Loading
  • alt text
alt text
1783-HMS16TG4CGR

Stratix 5400 20 Port Managed Switch

PrintPrint
打印
EmailEmail
共享
Product RegistrationProduct Registration
二维码
Allen-Bradley 1783-HMS16TG4CGR product image
生命周期状态: 停止
ErrorsErrors
Rockwell Automation announces that as of January 30, 2025, the Stratix 5400 20 Port Managed Switch will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期: January 30, 2025 替代类别: Engineering Replacement
产品概览
提供多种维修方式
产品注册
生命周期状态: 停止
ErrorsErrors
Rockwell Automation announces that as of January 30, 2025, the Stratix 5400 20 Port Managed Switch will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期: January 30, 2025 替代类别: Engineering Replacement
产品概览
提供多种维修方式
产品注册
添加到BoM
  • 注册产品
  • 寻找支持
技术规格
基本信息
Mechanical
Electrical
Environmental
图纸
文档
认证
配件
替代产品
技术说明
CIP Sync
Yes
Combo ports
4 GE
Conformal coating
No
Copper ports
16 GE
Fiber ports
0
Network
Ethernet
SW Type
Layer 3
Width
15.54 cm
Height
16.45 cm
Depth
14.67 cm
Approximate weight
2.88 kg
Screw torque, alarm terminal
0.23 nm
Screw torque, ground terminal
0.51 nm
Screw torque, power terminal
0.56 nm
Number of ports 10/100/1000 Mbps RJ45
16
Number of combination-ports RJ45/Mini GBIC
4
Layer 2
No
Layer 3
Yes
Manageable
Yes
Power dissipation
40 W
Number of combination ports 10/100/1000 Mbps
4
Power consumption at 24V DC, 40 ˚C
40 W
Power input at 12 - 54V DC, maximum
4.3 A
Total number of ports
20
Wire size, alarm connection, solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire
0.5 mm²
Wire size, ground connection, solid or stranded copper wire
4 mm²
Mounting method
DIN rail (top hat rail)
Ethernet
Yes
Protection type
Alarm not rated
Alarm relay at 30V DC
1 A
Alarm relay at 48V DC
0.5 A
CIP sync (IEEE 1588)
Yes
DLR
Yes
Isolation voltage (continuous), basic insulation type, all ports to ground
60 V
NAT
Yes
Wire size, DC power connection, solid or stranded copper wire rated at 30 ˚C, or greater, above the surrounding air temperature
0.52 mm²
Wire strip length, alarm connection
6.3±0.5
Wire strip length, DC power connection
6.3±0.5
Wiring category on console ports
3
Wiring category on DC power and alarm ports
2
Wiring category on Ethernet ports
2
Housing base material
Open-style
Nominal position
T3
Delta connected motor power, max
T3
Temperature, surrounding air, maximum
70 °C
ESD immunity, IEC 61000-4-2, air discharges
8 kV
ESD immunity, IEC 61000-4-2, contact discharges
6 kV
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 2000 - 2700 MHz
20 kg/km
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 2000 MHz
20 kg/km
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz
10 kg/km
Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock)
30 g
Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock)
15 g
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on Ethernet ports
±2
Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold)
-40 °C
Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock)
-40 °C
Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat)
-40 °C
Emissions
IEC 61000-6-4
Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms)
10 V
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on Ethernet ports
±2.5
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on power and alarm ports
±2.5
Damped oscillatory wave immunity, IEC 61000-4-18, line-line (DM) on power and alarm ports
±1
EFT/B immunity for IEC 61000-4-4 at 5 - 100 kHz on alarm ports
±3
EFT/B immunity for IEC 61000-4-4 at 5 - 100 kHz on DC power ports
±3
EFT/B immunity for IEC 61000-4-4 at 5 - 100 kHz on Ethernet ports
±3
Magnetic field immunity, IEC 61000-4-8, long duration at 50 - 60 Hz (A/m)
300
Magnetic field immunity, IEC 61000-4-8, short duration at 50 - 60 Hz (A/m)
1000
Magnetic pulse immunity, IEC 61000-4-9 (A/m)
300
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz
10 kg/km
Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing
5 %
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on alarm ports
±2
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on DC power ports
±2
Surge transient immunity, IEC 61000-4-5, line-line (DM) on alarm ports
±1
Surge transient immunity, IEC 61000-4-5, line-line (DM) on DC power ports
±1
Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold)
-40 °C
Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock)
-40 °C
Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat)
-40 °C
Vibration, IEC 60068-2-6 (test Fc, operating) at 5 - 150 Hz
1 g
Voltage variation, IEC 61000-4-29, interruption on DC power ports
10 ms
图纸
3-Dimensional STEP model (STP) 下载 (ZIP)
产品图纸 图纸 (DXF)
图纸
3-Dimensional STEP model (STP) 下载 (ZIP)
产品图纸 图纸 (DXF)
参考手册 出版
REFERENCE_MANUAL_enet-rm002_-en-p ENET-RM002
基本信息 出版
Product Registration Link --
Product Cutsheet --
安装说明 出版
1783-in016_-en-p 1783-IN016
应用技巧 出版
APPLICATION_TECHNIQUES_enet-at007_-en-p ENET-AT007
APPLICATION_TECHNIQUES_enet-at006_-en-p ENET-AT006
技术数据 出版
1783-td002_-en-p 1783-TD002
用户手册 出版
USER_MANUAL_1783-um007_-en-p 1783-UM007
配置文件 出版
PROFILE_migrat-pp043_-en-p MIGRAT-PP043
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
访问技术文档中心 搜索文献资料库
China CCC
  • China CCC
  • MOROCCO DOC

截至 2025-12-23,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。

每页项目:
1-1 关于 1
每页项目:
1-1 关于 1
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
技术规格
CIP Sync
Yes
Combo ports
4 GE
Conformal coating
No
Copper ports
16 GE
Fiber ports
0
Network
Ethernet
SW Type
Layer 3
Width
15.54 cm
Height
16.45 cm
Depth
14.67 cm
Approximate weight
2.88 kg
Screw torque, alarm terminal
0.23 nm
Screw torque, ground terminal
0.51 nm
Screw torque, power terminal
0.56 nm
Number of ports 10/100/1000 Mbps RJ45
16
Number of combination-ports RJ45/Mini GBIC
4
Layer 2
No
Layer 3
Yes
Manageable
Yes
Power dissipation
40 W
Number of combination ports 10/100/1000 Mbps
4
Power consumption at 24V DC, 40 ˚C
40 W
Power input at 12 - 54V DC, maximum
4.3 A
Total number of ports
20
Wire size, alarm connection, solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire
0.5 mm²
Wire size, ground connection, solid or stranded copper wire
4 mm²
Mounting method
DIN rail (top hat rail)
Ethernet
Yes
Protection type
Alarm not rated
Alarm relay at 30V DC
1 A
Alarm relay at 48V DC
0.5 A
CIP sync (IEEE 1588)
Yes
DLR
Yes
Isolation voltage (continuous), basic insulation type, all ports to ground
60 V
NAT
Yes
Wire size, DC power connection, solid or stranded copper wire rated at 30 ˚C, or greater, above the surrounding air temperature
0.52 mm²
Wire strip length, alarm connection
6.3±0.5
Wire strip length, DC power connection
6.3±0.5
Wiring category on console ports
3
Wiring category on DC power and alarm ports
2
Wiring category on Ethernet ports
2
Housing base material
Open-style
Nominal position
T3
Delta connected motor power, max
T3
Temperature, surrounding air, maximum
70 °C
ESD immunity, IEC 61000-4-2, air discharges
8 kV
ESD immunity, IEC 61000-4-2, contact discharges
6 kV
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 2000 - 2700 MHz
20 kg/km
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 2000 MHz
20 kg/km
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz
10 kg/km
Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock)
30 g
Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock)
15 g
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on Ethernet ports
±2
Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold)
-40 °C
Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock)
-40 °C
Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat)
-40 °C
Emissions
IEC 61000-6-4
Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms)
10 V
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on Ethernet ports
±2.5
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on power and alarm ports
±2.5
Damped oscillatory wave immunity, IEC 61000-4-18, line-line (DM) on power and alarm ports
±1
EFT/B immunity for IEC 61000-4-4 at 5 - 100 kHz on alarm ports
±3
EFT/B immunity for IEC 61000-4-4 at 5 - 100 kHz on DC power ports
±3
EFT/B immunity for IEC 61000-4-4 at 5 - 100 kHz on Ethernet ports
±3
Magnetic field immunity, IEC 61000-4-8, long duration at 50 - 60 Hz (A/m)
300
Magnetic field immunity, IEC 61000-4-8, short duration at 50 - 60 Hz (A/m)
1000
Magnetic pulse immunity, IEC 61000-4-9 (A/m)
300
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz
10 kg/km
Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing
5 %
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on alarm ports
±2
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on DC power ports
±2
Surge transient immunity, IEC 61000-4-5, line-line (DM) on alarm ports
±1
Surge transient immunity, IEC 61000-4-5, line-line (DM) on DC power ports
±1
Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold)
-40 °C
Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock)
-40 °C
Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat)
-40 °C
Vibration, IEC 60068-2-6 (test Fc, operating) at 5 - 150 Hz
1 g
Voltage variation, IEC 61000-4-29, interruption on DC power ports
10 ms
图纸
图纸
3-Dimensional STEP model (STP) 下载 (ZIP)
产品图纸 图纸 (DXF)
图纸
3-Dimensional STEP model (STP) 下载 (ZIP)
产品图纸 图纸 (DXF)
文档
REFERENCE_MANUAL_enet-rm002_-en-p 参考手册
ENET-RM002
Product Registration Link 基本信息
--
Product Cutsheet 基本信息
--
1783-in016_-en-p 安装说明
1783-IN016
APPLICATION_TECHNIQUES_enet-at007_-en-p 应用技巧
ENET-AT007
APPLICATION_TECHNIQUES_enet-at006_-en-p 应用技巧
ENET-AT006
1783-td002_-en-p 技术数据
1783-TD002
USER_MANUAL_1783-um007_-en-p 用户手册
1783-UM007
PROFILE_migrat-pp043_-en-p 配置文件
MIGRAT-PP043
参考手册 出版
REFERENCE_MANUAL_enet-rm002_-en-p ENET-RM002
基本信息 出版
Product Registration Link --
Product Cutsheet --
安装说明 出版
1783-in016_-en-p 1783-IN016
应用技巧 出版
APPLICATION_TECHNIQUES_enet-at007_-en-p ENET-AT007
APPLICATION_TECHNIQUES_enet-at006_-en-p ENET-AT006
技术数据 出版
1783-td002_-en-p 1783-TD002
用户手册 出版
USER_MANUAL_1783-um007_-en-p 1783-UM007
配置文件 出版
PROFILE_migrat-pp043_-en-p MIGRAT-PP043
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
访问技术文档中心 搜索文献资料库
认证
China CCC
  • China CCC
  • MOROCCO DOC

截至 2025-12-23,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。

配件
每页项目:
1-1 关于 1
替代产品
每页项目:
1-1 关于 1
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
Loading
寻找最近经销商
请联系您在{0}的经销商
更改位置
EmailEmail
PhonePhone
寻找合作伙伴
Stratix 5400 20 Port Managed Switch
CloseClose
1783-HMS16TG4CGR
关闭
打印
Allen-Bradley 1783-HMS16TG4CGR product image
电话:
呼叫
Rockwell Automation Home
Copyright ©2026 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页
  2. Chevron LeftChevron Left 产品
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose