Loading
Chevron UpChevron Up
Allen-Bradley 150-f85nbd product image
Allen-Bradley 150-f85nbd product image
Chevron DownChevron Down
Allen-Bradley 150-f85nbd product image
Allen Bradley
畅销书

SMC Flex Smart Motor Controller

PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Catalog #: 150-f85nbd
Lifecycle status: Active
Allen-Bradley 150-f85nbd product image
Allen-Bradley 150-f85nbd product image
Allen-Bradley 150-f85nbd product image
Allen Bradley
PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Lifecycle status: Active
Add to BoM
  • Add to Repair Quote
  • Get Support
Repair Options
CloseClose
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
Schedule a repair Request repair documentation Repair terms and conditions
Technical Specifications
Drawings
Documents
Certifications
Accessories
Technotes
Controller Rating 85 A 15-60Hp @ 460V AC
Control Voltage 100...240V AC
Product Family SMC Flex
With display True
Voltage type for actuating AC
Rated operating voltage Ue 200 V
Rated control supply voltage at AC 50 Hz 100 V
Rated control supply voltage at AC 60 Hz 100 V
Overload current for line connected devices 17 A
Overload current for delta connected devices 29.4 A
Controller type Soft starter
Control options None
Trip classes 10, 15, 20 and 30
Trip current rating 117% of motor FLC
Transformer control module 75VA @ 100...240V AC (-15%, +10%)
Heatsink fan rating 20VA @ 110/120V AC or 220/240V AC
DV/DT protection RC snubber network for power circuit
Repetitive peak inverse voltage rating 1400V per UL/CSA/NEMA for power circuit
Operating frequency 50/60 Hz for power circuit
Line connected motor power, max 75Hp @ 575V AC, 60 Hz, 3-phase
Delta connected motor power, max 90 kW @ 500V AC @ 50Hz, 3-phase
Rated impulse voltage 6000V per IEC for power circuit
Dielectric withstand 2500V per IEC for power circuit
Line connected motor current 17...85A @ 500/575V AC, 3-phase
Delta connected motor current 29.4...147A @ 500/575V AC, 3-phase
Transient protection Metal oxide varistors: 220 J (optional) for power circuit
Insulation voltage Rated 500V per IEC for power circuit
Rated operational voltage 200...480V AC (-15%, +10%) per UL/CSA/NEMA for power circuit
Input OFF-state current <10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage
Short-circuit protection device list Standard fuse, circuit breaker and high capacity time delay class CC/J/L
Number of contacts 1 for auxiliary contacts
High capacity available fault current, max 70kA @ 600V, maximum current 200 A time delay Class J or Class L fuse for inside delta connected motors
Type of current AC for auxiliary contacts
Conventional thermal current (Ith) AC/DC: 5 A for auxiliary contacts
Type of control circuit Electromagnetic relay for auxiliary contacts
Type of contacts Progmable NO/NC for auxiliary contacts
Utilization category MG 1 per UL/CSA/NEMA for power circuit
Standard controller feature Status indication: stopped, starting, stopping, at speed, alarm and fault
Standard available fault current, max 10kA @ 200...600V, maximum standard fuse 400 A for delta device opsal current rating
Optional controller feature SMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0...400% of the motor’s full-load current rating
Integrated motor overload protection True
Short circuit protection device performance (SCPD) type Type 1
Number of sensors, max 6 for PTC input ratings
Inrush current control module 5A @ 24V DC (-15%, +10%)
Voltage at PTC terminals (RPTC = open), max 30V for PTC input ratings
Transient watts control module 60 W @ 24V DC (-15%, +10%)
Steady state watts control module 24 W @ 24V DC (-15%, +10%)
Voltage at PTC terminals (RPTC = 4 kΩ), max <7.5 for PTC input ratings
Response time 800 ms for PTC input ratings
Inrush time control module 250 ms @ 24V DC (-15%, +10%)
Transient time control module 500 ms @ 24V DC (-15%, +10%)
Cold resistance of PTC sensor chain, max 1500 Ω for PTC input ratings
Tachometer input 0...5V DC @ 4.5V DC = 100% Speed
Allen bradley power supply control module, min 1606-XLP50E @ 24V DC (-15%, +10%)
Short circuit trip resistance 25 Ω ± 10 Ω for PTC input ratings
Response resistance 3400 Ω ± 150 Ω for PTC input ratings
Reset resistance 1600 Ω ± 100 Ω for PTC input ratings
Input OFF-state voltage, max 50V AC @ 10V DC/12V AC for control circuit
Input ON-state voltage, min 85V AC @ 19.2V DC/20.4V AC for control circuit
Lower line side cable size 0.8...2.5 mm2 (18...14 AWG) for power terminals
Lower load side cable size 0.8...2.5 mm2 (18...14 AWG) for power terminals
Upper load side cable size 2.5...50 mm2 (14...1 AWG) for load power terminals
Upper line side cable size 2.5...95 mm2 (14...3 AWG) for line power terminals
Rated operational current 3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts
Input ON-state current 20mA @ 120V AC/40mA @ 240V AC, 7.6mA @ 24V AC/DC for control circuit
Contact type Auxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4)
Steady state heat dissipation with control and fan power 129 W
Storage and transportation temperature -20 °C
Humidity 5...95% (noncondensing)
Operating temperature Open: -5 to 50 °C (23 to 122 °F)
Protection against electrical shock IP20 per IEC for power circuit
EMC emission levels Radiated emission: Class A
EMC immunity levels Surge transient: per EN/IEC 60947-4-2
Altitude 2000 m
Pollution degree 2
Weight 5.7 kg
Shock Opsal: 15 G
Width 150 mm (5.90 in)
Depth 203 mm (8 in)
Height 321 mm (12.60 in)
Power pole construction Heatsink thyristor modular design
Vibration Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Make 3600VA for auxiliary contacts
Break 360VA for auxiliary contacts
Tightening torque 14.7 Nm (130 in-lb) for power terminals
Internal bypass True
Function Single direction
Power terminal markings NEMA, CENELEC EN50 012
Control terminals ClAing yoke connection, M3 screw clA
Wire strip length 18...20 mm (0.22...0.34 in) for power terminals
Number of poles 3
Enclosure Open type
Control modules construction Thermoset and thermoplastic moldings
Metal parts construction Plated brass, copper or painted steel
Sales Info
Repairable REPAIRABLE
Preferred Availability true
Quick Turnaround false
Dimension Height 29.489
Lead Time 21
Dimension Width 18.009
Dimension Length 40.488
Stock Status STOCKED
Weight 6.469
Weight Unit KG
Dimension Unit CM
Drawings
Product Drawing Drawing (DWG)
Drawings
Product Drawing Drawing (DWG)
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
类型 资源 发布
General Short Circuit Ratings Data Sheet --
General Dimension Sheet --
General Specifications Sheet and Wiring Diagram --
General Repair Parts List --
General 3D Dimensions (STEP) --
General Modes of Operation --
General Features --
General Product Cutsheet --
Technical Data 150-td009_-en-p 150-TD009
User Manual 150-um008_-en-p 150-UM008
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Chevron RightChevron Right Search the Literature Library Chevron RightChevron Right
China CCC Eurasion Economic Community Australian RCM
  • China CCC
  • Eurasion Economic Community
  • Australian RCM

This product was certified with the above certifications as of 2025-07-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

每页条目数:
1-1 的 1
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Technical Specifications
Controller Rating 85 A 15-60Hp @ 460V AC
Control Voltage 100...240V AC
Product Family SMC Flex
With display True
Voltage type for actuating AC
Rated operating voltage Ue 200 V
Rated control supply voltage at AC 50 Hz 100 V
Rated control supply voltage at AC 60 Hz 100 V
Overload current for line connected devices 17 A
Overload current for delta connected devices 29.4 A
Controller type Soft starter
Control options None
Trip classes 10, 15, 20 and 30
Trip current rating 117% of motor FLC
Transformer control module 75VA @ 100...240V AC (-15%, +10%)
Heatsink fan rating 20VA @ 110/120V AC or 220/240V AC
DV/DT protection RC snubber network for power circuit
Repetitive peak inverse voltage rating 1400V per UL/CSA/NEMA for power circuit
Operating frequency 50/60 Hz for power circuit
Line connected motor power, max 75Hp @ 575V AC, 60 Hz, 3-phase
Delta connected motor power, max 90 kW @ 500V AC @ 50Hz, 3-phase
Rated impulse voltage 6000V per IEC for power circuit
Dielectric withstand 2500V per IEC for power circuit
Line connected motor current 17...85A @ 500/575V AC, 3-phase
Delta connected motor current 29.4...147A @ 500/575V AC, 3-phase
Transient protection Metal oxide varistors: 220 J (optional) for power circuit
Insulation voltage Rated 500V per IEC for power circuit
Rated operational voltage 200...480V AC (-15%, +10%) per UL/CSA/NEMA for power circuit
Input OFF-state current <10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage
Short-circuit protection device list Standard fuse, circuit breaker and high capacity time delay class CC/J/L
Number of contacts 1 for auxiliary contacts
High capacity available fault current, max 70kA @ 600V, maximum current 200 A time delay Class J or Class L fuse for inside delta connected motors
Type of current AC for auxiliary contacts
Conventional thermal current (Ith) AC/DC: 5 A for auxiliary contacts
Type of control circuit Electromagnetic relay for auxiliary contacts
Type of contacts Progmable NO/NC for auxiliary contacts
Utilization category MG 1 per UL/CSA/NEMA for power circuit
Standard controller feature Status indication: stopped, starting, stopping, at speed, alarm and fault
Standard available fault current, max 10kA @ 200...600V, maximum standard fuse 400 A for delta device opsal current rating
Optional controller feature SMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0...400% of the motor’s full-load current rating
Integrated motor overload protection True
Short circuit protection device performance (SCPD) type Type 1
Number of sensors, max 6 for PTC input ratings
Inrush current control module 5A @ 24V DC (-15%, +10%)
Voltage at PTC terminals (RPTC = open), max 30V for PTC input ratings
Transient watts control module 60 W @ 24V DC (-15%, +10%)
Steady state watts control module 24 W @ 24V DC (-15%, +10%)
Voltage at PTC terminals (RPTC = 4 kΩ), max <7.5 for PTC input ratings
Response time 800 ms for PTC input ratings
Inrush time control module 250 ms @ 24V DC (-15%, +10%)
Transient time control module 500 ms @ 24V DC (-15%, +10%)
Cold resistance of PTC sensor chain, max 1500 Ω for PTC input ratings
Tachometer input 0...5V DC @ 4.5V DC = 100% Speed
Allen bradley power supply control module, min 1606-XLP50E @ 24V DC (-15%, +10%)
Short circuit trip resistance 25 Ω ± 10 Ω for PTC input ratings
Response resistance 3400 Ω ± 150 Ω for PTC input ratings
Reset resistance 1600 Ω ± 100 Ω for PTC input ratings
Input OFF-state voltage, max 50V AC @ 10V DC/12V AC for control circuit
Input ON-state voltage, min 85V AC @ 19.2V DC/20.4V AC for control circuit
Lower line side cable size 0.8...2.5 mm2 (18...14 AWG) for power terminals
Lower load side cable size 0.8...2.5 mm2 (18...14 AWG) for power terminals
Upper load side cable size 2.5...50 mm2 (14...1 AWG) for load power terminals
Upper line side cable size 2.5...95 mm2 (14...3 AWG) for line power terminals
Rated operational current 3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts
Input ON-state current 20mA @ 120V AC/40mA @ 240V AC, 7.6mA @ 24V AC/DC for control circuit
Contact type Auxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4)
Steady state heat dissipation with control and fan power 129 W
Storage and transportation temperature -20 °C
Humidity 5...95% (noncondensing)
Operating temperature Open: -5 to 50 °C (23 to 122 °F)
Protection against electrical shock IP20 per IEC for power circuit
EMC emission levels Radiated emission: Class A
EMC immunity levels Surge transient: per EN/IEC 60947-4-2
Altitude 2000 m
Pollution degree 2
Weight 5.7 kg
Shock Opsal: 15 G
Width 150 mm (5.90 in)
Depth 203 mm (8 in)
Height 321 mm (12.60 in)
Power pole construction Heatsink thyristor modular design
Vibration Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Make 3600VA for auxiliary contacts
Break 360VA for auxiliary contacts
Tightening torque 14.7 Nm (130 in-lb) for power terminals
Internal bypass True
Function Single direction
Power terminal markings NEMA, CENELEC EN50 012
Control terminals ClAing yoke connection, M3 screw clA
Wire strip length 18...20 mm (0.22...0.34 in) for power terminals
Number of poles 3
Enclosure Open type
Control modules construction Thermoset and thermoplastic moldings
Metal parts construction Plated brass, copper or painted steel
Sales Info
Repairable REPAIRABLE
Preferred Availability true
Quick Turnaround false
Dimension Height 29.489
Lead Time 21
Dimension Width 18.009
Dimension Length 40.488
Stock Status STOCKED
Weight 6.469
Weight Unit KG
Dimension Unit CM
Drawings
Drawings
Product Drawing Drawing (DWG)
Drawings
Product Drawing Drawing (DWG)
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
文档
Short Circuit Ratings Data Sheet General
--
Dimension Sheet General
--
Specifications Sheet and Wiring Diagram General
--
Repair Parts List General
--
3D Dimensions (STEP) General
--
Modes of Operation General
--
Features General
--
Product Cutsheet General
--
150-td009_-en-p Technical Data
150-TD009
150-um008_-en-p User Manual
150-UM008
类型 资源 发布
General Short Circuit Ratings Data Sheet --
General Dimension Sheet --
General Specifications Sheet and Wiring Diagram --
General Repair Parts List --
General 3D Dimensions (STEP) --
General Modes of Operation --
General Features --
General Product Cutsheet --
Technical Data 150-td009_-en-p 150-TD009
User Manual 150-um008_-en-p 150-UM008
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Chevron RightChevron Right Search the Literature Library Chevron RightChevron Right
认证
China CCC Eurasion Economic Community Australian RCM
  • China CCC
  • Eurasion Economic Community
  • Australian RCM

This product was certified with the above certifications as of 2025-07-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Accessories
每页条目数:
1-1 的 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Loading
Find your nearest distributor
Change location
EmailEmail
PhonePhone
Find a partner Chevron RightChevron Right
SMC Flex Smart Motor Controller
CloseClose
150-f85nbd
关闭
打印
Chevron LeftChevron Left
Allen-Bradley 150-f85nbd product image
Chevron RightChevron Right
Chevron LeftChevron Left
Allen-Bradley 150-f85nbd product image
Allen-Bradley 150-f85nbd product image
Chevron RightChevron Right
手机:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页 Chevron RightChevron Right
  2. Chevron LeftChevron Left 产品 Chevron RightChevron Right
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose