Loading
Chevron UpChevron Up
Allen-Bradley 1756-EN2F product image
Allen-Bradley 1756-EN2F product image
Chevron DownChevron Down
Allen-Bradley 1756-EN2F product image
Allen Bradley
畅销产品
1756-EN2F

CLX ENet/IP 100M Fiber

PrintPrint
打印
EmailEmail
共享
Product RegistrationProduct Registration
QR code
Allen-Bradley 1756-EN2F product image
Allen-Bradley 1756-EN2F product image
Allen-Bradley 1756-EN2F product image
Allen Bradley
生命周期状态: 活跃
Product at a glance
Build America, Buy America Build America, Buy America
Repair Options Available
Product Registration
生命周期状态: 活跃
Product at a glance
Build America, Buy America Build America, Buy America
Repair Options Available
Product Registration
添加到BoM
  • 注册产品
  • 寻找支持
Technical Specifications
Drawings
Documents
Certifications
Technotes
Communication Ethernet/IP
Interface 1 Fiber MM LC (100 Mbps)
With optical interface True
Supporting protocol for TCP/IP True
Supporting protocol for DeviceNet False
Supporting protocol for other bus systems False
Redundancy False
IO link master False
Supporting protocol for DeviceNet Safety False
Supporting protocol for EtherNet/IP True
Power dissipation 6.2 W
Thermal dissipation 21.28 btu/h
Enclosure type rating None (open-style)
Ethernet ports 1 Ethernet fiber
CIP unconnected messages 128 + 128 (backplane + Ethernet)
Current draw 1.2A @ 5.1V DC, 3mA @ 24V DC
Ethernet cable Multimode fiber, LC connector
Wiring category 3 - on USB ports
Communication rate 10/100 Mbps
Connections supported, max TCP: 128, CIP: 256 (CIP connections can be used for all explicit or all implicit applications. for exAle, a 1756-ENBT module has a total of 128 CIP connections that can be used for any combination of connections.)
Isolation voltage 30V (continuous), basic insulation type, USB to backplane type tested at 980V AC @ 60s
Supporting protocol for LON False
Supporting protocol for ASI False
Supporting protocol for PROFIBUS False
Supporting protocol for CAN False
Supporting protocol for INTERBUS False
Supporting protocol for KNX False
Supporting protocol for Modbus False
Supporting protocol for Data-Highway False
Supporting protocol for SUCONET False
With potential separation False
Supporting protocol for SERCOS False
Supporting protocol for INTERBUS-Safety False
Radio standard Bluetooth False
Radio standard Wi-Fi 802.11 False
Supporting protocol for AS-Interface Safety at Work False
Supporting protocol for Foundation Fieldbus False
Supporting protocol for PROFINET CBA False
Supporting protocol for PROFINET IO False
Supporting protocol for PROFIsafe False
Supporting protocol for SafetyBUS p False
Radio standard GPRS False
Radio standard GSM False
Radio standard UMTS False
Slot width 1
ATEX temp code T4
Transmitter launch power, min At beginning of Life (BOL): -19 dBm into 62.5/125 µm fiber, N/A = 0.275, -22.5 dBm into 50/125 µm fiber, N/A = 0.20, Allow -1 dB at End of Life (EOL)
Surrounding air temperature, max 60 °C
Storage temperature -40 °C <85 °C (-40 °F <185 °F)
Emissions CISPR 11: Class A
Vibration 2 G @ 10...500 Hz
ESD immunity 6 kV contact discharges, 8 kV air discharges
Relative humidity 5...95% noncondensing
Shock Operating: 30 G, Nonoperating: 30 G
Conducted RF immunity 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Operating temperature 0 °C <60 °C (32 °F <140 °F)
Radiated RF immunity 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
North American temperature code T4A
IECEx temperature code T4
Module location Chassis based, any slot
图纸
Dimensional Drawing in 3D (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
图纸
Dimensional Drawing in 3D (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
类型 资源 出版
General Selection Guide 1756-SG001
General Product Cutsheet --
General Product Profile --
Technical Data 1756-td003_-en-e 1756-TD003
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库 Chevron RightChevron Right
China CCC ATEX Australian RCM IECEx Scheme Korean KC UL Listed UKCA DOC
  • China CCC
  • ODVA
  • ATEX
  • American Bureau of Shippin
  • CE
  • Australian RCM
  • IECEx Scheme
  • CSA Listed
  • FM Approved Haz
  • CSA Listed Hazardous
  • Korean KC
  • Registro Italiano Navale
  • UL Listed Hazardous
  • UL Listed
  • UK EX CERTIFICATE
  • UKCA DOC

This product was certified with the above certifications as of 2025-09-08. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库 Chevron RightChevron Right
技术规格
Communication Ethernet/IP
Interface 1 Fiber MM LC (100 Mbps)
With optical interface True
Supporting protocol for TCP/IP True
Supporting protocol for DeviceNet False
Supporting protocol for other bus systems False
Redundancy False
IO link master False
Supporting protocol for DeviceNet Safety False
Supporting protocol for EtherNet/IP True
Power dissipation 6.2 W
Thermal dissipation 21.28 btu/h
Enclosure type rating None (open-style)
Ethernet ports 1 Ethernet fiber
CIP unconnected messages 128 + 128 (backplane + Ethernet)
Current draw 1.2A @ 5.1V DC, 3mA @ 24V DC
Ethernet cable Multimode fiber, LC connector
Wiring category 3 - on USB ports
Communication rate 10/100 Mbps
Connections supported, max TCP: 128, CIP: 256 (CIP connections can be used for all explicit or all implicit applications. for exAle, a 1756-ENBT module has a total of 128 CIP connections that can be used for any combination of connections.)
Isolation voltage 30V (continuous), basic insulation type, USB to backplane type tested at 980V AC @ 60s
Supporting protocol for LON False
Supporting protocol for ASI False
Supporting protocol for PROFIBUS False
Supporting protocol for CAN False
Supporting protocol for INTERBUS False
Supporting protocol for KNX False
Supporting protocol for Modbus False
Supporting protocol for Data-Highway False
Supporting protocol for SUCONET False
With potential separation False
Supporting protocol for SERCOS False
Supporting protocol for INTERBUS-Safety False
Radio standard Bluetooth False
Radio standard Wi-Fi 802.11 False
Supporting protocol for AS-Interface Safety at Work False
Supporting protocol for Foundation Fieldbus False
Supporting protocol for PROFINET CBA False
Supporting protocol for PROFINET IO False
Supporting protocol for PROFIsafe False
Supporting protocol for SafetyBUS p False
Radio standard GPRS False
Radio standard GSM False
Radio standard UMTS False
Slot width 1
ATEX temp code T4
Transmitter launch power, min At beginning of Life (BOL): -19 dBm into 62.5/125 µm fiber, N/A = 0.275, -22.5 dBm into 50/125 µm fiber, N/A = 0.20, Allow -1 dB at End of Life (EOL)
Surrounding air temperature, max 60 °C
Storage temperature -40 °C <85 °C (-40 °F <185 °F)
Emissions CISPR 11: Class A
Vibration 2 G @ 10...500 Hz
ESD immunity 6 kV contact discharges, 8 kV air discharges
Relative humidity 5...95% noncondensing
Shock Operating: 30 G, Nonoperating: 30 G
Conducted RF immunity 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Operating temperature 0 °C <60 °C (32 °F <140 °F)
Radiated RF immunity 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
North American temperature code T4A
IECEx temperature code T4
Module location Chassis based, any slot
图纸
图纸
Dimensional Drawing in 3D (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
图纸
Dimensional Drawing in 3D (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
Selection Guide General
1756-SG001
Product Cutsheet General
--
Product Profile General
--
1756-td003_-en-e Technical Data
1756-TD003
类型 资源 出版
General Selection Guide 1756-SG001
General Product Cutsheet --
General Product Profile --
Technical Data 1756-td003_-en-e 1756-TD003
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库 Chevron RightChevron Right
认证
China CCC ATEX Australian RCM IECEx Scheme Korean KC UL Listed UKCA DOC
  • China CCC
  • ODVA
  • ATEX
  • American Bureau of Shippin
  • CE
  • Australian RCM
  • IECEx Scheme
  • CSA Listed
  • FM Approved Haz
  • CSA Listed Hazardous
  • Korean KC
  • Registro Italiano Navale
  • UL Listed Hazardous
  • UL Listed
  • UK EX CERTIFICATE
  • UKCA DOC

This product was certified with the above certifications as of 2025-09-08. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库 Chevron RightChevron Right
Loading
寻找最近经销商
更改位置
EmailEmail
PhonePhone
寻找合作伙伴 Chevron RightChevron Right
CLX ENet/IP 100M Fiber
CloseClose
1756-EN2F
关闭
打印
Chevron LeftChevron Left
Allen-Bradley 1756-EN2F product image
Chevron RightChevron Right
Chevron LeftChevron Left
Allen-Bradley 1756-EN2F product image
Allen-Bradley 1756-EN2F product image
Chevron RightChevron Right
电话:
呼叫
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页 Chevron RightChevron Right
  2. Chevron LeftChevron Left 产品 Chevron RightChevron Right
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose