Class
Progmable Logic Controller Module
Depth
87
digital output modules
16 Point VAC/VDC Relay Output Module
Height
90
I/O Isolation
Isolated
I/O Status Indication
LED
Module Interfaces
Relay output
Number Of Channels
16 point
Output
16 Point, Relay
Temperature Rating
-20…65 °C (-4…149 °F)
Number of digital outputs
16
Time delay at signal exchange
10 ms
Suitable for safety functions
False
Digital inputs configurable
False
Digital outputs configurable
False
Type of output voltage
AC/DC
Type of digital output
Relay
Type of electric connection
Screw connection
Heat dissipation, max
6.1 W
Continuous current per common, max
8 A
Continuous current per module, max
16 A
Continuous current per point, max
2.5 A
Bus current draw, max
180mA @ 24V DC (4.32 W)
Signal delay, resistive load, max
On Delay: 10 ms Off Delay: 10 ms
Power supply distance rating
6 (The module may not be more than 6 modules away from the power supply.)
Isolated groups
Group 1: Outputs 0...7, Group 2: Outputs 8...15
Output group to backplane isolation
Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (IEC Class 2 reinforced insulation)
Output group to output group isolation
Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (basic insulation), 150V AC working voltage (IEC Class 2 reinforced insulation)
Redundancy
False
Short-circuit protection, outputs available
False
Width
40.4 mm
Height
90 mm
Depth
87 mm
Weight
285 g
Shock
Operating: 30G panel mounted, 3 pulses per axis Relay ops: 7G
Vibration
Operating: 10...500 Hz, 5G, 0.030 in. max. peak-to-peak, 2 hr per axis Relay ops: 1.5G
Relay output, break volt-ampere
28VA @ 24V DC
Relay output, continuous
2.5A @ 240V AC
Relay output, break
1.5A @ 120V AC
Relay output, make
7.5A @ 240V AC
Relay output, make volt-ampere
28VA @ 24V DC
Voltage category
AC/DC normally open relay
On-state current, min
10 mA
Operating voltage
5...265V AC
Off-state leakage current, max
0 mA
ESD immunity
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
Conducted RF immunity
IEC 1000-4-6: 10V @ 0.15...80MHz
EFT/B immunity
IEC1000-4-4: 2kV @ 5kHz
Hazardous environment class
Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
Operating temperature
-20 to 65 °C
Surge transient immunity
IEC1000-4-5: 2 kV common mode, 1 kV differential mode
Radiated RF immunity
IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
Altitude
2000 m
Storage temperature
-40 °C
Radiated and conducted emissions
EN50081-2: Class A
Operating humidity
5...95% noncondensing
图纸
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
图纸
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
类型 资源 出版
General Selection Guide 1761-SG001
General Product Cutsheet --
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
UL Listed
  • UL Listed Hazardous
  • UL Listed

This product was certified with the above certifications as of 2025-07-20. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
技术规格
Class
Progmable Logic Controller Module
Depth
87
digital output modules
16 Point VAC/VDC Relay Output Module
Height
90
I/O Isolation
Isolated
I/O Status Indication
LED
Module Interfaces
Relay output
Number Of Channels
16 point
Output
16 Point, Relay
Temperature Rating
-20…65 °C (-4…149 °F)
Number of digital outputs
16
Time delay at signal exchange
10 ms
Suitable for safety functions
False
Digital inputs configurable
False
Digital outputs configurable
False
Type of output voltage
AC/DC
Type of digital output
Relay
Type of electric connection
Screw connection
Heat dissipation, max
6.1 W
Continuous current per common, max
8 A
Continuous current per module, max
16 A
Continuous current per point, max
2.5 A
Bus current draw, max
180mA @ 24V DC (4.32 W)
Signal delay, resistive load, max
On Delay: 10 ms Off Delay: 10 ms
Power supply distance rating
6 (The module may not be more than 6 modules away from the power supply.)
Isolated groups
Group 1: Outputs 0...7, Group 2: Outputs 8...15
Output group to backplane isolation
Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (IEC Class 2 reinforced insulation)
Output group to output group isolation
Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (basic insulation), 150V AC working voltage (IEC Class 2 reinforced insulation)
Redundancy
False
Short-circuit protection, outputs available
False
Width
40.4 mm
Height
90 mm
Depth
87 mm
Weight
285 g
Shock
Operating: 30G panel mounted, 3 pulses per axis Relay ops: 7G
Vibration
Operating: 10...500 Hz, 5G, 0.030 in. max. peak-to-peak, 2 hr per axis Relay ops: 1.5G
Relay output, break volt-ampere
28VA @ 24V DC
Relay output, continuous
2.5A @ 240V AC
Relay output, break
1.5A @ 120V AC
Relay output, make
7.5A @ 240V AC
Relay output, make volt-ampere
28VA @ 24V DC
Voltage category
AC/DC normally open relay
On-state current, min
10 mA
Operating voltage
5...265V AC
Off-state leakage current, max
0 mA
ESD immunity
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
Conducted RF immunity
IEC 1000-4-6: 10V @ 0.15...80MHz
EFT/B immunity
IEC1000-4-4: 2kV @ 5kHz
Hazardous environment class
Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
Operating temperature
-20 to 65 °C
Surge transient immunity
IEC1000-4-5: 2 kV common mode, 1 kV differential mode
Radiated RF immunity
IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
Altitude
2000 m
Storage temperature
-40 °C
Radiated and conducted emissions
EN50081-2: Class A
Operating humidity
5...95% noncondensing
图纸
图纸
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
图纸
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
Selection Guide General
1761-SG001
Product Cutsheet General
--
类型 资源 出版
General Selection Guide 1761-SG001
General Product Cutsheet --
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
认证
UL Listed
  • UL Listed Hazardous
  • UL Listed

This product was certified with the above certifications as of 2025-07-20. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
Loading
寻找最近经销商
更改位置
EmailEmail
PhonePhone
寻找合作伙伴
MicroLogix 16 Point Relay Output Module
CloseClose
1762-ow16
关闭
打印
Allen-Bradley 1762-ow16 product image
电话:
呼叫
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页
  2. Chevron LeftChevron Left 产品
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose