Product at a glance
Rockwell Automation announces that as of December 31, 2025, the CompactLogix DeviceNet Scanner Module will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
Discontinued Date:
December 31, 2025
Replacement Category:
Engineering Replacement
替换产品:
1788-EN2DNR
[https://www.rockwellautomation.com.cn/products/details.1788-EN2DNR.html]
Product at a glance
Depth | 87mm, 3.43" |
---|
Number of HW-interfaces industrial Ethernet | 1 |
---|---|
Suitable for safety functions | False |
With optical interface | False |
Supporting protocol for TCP/IP | False |
Supporting protocol for DeviceNet | True |
Supporting protocol for other bus systems | False |
Redundancy | False |
IO link master | False |
Supporting protocol for DeviceNet Safety | False |
Supporting protocol for EtherNet/IP | False |
Type of data transmission | Other |
Power dissipation | 4.7 W |
Enclosure type rating | None (open-style) |
Number of nodes, max | 64 nodes |
DeviceNet current draw | 110mA @ 24V DC Class 2/SELV |
Current draw | 440mA @ 5.2V DC |
Ports | 1 DeviceNet open-style 5-pin linear plug |
Wire category | 2 - on communication ports |
Wire size | 802.3 compliant shielded or unshielded twisted pair |
Isolation voltage | 30V (continuous), basic insulation type, DeviceNet to backplane, Type tested at 710V DC @ 60s |
Supporting protocol for LON | False |
Supporting protocol for ASI | False |
Supporting protocol for PROFIBUS | False |
Supporting protocol for CAN | False |
Supporting protocol for INTERBUS | False |
Supporting protocol for KNX | False |
Supporting protocol for Modbus | False |
Supporting protocol for Data-Highway | False |
Supporting protocol for SUCONET | False |
With potential separation | False |
Supporting protocol for SERCOS | False |
Supporting protocol for INTERBUS-Safety | False |
Radio standard Bluetooth | False |
Radio standard Wi-Fi 802.11 | False |
Supporting protocol for AS-Interface Safety at Work | False |
Supporting protocol for Foundation Fieldbus | False |
Supporting protocol for PROFINET CBA | False |
Supporting protocol for PROFINET IO | False |
Supporting protocol for PROFIsafe | False |
Supporting protocol for SafetyBUS p | False |
Radio standard GPRS | False |
Radio standard GSM | False |
Radio standard UMTS | False |
Slot width | 1 |
Power supply distance rating | 4 modules |
DeviceNet current range | 11...25V DC |
DeviceNet connector torque | 0.56 nm |
DeviceNet communication rate | 125 Kbps (500 m max), 250 Kbps (250 m max), 500 Kbps (100 m max) |
Width | 50 mm |
---|---|
Height | 118 mm |
Depth | 87 mm |
Weight, approx | 0.28 kg |
Module location | DIN rail or panel mount |
Mounting screw torque | 1.16 Nm (10 in-lb) - use M4 or #8 screws |
Surrounding air temperature, max | 60 °C |
---|---|
Emissions | CISPR 11 (IEC 61000-6-4): Group 1, Class A |
Vibration | 2 G @ 10...500 Hz |
ESD immunity | 6 kV contact discharges, 8 kV air discharges |
EFT/B immunity | ±2kV @ 5kHz on communications ports |
Relative humidity | 5...95% noncondensing |
Shock | Operating: 30 G |
Conducted RF immunity | 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz |
Surge transient immunity | ±2 kV line-earth (CM) on communication ports |
Nonoperating temperature | -40 to 85 °C |
Operating temperature | 0 to 60 °C |
Radiated RF immunity | 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 1 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz |
North American temperature code | T3C |
---|
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
类型 | 资源 | 发布 |
---|---|---|
General | Installation Instructions | 1769-IN060 |
General | Product Cutsheet | -- |
General | Selection Guide | 1769-SG001 |
Technical Data | 1769-td007_-en-p | 1769-TD007 |
User Manual | 1769-um021_-en-p | 1769-UM021 |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center
Search the Literature Library
Available Downloads
- EDS files for 1769-SDN
- EDS files for 1769-SDN A v4.004
- Documentation for 1769-SDN v4.004
- EDS files for 1769-SDN (multi)
- EDS files for CompactLogix Family (multi)
- Firmware for 1769-SDN V4.004
- Registro Italiano Navale
This product was certified with the above certifications as of 2025-09-07. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Technical Specifications
Depth | 87mm, 3.43" |
---|
Number of HW-interfaces industrial Ethernet | 1 |
---|---|
Suitable for safety functions | False |
With optical interface | False |
Supporting protocol for TCP/IP | False |
Supporting protocol for DeviceNet | True |
Supporting protocol for other bus systems | False |
Redundancy | False |
IO link master | False |
Supporting protocol for DeviceNet Safety | False |
Supporting protocol for EtherNet/IP | False |
Type of data transmission | Other |
Power dissipation | 4.7 W |
Enclosure type rating | None (open-style) |
Number of nodes, max | 64 nodes |
DeviceNet current draw | 110mA @ 24V DC Class 2/SELV |
Current draw | 440mA @ 5.2V DC |
Ports | 1 DeviceNet open-style 5-pin linear plug |
Wire category | 2 - on communication ports |
Wire size | 802.3 compliant shielded or unshielded twisted pair |
Isolation voltage | 30V (continuous), basic insulation type, DeviceNet to backplane, Type tested at 710V DC @ 60s |
Supporting protocol for LON | False |
Supporting protocol for ASI | False |
Supporting protocol for PROFIBUS | False |
Supporting protocol for CAN | False |
Supporting protocol for INTERBUS | False |
Supporting protocol for KNX | False |
Supporting protocol for Modbus | False |
Supporting protocol for Data-Highway | False |
Supporting protocol for SUCONET | False |
With potential separation | False |
Supporting protocol for SERCOS | False |
Supporting protocol for INTERBUS-Safety | False |
Radio standard Bluetooth | False |
Radio standard Wi-Fi 802.11 | False |
Supporting protocol for AS-Interface Safety at Work | False |
Supporting protocol for Foundation Fieldbus | False |
Supporting protocol for PROFINET CBA | False |
Supporting protocol for PROFINET IO | False |
Supporting protocol for PROFIsafe | False |
Supporting protocol for SafetyBUS p | False |
Radio standard GPRS | False |
Radio standard GSM | False |
Radio standard UMTS | False |
Slot width | 1 |
Power supply distance rating | 4 modules |
DeviceNet current range | 11...25V DC |
DeviceNet connector torque | 0.56 nm |
DeviceNet communication rate | 125 Kbps (500 m max), 250 Kbps (250 m max), 500 Kbps (100 m max) |
Width | 50 mm |
---|---|
Height | 118 mm |
Depth | 87 mm |
Weight, approx | 0.28 kg |
Module location | DIN rail or panel mount |
Mounting screw torque | 1.16 Nm (10 in-lb) - use M4 or #8 screws |
Surrounding air temperature, max | 60 °C |
---|---|
Emissions | CISPR 11 (IEC 61000-6-4): Group 1, Class A |
Vibration | 2 G @ 10...500 Hz |
ESD immunity | 6 kV contact discharges, 8 kV air discharges |
EFT/B immunity | ±2kV @ 5kHz on communications ports |
Relative humidity | 5...95% noncondensing |
Shock | Operating: 30 G |
Conducted RF immunity | 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz |
Surge transient immunity | ±2 kV line-earth (CM) on communication ports |
Nonoperating temperature | -40 to 85 °C |
Operating temperature | 0 to 60 °C |
Radiated RF immunity | 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 1 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz |
North American temperature code | T3C |
---|
Drawings
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
文档
Installation Instructions
General
1769-IN060 |
Product Cutsheet
General
-- |
Selection Guide
General
1769-SG001 |
1769-td007_-en-p
Technical Data
1769-TD007 |
1769-um021_-en-p
User Manual
1769-UM021 |
类型 | 资源 | 发布 |
---|---|---|
General | Installation Instructions | 1769-IN060 |
General | Product Cutsheet | -- |
General | Selection Guide | 1769-SG001 |
Technical Data | 1769-td007_-en-p | 1769-TD007 |
User Manual | 1769-um021_-en-p | 1769-UM021 |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center
Search the Literature Library
下载
Available Downloads
- EDS files for 1769-SDN
- EDS files for 1769-SDN A v4.004
- Documentation for 1769-SDN v4.004
- EDS files for 1769-SDN (multi)
- EDS files for CompactLogix Family (multi)
- Firmware for 1769-SDN V4.004
认证
- Registro Italiano Navale
This product was certified with the above certifications as of 2025-09-07. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Loading

Copyright ©2025 Rockwell Automation, Inc.