Loading
  • alt text
  • alt text
alt text
alt text
1426-M5E-DNT

Powermonitor 5000 Base Quality Meter

PrintPrint
打印
EmailEmail
共享
Product RegistrationProduct Registration
QR code
Allen-Bradley 1426-M5E-DNT product image
Allen-Bradley 1426-M5E-DNT product image
Allen-Bradley 1426-M5E-DNT product image
生命周期状态: 活跃
Product at a glance
Product Registration
生命周期状态: 活跃
Product at a glance
Product Registration
添加到BoM
  • 注册产品
  • 寻找支持
技术规格
常规
Environmental Specifications
Hardware Features
Control Relay
Measured Parameters
Input/output specifications
Other Functions
Input/Output Specifications
General specifications
Electrical
Dimension
Logging Functions
Communication
图纸
文档
认证
配件
技术说明
Accuracy
0.20%
Alarm
Yes
Communications
DeviceNet and EtherNet/IP
Frequency Rating
40-75Hz
Interface
Webpage
Metering Voltage
600VLL AC
Output
4 Digital Relays
Vibration
2 G
Shock
50 G, nonoperating
Dielectric withstand
UL61010, EN61010
Storage temperature
-40 to 85 °C
Operating temperature
-20 to 70 °C
Altitude
2000 m, max
Installation location
Indoor use only
Humidity
5...95% noncondensing
Height
132 mm
Width
185 mm
Control power and ground wiring terminals
• 120...240V AC @ 50/60Hz, or 120...240V DC • 24V DC
Virtual wiring correction indicator
Indicates that a virtual wiring correction command has been applied to resolve wiring errors without rewiring
Voltage sensing wiring terminals
• Direct connect to up to 690V AC 3-phase line to line • Maximum nominal line to ground voltage 690 • Use potential transformers (PTs) for higher voltages • Neutral voltage and ground voltage connections
Device status indicators
• Device status - OFF: No control power - Flashing GREEN/RED: Self-test - Flashing GREEN: Power monitor has not been configured - GREEN: Power monitor is running - Flashing RED: Power monitor has detected a recoverable minor fault - RED: Power monitor has detected a non-recoverable major fault
Ethernet network port - standard RJ45 jack with status indicators
Ethernet port hardware is included on all models. these protocols and functions are supported: • EtherNet/IP™ network • HTML web page for configuration and data access ethernet indicators • LNK indicator - Solid GREEN: IP link established - Off: no link established • ACT indicator - Flashing YELLOW: data present on Ethernet port - Off: no data activity present
USB host port
USB standard A receptacle. Not used in this model.
Power
•Power status - OFF: no control power - GREEN: control power is present
Current sensing wiring terminals
Nominal input current 5 A, Use current transformers (CTs) to connect to power system
Configuration lock switch
When enabled, this switch helps prevent changes in configuration that can affect revenue accuracy.
USB device port
The USB device port is a USB Mini-B receptacle that accepts standard USB Mini-B plugs, for connection to a host device, such as a notebook computer.
Status input, KYZ output, and control relay wiring terminals
• Four internally powered (24V DC) status inputs • Status input 2 can be used for demand period synchronization • KYZ DPDT solid-state relay for signaling use • Three DPDT control relays
Network status indicators
• Network status (Native Ethernet port) - OFF: No control power - Flashing GREEN/RED: Self-test - Flashing GREEN: No CIP connection - Solid GREEN: CIP connection established - Flashing RED: CIP connection timed out - Solid RED: Duplicate IP address detected
Optional communication port
DeviceNet and ControlNet networks • Module status - OFF: No control power - Flashing GREEN/RED: Self-test - Flashing GREEN: Power monitor has not been configured - GREEN: Power monitor is running - Flashing RED: Power monitor has detected a recoverable minor fault - RED: Power monitor has detected a non-recoverable major fault • Network status - OFF: No control power - Flashing GREEN/RED: Self-test - Flashing GREEN: No CIP connection - Solid GREEN: CIP connection established - Flashing RED: CIP connection timed out - Solid RED: Duplicate address detected
IC rating class
UL 508, CSA 22.2 @ DC: Q300
Resistive load switching
10A @ 24V DC, maximum
Load switching
100mA @ 5V AC, 50/60 Hz, RMS, minimum
Motor load switching
1/3HP @ 125V AC, 50/60 Hz, RMS, maximum
Make values
(Inductive load) 30A @ 120V AC, 50/60 Hz, RMS, maximum
Break values
(Inductive load) 3A @ 120V AC, 50/60 Hz, RMS, maximum
Crest factor
V-V, V-N, and I, per phase: Yes
Reactive energy (kVARh)
Yes
Frequency
Nominal: 60 Hz
Real energy (kWh)
Yes
Reactive power (kVAR)
Yes
Real power (kW)
Yes
Apparent power (kVA)
Yes
Real power demand (kW)
Yes
Reactive power demand (kVAR)
Yes
Apparent power demand (kVA)
Yes
Demand power factor
Yes
Projected kW demand
Yes
Projected kVAR demand
Yes
Projected kVA demand
Yes
Voltage unbalance
Yes
Current unbalance
Yes
Voltage, L-L and L-N
Yes
Current per phase and total
Yes
Symmetrical component analysis
Yes
True power factor per phase and total
Yes
Displacement power factor per phase and total
Yes
Apparent energy (kVAh)
Yes
Demand, amps
Yes
Projected amps demand
Yes
Current consumption
Yes
Control power
12VA @ 24V DC
Current sense inputs: I1, I2, I3
Accuracy: ±0.1% @ 25°C 50/60 Hz unity power factor
Status inputs
Yes
Configurable via webpage
Yes
CIP energy object
Yes
Security
Yes
Wiring diagnostics
Yes
Virtual wiring correction
Yes
Network time synchronization
Yes
Network demand synchronization
Yes
IEEE 1588 precision time protocol
Yes
Pulse (digital) output (relay and KYZ)
Yes
Setpoint programming
Yes
Sag and swell detection
Yes
Web page
Yes
K-factor
Yes
Revenue accuracy
Yes
Total harmonic distortion (THD)
Yes
Control power
12VA @ 24V DC
Current sense inputs: I1, I2, I3
Accuracy: ±0.1% @ 25°C 50/60 Hz unity power factor
Power functions
• ANSI C12.20 -2010 class 0.2 clause 5.5.4 • EN 62053-22 -2003 class 0.2 accuracy clause 8
Demand functions
• ANSI C12.20 -2010 class 0.2 clause 5.5.4 • EN 62053-22 -2003 class 0.2 accuracy clause 8
Metering update rates
One update per line cycle, 1024 sAles per cycle per channel
VG
Connect to power system earth ground only, This connection is a functional ground.
Energy functions
• ANSI C12.20 -2010 class 0.2 clause 5.5.4 • EN 62053-22 -2003 class 0.2 accuracy clause 8
Description
PowerMonitor 5000 M5 unit with native ethernet and optional devicenet network communication
Ampere meter
Yes
Blind power meter
Yes
Frequency meter
Yes
Pulse counter
Yes
Voltmeter
Yes
Effective power measurement device
Yes
Depth
178 mm
Time of use log
Yes
Energy log
Yes
Minimum/maximum log
Yes
Load factor log
Yes
Alarm log
Yes
Data log
Yes
Event log
Yes
Setpoint log
Yes
EtherNet/IP
Yes
Devicenet
Yes
图纸
3D STEP Model (STP) 下载 (ZIP)
2D Drawing (PDF) 下载 (PDF)
3 DImensional Drawing (PDF) 下载 (PDF)
Product Drawing Drawing (DXF)
图纸
3D STEP Model (STP) 下载 (ZIP)
2D Drawing (PDF) 下载 (PDF)
3 DImensional Drawing (PDF) 下载 (PDF)
Product Drawing Drawing (DXF)
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
类型 资源 出版
User Manual 1426-um001_-en-p 1426-UM001
常规 PowerMonitor 5000 Product Profile 1426-PP001
常规 PowerMonitor 5000 USB Driver Installation and Configuration Instructions 1426-IN001
常规 Product Cutsheet --
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
访问技术文档中心 搜索文献资料库
Australian RCM UKCA DOC
  • Australian RCM
  • UKCA DOC

This product was certified with the above certifications as of 2025-09-10. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

每页项目:
1-1 关于 1
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
技术规格
Accuracy
0.20%
Alarm
Yes
Communications
DeviceNet and EtherNet/IP
Frequency Rating
40-75Hz
Interface
Webpage
Metering Voltage
600VLL AC
Output
4 Digital Relays
Vibration
2 G
Shock
50 G, nonoperating
Dielectric withstand
UL61010, EN61010
Storage temperature
-40 to 85 °C
Operating temperature
-20 to 70 °C
Altitude
2000 m, max
Installation location
Indoor use only
Humidity
5...95% noncondensing
Height
132 mm
Width
185 mm
Control power and ground wiring terminals
• 120...240V AC @ 50/60Hz, or 120...240V DC • 24V DC
Virtual wiring correction indicator
Indicates that a virtual wiring correction command has been applied to resolve wiring errors without rewiring
Voltage sensing wiring terminals
• Direct connect to up to 690V AC 3-phase line to line • Maximum nominal line to ground voltage 690 • Use potential transformers (PTs) for higher voltages • Neutral voltage and ground voltage connections
Device status indicators
• Device status - OFF: No control power - Flashing GREEN/RED: Self-test - Flashing GREEN: Power monitor has not been configured - GREEN: Power monitor is running - Flashing RED: Power monitor has detected a recoverable minor fault - RED: Power monitor has detected a non-recoverable major fault
Ethernet network port - standard RJ45 jack with status indicators
Ethernet port hardware is included on all models. these protocols and functions are supported: • EtherNet/IP™ network • HTML web page for configuration and data access ethernet indicators • LNK indicator - Solid GREEN: IP link established - Off: no link established • ACT indicator - Flashing YELLOW: data present on Ethernet port - Off: no data activity present
USB host port
USB standard A receptacle. Not used in this model.
Power
•Power status - OFF: no control power - GREEN: control power is present
Current sensing wiring terminals
Nominal input current 5 A, Use current transformers (CTs) to connect to power system
Configuration lock switch
When enabled, this switch helps prevent changes in configuration that can affect revenue accuracy.
USB device port
The USB device port is a USB Mini-B receptacle that accepts standard USB Mini-B plugs, for connection to a host device, such as a notebook computer.
Status input, KYZ output, and control relay wiring terminals
• Four internally powered (24V DC) status inputs • Status input 2 can be used for demand period synchronization • KYZ DPDT solid-state relay for signaling use • Three DPDT control relays
Network status indicators
• Network status (Native Ethernet port) - OFF: No control power - Flashing GREEN/RED: Self-test - Flashing GREEN: No CIP connection - Solid GREEN: CIP connection established - Flashing RED: CIP connection timed out - Solid RED: Duplicate IP address detected
Optional communication port
DeviceNet and ControlNet networks • Module status - OFF: No control power - Flashing GREEN/RED: Self-test - Flashing GREEN: Power monitor has not been configured - GREEN: Power monitor is running - Flashing RED: Power monitor has detected a recoverable minor fault - RED: Power monitor has detected a non-recoverable major fault • Network status - OFF: No control power - Flashing GREEN/RED: Self-test - Flashing GREEN: No CIP connection - Solid GREEN: CIP connection established - Flashing RED: CIP connection timed out - Solid RED: Duplicate address detected
IC rating class
UL 508, CSA 22.2 @ DC: Q300
Resistive load switching
10A @ 24V DC, maximum
Load switching
100mA @ 5V AC, 50/60 Hz, RMS, minimum
Motor load switching
1/3HP @ 125V AC, 50/60 Hz, RMS, maximum
Make values
(Inductive load) 30A @ 120V AC, 50/60 Hz, RMS, maximum
Break values
(Inductive load) 3A @ 120V AC, 50/60 Hz, RMS, maximum
Crest factor
V-V, V-N, and I, per phase: Yes
Reactive energy (kVARh)
Yes
Frequency
Nominal: 60 Hz
Real energy (kWh)
Yes
Reactive power (kVAR)
Yes
Real power (kW)
Yes
Apparent power (kVA)
Yes
Real power demand (kW)
Yes
Reactive power demand (kVAR)
Yes
Apparent power demand (kVA)
Yes
Demand power factor
Yes
Projected kW demand
Yes
Projected kVAR demand
Yes
Projected kVA demand
Yes
Voltage unbalance
Yes
Current unbalance
Yes
Voltage, L-L and L-N
Yes
Current per phase and total
Yes
Symmetrical component analysis
Yes
True power factor per phase and total
Yes
Displacement power factor per phase and total
Yes
Apparent energy (kVAh)
Yes
Demand, amps
Yes
Projected amps demand
Yes
Current consumption
Yes
Control power
12VA @ 24V DC
Current sense inputs: I1, I2, I3
Accuracy: ±0.1% @ 25°C 50/60 Hz unity power factor
Status inputs
Yes
Configurable via webpage
Yes
CIP energy object
Yes
Security
Yes
Wiring diagnostics
Yes
Virtual wiring correction
Yes
Network time synchronization
Yes
Network demand synchronization
Yes
IEEE 1588 precision time protocol
Yes
Pulse (digital) output (relay and KYZ)
Yes
Setpoint programming
Yes
Sag and swell detection
Yes
Web page
Yes
K-factor
Yes
Revenue accuracy
Yes
Total harmonic distortion (THD)
Yes
Control power
12VA @ 24V DC
Current sense inputs: I1, I2, I3
Accuracy: ±0.1% @ 25°C 50/60 Hz unity power factor
Power functions
• ANSI C12.20 -2010 class 0.2 clause 5.5.4 • EN 62053-22 -2003 class 0.2 accuracy clause 8
Demand functions
• ANSI C12.20 -2010 class 0.2 clause 5.5.4 • EN 62053-22 -2003 class 0.2 accuracy clause 8
Metering update rates
One update per line cycle, 1024 sAles per cycle per channel
VG
Connect to power system earth ground only, This connection is a functional ground.
Energy functions
• ANSI C12.20 -2010 class 0.2 clause 5.5.4 • EN 62053-22 -2003 class 0.2 accuracy clause 8
Description
PowerMonitor 5000 M5 unit with native ethernet and optional devicenet network communication
Ampere meter
Yes
Blind power meter
Yes
Frequency meter
Yes
Pulse counter
Yes
Voltmeter
Yes
Effective power measurement device
Yes
Depth
178 mm
Time of use log
Yes
Energy log
Yes
Minimum/maximum log
Yes
Load factor log
Yes
Alarm log
Yes
Data log
Yes
Event log
Yes
Setpoint log
Yes
EtherNet/IP
Yes
Devicenet
Yes
图纸
图纸
3D STEP Model (STP) 下载 (ZIP)
2D Drawing (PDF) 下载 (PDF)
3 DImensional Drawing (PDF) 下载 (PDF)
Product Drawing Drawing (DXF)
图纸
3D STEP Model (STP) 下载 (ZIP)
2D Drawing (PDF) 下载 (PDF)
3 DImensional Drawing (PDF) 下载 (PDF)
Product Drawing Drawing (DXF)
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
1426-um001_-en-p User Manual
1426-UM001
PowerMonitor 5000 Product Profile 常规
1426-PP001
PowerMonitor 5000 USB Driver Installation and Configuration Instructions 常规
1426-IN001
Product Cutsheet 常规
--
类型 资源 出版
User Manual 1426-um001_-en-p 1426-UM001
常规 PowerMonitor 5000 Product Profile 1426-PP001
常规 PowerMonitor 5000 USB Driver Installation and Configuration Instructions 1426-IN001
常规 Product Cutsheet --
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
访问技术文档中心 搜索文献资料库
认证
Australian RCM UKCA DOC
  • Australian RCM
  • UKCA DOC

This product was certified with the above certifications as of 2025-09-10. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

配件
每页项目:
1-1 关于 1
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
Loading
寻找最近经销商
Contact your distributor in {0}
更改位置
EmailEmail
PhonePhone
寻找合作伙伴
Powermonitor 5000 Base Quality Meter
CloseClose
1426-M5E-DNT
关闭
打印
Chevron LeftChevron Left
Allen-Bradley 1426-M5E-DNT product image
Chevron LeftChevron Left
Allen-Bradley 1426-M5E-DNT product image
Allen-Bradley 1426-M5E-DNT product image
电话:
呼叫
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页
  2. Chevron LeftChevron Left 产品
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose