Catalog #: 1756-DNB
Lifecycle status: Active
Allen-Bradley 1756-DNB product image
Allen Bradley
PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Lifecycle status: Active
Add to BoM
  • Register Product
  • Add to Repair Quote
  • Get Support
Technical Specifications
Drawings
Documents
Downloads
Certifications
Alternative Products
Technotes
Number Of Channels 1
Suitable for safety functions True
With optical interface False
Supporting protocol for TCP/IP False
Supporting protocol for DeviceNet True
Supporting protocol for other bus systems False
Redundancy False
IO link master False
Supporting protocol for DeviceNet Safety True
Supporting protocol for EtherNet/IP False
Power dissipation 3.5 W
Thermal dissipation 11.9 btu/h
Enclosure type rating None (open-style)
Number of nodes, max 64 nodes
DeviceNet current draw 60mA @ 24V DC
Current draw 400mA @ 5.1V DC, 0mA @ 24V DC
Wiring category 1 - On DeviceNet ports, 3 - On USB ports
Communication rate 125 Kbps (500 m max), 250 Kbps (250 m max), 500 Kbps (100 m max)
Isolation voltage 50V (continuous), basic insulation type, DeviceNet network to backplane, Type tested at 853V AC @ 60s, No isolation between USB and backplane,
Supporting protocol for LON False
Supporting protocol for ASI False
Supporting protocol for PROFIBUS False
Supporting protocol for CAN False
Supporting protocol for INTERBUS False
Supporting protocol for KNX False
Supporting protocol for Modbus False
Supporting protocol for Data-Highway False
Supporting protocol for SUCONET False
With potential separation False
Supporting protocol for SERCOS False
Supporting protocol for INTERBUS-Safety False
Radio standard Bluetooth False
Radio standard Wi-Fi 802.11 False
Supporting protocol for AS-Interface Safety at Work False
Supporting protocol for Foundation Fieldbus False
Supporting protocol for PROFINET CBA False
Supporting protocol for PROFINET IO False
Supporting protocol for PROFIsafe False
Supporting protocol for SafetyBUS p False
Radio standard GPRS False
Radio standard GSM False
Radio standard UMTS False
Slot width 1
DeviceNet connector torque 0.56 nm
DeviceNet voltage range 11...25V DC CL 2/SELV
DeviceNet port 1 DeviceNet open-style 5- or 10-pin linear plug
DeviceNet power To comply with the CE low voltage directive (LVD), the DeviceNet network must be powered from a source compliant with the safety extra low voltage (SELV) or protected extra low voltage (PELV). To comply with UL restrictions, the DeviceNet network must be
Surrounding air temperature, max 60 °C
Emissions CISPR 11: Class A
Vibration 2 G @ 10...500 Hz
ESD immunity 6 kV contact discharges, 8 kV air discharges
EFT/B immunity ±3kV @ 5kHz on DeviceNet ports
Relative humidity 5...95% noncondensing
Shock Operating: 30 G, Non operating: 50 G
Conducted RF immunity 10Vrms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunity ±2 kV line-earth (CM) on ControlNet ports
Operating temperature 0 to 60 °C
Radiated RF immunity 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Storage temperature -40 °C
North American temperature code T4A
IEC temperature code T4
Module location Chassis based, any slot
Sales Info
Repairable REPAIRABLE
Preferred Availability true
Quick Turnaround false
Dimension Height 18.212
Lead Time 5
Dimension Width 5.588
Dimension Length 22.2
Stock Status STOCKED
Weight 0.365
Weight Unit KG
Dimension Unit CM
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
类型 资源 发布
General Selection Guide 1756-SG001
General Product Cutsheet --
General Product Profile --
Installation Instructions 1756-in566_-en-p 1756-IN566
Technical Data 1756-td003_-en-e 1756-TD003
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library Chevron RightChevron Right
Available Downloads
  • Firmware for 1756-DNB V 12.006,E
  • EDS files for 1756-DNB
  • EDS files for 1756-DNB (multi)
  • EDS files for ControlLogix Family (multi)
See All Downloads Chevron RightChevron Right
UL Listed China CCC ATEX Australian RCM IECEx Scheme
  • UL Listed
  • China CCC
  • Safety
  • ATEX
  • Australian RCM
  • IECEx Scheme
  • CE

This product was certified with the above certifications as of 2025-06-03. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

每页条目数:
1-1 的 1
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Technical Specifications
Number Of Channels 1
Suitable for safety functions True
With optical interface False
Supporting protocol for TCP/IP False
Supporting protocol for DeviceNet True
Supporting protocol for other bus systems False
Redundancy False
IO link master False
Supporting protocol for DeviceNet Safety True
Supporting protocol for EtherNet/IP False
Power dissipation 3.5 W
Thermal dissipation 11.9 btu/h
Enclosure type rating None (open-style)
Number of nodes, max 64 nodes
DeviceNet current draw 60mA @ 24V DC
Current draw 400mA @ 5.1V DC, 0mA @ 24V DC
Wiring category 1 - On DeviceNet ports, 3 - On USB ports
Communication rate 125 Kbps (500 m max), 250 Kbps (250 m max), 500 Kbps (100 m max)
Isolation voltage 50V (continuous), basic insulation type, DeviceNet network to backplane, Type tested at 853V AC @ 60s, No isolation between USB and backplane,
Supporting protocol for LON False
Supporting protocol for ASI False
Supporting protocol for PROFIBUS False
Supporting protocol for CAN False
Supporting protocol for INTERBUS False
Supporting protocol for KNX False
Supporting protocol for Modbus False
Supporting protocol for Data-Highway False
Supporting protocol for SUCONET False
With potential separation False
Supporting protocol for SERCOS False
Supporting protocol for INTERBUS-Safety False
Radio standard Bluetooth False
Radio standard Wi-Fi 802.11 False
Supporting protocol for AS-Interface Safety at Work False
Supporting protocol for Foundation Fieldbus False
Supporting protocol for PROFINET CBA False
Supporting protocol for PROFINET IO False
Supporting protocol for PROFIsafe False
Supporting protocol for SafetyBUS p False
Radio standard GPRS False
Radio standard GSM False
Radio standard UMTS False
Slot width 1
DeviceNet connector torque 0.56 nm
DeviceNet voltage range 11...25V DC CL 2/SELV
DeviceNet port 1 DeviceNet open-style 5- or 10-pin linear plug
DeviceNet power To comply with the CE low voltage directive (LVD), the DeviceNet network must be powered from a source compliant with the safety extra low voltage (SELV) or protected extra low voltage (PELV). To comply with UL restrictions, the DeviceNet network must be
Surrounding air temperature, max 60 °C
Emissions CISPR 11: Class A
Vibration 2 G @ 10...500 Hz
ESD immunity 6 kV contact discharges, 8 kV air discharges
EFT/B immunity ±3kV @ 5kHz on DeviceNet ports
Relative humidity 5...95% noncondensing
Shock Operating: 30 G, Non operating: 50 G
Conducted RF immunity 10Vrms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunity ±2 kV line-earth (CM) on ControlNet ports
Operating temperature 0 to 60 °C
Radiated RF immunity 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Storage temperature -40 °C
North American temperature code T4A
IEC temperature code T4
Module location Chassis based, any slot
Sales Info
Repairable REPAIRABLE
Preferred Availability true
Quick Turnaround false
Dimension Height 18.212
Lead Time 5
Dimension Width 5.588
Dimension Length 22.2
Stock Status STOCKED
Weight 0.365
Weight Unit KG
Dimension Unit CM
Drawings
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
文档
Selection Guide General
1756-SG001
Product Cutsheet General
--
Product Profile General
--
1756-in566_-en-p Installation Instructions
1756-IN566
1756-td003_-en-e Technical Data
1756-TD003
类型 资源 发布
General Selection Guide 1756-SG001
General Product Cutsheet --
General Product Profile --
Installation Instructions 1756-in566_-en-p 1756-IN566
Technical Data 1756-td003_-en-e 1756-TD003
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library Chevron RightChevron Right
下载
Available Downloads
  • Firmware for 1756-DNB V 12.006,E
  • EDS files for 1756-DNB
  • EDS files for 1756-DNB (multi)
  • EDS files for ControlLogix Family (multi)
See All Downloads Chevron RightChevron Right
认证
UL Listed China CCC ATEX Australian RCM IECEx Scheme
  • UL Listed
  • China CCC
  • Safety
  • ATEX
  • Australian RCM
  • IECEx Scheme
  • CE

This product was certified with the above certifications as of 2025-06-03. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Alternative Products
每页条目数:
1-1 的 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Loading
Find your nearest distributor
Change location
EmailEmail
PhonePhone
Find a partner Chevron RightChevron Right
ControlLogix DeviceNet Comms Module
CloseClose
1756-DNB
关闭
打印
Allen-Bradley 1756-DNB product image
手机:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页 Chevron RightChevron Right
  2. Chevron LeftChevron Left 产品 Chevron RightChevron Right
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose