| Communication |
Ethernet/IP
|
|---|
| With optical interface |
False
|
|---|---|
| Supporting protocol for TCP/IP |
True
|
| Supporting protocol for DeviceNet |
False
|
| Supporting protocol for other bus systems |
False
|
| Redundancy |
True
|
| IO link master |
False
|
| Supporting protocol for DeviceNet Safety |
False
|
| Supporting protocol for EtherNet/IP |
True
|
| Power dissipation |
5.1 W
|
| Thermal dissipation |
17.4 btu/h
|
| Enclosure type rating |
None (open-style)
|
| Ethernet ports |
2 Ethernet RJ45 Category 5
|
| CIP unconnected messages |
128 + 128 (backplane + Ethernet)
|
| Current draw |
1A @ 5.1V DC, 3mA @ 24V DC
|
| Ethernet cable |
802.3 compliant shielded or unshielded twisted pair
|
| Wiring category |
2 - on Ethernet ports, 3 - on USB ports
|
| Communication rate |
10/100 Mbps
|
| Connections supported, max |
TCP: 128, CIP: 256 (CIP connections can be used for all explicit or all implicit applications. for exAle, a 1756-ENBT module has a total of 128 CIP connections that can be used for any combination of connections.)
|
| Isolation voltage |
30V (continuous), Basic Insulation Type, Ethernet to Backplane, USB to Backplane, and USB to Ethernet(Applies only to these modules/series: 1756-EN2T/D, 1756-EN2TR/C,1756-EN3TR/B), Type tested at 980V AC @ 60s
|
| Supporting protocol for LON |
False
|
| Supporting protocol for ASI |
False
|
| Supporting protocol for PROFIBUS |
False
|
| Supporting protocol for CAN |
False
|
| Supporting protocol for INTERBUS |
False
|
| Supporting protocol for KNX |
False
|
| Supporting protocol for Modbus |
False
|
| Supporting protocol for Data-Highway |
False
|
| Supporting protocol for SUCONET |
False
|
| With potential separation |
False
|
| Supporting protocol for SERCOS |
False
|
| Supporting protocol for INTERBUS-Safety |
False
|
| Radio standard Bluetooth |
False
|
| Radio standard Wi-Fi 802.11 |
False
|
| Supporting protocol for AS-Interface Safety at Work |
False
|
| Supporting protocol for Foundation Fieldbus |
False
|
| Supporting protocol for PROFINET CBA |
False
|
| Supporting protocol for PROFINET IO |
False
|
| Supporting protocol for PROFIsafe |
False
|
| Supporting protocol for SafetyBUS p |
False
|
| Radio standard GPRS |
False
|
| Radio standard GSM |
False
|
| Radio standard UMTS |
False
|
| Slot width |
1
|
| ATEX temp code |
T4
|
| Surrounding air temperature, max |
60 °C
|
|---|---|
| Storage temperature |
-40 °C <85 °C (-40 °F <185 °F)
|
| Emissions |
CISPR 11: Class A
|
| Vibration |
2 G @ 10...500 Hz
|
| ESD immunity |
6 kV contact discharges, 8 kV air discharges
|
| EFT/B immunity |
±3kV @ 5kHz on Ethernet ports
|
| Relative humidity |
5...95% noncondensing
|
| Shock |
Operating: 30 G, Nonoperating: 30 G
|
| Conducted RF immunity |
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
|
| Surge transient immunity |
±2 kV line-earth (CM) on Ethernet ports
|
| Operating temperature |
0 °C <60 °C (32 °F <140 °F)
|
| Radiated RF immunity |
10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3V/m with 1 kHz sine-wave 80% AM from 2000...6000 MHz
|
| North American temperature code |
T4A
|
|---|---|
| IECEx temperature code |
T4
|
| Module location |
Chassis based, any slot
|
|---|
| 图纸 | |
|---|---|
| 3-Dimensional STEP model (STP) | Download (ZIP) |
| Dimensional Drawing in 3D (PDF) | Download (PDF) |
| Product Drawing | Drawing (DXF) |
| 图纸 |
|---|
| 3-Dimensional STEP model (STP) Download (ZIP) |
| Dimensional Drawing in 3D (PDF) Download (PDF) |
| Product Drawing Drawing (DXF) |
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
| 类型 | 资源 | 出版 |
|---|---|---|
| General | Product Profile | -- |
| General | Selection Guide | 1756-SG001 |
| General | Installation Instructions | 1756-IN050 |
| General | Product Cutsheet | -- |
| Installation Instructions | enet-in002_-en-p | ENET-IN002 |
| Technical Data | 1756-td003_-en-e | 1756-TD003 |
- China CCC
- American Bureau of Shippin
- ODVA
- Safety
- ATEX
- CE
- Australian RCM
- IECEx Scheme
- FM Approved Haz
- Korean KC
- Registro Italiano Navale
- UL Listed
- UL Listed Hazardous
- MOROCCO DOC
- UK EX CERTIFICATE
- UKCA DOC
This product was certified with the above certifications as of 2025-09-08. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
技术规格
| Communication |
Ethernet/IP
|
|---|
| With optical interface |
False
|
|---|---|
| Supporting protocol for TCP/IP |
True
|
| Supporting protocol for DeviceNet |
False
|
| Supporting protocol for other bus systems |
False
|
| Redundancy |
True
|
| IO link master |
False
|
| Supporting protocol for DeviceNet Safety |
False
|
| Supporting protocol for EtherNet/IP |
True
|
| Power dissipation |
5.1 W
|
| Thermal dissipation |
17.4 btu/h
|
| Enclosure type rating |
None (open-style)
|
| Ethernet ports |
2 Ethernet RJ45 Category 5
|
| CIP unconnected messages |
128 + 128 (backplane + Ethernet)
|
| Current draw |
1A @ 5.1V DC, 3mA @ 24V DC
|
| Ethernet cable |
802.3 compliant shielded or unshielded twisted pair
|
| Wiring category |
2 - on Ethernet ports, 3 - on USB ports
|
| Communication rate |
10/100 Mbps
|
| Connections supported, max |
TCP: 128, CIP: 256 (CIP connections can be used for all explicit or all implicit applications. for exAle, a 1756-ENBT module has a total of 128 CIP connections that can be used for any combination of connections.)
|
| Isolation voltage |
30V (continuous), Basic Insulation Type, Ethernet to Backplane, USB to Backplane, and USB to Ethernet(Applies only to these modules/series: 1756-EN2T/D, 1756-EN2TR/C,1756-EN3TR/B), Type tested at 980V AC @ 60s
|
| Supporting protocol for LON |
False
|
| Supporting protocol for ASI |
False
|
| Supporting protocol for PROFIBUS |
False
|
| Supporting protocol for CAN |
False
|
| Supporting protocol for INTERBUS |
False
|
| Supporting protocol for KNX |
False
|
| Supporting protocol for Modbus |
False
|
| Supporting protocol for Data-Highway |
False
|
| Supporting protocol for SUCONET |
False
|
| With potential separation |
False
|
| Supporting protocol for SERCOS |
False
|
| Supporting protocol for INTERBUS-Safety |
False
|
| Radio standard Bluetooth |
False
|
| Radio standard Wi-Fi 802.11 |
False
|
| Supporting protocol for AS-Interface Safety at Work |
False
|
| Supporting protocol for Foundation Fieldbus |
False
|
| Supporting protocol for PROFINET CBA |
False
|
| Supporting protocol for PROFINET IO |
False
|
| Supporting protocol for PROFIsafe |
False
|
| Supporting protocol for SafetyBUS p |
False
|
| Radio standard GPRS |
False
|
| Radio standard GSM |
False
|
| Radio standard UMTS |
False
|
| Slot width |
1
|
| ATEX temp code |
T4
|
| Surrounding air temperature, max |
60 °C
|
|---|---|
| Storage temperature |
-40 °C <85 °C (-40 °F <185 °F)
|
| Emissions |
CISPR 11: Class A
|
| Vibration |
2 G @ 10...500 Hz
|
| ESD immunity |
6 kV contact discharges, 8 kV air discharges
|
| EFT/B immunity |
±3kV @ 5kHz on Ethernet ports
|
| Relative humidity |
5...95% noncondensing
|
| Shock |
Operating: 30 G, Nonoperating: 30 G
|
| Conducted RF immunity |
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
|
| Surge transient immunity |
±2 kV line-earth (CM) on Ethernet ports
|
| Operating temperature |
0 °C <60 °C (32 °F <140 °F)
|
| Radiated RF immunity |
10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3V/m with 1 kHz sine-wave 80% AM from 2000...6000 MHz
|
| North American temperature code |
T4A
|
|---|---|
| IECEx temperature code |
T4
|
| Module location |
Chassis based, any slot
|
|---|
图纸
| 图纸 | |
|---|---|
| 3-Dimensional STEP model (STP) | Download (ZIP) |
| Dimensional Drawing in 3D (PDF) | Download (PDF) |
| Product Drawing | Drawing (DXF) |
| 图纸 |
|---|
| 3-Dimensional STEP model (STP) Download (ZIP) |
| Dimensional Drawing in 3D (PDF) Download (PDF) |
| Product Drawing Drawing (DXF) |
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
|
Product Profile
General
-- |
|
Selection Guide
General
1756-SG001 |
|
Installation Instructions
General
1756-IN050 |
|
Product Cutsheet
General
-- |
|
enet-in002_-en-p
Installation Instructions
ENET-IN002 |
|
1756-td003_-en-e
Technical Data
1756-TD003 |
| 类型 | 资源 | 出版 |
|---|---|---|
| General | Product Profile | -- |
| General | Selection Guide | 1756-SG001 |
| General | Installation Instructions | 1756-IN050 |
| General | Product Cutsheet | -- |
| Installation Instructions | enet-in002_-en-p | ENET-IN002 |
| Technical Data | 1756-td003_-en-e | 1756-TD003 |
认证
- China CCC
- American Bureau of Shippin
- ODVA
- Safety
- ATEX
- CE
- Australian RCM
- IECEx Scheme
- FM Approved Haz
- Korean KC
- Registro Italiano Navale
- UL Listed
- UL Listed Hazardous
- MOROCCO DOC
- UK EX CERTIFICATE
- UKCA DOC
This product was certified with the above certifications as of 2025-09-08. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
替代产品
技术说明
Loading
Copyright ©2025 Rockwell Automation, Inc.