1768-L45S
Compact GuardLogix CPU L45S 3M/1M
Rockwell Automation announces that as of October 30, 2020, the Compact GuardLogix CPU L45S 3M/1M will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
October 30, 2020
替代类别:
Engineering Replacement
Product at a glance
Rockwell Automation announces that as of October 30, 2020, the Compact GuardLogix CPU L45S 3M/1M will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
October 30, 2020
替代类别:
Engineering Replacement
Product at a glance
| Class |
Progmable Logic Controller Module
|
|---|---|
| Embedded Network Port |
None
|
| L4x platform - controllers |
CompactLogix L45 Safety Processor, 3.0MB Memory, 1.0MB Safety Memory
|
| Local Programming Port |
1 RS232
|
| Memory |
3 MB
|
| Non Volatile Memory Option |
CompactFlash
|
| Safety Memory |
1 MB
|
| Voltage type |
DC
|
|---|---|
| LED indicator inputs |
False
|
| LED indicator outputs |
False
|
| Number of 1768 modules, max |
4
|
| Number of 1768 motion modules, max |
4
|
| Number of I/O banks, max |
3
|
| Number of 1769 I/O modules, max |
30
|
| Power dissipation |
9.5 W
|
| Slot width |
1.5
|
| Power consumption |
50.4 W
|
| 1768 current draw |
5.6A @ 5V DC
|
| Total 1768 and 1769 current draw |
7.6A @ 5V DC
|
| Backplane current draw |
2.1A @ 24V DC
|
| Available user memory |
3 MB standard, 1 MB safety
|
| Programming languages |
Standard task: all languages, Safety task: relay ladder, safety application instructions
|
| Protection for local controls |
False
|
| Failsafe model |
False
|
| Communication medium fibre optic |
False
|
| Communication medium wireless |
False
|
| Expandable |
True
|
| Standard applications available |
True
|
| Communication medium copper |
True
|
| Communications protocol |
Other
|
| Communication bus |
RS-232
|
| Number of 1768 communication modules, max |
2
|
| Power supply distance rating |
4 modules
|
| 1769 current draw |
2.0A @ 5V DC
|
| Power supply |
1768-PA3, 1768-PB3
|
| Wire category |
2 - on communication ports
|
| Module expansion capacity |
Two 1768 modules, Sixteen 1769 modules
|
| Serial cable |
1756-CP3 or 1747-CP3, right angle connector to controller, straight to serial port, 3 m
|
| Isolation voltage |
30V (continuous), functional insulation type, Type tested at 500V AC @ 60s, RS-232 to system
|
| DIN-rail mounting |
True
|
|---|---|
| Weight, approx |
0.45 kg
|
| With display |
False
|
| With PC connection |
True
|
| Module location |
DIN rail or panel mount
|
| Communication ports |
RS-232, Fully isolated, 38.4 Kbps max
|
| Panel-mounting screw torque |
1.16 Nm (10 in-lb) - use M4 or #8 screws
|
| Width |
89.6 mm
|
|---|---|
| Height |
131.6 mm
|
| Depth |
122.1 mm
|
| With base plate |
False
|
| Suitable for front mounting |
True
|
| Enclosure type rating |
None (open-style)
|
| Shock |
Operating: 30 G
|
|---|---|
| Surrounding air temperature, max |
60 °C
|
| Operating temperature |
0 °C
|
| Storage temperature |
-40 °C
|
| Vibration |
5 G @ 10...500 Hz
|
| Relative humidity |
5...95% noncondensing
|
| Emissions |
CISPR 11 (IEC 61000-6-4)
|
| EFT/B immunity |
±4kV @ 5kHz on communication ports
|
| ESD immunity |
6 kV contact discharges, 8 kV air discharges
|
| Surge transient immunity |
±2 kV line-earth (CM) on communication ports
|
| Conducted RF immunity |
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
|
| Radiated RF immunity |
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
|
| Explosion-proof |
False
|
|---|---|
| North American temperature code |
T4
|
| IEC temperature code |
T4
|
| 类型 | 资源 | 出版 |
|---|---|---|
| Technical Data | 1769-td005_-en-p | 1769-TD005 |
技术规格
| Class |
Progmable Logic Controller Module
|
|---|---|
| Embedded Network Port |
None
|
| L4x platform - controllers |
CompactLogix L45 Safety Processor, 3.0MB Memory, 1.0MB Safety Memory
|
| Local Programming Port |
1 RS232
|
| Memory |
3 MB
|
| Non Volatile Memory Option |
CompactFlash
|
| Safety Memory |
1 MB
|
| Voltage type |
DC
|
|---|---|
| LED indicator inputs |
False
|
| LED indicator outputs |
False
|
| Number of 1768 modules, max |
4
|
| Number of 1768 motion modules, max |
4
|
| Number of I/O banks, max |
3
|
| Number of 1769 I/O modules, max |
30
|
| Power dissipation |
9.5 W
|
| Slot width |
1.5
|
| Power consumption |
50.4 W
|
| 1768 current draw |
5.6A @ 5V DC
|
| Total 1768 and 1769 current draw |
7.6A @ 5V DC
|
| Backplane current draw |
2.1A @ 24V DC
|
| Available user memory |
3 MB standard, 1 MB safety
|
| Programming languages |
Standard task: all languages, Safety task: relay ladder, safety application instructions
|
| Protection for local controls |
False
|
| Failsafe model |
False
|
| Communication medium fibre optic |
False
|
| Communication medium wireless |
False
|
| Expandable |
True
|
| Standard applications available |
True
|
| Communication medium copper |
True
|
| Communications protocol |
Other
|
| Communication bus |
RS-232
|
| Number of 1768 communication modules, max |
2
|
| Power supply distance rating |
4 modules
|
| 1769 current draw |
2.0A @ 5V DC
|
| Power supply |
1768-PA3, 1768-PB3
|
| Wire category |
2 - on communication ports
|
| Module expansion capacity |
Two 1768 modules, Sixteen 1769 modules
|
| Serial cable |
1756-CP3 or 1747-CP3, right angle connector to controller, straight to serial port, 3 m
|
| Isolation voltage |
30V (continuous), functional insulation type, Type tested at 500V AC @ 60s, RS-232 to system
|
| DIN-rail mounting |
True
|
|---|---|
| Weight, approx |
0.45 kg
|
| With display |
False
|
| With PC connection |
True
|
| Module location |
DIN rail or panel mount
|
| Communication ports |
RS-232, Fully isolated, 38.4 Kbps max
|
| Panel-mounting screw torque |
1.16 Nm (10 in-lb) - use M4 or #8 screws
|
| Width |
89.6 mm
|
|---|---|
| Height |
131.6 mm
|
| Depth |
122.1 mm
|
| With base plate |
False
|
| Suitable for front mounting |
True
|
| Enclosure type rating |
None (open-style)
|
| Shock |
Operating: 30 G
|
|---|---|
| Surrounding air temperature, max |
60 °C
|
| Operating temperature |
0 °C
|
| Storage temperature |
-40 °C
|
| Vibration |
5 G @ 10...500 Hz
|
| Relative humidity |
5...95% noncondensing
|
| Emissions |
CISPR 11 (IEC 61000-6-4)
|
| EFT/B immunity |
±4kV @ 5kHz on communication ports
|
| ESD immunity |
6 kV contact discharges, 8 kV air discharges
|
| Surge transient immunity |
±2 kV line-earth (CM) on communication ports
|
| Conducted RF immunity |
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
|
| Radiated RF immunity |
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
|
| Explosion-proof |
False
|
|---|---|
| North American temperature code |
T4
|
| IEC temperature code |
T4
|
文档
|
1769-td005_-en-p
Technical Data
1769-TD005 |
| 类型 | 资源 | 出版 |
|---|---|---|