生命周期状态: 产品成熟期
产品概览
可享更换服务
生命周期状态: 产品成熟期
产品概览
可享更换服务
添加到BoM
  • 寻找支持
技术规格
基本信息
Electrical
Environmental
Input Specifications
Output Specifications
General Specifications
Mechanical
Common Specifications
Construction
Certification
图纸
文档
认证
技术说明
Class
Progmable Logic Controller Module
Depth
87
Height
90
I/O Isolation
Isolated
I/O Status Indication
LED
Module Interfaces
Resistance thermom detector input
Number Of Channels
4 point
Temperature Rating
0…55 °C (32…131 °F)
Thermocouple Type
4 Channel, RTD/Resistance Module
Number of analogue inputs
4
Input, current
No
Input, voltage
No
Input, resistor
Yes
Input, resistance thermometer
No
Input, thermocouple
No
Input signal, configurable
Yes
Output, current
No
Output, voltage
No
Output signal configurable
No
Analogue inputs configurable
No
Analogue outputs configurable
No
Type of electric connection
Screw connection
Open-circuit detection time
6 ms
Channel to channel isolation
±10V DC
Input type
604 Ω Nickel-Iron 518
Bus current draw
50mA @ 24V DC, maximum
Fast transient burst
IEC1000-4-4: 2kV @ 5kHz
Update time
Input filter and configuration dependent (typical)
Normal mode rejection ratio
70 dB minimum @ 60 Hz with the 10 or 60 Hz filter selected
Conducted immunity
IEC 1000-4-6: 10 V/m, 80...1000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
Radiated immunity
IEC 61000-4-3: 10 V/m, 80...1000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
Calibration
The module performs autocalibration on channel enable and on a configuration change between channels. You can also prog the module to calibrate every five minutes
Typical accuracy
At 25 ° C (77 °F) ambient with module operating temperature at 25 °C (77 °F)
Resolution
Input filter and configuration dependent
Suitable for safety functions
No
Overload at input terminals
Maximum @ ±35V DC continuous
Surge immunity
IEC1000-4-5: 1kV galvanic gun
Module power LED
ON: indicates power is applied
Excitation current source
0.5 mA and 1.0 mA selectable per channel
Cable impedance
Maximum @ 25 Ω (operating with >25 Ω will reduce accuracy)
Power supply distance rating
6 (the module may not be more than 6 modules away from the system power supply)
Heat dissipation
1.5 total W (the W per point, plus the minimum W, with all points enabled)
Input channel configuration
Via configuration software screen or the user prog (by writing a unique bit pattern into the module’s configuration file)
Accuracy drift
At 0...55 °C ±0.026 °C/°C (0.026 °F/°F) for Pt 385, ±0.007 Ω/°C (0.012 Ω/°F) for 150 Ω range, ±0.023 °C/°C (0.023 °F/°F) for Pt 3916, ±0.023 Ω/°C (0.041 Ω/°F) for 500 Ω range, ±0.012 °C/°C (0.012 °F/°F) for Ni, ±0.043 Ω/°C (0.077 Ω/°F) for 1,000 Ω range,
Operating temperature
-20 °C
ESD immunity
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
Operating altitude
2000 m
Storage temperature
-40 °C
Operating humidity
5...95% noncondensing
A/D converter type
Delta-Sigma
Common mode rejection
>110 dB at 60 Hz (with 10 or 60 Hz filter)
Input impedance
>10 MΩ
Channel diagnostics
Over or under range or open circuit condition by bit reporting for analog inputs
Non-linearity
±0.05% (in % full scale)
Typical overall accuracy
±0.5 °C (°F) for Pt 385
Repeatability
±0.2 Ω for other resistances
Input and output group to system isolation
30V AC/30V DC working voltage type test: 500V AC or 707V DC @ 1min
Vibration
Operating: 10...500 Hz, 5 G, 0.030 in @ maximum peak-to-peak
Shock
Operating: 30 G
Shipping weight, approx
260 g
Hazardous environment class
Class I, Division 2, Hazardous Location, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
Radiated and conducted emissions
EN50081-2: Class A
Recommended cable
Belden 8761 (shielded)
Height
90 mm
Width
40 mm
Depth
87 mm
Noise immunity
NEMA standard ICS 2-230
图纸
产品图纸 图纸 (DWG)
产品图纸 图纸 (DWG)
产品图纸 图纸 (DWG)
产品图纸 图纸 (DWG)
产品图纸 图纸 (DWG)
图纸
产品图纸 图纸 (DWG)
产品图纸 图纸 (DWG)
产品图纸 图纸 (DWG)
产品图纸 图纸 (DWG)
产品图纸 图纸 (DWG)
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
基本信息 出版
Product Cutsheet --
Selection Guide 1761-SG001
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
  • UL Listed Hazardous

截至 2026-01-31,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。

技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
技术规格
Class
Progmable Logic Controller Module
Depth
87
Height
90
I/O Isolation
Isolated
I/O Status Indication
LED
Module Interfaces
Resistance thermom detector input
Number Of Channels
4 point
Temperature Rating
0…55 °C (32…131 °F)
Thermocouple Type
4 Channel, RTD/Resistance Module
Number of analogue inputs
4
Input, current
No
Input, voltage
No
Input, resistor
Yes
Input, resistance thermometer
No
Input, thermocouple
No
Input signal, configurable
Yes
Output, current
No
Output, voltage
No
Output signal configurable
No
Analogue inputs configurable
No
Analogue outputs configurable
No
Type of electric connection
Screw connection
Open-circuit detection time
6 ms
Channel to channel isolation
±10V DC
Input type
604 Ω Nickel-Iron 518
Bus current draw
50mA @ 24V DC, maximum
Fast transient burst
IEC1000-4-4: 2kV @ 5kHz
Update time
Input filter and configuration dependent (typical)
Normal mode rejection ratio
70 dB minimum @ 60 Hz with the 10 or 60 Hz filter selected
Conducted immunity
IEC 1000-4-6: 10 V/m, 80...1000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
Radiated immunity
IEC 61000-4-3: 10 V/m, 80...1000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
Calibration
The module performs autocalibration on channel enable and on a configuration change between channels. You can also prog the module to calibrate every five minutes
Typical accuracy
At 25 ° C (77 °F) ambient with module operating temperature at 25 °C (77 °F)
Resolution
Input filter and configuration dependent
Suitable for safety functions
No
Overload at input terminals
Maximum @ ±35V DC continuous
Surge immunity
IEC1000-4-5: 1kV galvanic gun
Module power LED
ON: indicates power is applied
Excitation current source
0.5 mA and 1.0 mA selectable per channel
Cable impedance
Maximum @ 25 Ω (operating with >25 Ω will reduce accuracy)
Power supply distance rating
6 (the module may not be more than 6 modules away from the system power supply)
Heat dissipation
1.5 total W (the W per point, plus the minimum W, with all points enabled)
Input channel configuration
Via configuration software screen or the user prog (by writing a unique bit pattern into the module’s configuration file)
Accuracy drift
At 0...55 °C ±0.026 °C/°C (0.026 °F/°F) for Pt 385, ±0.007 Ω/°C (0.012 Ω/°F) for 150 Ω range, ±0.023 °C/°C (0.023 °F/°F) for Pt 3916, ±0.023 Ω/°C (0.041 Ω/°F) for 500 Ω range, ±0.012 °C/°C (0.012 °F/°F) for Ni, ±0.043 Ω/°C (0.077 Ω/°F) for 1,000 Ω range,
Operating temperature
-20 °C
ESD immunity
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
Operating altitude
2000 m
Storage temperature
-40 °C
Operating humidity
5...95% noncondensing
A/D converter type
Delta-Sigma
Common mode rejection
>110 dB at 60 Hz (with 10 or 60 Hz filter)
Input impedance
>10 MΩ
Channel diagnostics
Over or under range or open circuit condition by bit reporting for analog inputs
Non-linearity
±0.05% (in % full scale)
Typical overall accuracy
±0.5 °C (°F) for Pt 385
Repeatability
±0.2 Ω for other resistances
Input and output group to system isolation
30V AC/30V DC working voltage type test: 500V AC or 707V DC @ 1min
Vibration
Operating: 10...500 Hz, 5 G, 0.030 in @ maximum peak-to-peak
Shock
Operating: 30 G
Shipping weight, approx
260 g
Hazardous environment class
Class I, Division 2, Hazardous Location, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
Radiated and conducted emissions
EN50081-2: Class A
Recommended cable
Belden 8761 (shielded)
Height
90 mm
Width
40 mm
Depth
87 mm
Noise immunity
NEMA standard ICS 2-230
图纸
图纸
产品图纸 图纸 (DWG)
产品图纸 图纸 (DWG)
产品图纸 图纸 (DWG)
产品图纸 图纸 (DWG)
产品图纸 图纸 (DWG)
图纸
产品图纸 图纸 (DWG)
产品图纸 图纸 (DWG)
产品图纸 图纸 (DWG)
产品图纸 图纸 (DWG)
产品图纸 图纸 (DWG)
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
Product Cutsheet 基本信息
--
Selection Guide 基本信息
1761-SG001
基本信息 出版
Product Cutsheet --
Selection Guide 1761-SG001
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
认证
  • UL Listed Hazardous

截至 2026-01-31,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。

技术说明
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
寻找最近经销商
请联系您在{0}的经销商
更改位置
EmailEmail
PhonePhone
寻找合作伙伴
MicroLogix 4 Point Module
CloseClose
1762-IR4
关闭
打印
Allen-Bradley 1762-IR4 product image
电话:
呼叫
Rockwell Automation Home
Copyright ©2026 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页
  2. Chevron LeftChevron Left 产品
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose