生命周期状态:
停止
Rockwell Automation announces that as of December 31, 2024, the ControlLogix Communication Module will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停售日期:
December 31, 2024
替代类别:
Engineering Replacement
替代产品:
1756-CN2
[https://www.rockwellautomation.com.cn/products/details.1756-CN2.html]
产品概览
可享更换服务
Description
ControlNet 网桥模块(40~48个连接)
1756-CNB
ControlLogix Communication Module
Serial #:
此产品尚未验证,请{}确认真实性
注册您的产品
生命周期状态:
停止
Rockwell Automation announces that as of December 31, 2024, the ControlLogix Communication Module will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停售日期:
December 31, 2024
替代类别:
Engineering Replacement
替代产品:
1756-CN2
[https://www.rockwellautomation.com.cn/products/details.1756-CN2.html]
产品概览
可享更换服务
Description
ControlNet 网桥模块(40~48个连接)
产品详细信息
请查看产品标签上的“SER”标识,以确定您的产品系列。如需查找针对您产品的具体信息,请扫描产品标签上的二维码。
E
概述
Electrical & Connectivity
General Features
Power & Electrical Characteristics
Compliance & Environment
Standards & Protection
Physical Characteristics
Mechanical
图纸
文档
下载
认证
替代产品
技术说明
| 唯一产品序列号 |
1756-CNB
|
|---|---|
| 通用产品代码(UPC) |
612598174072
|
| 标准保修期 |
1年 查看详情 |
| 原产国 |
美利坚合众国
|
| Communication |
ControlNet
|
|---|---|
| Interface |
1 ControlNet BNC
|
| Number Of Channels |
1
|
| Connections supported, max |
64 maximum
|
|---|---|
| ControlNet cable |
1786-RG6 quad shield RG6 coaxial cable
|
| ControlNet port |
1 ControlNet BNC
|
| Current draw |
970mA @ 5.1V DC, 1.7mA @ 24V DC
|
| Enclosure type rating |
None (open-style)
|
| IO link master |
False
|
| Isolation voltage |
Standard: 30V (continuous), basic insulation type, ControlNet network to, backplane, Redundant: 30V (continuous), basic insulation type, ControlNet A/B to, backplane, and ControlNet A to ControlNet B, USB to backplane and USB to ControlNet, No isolation b
|
| Logix communication connections range |
40...48
|
| NAP cable |
1786-CP
|
| NAP port |
1 NAP RJ45
|
| Number of nodes, max |
99 nodes
|
| Power dissipation |
5.1 W
|
| Radio standard Bluetooth |
False
|
| Radio standard GPRS |
False
|
| Radio standard GSM |
False
|
| Radio standard UMTS |
False
|
| Radio standard Wi-Fi 802.11 |
False
|
| Redundancy |
False
|
| Slot width |
1
|
| Supporting protocol for AS-Interface Safety at Work |
False
|
| Supporting protocol for ASI |
False
|
| Supporting protocol for CAN |
False
|
| Supporting protocol for Data-Highway |
False
|
| Supporting protocol for DeviceNet |
False
|
| Supporting protocol for DeviceNet Safety |
False
|
| Supporting protocol for EtherNet/IP |
False
|
| Supporting protocol for Foundation Fieldbus |
False
|
| Supporting protocol for INTERBUS |
False
|
| Supporting protocol for INTERBUS-Safety |
False
|
| Supporting protocol for KNX |
False
|
| Supporting protocol for LON |
False
|
| Supporting protocol for Modbus |
False
|
| Supporting protocol for PROFIBUS |
False
|
| Supporting protocol for PROFINET CBA |
False
|
| Supporting protocol for PROFINET IO |
False
|
| Supporting protocol for PROFIsafe |
False
|
| Supporting protocol for SERCOS |
False
|
| Supporting protocol for SUCONET |
False
|
| Supporting protocol for SafetyBUS p |
False
|
| Supporting protocol for TCP/IP |
False
|
| Supporting protocol for other bus systems |
True
|
| Thermal dissipation |
17.4 btu/h
|
| Transmission rate |
5000 kbps
|
| Wiring category |
1 - on ControlNet ports, 3 - on NAP ports
|
| With optical interface |
False
|
| With potential separation |
False
|
| Conducted RF immunity |
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
|
|---|---|
| EFT/B immunity |
±3kV @ 5kHz on ControlNet ports
|
| ESD immunity |
6 kV contact discharges, 8 kV air discharges
|
| Emissions |
CISPR 11: Class A
|
| Operating temperature |
0 to 60 °C
|
| Radiated RF immunity |
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
|
| Relative humidity |
5...95% noncondensing
|
| Shock |
Operating: 30 G, Non operating: 50 G
|
| Storage temperature |
-40 to 85 °C
|
| Surge transient immunity |
±2 kV line-earth (CM) on ControlNet ports
|
| Surrounding air temperature, max |
60 °C
|
| Vibration |
2 G @ 10...500 Hz
|
Mechanical
| Module location |
Chassis based, any slot
|
|---|---|
| Weight, approx |
0.26 kg
|
点击下方 Download CAD 按钮,查看所有可下载的文件格式。
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
| 基本信息 | 出版 |
|---|---|
| Selection Guide | 1756-SG001 |
| Product Profile | -- |
| Installation Instructions | 1756-IN604 |
| Product Cutsheet | -- |
| 技术数据 | 出版 |
|---|---|
| 1756-td003_-en-e | 1756-TD003 |
版本:
发布说明
| Firmware Tools | 大小 | 备注 | |
|---|---|---|---|
|
|
Comms Bundle 1756-CNB(R) | 126 MB | 发布说明 |
|
|
Comms Bundle 1756-CNB(R) | 126 MB | 发布说明 |
| Firmware | 大小 | 备注 | |
|
|
Firmware for 1756-CNB V 11.004,E | 19.93 MB | 发布说明 |
- UL Listed
- UL Listed Hazardous
- ODVA
- Australian RCM
- ATEX
- China CCC
- CE
- CSA Listed
- CSA Listed Hazardous
- Eurasion Economic Community
- Korean KC
- Bureau Veritas
- FM Approved Haz
- Registro Italiano Navale
- Safety
- IECEx Scheme
- MOROCCO DOC
截至 2026-10-09,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。
正在查找认证文件?
请浏览我们内容详尽的资料库,查看该产品及其他产品的认证信息。
法规信息
| 欧盟进口商地址 |
Rockwell Automation N.V |
|---|---|
| 欧盟授权代表地址 |
Rockwell Automation N.V |
每页项目:
| 技术说明 |
|---|
概述
| 唯一产品序列号 |
1756-CNB
|
|---|---|
| 通用产品代码(UPC) |
612598174072
|
| 标准保修期 |
1年 查看详情 |
| 原产国 |
美利坚合众国
|
Electrical & Connectivity
| Communication |
ControlNet
|
|---|---|
| Interface |
1 ControlNet BNC
|
| Number Of Channels |
1
|
| Connections supported, max |
64 maximum
|
|---|---|
| ControlNet cable |
1786-RG6 quad shield RG6 coaxial cable
|
| ControlNet port |
1 ControlNet BNC
|
| Current draw |
970mA @ 5.1V DC, 1.7mA @ 24V DC
|
| Enclosure type rating |
None (open-style)
|
| IO link master |
False
|
| Isolation voltage |
Standard: 30V (continuous), basic insulation type, ControlNet network to, backplane, Redundant: 30V (continuous), basic insulation type, ControlNet A/B to, backplane, and ControlNet A to ControlNet B, USB to backplane and USB to ControlNet, No isolation b
|
| Logix communication connections range |
40...48
|
| NAP cable |
1786-CP
|
| NAP port |
1 NAP RJ45
|
| Number of nodes, max |
99 nodes
|
| Power dissipation |
5.1 W
|
| Radio standard Bluetooth |
False
|
| Radio standard GPRS |
False
|
| Radio standard GSM |
False
|
| Radio standard UMTS |
False
|
| Radio standard Wi-Fi 802.11 |
False
|
| Redundancy |
False
|
| Slot width |
1
|
| Supporting protocol for AS-Interface Safety at Work |
False
|
| Supporting protocol for ASI |
False
|
| Supporting protocol for CAN |
False
|
| Supporting protocol for Data-Highway |
False
|
| Supporting protocol for DeviceNet |
False
|
| Supporting protocol for DeviceNet Safety |
False
|
| Supporting protocol for EtherNet/IP |
False
|
| Supporting protocol for Foundation Fieldbus |
False
|
| Supporting protocol for INTERBUS |
False
|
| Supporting protocol for INTERBUS-Safety |
False
|
| Supporting protocol for KNX |
False
|
| Supporting protocol for LON |
False
|
| Supporting protocol for Modbus |
False
|
| Supporting protocol for PROFIBUS |
False
|
| Supporting protocol for PROFINET CBA |
False
|
| Supporting protocol for PROFINET IO |
False
|
| Supporting protocol for PROFIsafe |
False
|
| Supporting protocol for SERCOS |
False
|
| Supporting protocol for SUCONET |
False
|
| Supporting protocol for SafetyBUS p |
False
|
| Supporting protocol for TCP/IP |
False
|
| Supporting protocol for other bus systems |
True
|
| Thermal dissipation |
17.4 btu/h
|
| Transmission rate |
5000 kbps
|
| Wiring category |
1 - on ControlNet ports, 3 - on NAP ports
|
| With optical interface |
False
|
| With potential separation |
False
|
Compliance & Environment
| Conducted RF immunity |
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
|
|---|---|
| EFT/B immunity |
±3kV @ 5kHz on ControlNet ports
|
| ESD immunity |
6 kV contact discharges, 8 kV air discharges
|
| Emissions |
CISPR 11: Class A
|
| Operating temperature |
0 to 60 °C
|
| Radiated RF immunity |
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
|
| Relative humidity |
5...95% noncondensing
|
| Shock |
Operating: 30 G, Non operating: 50 G
|
| Storage temperature |
-40 to 85 °C
|
| Surge transient immunity |
±2 kV line-earth (CM) on ControlNet ports
|
| Surrounding air temperature, max |
60 °C
|
| Vibration |
2 G @ 10...500 Hz
|
Physical Characteristics
Mechanical
| Module location |
Chassis based, any slot
|
|---|---|
| Weight, approx |
0.26 kg
|
图纸
点击下方 Download CAD 按钮,查看所有可下载的文件格式。
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
|
Selection Guide
基本信息
1756-SG001 |
|
Product Profile
基本信息
-- |
|
Installation Instructions
基本信息
1756-IN604 |
|
Product Cutsheet
基本信息
-- |
|
1756-td003_-en-e
技术数据
1756-TD003 |
| 基本信息 | 出版 |
|---|---|
| Selection Guide | 1756-SG001 |
| Product Profile | -- |
| Installation Instructions | 1756-IN604 |
| Product Cutsheet | -- |
| 技术数据 | 出版 |
| 1756-td003_-en-e | 1756-TD003 |
下载
版本:
发布说明
| Firmware Tools | 大小 | 备注 | |
|---|---|---|---|
|
|
Comms Bundle 1756-CNB(R) | 126 MB | 发布说明 |
|
|
Comms Bundle 1756-CNB(R) | 126 MB | 发布说明 |
| Firmware | 大小 | 备注 | |
|
|
Firmware for 1756-CNB V 11.004,E | 19.93 MB | 发布说明 |
认证
- UL Listed
- UL Listed Hazardous
- ODVA
- Australian RCM
- ATEX
- China CCC
- CE
- CSA Listed
- CSA Listed Hazardous
- Eurasion Economic Community
- Korean KC
- Bureau Veritas
- FM Approved Haz
- Registro Italiano Navale
- Safety
- IECEx Scheme
- MOROCCO DOC
截至 2026-10-09,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。
正在查找认证文件?
请浏览我们内容详尽的资料库,查看该产品及其他产品的认证信息。
法规信息
| 欧盟进口商地址 |
Rockwell Automation N.V |
|---|---|
| 欧盟授权代表地址 |
Rockwell Automation N.V |
替代产品
每页项目:
技术说明
| 技术说明 |
|---|
基于制造地点的多个原产国
ControlLogix Communication Module
1756-CNB
关闭
打印
Copyright ©2026 Rockwell Automation, Inc.