生命周期状态: 活跃
Product at a glance
Build America, Buy America Build America, Buy America
Repair Options Available
Product Registration
生命周期状态: 活跃
Product at a glance
Build America, Buy America Build America, Buy America
Repair Options Available
Product Registration
添加到BoM
  • 注册产品
  • 寻找支持
Technical Specifications
Drawings
Documents
Certifications
Alternative Products
Technotes
Communication
Ethernet/IP
Interface
1 Copper RJ45 (10/100 Mbps)
Number Of Channels
1
With optical interface
False
Supporting protocol for TCP/IP
True
Supporting protocol for DeviceNet
False
Supporting protocol for other bus systems
False
Redundancy
False
IO link master
False
Supporting protocol for DeviceNet Safety
False
Supporting protocol for EtherNet/IP
True
Power dissipation
5.1 W
Thermal dissipation
17.4 btu/h
Enclosure type rating
None (open-style)
Ethernet ports
1 Ethernet RJ45 Category 5
CIP unconnected messages
128 + 128 (backplane + Ethernet)
Current draw
1A @ 5.1V DC, 3mA @ 24V DC
Ethernet cable
802.3 compliant shielded or unshielded twisted pair
Wiring category
2 - on Ethernet ports, 3 - on USB ports
Communication rate
10/100 Mbps
Connections supported, max
TCP: 128, CIP: 256 (CIP connections can be used for all explicit or all implicit applications. for exAle, a 1756-ENBT module has a total of 128 CIP connections that can be used for any combination of connections.)
Isolation voltage
30V (continuous), Basic Insulation Type, Ethernet to Backplane, USB to Backplane, and USB to Ethernet(Applies only to these modules/series: 1756-EN2T/D, 1756-EN2TR/C,1756-EN3TR/B), Type tested at 980V AC @ 60s
Supporting protocol for LON
False
Supporting protocol for ASI
False
Supporting protocol for PROFIBUS
False
Supporting protocol for CAN
False
Supporting protocol for INTERBUS
False
Supporting protocol for KNX
False
Supporting protocol for Modbus
False
Supporting protocol for Data-Highway
False
Supporting protocol for SUCONET
False
With potential separation
False
Supporting protocol for SERCOS
False
Supporting protocol for INTERBUS-Safety
False
Radio standard Bluetooth
False
Radio standard Wi-Fi 802.11
False
Supporting protocol for AS-Interface Safety at Work
False
Supporting protocol for Foundation Fieldbus
False
Supporting protocol for PROFINET CBA
False
Supporting protocol for PROFINET IO
False
Supporting protocol for PROFIsafe
False
Supporting protocol for SafetyBUS p
False
Radio standard GPRS
False
Radio standard GSM
False
Radio standard UMTS
False
Slot width
1
ATEX temp code
T4
Surrounding air temperature, max
60 °C
Storage temperature
-40 °C <85 °C (-40 °F <185 °F)
Emissions
CISPR 11: Class A
Vibration
2 G @ 10...500 Hz
ESD immunity
6 kV contact discharges, 8 kV air discharges
EFT/B immunity
±3kV @ 5kHz on Ethernet ports
Relative humidity
5...95% noncondensing
Shock
Operating: 30 G, Nonoperating: 30 G
Conducted RF immunity
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunity
±2 kV line-earth (CM) on Ethernet ports
Operating temperature
0 °C <60 °C (32 °F <140 °F)
Radiated RF immunity
10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3V/m with 1 kHz sine-wave 80% AM from 2000...6000 MHz
North American temperature code
T4A
IECEx temperature code
T4
Module location
Chassis based, any slot
图纸
Dimensional Drawing in 3D (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
图纸
Dimensional Drawing in 3D (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
类型 资源 出版
General Selection Guide 1756-SG001
General Installation Instructions 1756-IN050
General Product Cutsheet --
General Product Profile --
Technical Data 1756-td003_-en-e 1756-TD003
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
China CCC ATEX Australian RCM IECEx Scheme Korean KC UL Listed UKCA DOC
  • China CCC
  • Safety
  • American Bureau of Shippin
  • ATEX
  • CE
  • Australian RCM
  • IECEx Scheme
  • CSA Listed
  • CSA Listed Hazardous
  • FM Approved Haz
  • Korean KC
  • Registro Italiano Navale
  • ODVA
  • UL Listed
  • UL Listed Hazardous
  • UK EX CERTIFICATE
  • MOROCCO DOC
  • UKCA DOC

This product was certified with the above certifications as of 2025-09-08. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

每页项目:
1-1 关于 1
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
技术规格
Communication
Ethernet/IP
Interface
1 Copper RJ45 (10/100 Mbps)
Number Of Channels
1
With optical interface
False
Supporting protocol for TCP/IP
True
Supporting protocol for DeviceNet
False
Supporting protocol for other bus systems
False
Redundancy
False
IO link master
False
Supporting protocol for DeviceNet Safety
False
Supporting protocol for EtherNet/IP
True
Power dissipation
5.1 W
Thermal dissipation
17.4 btu/h
Enclosure type rating
None (open-style)
Ethernet ports
1 Ethernet RJ45 Category 5
CIP unconnected messages
128 + 128 (backplane + Ethernet)
Current draw
1A @ 5.1V DC, 3mA @ 24V DC
Ethernet cable
802.3 compliant shielded or unshielded twisted pair
Wiring category
2 - on Ethernet ports, 3 - on USB ports
Communication rate
10/100 Mbps
Connections supported, max
TCP: 128, CIP: 256 (CIP connections can be used for all explicit or all implicit applications. for exAle, a 1756-ENBT module has a total of 128 CIP connections that can be used for any combination of connections.)
Isolation voltage
30V (continuous), Basic Insulation Type, Ethernet to Backplane, USB to Backplane, and USB to Ethernet(Applies only to these modules/series: 1756-EN2T/D, 1756-EN2TR/C,1756-EN3TR/B), Type tested at 980V AC @ 60s
Supporting protocol for LON
False
Supporting protocol for ASI
False
Supporting protocol for PROFIBUS
False
Supporting protocol for CAN
False
Supporting protocol for INTERBUS
False
Supporting protocol for KNX
False
Supporting protocol for Modbus
False
Supporting protocol for Data-Highway
False
Supporting protocol for SUCONET
False
With potential separation
False
Supporting protocol for SERCOS
False
Supporting protocol for INTERBUS-Safety
False
Radio standard Bluetooth
False
Radio standard Wi-Fi 802.11
False
Supporting protocol for AS-Interface Safety at Work
False
Supporting protocol for Foundation Fieldbus
False
Supporting protocol for PROFINET CBA
False
Supporting protocol for PROFINET IO
False
Supporting protocol for PROFIsafe
False
Supporting protocol for SafetyBUS p
False
Radio standard GPRS
False
Radio standard GSM
False
Radio standard UMTS
False
Slot width
1
ATEX temp code
T4
Surrounding air temperature, max
60 °C
Storage temperature
-40 °C <85 °C (-40 °F <185 °F)
Emissions
CISPR 11: Class A
Vibration
2 G @ 10...500 Hz
ESD immunity
6 kV contact discharges, 8 kV air discharges
EFT/B immunity
±3kV @ 5kHz on Ethernet ports
Relative humidity
5...95% noncondensing
Shock
Operating: 30 G, Nonoperating: 30 G
Conducted RF immunity
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunity
±2 kV line-earth (CM) on Ethernet ports
Operating temperature
0 °C <60 °C (32 °F <140 °F)
Radiated RF immunity
10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3V/m with 1 kHz sine-wave 80% AM from 2000...6000 MHz
North American temperature code
T4A
IECEx temperature code
T4
Module location
Chassis based, any slot
图纸
图纸
Dimensional Drawing in 3D (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
图纸
Dimensional Drawing in 3D (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
Selection Guide General
1756-SG001
Installation Instructions General
1756-IN050
Product Cutsheet General
--
Product Profile General
--
1756-td003_-en-e Technical Data
1756-TD003
类型 资源 出版
General Selection Guide 1756-SG001
General Installation Instructions 1756-IN050
General Product Cutsheet --
General Product Profile --
Technical Data 1756-td003_-en-e 1756-TD003
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
认证
China CCC ATEX Australian RCM IECEx Scheme Korean KC UL Listed UKCA DOC
  • China CCC
  • Safety
  • American Bureau of Shippin
  • ATEX
  • CE
  • Australian RCM
  • IECEx Scheme
  • CSA Listed
  • CSA Listed Hazardous
  • FM Approved Haz
  • Korean KC
  • Registro Italiano Navale
  • ODVA
  • UL Listed
  • UL Listed Hazardous
  • UK EX CERTIFICATE
  • MOROCCO DOC
  • UKCA DOC

This product was certified with the above certifications as of 2025-09-08. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

替代产品
每页项目:
1-1 关于 1
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
Loading
寻找最近经销商
更改位置
EmailEmail
PhonePhone
寻找合作伙伴
CLX ENet/IP 100M
CloseClose
1756-en2t
关闭
打印
Chevron LeftChevron Left
Allen-Bradley 1756-en2t product image
Chevron LeftChevron Left
Allen-Bradley 1756-en2t product image
Allen-Bradley 1756-en2t product image
电话:
呼叫
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页
  2. Chevron LeftChevron Left 产品
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose