| Class |
Progmable Logic Controller Module
|
|---|---|
| Depth |
87
|
| digital output modules |
6 Point 24V DC Isolated High Current Relay Output Module
|
| Height |
90
|
| I/O Isolation |
Isolated
|
| I/O Status Indication |
LED
|
| Module Interfaces |
Relay output
|
| Number Of Channels |
6 point
|
| Output |
6 Point, Isolated AC/DC Relay
|
| Temperature Rating |
0…55 °C (32…131 °F)
|
| Terminal Type |
Isolated
|
| Number of digital outputs |
6
|
|---|---|
| Suitable for safety functions |
No
|
| Digital inputs configurable |
No
|
| Digital outputs configurable |
No
|
| Type of output voltage |
AC/DC
|
| Type of digital output |
Relay
|
| Type of electric connection |
Screw connection
|
| Heat dissipation, max |
2.8 W
|
| Continuous current per common, max |
7 A
|
| Bus current draw, max |
110mA @ 5V DC (0.55 W)
|
| Signal delay, resistive load |
ON delay: 10 ms (max) 6 ms (typical) OFF delay: 20 ms (max) 12 ms (typical)
|
| Power supply distance rating |
6 (The module may not be more than 6 modules away from the power supply.)
|
| Isolated groups |
All 6 Outputs Individually Isolated
|
| Output group to backplane isolation |
Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (IEC Class 2 reinforced insulation)
|
| Output group to output group isolation |
Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (basic insulation), 150V AC working voltage (IEC Class 2 reinforced insulation)
|
| Redundancy |
No
|
| Short-circuit protection, outputs available |
No
|
| Width |
40.4 mm
|
|---|---|
| Height |
90 mm
|
| Depth |
87 mm
|
| Weight |
220 g
|
| Shock |
Operating: 30G panel mounted, 3 pulses per axis Relay ops: 7G
|
| Vibration |
Operating: 10...500 Hz, 5G, 0.030 in. max. peak-to-peak, 2 hr per axis Relay ops: 1.5G
|
| Relay output, break volt-ampere |
50VA @ 125V DC
|
|---|---|
| Relay output, continuous |
7A @ 24V DC
|
| Relay output, break |
7A @ 24V DC
|
| Relay output, make |
7A @ 24V DC
|
| Relay output, make volt-ampere |
50VA @ 125V DC
|
| Controlled load current per module, max |
6A @ 240V AC
|
| Voltage category |
AC/DC Type C relay
|
|---|---|
| On-state current, min |
100 mA
|
| Operating voltage |
5...265V AC
|
| Off-state leakage current, max |
0 mA
|
|---|
| ESD immunity |
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
|
|---|---|
| Conducted RF immunity |
IEC 1000-4-6: 10V @ 0.15...80MHz
|
| EFT/B immunity |
IEC1000-4-4: 2kV @ 5kHz
|
| Hazardous environment class |
Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
|
| Operating temperature |
-20 to 65 °C
|
| Surge transient immunity |
IEC1000-4-5: 2 kV common mode, 1 kV differential mode
|
| Radiated RF immunity |
IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
|
| Altitude |
2000 m
|
| Storage temperature |
-40 °C
|
| Radiated and conducted emissions |
EN50081-2: Class A
|
| Operating humidity |
5...95% noncondensing
|
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
| 类型 | 资源 | 出版 |
|---|---|---|
| 常规 | Selection Guide | 1761-SG001 |
| 常规 | Product Cutsheet | -- |
- UL Listed
- UL Listed Hazardous
This product was certified with the above certifications as of 2025-07-27. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
技术规格
| Class |
Progmable Logic Controller Module
|
|---|---|
| Depth |
87
|
| digital output modules |
6 Point 24V DC Isolated High Current Relay Output Module
|
| Height |
90
|
| I/O Isolation |
Isolated
|
| I/O Status Indication |
LED
|
| Module Interfaces |
Relay output
|
| Number Of Channels |
6 point
|
| Output |
6 Point, Isolated AC/DC Relay
|
| Temperature Rating |
0…55 °C (32…131 °F)
|
| Terminal Type |
Isolated
|
| Number of digital outputs |
6
|
|---|---|
| Suitable for safety functions |
No
|
| Digital inputs configurable |
No
|
| Digital outputs configurable |
No
|
| Type of output voltage |
AC/DC
|
| Type of digital output |
Relay
|
| Type of electric connection |
Screw connection
|
| Heat dissipation, max |
2.8 W
|
| Continuous current per common, max |
7 A
|
| Bus current draw, max |
110mA @ 5V DC (0.55 W)
|
| Signal delay, resistive load |
ON delay: 10 ms (max) 6 ms (typical) OFF delay: 20 ms (max) 12 ms (typical)
|
| Power supply distance rating |
6 (The module may not be more than 6 modules away from the power supply.)
|
| Isolated groups |
All 6 Outputs Individually Isolated
|
| Output group to backplane isolation |
Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (IEC Class 2 reinforced insulation)
|
| Output group to output group isolation |
Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (basic insulation), 150V AC working voltage (IEC Class 2 reinforced insulation)
|
| Redundancy |
No
|
| Short-circuit protection, outputs available |
No
|
| Width |
40.4 mm
|
|---|---|
| Height |
90 mm
|
| Depth |
87 mm
|
| Weight |
220 g
|
| Shock |
Operating: 30G panel mounted, 3 pulses per axis Relay ops: 7G
|
| Vibration |
Operating: 10...500 Hz, 5G, 0.030 in. max. peak-to-peak, 2 hr per axis Relay ops: 1.5G
|
| Relay output, break volt-ampere |
50VA @ 125V DC
|
|---|---|
| Relay output, continuous |
7A @ 24V DC
|
| Relay output, break |
7A @ 24V DC
|
| Relay output, make |
7A @ 24V DC
|
| Relay output, make volt-ampere |
50VA @ 125V DC
|
| Controlled load current per module, max |
6A @ 240V AC
|
| Voltage category |
AC/DC Type C relay
|
|---|---|
| On-state current, min |
100 mA
|
| Operating voltage |
5...265V AC
|
| Off-state leakage current, max |
0 mA
|
|---|
| ESD immunity |
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
|
|---|---|
| Conducted RF immunity |
IEC 1000-4-6: 10V @ 0.15...80MHz
|
| EFT/B immunity |
IEC1000-4-4: 2kV @ 5kHz
|
| Hazardous environment class |
Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
|
| Operating temperature |
-20 to 65 °C
|
| Surge transient immunity |
IEC1000-4-5: 2 kV common mode, 1 kV differential mode
|
| Radiated RF immunity |
IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
|
| Altitude |
2000 m
|
| Storage temperature |
-40 °C
|
| Radiated and conducted emissions |
EN50081-2: Class A
|
| Operating humidity |
5...95% noncondensing
|
图纸
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
|
Selection Guide
常规
1761-SG001 |
|
Product Cutsheet
常规
-- |
| 类型 | 资源 | 出版 |
|---|---|---|
| 常规 | Selection Guide | 1761-SG001 |
| 常规 | Product Cutsheet | -- |
认证
- UL Listed
- UL Listed Hazardous
This product was certified with the above certifications as of 2025-07-27. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
技术说明
Loading
Copyright ©2025 Rockwell Automation, Inc.