| analog input modules | 4 Channel Current/Voltage Analog Input Module |
|---|---|
| Class | Progmable Logic Controller Module |
| Current Range | 4-20 |
| Depth | 87 |
| Height | 90 |
| I/O Isolation | Isolated |
| I/O Status Indication | LED |
| Module Interfaces | Analog input |
| Number Of Channels | 4 point |
| Temperature Rating | -20…65 °C (-4…149 °F) |
| Resolution of the analogue inputs | 15 bit |
|---|---|
| Input, current | True |
| Input, voltage | True |
| Input, resistor | False |
| Input, resistance thermometer | False |
| Input, thermocouple | False |
| Input signal, configurable | True |
| Output, current | False |
| Output, voltage | False |
| Output signal configurable | False |
| Analogue inputs configurable | True |
| Analogue outputs configurable | False |
| Type of electric connection | Screw connection |
| Fast transient burst | IEC1000-4-4: 2kV @ 5kHz |
| Conducted immunity | 10V @ 0.15...80MHz |
| Radiated immunity | IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier |
| Surge immunity | IEC1000-4-5: 1kV galvanic gun |
| Module power LED | On: indicates power is applied |
| Operating temperature | -20 °C |
|---|---|
| ESD immunity | EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect |
| Operating altitude | 2000 m |
| Storage temperature | -40 °C |
| Operating humidity | 5...95% noncondensing |
| Common mode voltage range | -27 to 27V |
|---|---|
| A/D converter type | Successive approximation |
| Number of inputs | 4 differential (bipolar) |
| Common mode rejection | >55 dB at 50 and 60 Hz |
| Input update time | Typical: 130, 250, 290, 450, 530 ms (selectable) |
| Input impedance | Voltage Terminal: 200 KΩ |
| Current input protection | -32 mA |
| Voltage input protection | -30 V |
| Channel diagnostics | Over or under range or open circuit condition by bit reporting for analog inputs |
| Analog normal operating range | Voltage: -10...10V DC |
|---|---|
| Bus current draw, max | 40mA @ 5V DC, 50mA @ 24V DC |
| Full scale analog ranges | Voltage: -10.5...10.5V DC, Current: -21...21 mA |
| Repeatability | -0.12 to 0.12% |
| Input and output group to system isolation | 30V AC/30V DC rated working voltage (N.E.C. Class 2 required) (IEC Class 2 reinforced insulation) type test: 500V AC or 707V DC @ 1min |
| Height | 90 mm |
|---|---|
| Width | 40 mm |
| Depth | 87 mm |
| Recommended cable | Belden 8761 (shielded), (For 1762-IT4, shielded thermocouple extension wire for the specific type of thermocouple you are using. Follow thermocouple manufacturer’s recommendations.) |
| Non-linearity | ±0.12% (in % full scale) |
|---|---|
| Typical overall accuracy | ±0.32% full scale @ -20...65 °C, ±0.24% full scale @ 25 °C |
| Weight | Shipping: 240 g (0.53 lbs.) approximately (with cartoon) |
|---|---|
| Vibration | Operating: 5 g @ 10...500 Hz, 0.030 in. max. peak-to-peak |
| Shock | Operating: 30 g |
| Hazardous environment class | Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213) |
|---|---|
| Radiated and conducted emissions | EN50081-2: Class A |
| 图纸 | |
|---|---|
| Product Drawing | Drawing (DWG) |
| 图纸 |
|---|
| Product Drawing Drawing (DWG) |
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
| 类型 | 资源 | 出版 |
|---|---|---|
| General | Selection Guide | 1761-SG001 |
| General | Product Cutsheet | -- |
- UL Listed Hazardous
- UL Listed
This product was certified with the above certifications as of 2025-07-20. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
技术规格
| analog input modules | 4 Channel Current/Voltage Analog Input Module |
|---|---|
| Class | Progmable Logic Controller Module |
| Current Range | 4-20 |
| Depth | 87 |
| Height | 90 |
| I/O Isolation | Isolated |
| I/O Status Indication | LED |
| Module Interfaces | Analog input |
| Number Of Channels | 4 point |
| Temperature Rating | -20…65 °C (-4…149 °F) |
| Resolution of the analogue inputs | 15 bit |
|---|---|
| Input, current | True |
| Input, voltage | True |
| Input, resistor | False |
| Input, resistance thermometer | False |
| Input, thermocouple | False |
| Input signal, configurable | True |
| Output, current | False |
| Output, voltage | False |
| Output signal configurable | False |
| Analogue inputs configurable | True |
| Analogue outputs configurable | False |
| Type of electric connection | Screw connection |
| Fast transient burst | IEC1000-4-4: 2kV @ 5kHz |
| Conducted immunity | 10V @ 0.15...80MHz |
| Radiated immunity | IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier |
| Surge immunity | IEC1000-4-5: 1kV galvanic gun |
| Module power LED | On: indicates power is applied |
| Operating temperature | -20 °C |
|---|---|
| ESD immunity | EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect |
| Operating altitude | 2000 m |
| Storage temperature | -40 °C |
| Operating humidity | 5...95% noncondensing |
| Common mode voltage range | -27 to 27V |
|---|---|
| A/D converter type | Successive approximation |
| Number of inputs | 4 differential (bipolar) |
| Common mode rejection | >55 dB at 50 and 60 Hz |
| Input update time | Typical: 130, 250, 290, 450, 530 ms (selectable) |
| Input impedance | Voltage Terminal: 200 KΩ |
| Current input protection | -32 mA |
| Voltage input protection | -30 V |
| Channel diagnostics | Over or under range or open circuit condition by bit reporting for analog inputs |
| Analog normal operating range | Voltage: -10...10V DC |
|---|---|
| Bus current draw, max | 40mA @ 5V DC, 50mA @ 24V DC |
| Full scale analog ranges | Voltage: -10.5...10.5V DC, Current: -21...21 mA |
| Repeatability | -0.12 to 0.12% |
| Input and output group to system isolation | 30V AC/30V DC rated working voltage (N.E.C. Class 2 required) (IEC Class 2 reinforced insulation) type test: 500V AC or 707V DC @ 1min |
| Height | 90 mm |
|---|---|
| Width | 40 mm |
| Depth | 87 mm |
| Recommended cable | Belden 8761 (shielded), (For 1762-IT4, shielded thermocouple extension wire for the specific type of thermocouple you are using. Follow thermocouple manufacturer’s recommendations.) |
| Non-linearity | ±0.12% (in % full scale) |
|---|---|
| Typical overall accuracy | ±0.32% full scale @ -20...65 °C, ±0.24% full scale @ 25 °C |
| Weight | Shipping: 240 g (0.53 lbs.) approximately (with cartoon) |
|---|---|
| Vibration | Operating: 5 g @ 10...500 Hz, 0.030 in. max. peak-to-peak |
| Shock | Operating: 30 g |
| Hazardous environment class | Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213) |
|---|---|
| Radiated and conducted emissions | EN50081-2: Class A |
图纸
| 图纸 | |
|---|---|
| Product Drawing | Drawing (DWG) |
| 图纸 |
|---|
| Product Drawing Drawing (DWG) |
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
|
Selection Guide
General
1761-SG001 |
|
Product Cutsheet
General
-- |
| 类型 | 资源 | 出版 |
|---|---|---|
| General | Selection Guide | 1761-SG001 |
| General | Product Cutsheet | -- |
认证
- UL Listed Hazardous
- UL Listed
This product was certified with the above certifications as of 2025-07-20. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
技术说明
Loading
Copyright ©2025 Rockwell Automation, Inc.