Class | Progmable Logic Controller Module |
---|---|
Depth | 87 |
digital output modules | 16 Point VAC/VDC Relay Output Module |
Height | 90 |
I/O Isolation | Isolated |
I/O Status Indication | LED |
Module Interfaces | Relay output |
Number Of Channels | 16 point |
Output | 16 Point, Relay |
Temperature Rating | -20…65 °C (-4…149 °F) |
Number of digital outputs | 16 |
---|---|
Time delay at signal exchange | 10 ms |
Suitable for safety functions | False |
Digital inputs configurable | False |
Digital outputs configurable | False |
Type of output voltage | AC/DC |
Type of digital output | Relay |
Type of electric connection | Screw connection |
Heat dissipation, max | 6.1 W |
Continuous current per common, max | 8 A |
Continuous current per module, max | 16 A |
Continuous current per point, max | 2.5 A |
Bus current draw, max | 180mA @ 24V DC (4.32 W) |
Signal delay, resistive load, max | On Delay: 10 ms Off Delay: 10 ms |
Power supply distance rating | 6 (The module may not be more than 6 modules away from the power supply.) |
Isolated groups | Group 1: Outputs 0...7, Group 2: Outputs 8...15 |
Output group to backplane isolation | Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (IEC Class 2 reinforced insulation) |
Output group to output group isolation | Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (basic insulation), 150V AC working voltage (IEC Class 2 reinforced insulation) |
Redundancy | False |
Short-circuit protection, outputs available | False |
Width | 40.4 mm |
---|---|
Height | 90 mm |
Depth | 87 mm |
Weight | 285 g |
Shock | Operating: 30G panel mounted, 3 pulses per axis Relay ops: 7G |
Vibration | Operating: 10...500 Hz, 5G, 0.030 in. max. peak-to-peak, 2 hr per axis Relay ops: 1.5G |
Relay output, break volt-ampere | 28VA @ 24V DC |
---|---|
Relay output, continuous | 2.5A @ 240V AC |
Relay output, break | 1.5A @ 120V AC |
Relay output, make | 7.5A @ 240V AC |
Relay output, make volt-ampere | 28VA @ 24V DC |
Voltage category | AC/DC normally open relay |
---|---|
On-state current, min | 10 mA |
Operating voltage | 5...265V AC |
Off-state leakage current, max | 0 mA |
---|
ESD immunity | IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect |
---|---|
Conducted RF immunity | IEC 1000-4-6: 10V @ 0.15...80MHz |
EFT/B immunity | IEC1000-4-4: 2kV @ 5kHz |
Hazardous environment class | Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213) |
Operating temperature | -20 to 65 °C |
Surge transient immunity | IEC1000-4-5: 2 kV common mode, 1 kV differential mode |
Radiated RF immunity | IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier |
Altitude | 2000 m |
Storage temperature | -40 °C |
Radiated and conducted emissions | EN50081-2: Class A |
Operating humidity | 5...95% noncondensing |
图纸 | |
---|---|
3-Dimensional STEP model (STP) | Download (ZIP) |
Product Drawing | Drawing (DWG) |
图纸 |
---|
3-Dimensional STEP model (STP) Download (ZIP) |
Product Drawing Drawing (DWG) |
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
类型 | 资源 | 出版 |
---|---|---|
General | Product Cutsheet | -- |
General | Selection Guide | 1761-SG001 |
- UL Listed Hazardous
- UL Listed
This product was certified with the above certifications as of 2025-07-20. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
技术规格
Class | Progmable Logic Controller Module |
---|---|
Depth | 87 |
digital output modules | 16 Point VAC/VDC Relay Output Module |
Height | 90 |
I/O Isolation | Isolated |
I/O Status Indication | LED |
Module Interfaces | Relay output |
Number Of Channels | 16 point |
Output | 16 Point, Relay |
Temperature Rating | -20…65 °C (-4…149 °F) |
Number of digital outputs | 16 |
---|---|
Time delay at signal exchange | 10 ms |
Suitable for safety functions | False |
Digital inputs configurable | False |
Digital outputs configurable | False |
Type of output voltage | AC/DC |
Type of digital output | Relay |
Type of electric connection | Screw connection |
Heat dissipation, max | 6.1 W |
Continuous current per common, max | 8 A |
Continuous current per module, max | 16 A |
Continuous current per point, max | 2.5 A |
Bus current draw, max | 180mA @ 24V DC (4.32 W) |
Signal delay, resistive load, max | On Delay: 10 ms Off Delay: 10 ms |
Power supply distance rating | 6 (The module may not be more than 6 modules away from the power supply.) |
Isolated groups | Group 1: Outputs 0...7, Group 2: Outputs 8...15 |
Output group to backplane isolation | Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (IEC Class 2 reinforced insulation) |
Output group to output group isolation | Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (basic insulation), 150V AC working voltage (IEC Class 2 reinforced insulation) |
Redundancy | False |
Short-circuit protection, outputs available | False |
Width | 40.4 mm |
---|---|
Height | 90 mm |
Depth | 87 mm |
Weight | 285 g |
Shock | Operating: 30G panel mounted, 3 pulses per axis Relay ops: 7G |
Vibration | Operating: 10...500 Hz, 5G, 0.030 in. max. peak-to-peak, 2 hr per axis Relay ops: 1.5G |
Relay output, break volt-ampere | 28VA @ 24V DC |
---|---|
Relay output, continuous | 2.5A @ 240V AC |
Relay output, break | 1.5A @ 120V AC |
Relay output, make | 7.5A @ 240V AC |
Relay output, make volt-ampere | 28VA @ 24V DC |
Voltage category | AC/DC normally open relay |
---|---|
On-state current, min | 10 mA |
Operating voltage | 5...265V AC |
Off-state leakage current, max | 0 mA |
---|
ESD immunity | IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect |
---|---|
Conducted RF immunity | IEC 1000-4-6: 10V @ 0.15...80MHz |
EFT/B immunity | IEC1000-4-4: 2kV @ 5kHz |
Hazardous environment class | Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213) |
Operating temperature | -20 to 65 °C |
Surge transient immunity | IEC1000-4-5: 2 kV common mode, 1 kV differential mode |
Radiated RF immunity | IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier |
Altitude | 2000 m |
Storage temperature | -40 °C |
Radiated and conducted emissions | EN50081-2: Class A |
Operating humidity | 5...95% noncondensing |
图纸
图纸 | |
---|---|
3-Dimensional STEP model (STP) | Download (ZIP) |
Product Drawing | Drawing (DWG) |
图纸 |
---|
3-Dimensional STEP model (STP) Download (ZIP) |
Product Drawing Drawing (DWG) |
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
Product Cutsheet
General
-- |
Selection Guide
General
1761-SG001 |
类型 | 资源 | 出版 |
---|---|---|
General | Product Cutsheet | -- |
General | Selection Guide | 1761-SG001 |
认证
- UL Listed Hazardous
- UL Listed
This product was certified with the above certifications as of 2025-07-20. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.