1494C-DJ622-A4-B-D-E-F-G
200 A Flange Mtd Cable Switch
Rockwell Automation announces that as of May 31, 2019, the 200 A Flange Mtd Cable Switch will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
May 31, 2019
替代类别:
Engineering Replacement
Rockwell Automation announces that as of May 31, 2019, the 200 A Flange Mtd Cable Switch will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
May 31, 2019
替代类别:
Engineering Replacement
| Number of auxiliary contacts as normally open contact |
1
|
|---|---|
| Number of auxiliary contacts as normally closed contact |
1
|
| Rated permanent current Iu |
200 A
|
| Max. rated operation voltage Ue AC |
600 V
|
| Type of control element |
Long turning handle
|
| Switching frequency, max |
300 ops/m
|
| Insulation voltage |
Rated 660V per IEC
|
| Fuse/fuse clip type |
Type J fuse clips
|
| Number of switches |
1
|
| Motor drive integrated |
No
|
| Motor drive optional |
No
|
| Voltage release optional |
No
|
| Continuous current (Ithe) rating |
200A @ 600V AC per UL/CSA/NEMA
|
| Type of electrical connection of main circuit |
Screw connection
|
| KW rating (AC23), max |
90 kW @ 440V AC @ 50Hz per IEC
|
| Hp rating |
60Hp @ 230V AC, 60 Hz per UL/CSA/NEMA
|
| Switch and fuse rating (fusing) |
600V 200 A switch, 200 A clips
|
| Short circuit withstand capability |
200000A @ 600V AC: with Class J or Class R fuses
|
| Low level auxiliary 1 NO or 1 NC contact rating |
C300, R150 per NEMA/EEMAC
|
| Standard auxiliary 1 NO or 1 NC contact rating |
AC 15, DC 13 to IEC/EN60947-5-1 and UL 508, 17V @ 5mA minimum per IEC
|
| Dielectric strength |
2200V @ 1min
|
| Electrical life cycle |
6000 ops at rated current
|
| Standard electrical interlock 1 NO and 1 NC contact rating |
20A @ 480V AC, 0.25A @ 250V DC per NEMA/EEMAC
|
| Standard electrical interlock 2 NO and 2 NC contact rating |
20A @ 480V AC, 0.25A @ 250V DC per NEMA/EEMAC
|
| Version as emergency stop installation |
No
|
|---|---|
| Mechanical life operations |
8000 (typical)
|
| Version as safety switch |
No
|
| Recommended torque |
Lug to terminal: 175 in-lb
|
| Version as reversing switch |
No
|
| Version as main switch |
Yes
|
| Version as maintenance-/service switch |
Yes
|
| Factory option |
Stainless steel handle
|
| Degree of protection |
Operating handles: Type 4, 4X
|
| Material |
Switches, mechanisms and accessory kits: zinc-plated steel, RoHS compliant finish
|
| Suitable for front mounting 4-hole |
No
|
|---|---|
| Suitable for front mounting centre |
No
|
| Colour control element |
Black
|
| Device construction |
Built-in device fixed built-in technique
|
| Disconnect mechanism |
Right-hand mechanism
|
| Suitable for floor mounting |
No
|
| Suitable for distribution board installation |
Yes
|
| Suitable for intermediate mounting |
Yes
|
| Cable mechanism |
Cable operated mechanism 4 ft
|
| Terminals |
3/8 in-24 screw-lug, copper
|
| Conductor size |
#6...4 AWG (16...95 mm²)
|
| Switch body material |
Glass-filled thermoset plastic
|
| Altitude |
2000 m per IEC 947-1
|
|---|---|
| Ambient enclosed temperature |
-20 °C
|
| Ambient storage temperature |
-40 °C
|
| Relative humidity |
90% @ 20°C (68 °F) and 50% @ 40°C (104 °F) per IEC 947-1
|
| Ambient open temperature |
-20 °C
|
| 技术数据 | 出版 |
|---|---|
| 1494-td002_-en-p | 1494-TD002 |
技术规格
| Number of auxiliary contacts as normally open contact |
1
|
|---|---|
| Number of auxiliary contacts as normally closed contact |
1
|
| Rated permanent current Iu |
200 A
|
| Max. rated operation voltage Ue AC |
600 V
|
| Type of control element |
Long turning handle
|
| Switching frequency, max |
300 ops/m
|
| Insulation voltage |
Rated 660V per IEC
|
| Fuse/fuse clip type |
Type J fuse clips
|
| Number of switches |
1
|
| Motor drive integrated |
No
|
| Motor drive optional |
No
|
| Voltage release optional |
No
|
| Continuous current (Ithe) rating |
200A @ 600V AC per UL/CSA/NEMA
|
| Type of electrical connection of main circuit |
Screw connection
|
| KW rating (AC23), max |
90 kW @ 440V AC @ 50Hz per IEC
|
| Hp rating |
60Hp @ 230V AC, 60 Hz per UL/CSA/NEMA
|
| Switch and fuse rating (fusing) |
600V 200 A switch, 200 A clips
|
| Short circuit withstand capability |
200000A @ 600V AC: with Class J or Class R fuses
|
| Low level auxiliary 1 NO or 1 NC contact rating |
C300, R150 per NEMA/EEMAC
|
| Standard auxiliary 1 NO or 1 NC contact rating |
AC 15, DC 13 to IEC/EN60947-5-1 and UL 508, 17V @ 5mA minimum per IEC
|
| Dielectric strength |
2200V @ 1min
|
| Electrical life cycle |
6000 ops at rated current
|
| Standard electrical interlock 1 NO and 1 NC contact rating |
20A @ 480V AC, 0.25A @ 250V DC per NEMA/EEMAC
|
| Standard electrical interlock 2 NO and 2 NC contact rating |
20A @ 480V AC, 0.25A @ 250V DC per NEMA/EEMAC
|
| Version as emergency stop installation |
No
|
|---|---|
| Mechanical life operations |
8000 (typical)
|
| Version as safety switch |
No
|
| Recommended torque |
Lug to terminal: 175 in-lb
|
| Version as reversing switch |
No
|
| Version as main switch |
Yes
|
| Version as maintenance-/service switch |
Yes
|
| Factory option |
Stainless steel handle
|
| Degree of protection |
Operating handles: Type 4, 4X
|
| Material |
Switches, mechanisms and accessory kits: zinc-plated steel, RoHS compliant finish
|
| Suitable for front mounting 4-hole |
No
|
|---|---|
| Suitable for front mounting centre |
No
|
| Colour control element |
Black
|
| Device construction |
Built-in device fixed built-in technique
|
| Disconnect mechanism |
Right-hand mechanism
|
| Suitable for floor mounting |
No
|
| Suitable for distribution board installation |
Yes
|
| Suitable for intermediate mounting |
Yes
|
| Cable mechanism |
Cable operated mechanism 4 ft
|
| Terminals |
3/8 in-24 screw-lug, copper
|
| Conductor size |
#6...4 AWG (16...95 mm²)
|
| Switch body material |
Glass-filled thermoset plastic
|
| Altitude |
2000 m per IEC 947-1
|
|---|---|
| Ambient enclosed temperature |
-20 °C
|
| Ambient storage temperature |
-40 °C
|
| Relative humidity |
90% @ 20°C (68 °F) and 50% @ 40°C (104 °F) per IEC 947-1
|
| Ambient open temperature |
-20 °C
|
文档
|
1494-td002_-en-p
技术数据
1494-TD002 |
| 技术数据 | 出版 |
|---|---|
| 1494-td002_-en-p | 1494-TD002 |
替代产品
技术说明
Loading