Loading
Chevron UpChevron Up
Allen-Bradley 150-C3NBD product image
Allen-Bradley 150-C3NBD product image
Chevron DownChevron Down
Allen-Bradley 150-C3NBD product image
Allen Bradley
150-C3NBD

SMC-3 3A Smart Motor Controller

PrintPrint
打印
EmailEmail
共享
Product RegistrationProduct Registration
Scan code
Allen-Bradley 150-C3NBD product image
Allen-Bradley 150-C3NBD product image
Allen-Bradley 150-C3NBD product image
Allen Bradley
Lifecycle status: Active
Lifecycle status: Active
Add to BoM
  • Get Support
Repair Options
CloseClose
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
Schedule a repair Request repair documentation Repair terms and conditions
Technical Specifications
Drawings
Documents
Certifications
Accessories
Technotes
Product Family SMC-3
With display False
Voltage type for actuating AC/DC
Rated operating voltage Ue 200 V
Rated control supply voltage at AC 50 Hz 100 V
Rated control supply voltage at AC 60 Hz 100 V
Overload current 1 A
Controller type SMC-3
DV/DT protection 1000V/µs for power circuit
Repetitive peak voltage 1400V per UL/CSA/NEMA for power circuit
Operating frequency 50/60 Hz per UL/CSA/NEMA for power circuit
Line connected motor power, max 1.1 kW @ 380/400/415V AC @ 50Hz, 3-phase
Delta connected motor power, max 1Hp @ 230V AC, 60 Hz, 3-phase
Overvoltage category III per IEC for side mount auxiliary contacts
Rated impulse voltage 6 kV for power circuit
Dielectric withstand 2500V AC per IEC for power circuit
Line connected motor current 1...3A @ 380/400/415/460V AC, 3-phase
Delta connected motor current 1.7...5.1A @ 380/400/415/460V AC, 3-phase
Insulation voltage Rated 600V AC per UL/CSA/NEMA for power circuit
Rated operational voltage 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Rated control power during start with fan 215mA @ 120V AC/180mA @ 240V AC, 800mA @ 24V DC/660mA @ 24V AC
Input OFF-state current <10 mA, <12 mA @ input OFF-state voltage (IN1, IN2) for control circuit
Short-circuit protection device list Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Number of contacts TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
High capacity available fault current, max 69kA @ 600V, maximum current 10 A time delay Class J or Class L fuse for inside delta connected motors
Type of current TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
Conventional thermal current (Ith) TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of control circuit TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Type of contacts TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Utilization category TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Rated operational current, max TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Standard controller feature Soft stop
Standard available fault current, max 5 kA @ maximum standard fuse 15 A for delta device opsal current rating
Integrated motor overload protection True
Short circuit protection device performance (SCPD) type Type 1
Selectable overload trip class Trip Class 10, 15, or 20
Selectable start times 2, 5, 10, 15, 20, 25, or 30 s
Input OFF-state voltage (IN1, IN2), max 40V AC @ 17V DC/12V AC for control circuit
Selectable current limit 150%, 250%, 350%, and 450% of full load current
Input ON-state voltage, during start (IN1, IN2) 85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Rated control power during start without fan 205mA @ 120V AC/145mA @ 240V AC, 705mA @ 24V DC/580mA @ 24V AC
Input ON-state current (IN1, IN2) 9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Degree of protection (IP) IP2X
Weight 0.86 kg
Shock Opsal: 15 G
Width 44.8 mm (1.76 in)
Depth 110 mm (4.33 in)
Height 139.7 mm (5.5 in)
Cable size 2.5...25 mm² (14...4 AWG) for line power terminals
Vibration Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Make TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
Break TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Tightening torque 2.3...3.4 Nm (30 in-lb) for line power terminals, 4.0 Nm (35 in-lb) if 25 mm² (4 AWG) wire in top terminal for line power terminal
Internal bypass True
Function Single direction
Selectable kick start - 450% FLA 0, 0.5, 1.0, or 1.5 s
Selectable initial torque 15%, 25%, 35%, and 65% of locked rotor torque
Selectable soft stop Off, 100%, 200%, or 300% of the start time setting when wired
Steady state heat dissipation 11 W
Storage and transportation temperature -25 °C
Rated surrounding temperature range without derating -5 °C
Humidity 5...95% noncondensing
Operating temperature Open: -5 to 50 °C (23 to 122 °F)
EMC emission levels Radiated emission: Class A per IEC
EMC immunity levels Surge transient: per EN/IEC 60947-4-2 per IEC
Altitude 2000 m
Pollution degree 2
Mounting hole size 4.6 mm
Number of poles Equipment is designed for 3-phase only for power circuit
Enclosure Open type
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
类型 资源 发布
General OL Trip Curves and Starts per Hour Curves --
General Short Circuit Ratings Data Sheet --
General Wiring --
General Dimension Sheet (PDF) --
General Dimension Sheet (Catalog) --
General Product Cutsheet --
General Features and Modes of Operation --
General Specifications Sheet --
Installation Instructions 150-in044_-en-e 150-IN044
Technical Data 150-td009_-en-p 150-TD009
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Chevron RightChevron Right Search the Literature Library Chevron RightChevron Right
China CCC Eurasion Economic Community Australian RCM
  • China CCC
  • Eurasion Economic Community
  • Australian RCM

This product was certified with the above certifications as of 2025-07-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

每页条目数:
1-1 的 1
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Technical Specifications
Product Family SMC-3
With display False
Voltage type for actuating AC/DC
Rated operating voltage Ue 200 V
Rated control supply voltage at AC 50 Hz 100 V
Rated control supply voltage at AC 60 Hz 100 V
Overload current 1 A
Controller type SMC-3
DV/DT protection 1000V/µs for power circuit
Repetitive peak voltage 1400V per UL/CSA/NEMA for power circuit
Operating frequency 50/60 Hz per UL/CSA/NEMA for power circuit
Line connected motor power, max 1.1 kW @ 380/400/415V AC @ 50Hz, 3-phase
Delta connected motor power, max 1Hp @ 230V AC, 60 Hz, 3-phase
Overvoltage category III per IEC for side mount auxiliary contacts
Rated impulse voltage 6 kV for power circuit
Dielectric withstand 2500V AC per IEC for power circuit
Line connected motor current 1...3A @ 380/400/415/460V AC, 3-phase
Delta connected motor current 1.7...5.1A @ 380/400/415/460V AC, 3-phase
Insulation voltage Rated 600V AC per UL/CSA/NEMA for power circuit
Rated operational voltage 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Rated control power during start with fan 215mA @ 120V AC/180mA @ 240V AC, 800mA @ 24V DC/660mA @ 24V AC
Input OFF-state current <10 mA, <12 mA @ input OFF-state voltage (IN1, IN2) for control circuit
Short-circuit protection device list Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Number of contacts TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
High capacity available fault current, max 69kA @ 600V, maximum current 10 A time delay Class J or Class L fuse for inside delta connected motors
Type of current TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
Conventional thermal current (Ith) TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of control circuit TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Type of contacts TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Utilization category TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Rated operational current, max TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Standard controller feature Soft stop
Standard available fault current, max 5 kA @ maximum standard fuse 15 A for delta device opsal current rating
Integrated motor overload protection True
Short circuit protection device performance (SCPD) type Type 1
Selectable overload trip class Trip Class 10, 15, or 20
Selectable start times 2, 5, 10, 15, 20, 25, or 30 s
Input OFF-state voltage (IN1, IN2), max 40V AC @ 17V DC/12V AC for control circuit
Selectable current limit 150%, 250%, 350%, and 450% of full load current
Input ON-state voltage, during start (IN1, IN2) 85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Rated control power during start without fan 205mA @ 120V AC/145mA @ 240V AC, 705mA @ 24V DC/580mA @ 24V AC
Input ON-state current (IN1, IN2) 9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Degree of protection (IP) IP2X
Weight 0.86 kg
Shock Opsal: 15 G
Width 44.8 mm (1.76 in)
Depth 110 mm (4.33 in)
Height 139.7 mm (5.5 in)
Cable size 2.5...25 mm² (14...4 AWG) for line power terminals
Vibration Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Make TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
Break TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Tightening torque 2.3...3.4 Nm (30 in-lb) for line power terminals, 4.0 Nm (35 in-lb) if 25 mm² (4 AWG) wire in top terminal for line power terminal
Internal bypass True
Function Single direction
Selectable kick start - 450% FLA 0, 0.5, 1.0, or 1.5 s
Selectable initial torque 15%, 25%, 35%, and 65% of locked rotor torque
Selectable soft stop Off, 100%, 200%, or 300% of the start time setting when wired
Steady state heat dissipation 11 W
Storage and transportation temperature -25 °C
Rated surrounding temperature range without derating -5 °C
Humidity 5...95% noncondensing
Operating temperature Open: -5 to 50 °C (23 to 122 °F)
EMC emission levels Radiated emission: Class A per IEC
EMC immunity levels Surge transient: per EN/IEC 60947-4-2 per IEC
Altitude 2000 m
Pollution degree 2
Mounting hole size 4.6 mm
Number of poles Equipment is designed for 3-phase only for power circuit
Enclosure Open type
Drawings
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
文档
OL Trip Curves and Starts per Hour Curves General
--
Short Circuit Ratings Data Sheet General
--
Wiring General
--
Dimension Sheet (PDF) General
--
Dimension Sheet (Catalog) General
--
Product Cutsheet General
--
Features and Modes of Operation General
--
Specifications Sheet General
--
150-in044_-en-e Installation Instructions
150-IN044
150-td009_-en-p Technical Data
150-TD009
类型 资源 发布
General OL Trip Curves and Starts per Hour Curves --
General Short Circuit Ratings Data Sheet --
General Wiring --
General Dimension Sheet (PDF) --
General Dimension Sheet (Catalog) --
General Product Cutsheet --
General Features and Modes of Operation --
General Specifications Sheet --
Installation Instructions 150-in044_-en-e 150-IN044
Technical Data 150-td009_-en-p 150-TD009
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Chevron RightChevron Right Search the Literature Library Chevron RightChevron Right
认证
China CCC Eurasion Economic Community Australian RCM
  • China CCC
  • Eurasion Economic Community
  • Australian RCM

This product was certified with the above certifications as of 2025-07-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Accessories
每页条目数:
1-1 的 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Loading
Find your nearest distributor
Change location
EmailEmail
PhonePhone
Find a partner Chevron RightChevron Right
SMC-3 3A Smart Motor Controller
CloseClose
150-C3NBD
关闭
打印
Chevron LeftChevron Left
Allen-Bradley 150-C3NBD product image
Chevron RightChevron Right
Chevron LeftChevron Left
Allen-Bradley 150-C3NBD product image
Allen-Bradley 150-C3NBD product image
Chevron RightChevron Right
手机:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页 Chevron RightChevron Right
  2. Chevron LeftChevron Left 产品 Chevron RightChevron Right
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose