rated
|
| Total number of ports |
12
|
| Wire size, DC power connection, solid or stranded copper wire rated at 30 ˚C, or greater, above the surrounding air temperature |
0.52 mm²
|
| Wire size, alarm connection, solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire |
0.5 mm²
|
| Wire size, ground connection, solid or stranded copper wire |
4 mm²
|
| Wire strip length, DC power connection |
6.3±0.5
|
| Wire strip length, alarm connection |
6.3±0.5
|
| Wiring category on DC power and alarm ports |
2
|
| Wiring category on Ethernet ports |
2
|
| Wiring category on console ports |
3
|
Physical Characteristics
Mechanical
| Approximate weight |
2.88 kg
|
|---|---|
| Depth |
14.67 cm
|
| Height |
16.45 cm
|
| Screw torque, alarm terminal |
0.23 nm
|
| Screw torque, ground terminal |
0.51 nm
|
| Screw torque, power terminal |
0.56 nm
|
| Width |
15.54 cm
|
Compliance & Environment
| Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms) |
10 V
|
|---|---|
| Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on Ethernet ports |
±2.5
|
| Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on power and alarm ports |
±2.5
|
| Damped oscillatory wave immunity, IEC 61000-4-18, line-line (DM) on power and alarm ports |
±1
|
| Delta connected motor power, max |
T3
|
| EFT/B immunity for IEC 61000-4-4 at 5 - 100 kHz on DC power ports |
±3
|
| EFT/B immunity for IEC 61000-4-4 at 5 - 100 kHz on Ethernet ports |
±3
|
| EFT/B immunity for IEC 61000-4-4 at 5 - 100 kHz on alarm ports |
±3
|
| ESD immunity, IEC 61000-4-2, air discharges |
8 kV
|
| ESD immunity, IEC 61000-4-2, contact discharges |
6 kV
|
| Emissions |
IEC 61000-6-4
|
| Housing base material |
Open-style
|
| Magnetic field immunity, IEC 61000-4-8, long duration at 50 - 60 Hz (A/m) |
300
|
| Magnetic field immunity, IEC 61000-4-8, short duration at 50 - 60 Hz (A/m) |
1000
|
| Magnetic pulse immunity, IEC 61000-4-9 (A/m) |
300
|
| Nominal position |
T3
|
| Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 2000 - 2700 MHz |
20 kg/km
|
| Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 2000 MHz |
20 kg/km
|
| Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz |
10 kg/km
|
| Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz |
10 kg/km
|
| Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing |
5 %
|
| Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock) |
30 g
|
| Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock) |
15 g
|
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on DC power ports |
±2
|
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on Ethernet ports |
±2
|
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on alarm ports |
±2
|
| Surge transient immunity, IEC 61000-4-5, line-line (DM) on DC power ports |
±1
|
| Surge transient immunity, IEC 61000-4-5, line-line (DM) on alarm ports |
±1
|
| Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold) |
-40 °C
|
| Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock) |
-40 °C
|
| Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat) |
-40 °C
|
| Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold) |
-40 °C
|
| Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock) |
-40 °C
|
| Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat) |
-40 °C
|
| Temperature, surrounding air, maximum |
70 °C
|
| Vibration, IEC 60068-2-6 (test Fc, operating) at 5 - 150 Hz |
1 g
|
| Voltage variation, IEC 61000-4-29, interruption on DC power ports |
10 ms
|
图纸
文档
|
REFERENCE_MANUAL_enet-rm002_-en-p
参考手册
ENET-RM002 |
|
Product Cutsheet
基本信息
-- |
|
Product Registration Link
基本信息
-- |
|
1783-in016_-en-p
安装说明
1783-IN016 |
|
APPLICATION_TECHNIQUES_enet-at007_-en-p
应用技巧
ENET-AT007 |
|
APPLICATION_TECHNIQUES_enet-at006_-en-p
应用技巧
ENET-AT006 |
|
1783-td002_-en-p
技术数据
1783-TD002 |
|
USER_MANUAL_1783-um007_-en-p
用户手册
1783-UM007 |
|
PROFILE_migrat-pp043_-en-p
配置文件
MIGRAT-PP043 |
| 参考手册 | 出版 |
|---|---|
| REFERENCE_MANUAL_enet-rm002_-en-p | ENET-RM002 |
| 基本信息 | 出版 |
| Product Cutsheet | -- |
| Product Registration Link | -- |
| 安装说明 | 出版 |
| 1783-in016_-en-p | 1783-IN016 |
| 应用技巧 | 出版 |
| APPLICATION_TECHNIQUES_enet-at007_-en-p | ENET-AT007 |
| APPLICATION_TECHNIQUES_enet-at006_-en-p | ENET-AT006 |
| 技术数据 | 出版 |
| 1783-td002_-en-p | 1783-TD002 |
| 用户手册 | 出版 |
| USER_MANUAL_1783-um007_-en-p | 1783-UM007 |
| 配置文件 | 出版 |
| PROFILE_migrat-pp043_-en-p | MIGRAT-PP043 |
下载
版本:
发布说明
CVE-2018-0466, CVE-2018-0473, CVE-2018-15373, CVE-2018-0470, CVE-2018-0467
Product Security Advisory
-
CVE-2018-0466, CVE-2018-0473, CVE-2018-15373, CVE-2018-0470, CVE-2018-0467
Product Security Advisory
-
CVE-2018-0466, CVE-2018-0473, CVE-2018-15373, CVE-2018-0470, CVE-2018-0467
Product Security Advisory
-
CVE-2018-0466, CVE-2018-0473, CVE-2018-15373, CVE-2018-0470, CVE-2018-0467
Product Security Advisory
-
CVE-2018-0466, CVE-2018-0473, CVE-2018-15373, CVE-2018-0470, CVE-2018-0467
Product Security Advisory
-
AOP for Stratix 5400, 5410, 8000, 8300, Armor and Stratix 5700 v13.03.06
AOP - Add On Profiles
433 MB
发布说明
认证
- China CCC
- UL Listed Hazardous
截至 2026-08-11,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。
正在查找认证文件?
请浏览我们内容详尽的资料库,查看该产品及其他产品的认证信息。
法规信息
| 欧盟进口商地址 |
Rockwell Automation N.V |
|---|---|
| 欧盟授权代表地址 |
Rockwell Automation N.V |
配件
每页项目:
替代产品
每页项目:
技术说明
| 技术说明 |
|---|
基于制造地点的多个原产国