analog input modules | 4 Channel Current/Voltage Analog Input Module |
---|---|
Class | Progmable Logic Controller Module |
Current Range | 4-20 |
Depth | 87 |
Height | 90 |
I/O Isolation | Isolated |
I/O Status Indication | LED |
Module Interfaces | Analog input |
Number Of Channels | 4 point |
Temperature Rating | -20…65 °C (-4…149 °F) |
Resolution of the analogue inputs | 15 bit |
---|---|
Input, current | True |
Input, voltage | True |
Input, resistor | False |
Input, resistance thermometer | False |
Input, thermocouple | False |
Input signal, configurable | True |
Output, current | False |
Output, voltage | False |
Output signal configurable | False |
Analogue inputs configurable | True |
Analogue outputs configurable | False |
Type of electric connection | Screw connection |
Fast transient burst | IEC1000-4-4: 2kV @ 5kHz |
Conducted immunity | 10V @ 0.15...80MHz |
Radiated immunity | IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier |
Surge immunity | IEC1000-4-5: 1kV galvanic gun |
Module power LED | On: indicates power is applied |
Operating temperature | -20 °C |
---|---|
ESD immunity | EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect |
Operating altitude | 2000 m |
Storage temperature | -40 °C |
Operating humidity | 5...95% noncondensing |
Common mode voltage range | -27 to 27V |
---|---|
A/D converter type | Successive approximation |
Number of inputs | 4 differential (bipolar) |
Common mode rejection | >55 dB at 50 and 60 Hz |
Input update time | Typical: 130, 250, 290, 450, 530 ms (selectable) |
Input impedance | Voltage Terminal: 200 KΩ |
Current input protection | -32 mA |
Voltage input protection | -30 V |
Channel diagnostics | Over or under range or open circuit condition by bit reporting for analog inputs |
Analog normal operating range | Voltage: -10...10V DC |
---|---|
Bus current draw, max | 40mA @ 5V DC, 50mA @ 24V DC |
Full scale analog ranges | Voltage: -10.5...10.5V DC, Current: -21...21 mA |
Repeatability | -0.12 to 0.12% |
Input and output group to system isolation | 30V AC/30V DC rated working voltage (N.E.C. Class 2 required) (IEC Class 2 reinforced insulation) type test: 500V AC or 707V DC @ 1min |
Height | 90 mm |
---|---|
Width | 40 mm |
Depth | 87 mm |
Recommended cable | Belden 8761 (shielded), (For 1762-IT4, shielded thermocouple extension wire for the specific type of thermocouple you are using. Follow thermocouple manufacturer’s recommendations.) |
Non-linearity | ±0.12% (in % full scale) |
---|---|
Typical overall accuracy | ±0.32% full scale @ -20...65 °C, ±0.24% full scale @ 25 °C |
Weight | Shipping: 240 g (0.53 lbs.) approximately (with cartoon) |
---|---|
Vibration | Operating: 5 g @ 10...500 Hz, 0.030 in. max. peak-to-peak |
Shock | Operating: 30 g |
Hazardous environment class | Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213) |
---|---|
Radiated and conducted emissions | EN50081-2: Class A |
Sales Info
Repairable | NOT_REPAIRABLE |
Preferred Availability | false |
Quick Turnaround | false |
Dimension Height | 5.207 |
Lead Time | 5 |
Dimension Width | 16.891 |
Dimension Length | 10.897 |
Stock Status | NON_STOCKED |
Weight | 0.186 |
Weight Unit | KG |
Dimension Unit | CM |
Drawings | |
---|---|
Product Drawing | Drawing (DWG) |
Drawings |
---|
Product Drawing Drawing (DWG) |
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
类型 | 资源 | 发布 |
---|---|---|
General | Selection Guide | 1761-SG001 |
General | Product Cutsheet | -- |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
- UL Listed Hazardous
- UL Listed
This product was certified with the above certifications as of 2025-06-16. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Technical Specifications
analog input modules | 4 Channel Current/Voltage Analog Input Module |
---|---|
Class | Progmable Logic Controller Module |
Current Range | 4-20 |
Depth | 87 |
Height | 90 |
I/O Isolation | Isolated |
I/O Status Indication | LED |
Module Interfaces | Analog input |
Number Of Channels | 4 point |
Temperature Rating | -20…65 °C (-4…149 °F) |
Resolution of the analogue inputs | 15 bit |
---|---|
Input, current | True |
Input, voltage | True |
Input, resistor | False |
Input, resistance thermometer | False |
Input, thermocouple | False |
Input signal, configurable | True |
Output, current | False |
Output, voltage | False |
Output signal configurable | False |
Analogue inputs configurable | True |
Analogue outputs configurable | False |
Type of electric connection | Screw connection |
Fast transient burst | IEC1000-4-4: 2kV @ 5kHz |
Conducted immunity | 10V @ 0.15...80MHz |
Radiated immunity | IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier |
Surge immunity | IEC1000-4-5: 1kV galvanic gun |
Module power LED | On: indicates power is applied |
Operating temperature | -20 °C |
---|---|
ESD immunity | EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect |
Operating altitude | 2000 m |
Storage temperature | -40 °C |
Operating humidity | 5...95% noncondensing |
Common mode voltage range | -27 to 27V |
---|---|
A/D converter type | Successive approximation |
Number of inputs | 4 differential (bipolar) |
Common mode rejection | >55 dB at 50 and 60 Hz |
Input update time | Typical: 130, 250, 290, 450, 530 ms (selectable) |
Input impedance | Voltage Terminal: 200 KΩ |
Current input protection | -32 mA |
Voltage input protection | -30 V |
Channel diagnostics | Over or under range or open circuit condition by bit reporting for analog inputs |
Analog normal operating range | Voltage: -10...10V DC |
---|---|
Bus current draw, max | 40mA @ 5V DC, 50mA @ 24V DC |
Full scale analog ranges | Voltage: -10.5...10.5V DC, Current: -21...21 mA |
Repeatability | -0.12 to 0.12% |
Input and output group to system isolation | 30V AC/30V DC rated working voltage (N.E.C. Class 2 required) (IEC Class 2 reinforced insulation) type test: 500V AC or 707V DC @ 1min |
Height | 90 mm |
---|---|
Width | 40 mm |
Depth | 87 mm |
Recommended cable | Belden 8761 (shielded), (For 1762-IT4, shielded thermocouple extension wire for the specific type of thermocouple you are using. Follow thermocouple manufacturer’s recommendations.) |
Non-linearity | ±0.12% (in % full scale) |
---|---|
Typical overall accuracy | ±0.32% full scale @ -20...65 °C, ±0.24% full scale @ 25 °C |
Weight | Shipping: 240 g (0.53 lbs.) approximately (with cartoon) |
---|---|
Vibration | Operating: 5 g @ 10...500 Hz, 0.030 in. max. peak-to-peak |
Shock | Operating: 30 g |
Hazardous environment class | Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213) |
---|---|
Radiated and conducted emissions | EN50081-2: Class A |
Sales Info
Repairable | NOT_REPAIRABLE |
Preferred Availability | false |
Quick Turnaround | false |
Dimension Height | 5.207 |
Lead Time | 5 |
Dimension Width | 16.891 |
Dimension Length | 10.897 |
Stock Status | NON_STOCKED |
Weight | 0.186 |
Weight Unit | KG |
Dimension Unit | CM |
Drawings
Drawings | |
---|---|
Product Drawing | Drawing (DWG) |
Drawings |
---|
Product Drawing Drawing (DWG) |
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
文档
Selection Guide
General
1761-SG001 |
Product Cutsheet
General
-- |
类型 | 资源 | 发布 |
---|---|---|
General | Selection Guide | 1761-SG001 |
General | Product Cutsheet | -- |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
认证
- UL Listed Hazardous
- UL Listed
This product was certified with the above certifications as of 2025-06-16. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Loading


Copyright ©2025 Rockwell Automation, Inc.