| Class |
Progmable Logic Controller Module
|
|---|---|
| Depth |
87
|
| Height |
90
|
| I/O Isolation |
Isolated
|
| I/O Status Indication |
LED
|
| Module Interfaces |
Resistance thermom detector input
|
| Number Of Channels |
4 point
|
| Temperature Rating |
0…55 °C (32…131 °F)
|
| Thermocouple Type |
4 Channel, RTD/Resistance Module
|
| Number of analogue inputs |
4
|
|---|---|
| Input, current |
No
|
| Input, voltage |
No
|
| Input, resistor |
Yes
|
| Input, resistance thermometer |
No
|
| Input, thermocouple |
No
|
| Input signal, configurable |
Yes
|
| Output, current |
No
|
| Output, voltage |
No
|
| Output signal configurable |
No
|
| Analogue inputs configurable |
No
|
| Analogue outputs configurable |
No
|
| Type of electric connection |
Screw connection
|
| Open-circuit detection time |
6 ms
|
| Channel to channel isolation |
±10V DC
|
| Input type |
604 Ω Nickel-Iron 518
|
| Bus current draw |
50mA @ 24V DC, maximum
|
| Fast transient burst |
IEC1000-4-4: 2kV @ 5kHz
|
| Update time |
Input filter and configuration dependent (typical)
|
| Normal mode rejection ratio |
70 dB minimum @ 60 Hz with the 10 or 60 Hz filter selected
|
| Conducted immunity |
IEC 1000-4-6: 10 V/m, 80...1000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
|
| Radiated immunity |
IEC 61000-4-3: 10 V/m, 80...1000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
|
| Calibration |
The module performs autocalibration on channel enable and on a configuration change between channels. You can also prog the module to calibrate every five minutes
|
| Typical accuracy |
At 25 ° C (77 °F) ambient with module operating temperature at 25 °C (77 °F)
|
| Resolution |
Input filter and configuration dependent
|
| Suitable for safety functions |
No
|
| Overload at input terminals |
Maximum @ ±35V DC continuous
|
| Surge immunity |
IEC1000-4-5: 1kV galvanic gun
|
| Module power LED |
ON: indicates power is applied
|
| Excitation current source |
0.5 mA and 1.0 mA selectable per channel
|
| Cable impedance |
Maximum @ 25 Ω (operating with >25 Ω will reduce accuracy)
|
| Power supply distance rating |
6 (the module may not be more than 6 modules away from the system power supply)
|
| Heat dissipation |
1.5 total W (the W per point, plus the minimum W, with all points enabled)
|
| Input channel configuration |
Via configuration software screen or the user prog (by writing a unique bit pattern into the module’s configuration file)
|
| Accuracy drift |
At 0...55 °C ±0.026 °C/°C (0.026 °F/°F) for Pt 385, ±0.007 Ω/°C (0.012 Ω/°F) for 150 Ω range, ±0.023 °C/°C (0.023 °F/°F) for Pt 3916, ±0.023 Ω/°C (0.041 Ω/°F) for 500 Ω range, ±0.012 °C/°C (0.012 °F/°F) for Ni, ±0.043 Ω/°C (0.077 Ω/°F) for 1,000 Ω range,
|
| Operating temperature |
-20 °C
|
|---|---|
| ESD immunity |
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
|
| Operating altitude |
2000 m
|
| Storage temperature |
-40 °C
|
| Operating humidity |
5...95% noncondensing
|
| A/D converter type |
Delta-Sigma
|
|---|---|
| Common mode rejection |
>110 dB at 60 Hz (with 10 or 60 Hz filter)
|
| Input impedance |
>10 MΩ
|
| Channel diagnostics |
Over or under range or open circuit condition by bit reporting for analog inputs
|
| Non-linearity |
±0.05% (in % full scale)
|
|---|---|
| Typical overall accuracy |
±0.5 °C (°F) for Pt 385
|
| Repeatability |
±0.2 Ω for other resistances
|
|---|---|
| Input and output group to system isolation |
30V AC/30V DC working voltage type test: 500V AC or 707V DC @ 1min
|
| Vibration |
Operating: 10...500 Hz, 5 G, 0.030 in @ maximum peak-to-peak
|
|---|---|
| Shock |
Operating: 30 G
|
| Shipping weight, approx |
260 g
|
| Hazardous environment class |
Class I, Division 2, Hazardous Location, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
|
|---|---|
| Radiated and conducted emissions |
EN50081-2: Class A
|
| Recommended cable |
Belden 8761 (shielded)
|
|---|---|
| Height |
90 mm
|
| Width |
40 mm
|
| Depth |
87 mm
|
| Noise immunity |
NEMA standard ICS 2-230
|
|---|
| 基本信息 | 出版 |
|---|---|
| Product Cutsheet | -- |
| Selection Guide | 1761-SG001 |
- UL Listed Hazardous
截至 2026-01-31,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。
| 技术说明 |
|---|
技术规格
| Class |
Progmable Logic Controller Module
|
|---|---|
| Depth |
87
|
| Height |
90
|
| I/O Isolation |
Isolated
|
| I/O Status Indication |
LED
|
| Module Interfaces |
Resistance thermom detector input
|
| Number Of Channels |
4 point
|
| Temperature Rating |
0…55 °C (32…131 °F)
|
| Thermocouple Type |
4 Channel, RTD/Resistance Module
|
| Number of analogue inputs |
4
|
|---|---|
| Input, current |
No
|
| Input, voltage |
No
|
| Input, resistor |
Yes
|
| Input, resistance thermometer |
No
|
| Input, thermocouple |
No
|
| Input signal, configurable |
Yes
|
| Output, current |
No
|
| Output, voltage |
No
|
| Output signal configurable |
No
|
| Analogue inputs configurable |
No
|
| Analogue outputs configurable |
No
|
| Type of electric connection |
Screw connection
|
| Open-circuit detection time |
6 ms
|
| Channel to channel isolation |
±10V DC
|
| Input type |
604 Ω Nickel-Iron 518
|
| Bus current draw |
50mA @ 24V DC, maximum
|
| Fast transient burst |
IEC1000-4-4: 2kV @ 5kHz
|
| Update time |
Input filter and configuration dependent (typical)
|
| Normal mode rejection ratio |
70 dB minimum @ 60 Hz with the 10 or 60 Hz filter selected
|
| Conducted immunity |
IEC 1000-4-6: 10 V/m, 80...1000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
|
| Radiated immunity |
IEC 61000-4-3: 10 V/m, 80...1000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
|
| Calibration |
The module performs autocalibration on channel enable and on a configuration change between channels. You can also prog the module to calibrate every five minutes
|
| Typical accuracy |
At 25 ° C (77 °F) ambient with module operating temperature at 25 °C (77 °F)
|
| Resolution |
Input filter and configuration dependent
|
| Suitable for safety functions |
No
|
| Overload at input terminals |
Maximum @ ±35V DC continuous
|
| Surge immunity |
IEC1000-4-5: 1kV galvanic gun
|
| Module power LED |
ON: indicates power is applied
|
| Excitation current source |
0.5 mA and 1.0 mA selectable per channel
|
| Cable impedance |
Maximum @ 25 Ω (operating with >25 Ω will reduce accuracy)
|
| Power supply distance rating |
6 (the module may not be more than 6 modules away from the system power supply)
|
| Heat dissipation |
1.5 total W (the W per point, plus the minimum W, with all points enabled)
|
| Input channel configuration |
Via configuration software screen or the user prog (by writing a unique bit pattern into the module’s configuration file)
|
| Accuracy drift |
At 0...55 °C ±0.026 °C/°C (0.026 °F/°F) for Pt 385, ±0.007 Ω/°C (0.012 Ω/°F) for 150 Ω range, ±0.023 °C/°C (0.023 °F/°F) for Pt 3916, ±0.023 Ω/°C (0.041 Ω/°F) for 500 Ω range, ±0.012 °C/°C (0.012 °F/°F) for Ni, ±0.043 Ω/°C (0.077 Ω/°F) for 1,000 Ω range,
|
| Operating temperature |
-20 °C
|
|---|---|
| ESD immunity |
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
|
| Operating altitude |
2000 m
|
| Storage temperature |
-40 °C
|
| Operating humidity |
5...95% noncondensing
|
| A/D converter type |
Delta-Sigma
|
|---|---|
| Common mode rejection |
>110 dB at 60 Hz (with 10 or 60 Hz filter)
|
| Input impedance |
>10 MΩ
|
| Channel diagnostics |
Over or under range or open circuit condition by bit reporting for analog inputs
|
| Non-linearity |
±0.05% (in % full scale)
|
|---|---|
| Typical overall accuracy |
±0.5 °C (°F) for Pt 385
|
| Repeatability |
±0.2 Ω for other resistances
|
|---|---|
| Input and output group to system isolation |
30V AC/30V DC working voltage type test: 500V AC or 707V DC @ 1min
|
| Vibration |
Operating: 10...500 Hz, 5 G, 0.030 in @ maximum peak-to-peak
|
|---|---|
| Shock |
Operating: 30 G
|
| Shipping weight, approx |
260 g
|
| Hazardous environment class |
Class I, Division 2, Hazardous Location, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
|
|---|---|
| Radiated and conducted emissions |
EN50081-2: Class A
|
| Recommended cable |
Belden 8761 (shielded)
|
|---|---|
| Height |
90 mm
|
| Width |
40 mm
|
| Depth |
87 mm
|
| Noise immunity |
NEMA standard ICS 2-230
|
|---|
图纸
文档
|
Product Cutsheet
基本信息
-- |
|
Selection Guide
基本信息
1761-SG001 |
| 基本信息 | 出版 |
|---|---|
| Product Cutsheet | -- |
| Selection Guide | 1761-SG001 |
认证
- UL Listed Hazardous
截至 2026-01-31,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。
技术说明
| 技术说明 |
|---|
Copyright ©2026 Rockwell Automation, Inc.