| Class | Progmable Logic Controller Module |
|---|---|
| Depth | 87 |
| digital output modules | 8 Point VAC/VDC Relay Output Module |
| Height | 90 |
| I/O Isolation | Isolated |
| I/O Status Indication | LED |
| Module Interfaces | Relay output |
| Number Of Channels | 8 Point |
| Output | 8 Point, Relay |
| Temperature Rating | 0…55 °C (32…131 °F) |
| Number of digital outputs | 8 |
|---|---|
| Time delay at signal exchange | 10 ms |
| Suitable for safety functions | False |
| Digital inputs configurable | False |
| Digital outputs configurable | False |
| Type of output voltage | AC/DC |
| Type of digital output | Relay |
| Type of electric connection | Screw connection |
| Heat dissipation, max | 2.9 W |
| Continuous current per common, max | 8 A |
| Continuous current per module, max | 16 A |
| Continuous current per point, max | 2.5 A |
| Bus current draw, max | 90mA @ 24V DC (2.16 W) |
| Signal delay, resistive load, max | On Delay: 10 ms Off Delay: 10 ms |
| Power supply distance rating | 6 (The module may not be more than 6 modules away from the power supply.) |
| Isolated groups | Group 1: Outputs 0...3, Group 2: Outputs 4...7 |
| Output group to backplane isolation | Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (IEC Class 2 reinforced insulation) |
| Output group to output group isolation | Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (basic insulation), 150V AC working voltage (IEC Class 2 reinforced insulation) |
| Redundancy | False |
| Short-circuit protection, outputs available | False |
| Width | 40.4 mm |
|---|---|
| Height | 90 mm |
| Depth | 87 mm |
| Weight | 228 g |
| Shock | Operating: 30G panel mounted, 3 pulses per axis Relay ops: 7G |
| Vibration | Operating: 10...500 Hz, 5G, 0.030 in. max. peak-to-peak, 2 hr per axis Relay ops: 1.5G |
| Relay output, break volt-ampere | 28VA @ 24V DC |
|---|---|
| Relay output, continuous | 2.5A @ 240V AC |
| Relay output, break | 1.5A @ 120V AC |
| Relay output, make | 7.5A @ 240V AC |
| Relay output, make volt-ampere | 28VA @ 24V DC |
| Voltage category | AC/DC normally open relay |
|---|---|
| On-state current, min | 10 mA |
| Operating voltage | 5...265V AC |
| Off-state leakage current, max | 0 mA |
|---|
| ESD immunity | IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect |
|---|---|
| Conducted RF immunity | IEC 1000-4-6: 10V @ 0.15...80MHz |
| EFT/B immunity | IEC1000-4-4: 2kV @ 5kHz |
| Hazardous environment class | Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213) |
| Operating temperature | -20 to 65 °C |
| Surge transient immunity | IEC1000-4-5: 2 kV common mode, 1 kV differential mode |
| Radiated RF immunity | IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier |
| Altitude | 2000 m |
| Storage temperature | -40 °C |
| Radiated and conducted emissions | EN50081-2: Class A |
| Operating humidity | 5...95% noncondensing |
| 图纸 | |
|---|---|
| 3-Dimensional STEP model (STP) | Download (ZIP) |
| Product Drawing | Drawing (DWG) |
| 图纸 |
|---|
| 3-Dimensional STEP model (STP) Download (ZIP) |
| Product Drawing Drawing (DWG) |
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
| 类型 | 资源 | 出版 |
|---|---|---|
| General | Product Cutsheet | -- |
| General | Selection Guide | 1761-SG001 |
- UL Listed Hazardous
- UKCA DOC
This product was certified with the above certifications as of 2025-09-10. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
技术规格
| Class | Progmable Logic Controller Module |
|---|---|
| Depth | 87 |
| digital output modules | 8 Point VAC/VDC Relay Output Module |
| Height | 90 |
| I/O Isolation | Isolated |
| I/O Status Indication | LED |
| Module Interfaces | Relay output |
| Number Of Channels | 8 Point |
| Output | 8 Point, Relay |
| Temperature Rating | 0…55 °C (32…131 °F) |
| Number of digital outputs | 8 |
|---|---|
| Time delay at signal exchange | 10 ms |
| Suitable for safety functions | False |
| Digital inputs configurable | False |
| Digital outputs configurable | False |
| Type of output voltage | AC/DC |
| Type of digital output | Relay |
| Type of electric connection | Screw connection |
| Heat dissipation, max | 2.9 W |
| Continuous current per common, max | 8 A |
| Continuous current per module, max | 16 A |
| Continuous current per point, max | 2.5 A |
| Bus current draw, max | 90mA @ 24V DC (2.16 W) |
| Signal delay, resistive load, max | On Delay: 10 ms Off Delay: 10 ms |
| Power supply distance rating | 6 (The module may not be more than 6 modules away from the power supply.) |
| Isolated groups | Group 1: Outputs 0...3, Group 2: Outputs 4...7 |
| Output group to backplane isolation | Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (IEC Class 2 reinforced insulation) |
| Output group to output group isolation | Verified by one of the following dielectric tests: 1836V AC @ 1s or 2596V DC @ 1s, 265V AC working voltage (basic insulation), 150V AC working voltage (IEC Class 2 reinforced insulation) |
| Redundancy | False |
| Short-circuit protection, outputs available | False |
| Width | 40.4 mm |
|---|---|
| Height | 90 mm |
| Depth | 87 mm |
| Weight | 228 g |
| Shock | Operating: 30G panel mounted, 3 pulses per axis Relay ops: 7G |
| Vibration | Operating: 10...500 Hz, 5G, 0.030 in. max. peak-to-peak, 2 hr per axis Relay ops: 1.5G |
| Relay output, break volt-ampere | 28VA @ 24V DC |
|---|---|
| Relay output, continuous | 2.5A @ 240V AC |
| Relay output, break | 1.5A @ 120V AC |
| Relay output, make | 7.5A @ 240V AC |
| Relay output, make volt-ampere | 28VA @ 24V DC |
| Voltage category | AC/DC normally open relay |
|---|---|
| On-state current, min | 10 mA |
| Operating voltage | 5...265V AC |
| Off-state leakage current, max | 0 mA |
|---|
| ESD immunity | IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect |
|---|---|
| Conducted RF immunity | IEC 1000-4-6: 10V @ 0.15...80MHz |
| EFT/B immunity | IEC1000-4-4: 2kV @ 5kHz |
| Hazardous environment class | Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213) |
| Operating temperature | -20 to 65 °C |
| Surge transient immunity | IEC1000-4-5: 2 kV common mode, 1 kV differential mode |
| Radiated RF immunity | IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier |
| Altitude | 2000 m |
| Storage temperature | -40 °C |
| Radiated and conducted emissions | EN50081-2: Class A |
| Operating humidity | 5...95% noncondensing |
图纸
| 图纸 | |
|---|---|
| 3-Dimensional STEP model (STP) | Download (ZIP) |
| Product Drawing | Drawing (DWG) |
| 图纸 |
|---|
| 3-Dimensional STEP model (STP) Download (ZIP) |
| Product Drawing Drawing (DWG) |
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
|
Product Cutsheet
General
-- |
|
Selection Guide
General
1761-SG001 |
| 类型 | 资源 | 出版 |
|---|---|---|
| General | Product Cutsheet | -- |
| General | Selection Guide | 1761-SG001 |
认证
- UL Listed Hazardous
- UKCA DOC
This product was certified with the above certifications as of 2025-09-10. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
技术说明
Loading