Loading
Chevron UpChevron Up
Allen-Bradley 1756-EN2TR product image
Allen-Bradley 1756-EN2TR product image
Chevron DownChevron Down
Allen-Bradley 1756-EN2TR product image
Allen Bradley

CLX ENet/IP 100M DLR

PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Catalog #: 1756-EN2TR
Lifecycle status: Active
Allen-Bradley 1756-EN2TR product image
Allen-Bradley 1756-EN2TR product image
Allen-Bradley 1756-EN2TR product image
Allen Bradley
PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Lifecycle status: Active
Add to BoM
  • Register Product
  • Add to Repair Quote
  • Get Support
Technical Specifications
Drawings
Documents
Certifications
Alternative Products
Technotes
Communication Ethernet/IP
With optical interface False
Supporting protocol for TCP/IP True
Supporting protocol for DeviceNet False
Supporting protocol for other bus systems False
Redundancy True
IO link master False
Supporting protocol for DeviceNet Safety False
Supporting protocol for EtherNet/IP True
Power dissipation 5.1 W
Thermal dissipation 17.4 btu/h
Enclosure type rating None (open-style)
Ethernet ports 2 Ethernet RJ45 Category 5
CIP unconnected messages 128 + 128 (backplane + Ethernet)
Current draw 1A @ 5.1V DC, 3mA @ 24V DC
Ethernet cable 802.3 compliant shielded or unshielded twisted pair
Wiring category 2 - on Ethernet ports, 3 - on USB ports
Communication rate 10/100 Mbps
Connections supported, max TCP: 128, CIP: 256 (CIP connections can be used for all explicit or all implicit applications. for exAle, a 1756-ENBT module has a total of 128 CIP connections that can be used for any combination of connections.)
Isolation voltage 30V (continuous), Basic Insulation Type, Ethernet to Backplane, USB to Backplane, and USB to Ethernet(Applies only to these modules/series: 1756-EN2T/D, 1756-EN2TR/C,1756-EN3TR/B), Type tested at 980V AC @ 60s
Supporting protocol for LON False
Supporting protocol for ASI False
Supporting protocol for PROFIBUS False
Supporting protocol for CAN False
Supporting protocol for INTERBUS False
Supporting protocol for KNX False
Supporting protocol for Modbus False
Supporting protocol for Data-Highway False
Supporting protocol for SUCONET False
With potential separation False
Supporting protocol for SERCOS False
Supporting protocol for INTERBUS-Safety False
Radio standard Bluetooth False
Radio standard Wi-Fi 802.11 False
Supporting protocol for AS-Interface Safety at Work False
Supporting protocol for Foundation Fieldbus False
Supporting protocol for PROFINET CBA False
Supporting protocol for PROFINET IO False
Supporting protocol for PROFIsafe False
Supporting protocol for SafetyBUS p False
Radio standard GPRS False
Radio standard GSM False
Radio standard UMTS False
Slot width 1
ATEX temp code T4
Surrounding air temperature, max 60 °C
Storage temperature -40 °C <Ta <85 °C (-40 °F <Ta <185 °F)
Emissions CISPR 11: Class A
Vibration 2 G @ 10...500 Hz
ESD immunity 6 kV contact discharges, 8 kV air discharges
EFT/B immunity ±3kV @ 5kHz on Ethernet ports
Relative humidity 5...95% noncondensing
Shock Operating: 30 G, Nonoperating: 30 G
Conducted RF immunity 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunity ±2 kV line-earth (CM) on Ethernet ports
Operating temperature 0 °C <Ta <60 °C (32 °F <Ta <140 °F)
Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3V/m with 1 kHz sine-wave 80% AM from 2000...6000 MHz
North American temperature code T4A
IECEx temperature code T4
Module location Chassis based, any slot
Sales Info
Repairable REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 5.461
Lead Time 22
Dimension Width 24.003
Dimension Length 19.05
Stock Status NON_STOCKED
Weight 0.483
Weight Unit KG
Dimension Unit CM
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Dimensional Drawing in 3D (PDF) Download (PDF)
Product Drawing Drawing (DXF)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Dimensional Drawing in 3D (PDF) Download (PDF)
Product Drawing Drawing (DXF)
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
类型 资源 发布
General Selection Guide 1756-SG001
General Product Profile --
General Installation Instructions 1756-IN050
General Product Cutsheet --
Installation Instructions enet-in002_-en-p ENET-IN002
Technical Data 1756-td003_-en-e 1756-TD003
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library Chevron RightChevron Right
China CCC ATEX Australian RCM IECEx Scheme Korean KC UL Listed
  • China CCC
  • American Bureau of Shippin
  • ODVA
  • Safety
  • ATEX
  • CE
  • Australian RCM
  • IECEx Scheme
  • FM Approved Haz
  • Korean KC
  • Registro Italiano Navale
  • UL Listed
  • UL Listed Hazardous

This product was certified with the above certifications as of 2025-05-23. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

每页条目数:
1-1 的 1
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Technical Specifications
Communication Ethernet/IP
With optical interface False
Supporting protocol for TCP/IP True
Supporting protocol for DeviceNet False
Supporting protocol for other bus systems False
Redundancy True
IO link master False
Supporting protocol for DeviceNet Safety False
Supporting protocol for EtherNet/IP True
Power dissipation 5.1 W
Thermal dissipation 17.4 btu/h
Enclosure type rating None (open-style)
Ethernet ports 2 Ethernet RJ45 Category 5
CIP unconnected messages 128 + 128 (backplane + Ethernet)
Current draw 1A @ 5.1V DC, 3mA @ 24V DC
Ethernet cable 802.3 compliant shielded or unshielded twisted pair
Wiring category 2 - on Ethernet ports, 3 - on USB ports
Communication rate 10/100 Mbps
Connections supported, max TCP: 128, CIP: 256 (CIP connections can be used for all explicit or all implicit applications. for exAle, a 1756-ENBT module has a total of 128 CIP connections that can be used for any combination of connections.)
Isolation voltage 30V (continuous), Basic Insulation Type, Ethernet to Backplane, USB to Backplane, and USB to Ethernet(Applies only to these modules/series: 1756-EN2T/D, 1756-EN2TR/C,1756-EN3TR/B), Type tested at 980V AC @ 60s
Supporting protocol for LON False
Supporting protocol for ASI False
Supporting protocol for PROFIBUS False
Supporting protocol for CAN False
Supporting protocol for INTERBUS False
Supporting protocol for KNX False
Supporting protocol for Modbus False
Supporting protocol for Data-Highway False
Supporting protocol for SUCONET False
With potential separation False
Supporting protocol for SERCOS False
Supporting protocol for INTERBUS-Safety False
Radio standard Bluetooth False
Radio standard Wi-Fi 802.11 False
Supporting protocol for AS-Interface Safety at Work False
Supporting protocol for Foundation Fieldbus False
Supporting protocol for PROFINET CBA False
Supporting protocol for PROFINET IO False
Supporting protocol for PROFIsafe False
Supporting protocol for SafetyBUS p False
Radio standard GPRS False
Radio standard GSM False
Radio standard UMTS False
Slot width 1
ATEX temp code T4
Surrounding air temperature, max 60 °C
Storage temperature -40 °C <Ta <85 °C (-40 °F <Ta <185 °F)
Emissions CISPR 11: Class A
Vibration 2 G @ 10...500 Hz
ESD immunity 6 kV contact discharges, 8 kV air discharges
EFT/B immunity ±3kV @ 5kHz on Ethernet ports
Relative humidity 5...95% noncondensing
Shock Operating: 30 G, Nonoperating: 30 G
Conducted RF immunity 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunity ±2 kV line-earth (CM) on Ethernet ports
Operating temperature 0 °C <Ta <60 °C (32 °F <Ta <140 °F)
Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3V/m with 1 kHz sine-wave 80% AM from 2000...6000 MHz
North American temperature code T4A
IECEx temperature code T4
Module location Chassis based, any slot
Sales Info
Repairable REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 5.461
Lead Time 22
Dimension Width 24.003
Dimension Length 19.05
Stock Status NON_STOCKED
Weight 0.483
Weight Unit KG
Dimension Unit CM
Drawings
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Dimensional Drawing in 3D (PDF) Download (PDF)
Product Drawing Drawing (DXF)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Dimensional Drawing in 3D (PDF) Download (PDF)
Product Drawing Drawing (DXF)
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
文档
Selection Guide General
1756-SG001
Product Profile General
--
Installation Instructions General
1756-IN050
Product Cutsheet General
--
enet-in002_-en-p Installation Instructions
ENET-IN002
1756-td003_-en-e Technical Data
1756-TD003
类型 资源 发布
General Selection Guide 1756-SG001
General Product Profile --
General Installation Instructions 1756-IN050
General Product Cutsheet --
Installation Instructions enet-in002_-en-p ENET-IN002
Technical Data 1756-td003_-en-e 1756-TD003
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library Chevron RightChevron Right
认证
China CCC ATEX Australian RCM IECEx Scheme Korean KC UL Listed
  • China CCC
  • American Bureau of Shippin
  • ODVA
  • Safety
  • ATEX
  • CE
  • Australian RCM
  • IECEx Scheme
  • FM Approved Haz
  • Korean KC
  • Registro Italiano Navale
  • UL Listed
  • UL Listed Hazardous

This product was certified with the above certifications as of 2025-05-23. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Alternative Products
每页条目数:
1-1 的 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Loading
Find your nearest distributor
Change location
EmailEmail
PhonePhone
Find a partner Chevron RightChevron Right
CLX ENet/IP 100M DLR
CloseClose
1756-EN2TR
关闭
打印
Chevron LeftChevron Left
Allen-Bradley 1756-EN2TR product image
Chevron RightChevron Right
Chevron LeftChevron Left
Allen-Bradley 1756-EN2TR product image
Allen-Bradley 1756-EN2TR product image
Chevron RightChevron Right
手机:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页 Chevron RightChevron Right
  2. Chevron LeftChevron Left 产品 Chevron RightChevron Right
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose