SMC-3 25A Smart Motor Controller

PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Catalog #: 150-C25NCD
Lifecycle status: Active
Allen-Bradley 150-C25NCD product image
Allen-Bradley 150-C25NCD product image
Allen-Bradley 150-C25NCD product image
Allen Bradley
PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Lifecycle status: Active
Add to BoM
  • Get Support
Technical Specifications
Drawings
Documents
Certifications
Accessories
Alternative Products
Technotes
Product Family SMC-3
With display False
Voltage type for actuating AC/DC
Rated operating voltage Ue 200 V
Rated control supply voltage at AC 50 Hz 100 V
Rated control supply voltage at AC 60 Hz 100 V
Overload current 8.3 A
Controller type SMC-3
DV/DT protection 1000V/µs for power circuit
Repetitive peak voltage 1600V per UL/CSA/NEMA for power circuit
Operating frequency 50/60 Hz per UL/CSA/NEMA for power circuit
Line connected motor power, max 7.5...20Hp @ 575V AC, 60 Hz, 3-phase
Delta connected motor power, max 7.5...22 kW @ 500V AC @ 50Hz, 3-phase
Overvoltage category III per IEC for side mount auxiliary contacts
Rated impulse voltage 6 kV for power circuit
Dielectric withstand 2500V AC per IEC for power circuit
Line connected motor current 9.2...25A @ 500/575V AC, 3-phase
Delta connected motor current 14.3...43A @ 500/575V AC, 3-phase
Insulation voltage Rated 600V AC per UL/CSA/NEMA for power circuit
Rated operational voltage 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Rated control power during start with fan 215mA @ 120V AC/180mA @ 240V AC, 800mA @ 24V DC/660mA @ 24V AC
Input OFF-state current <10 mA, <12 mA @ input off-state voltage (IN1, IN2) for control circuit
Short-circuit protection device list Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Number of contacts TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
High capacity available fault current, max 70kA @ 600V, maximum current 90 A time delay Class J or Class L fuse for inside delta connected motors
Type of current TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
Conventional thermal current (Ith) TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of control circuit TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Type of contacts TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Utilization category TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Rated operational current, max TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Standard controller feature Soft stop
Standard available fault current, max 5 kA @ maximum standard fuse 150 A for delta device opsal current rating
Integrated motor overload protection True
Short circuit protection device performance (SCPD) type Type 1
Selectable overload trip class Trip Class 10, 15, or 20
Selectable start times 2, 5, 10, 15, 20, 25, or 30 s
Input OFF-state voltage (IN1, IN2), max 40V AC @ 17V DC/12V AC for control circuit
Selectable current limit 150%, 250%, 350%, and 450% of full load current
Input ON-state voltage, during start (IN1, IN2) 85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Rated control power during start without fan 205mA @ 120V AC/145mA @ 240V AC, 705mA @ 24V DC/580mA @ 24V AC
Input ON-state current (IN1, IN2) 9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Degree of protection (IP) IP2X
Weight 0.86 kg
Shock Opsal: 15 G
Width 44.8 mm (1.76 in)
Depth 110 mm (4.33 in)
Height 139.7 mm (5.5 in)
Cable size 2.5...25 mm² (14...4 AWG) for line power terminals
Vibration Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Make TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
Break TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Tightening torque 2.3...3.4 Nm (30 in-lb) for line power terminals, 4.0 Nm (35 in-lb) if 25 mm² (4 AWG) wire in top terminal for line power terminal
Internal bypass True
Function Single direction
Selectable kick start - 450% FLA 0, 0.5, 1.0, or 1.5 s
Selectable initial torque 15%, 25%, 35%, and 65% of locked rotor torque
Selectable soft stop Off, 100%, 200%, or 300% of the start time setting when wired
Steady state heat dissipation 17 W
Storage and transportation temperature -25 °C
Rated surrounding temperature range without derating -5 °C
Humidity 5...95% noncondensing
Operating temperature Open: -5 to 50 °C (23 to 122 °F)
EMC emission levels Radiated emission: Class A per IEC
EMC immunity levels Surge transient: per EN/IEC 60947-4-2 per IEC
Altitude 2000 m
Pollution degree 2
Mounting hole size 4.6 mm
Number of poles Equipment is designed for 3-phase only for power circuit
Enclosure Open type
Sales Info
Repairable NOT_REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 10.0
Lead Time 21
Dimension Width 18.001
Dimension Length 18.999
Stock Status NON_STOCKED
Weight 0.9
Weight Unit KG
Dimension Unit CM
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
类型 资源 发布
General Dimension Sheet (Catalog) --
General Features and Modes of Operation --
General OL Trip Curves and Starts per Hour Curves --
General Product Cutsheet --
General Wiring --
General Specifications Sheet --
General Dimension Sheet (PDF) --
General Short Circuit Ratings Data Sheet --
Installation Instructions 150-in044_-en-e 150-IN044
Technical Data 150-td009_-en-p 150-TD009
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Chevron RightChevron Right Search the Literature Library Chevron RightChevron Right
China CCC Eurasion Economic Community Australian RCM
  • China CCC
  • Eurasion Economic Community
  • Australian RCM

This product was certified with the above certifications as of 2025-06-05. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

每页条目数:
1-1 的 1
每页条目数:
1-1 的 1
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Technical Specifications
Product Family SMC-3
With display False
Voltage type for actuating AC/DC
Rated operating voltage Ue 200 V
Rated control supply voltage at AC 50 Hz 100 V
Rated control supply voltage at AC 60 Hz 100 V
Overload current 8.3 A
Controller type SMC-3
DV/DT protection 1000V/µs for power circuit
Repetitive peak voltage 1600V per UL/CSA/NEMA for power circuit
Operating frequency 50/60 Hz per UL/CSA/NEMA for power circuit
Line connected motor power, max 7.5...20Hp @ 575V AC, 60 Hz, 3-phase
Delta connected motor power, max 7.5...22 kW @ 500V AC @ 50Hz, 3-phase
Overvoltage category III per IEC for side mount auxiliary contacts
Rated impulse voltage 6 kV for power circuit
Dielectric withstand 2500V AC per IEC for power circuit
Line connected motor current 9.2...25A @ 500/575V AC, 3-phase
Delta connected motor current 14.3...43A @ 500/575V AC, 3-phase
Insulation voltage Rated 600V AC per UL/CSA/NEMA for power circuit
Rated operational voltage 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Rated control power during start with fan 215mA @ 120V AC/180mA @ 240V AC, 800mA @ 24V DC/660mA @ 24V AC
Input OFF-state current <10 mA, <12 mA @ input off-state voltage (IN1, IN2) for control circuit
Short-circuit protection device list Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Number of contacts TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
High capacity available fault current, max 70kA @ 600V, maximum current 90 A time delay Class J or Class L fuse for inside delta connected motors
Type of current TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
Conventional thermal current (Ith) TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of control circuit TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Type of contacts TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Utilization category TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Rated operational current, max TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Standard controller feature Soft stop
Standard available fault current, max 5 kA @ maximum standard fuse 150 A for delta device opsal current rating
Integrated motor overload protection True
Short circuit protection device performance (SCPD) type Type 1
Selectable overload trip class Trip Class 10, 15, or 20
Selectable start times 2, 5, 10, 15, 20, 25, or 30 s
Input OFF-state voltage (IN1, IN2), max 40V AC @ 17V DC/12V AC for control circuit
Selectable current limit 150%, 250%, 350%, and 450% of full load current
Input ON-state voltage, during start (IN1, IN2) 85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Rated control power during start without fan 205mA @ 120V AC/145mA @ 240V AC, 705mA @ 24V DC/580mA @ 24V AC
Input ON-state current (IN1, IN2) 9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Degree of protection (IP) IP2X
Weight 0.86 kg
Shock Opsal: 15 G
Width 44.8 mm (1.76 in)
Depth 110 mm (4.33 in)
Height 139.7 mm (5.5 in)
Cable size 2.5...25 mm² (14...4 AWG) for line power terminals
Vibration Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Make TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
Break TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Tightening torque 2.3...3.4 Nm (30 in-lb) for line power terminals, 4.0 Nm (35 in-lb) if 25 mm² (4 AWG) wire in top terminal for line power terminal
Internal bypass True
Function Single direction
Selectable kick start - 450% FLA 0, 0.5, 1.0, or 1.5 s
Selectable initial torque 15%, 25%, 35%, and 65% of locked rotor torque
Selectable soft stop Off, 100%, 200%, or 300% of the start time setting when wired
Steady state heat dissipation 17 W
Storage and transportation temperature -25 °C
Rated surrounding temperature range without derating -5 °C
Humidity 5...95% noncondensing
Operating temperature Open: -5 to 50 °C (23 to 122 °F)
EMC emission levels Radiated emission: Class A per IEC
EMC immunity levels Surge transient: per EN/IEC 60947-4-2 per IEC
Altitude 2000 m
Pollution degree 2
Mounting hole size 4.6 mm
Number of poles Equipment is designed for 3-phase only for power circuit
Enclosure Open type
Sales Info
Repairable NOT_REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 10.0
Lead Time 21
Dimension Width 18.001
Dimension Length 18.999
Stock Status NON_STOCKED
Weight 0.9
Weight Unit KG
Dimension Unit CM
Drawings
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
文档
Dimension Sheet (Catalog) General
--
Features and Modes of Operation General
--
OL Trip Curves and Starts per Hour Curves General
--
Product Cutsheet General
--
Wiring General
--
Specifications Sheet General
--
Dimension Sheet (PDF) General
--
Short Circuit Ratings Data Sheet General
--
150-in044_-en-e Installation Instructions
150-IN044
150-td009_-en-p Technical Data
150-TD009
类型 资源 发布
General Dimension Sheet (Catalog) --
General Features and Modes of Operation --
General OL Trip Curves and Starts per Hour Curves --
General Product Cutsheet --
General Wiring --
General Specifications Sheet --
General Dimension Sheet (PDF) --
General Short Circuit Ratings Data Sheet --
Installation Instructions 150-in044_-en-e 150-IN044
Technical Data 150-td009_-en-p 150-TD009
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Chevron RightChevron Right Search the Literature Library Chevron RightChevron Right
认证
China CCC Eurasion Economic Community Australian RCM
  • China CCC
  • Eurasion Economic Community
  • Australian RCM

This product was certified with the above certifications as of 2025-06-05. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Accessories
每页条目数:
1-1 的 1
Alternative Products
每页条目数:
1-1 的 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Loading
Find your nearest distributor
Change location
EmailEmail
PhonePhone
Find a partner Chevron RightChevron Right
SMC-3 25A Smart Motor Controller
CloseClose
150-C25NCD
关闭
打印
Chevron LeftChevron Left
Allen-Bradley 150-C25NCD product image
Chevron RightChevron Right
Chevron LeftChevron Left
Allen-Bradley 150-C25NCD product image
Allen-Bradley 150-C25NCD product image
Chevron RightChevron Right
手机:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页 Chevron RightChevron Right
  2. Chevron LeftChevron Left 产品 Chevron RightChevron Right
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose