Loading
View all 140M IEC Circuit Breakers
  • alt text
alt text
140M-C2T-B16

Motor Protection Circuit-Breaker

PrintPrint
打印
EmailEmail
共享
Product RegistrationProduct Registration
二维码
Allen-Bradley 140M-C2T-B16 product image
生命周期状态: 停止
ErrorsErrors
Rockwell Automation announces that as of February 25, 2022, the Motor Protection Circuit-Breaker will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期: February 25, 2022 替代类别: Engineering Replacement 替代产品: 140MT-D9T-B16 [https://www.rockwellautomation.com.cn/products/details.140MT-D9T-B16.html]
产品概览
可享更换服务
生命周期状态: 停止
ErrorsErrors
Rockwell Automation announces that as of February 25, 2022, the Motor Protection Circuit-Breaker will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期: February 25, 2022 替代类别: Engineering Replacement 替代产品: 140MT-D9T-B16 [https://www.rockwellautomation.com.cn/products/details.140MT-D9T-B16.html]
产品概览
可享更换服务
添加到BoM
  • 寻找支持
技术规格
基本信息
Electrical
Construction
Mechanical
Environmental
Certification
图纸
文档
替代产品
技术说明
Current Rating
1 - 1.6A,MxRtg MCPs(no OvPrt)is 1200.0A
With integrated auxiliary switch
No
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, AC
100 kA
Rated operation power at AC-3, 400 V
0.55 kw
Rated permanent current Iu
1.6 A
Rated operation power at AC-3, 230 V
0.25 kw
Rated operating voltage
230 A
Type of control element
Turn button
Overload release current setting
1 A
Type of electrical connection of main circuit
Screw connection
Magnetic release current per IEC
32 A
Rated operational current (Ie) per IEC
1.6 A
Magnetic trip current
33 A
Rated supply current (Ie)
0.1 A
Short circuit current (Icu) for group motor installation, max
65kA @ 480V
Current range
1 to 1.6 A
Ultimate short circuit breaking capacity (Icu) per IEC
8kA @ 690V
Rated service short circuit breaking capacity (Ics) per IEC
8kA @ 690V
Hp rating, max
1Hp @ 575V, 3-phase
Rated insulation voltage (Ui)
690V per IEC, SEV, VDE0660
Electrical life cycle
100000 ops (Ie maximum)
Switching of standard motors per IEC
1.1 kW @ 690V (AC-3), 3-phase
KW rating, max
1.1 kW @ 690V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC
No back-up fuse required @ 500V
Short circuit current (Type 2 coordination), max
50kA @ 480V
Total power loss (Pv) for circuit breaker
6...11.5 W @ rated load operating temperature
Rated thermal current (Ith)
0.1...32A @ 60°C ambient temperature
Short circuit current for tap conductor protection, max
65 kA @ 480Y/277V per UL 508-manual motor controller
Short circuit current for combination motor controller, max
65kA @ 480V/277V per UL 508-self-protected (Type E)
Fuse or circuit breaker per NEC, max
450 A, UL 508-manual motor controller
Rated impulse withstand voltage (Uimp)
Main circuits/overvoltage category: 6 kV/III
Short circuit current for group motor installation, max
65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect, max
65kA @ 480V, UL 508-manual motor controller
Magnetic release current
Fixed setting 16...21 x Ie max. Ie max. = maximum values of setting ranges (±20 %)
Number of poles
3
With thermal protection
Yes
Phase failure sensitive
Yes
Switch off technique
Thermomagnetic
Switching frequency, max
25 ops/h
Trip class
10
Rated frequency
50/60 Hz
Phase loss protection
Differential release
Width
45 mm
Depth
70 mm
Height
90 mm
Frame size
Frame size C, 32 A
Contactor size (Type 2 coordination), min
100-C16 @ 600V
Device construction
Built-in device fixed built-in technique
Degree of protection (IP)
IP2X
Weight
315 lb
Mechanical life operations
100000 /h
Breaking capacity
Standard breaking capacity
Shock
Transport (60068-2-27): 30 G, 11 ms, all axes
Protection type
Adjustable thermal/fixed magnetic (fixed at 16...20 x In)
Factory option
No circuit-breaker auxiliary or trip contacts
Vibration
Ops (60068-2-6): 5 G
Ambient storage temperature
-40 °C
Ambient operating temperature
-25 °C
Site altitude
2000 m (NN)
Moisture heat
40 °C, relative humidity 93 %, 56 d, (60068-2-3)
Dry heat
100 °C, relative humidity < 50 %, 7 d, (60086-2-2)
Dependence on temperature
No current reduction @ 60 °C
Moisture change climate
23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles, (600068-2-30)
Pollution degree
3
Ambient temperature compensation, max
-20 °C
Utilization category
Motor starter: AC-3 (IEC60947-4-1)
Overload protection characteristics
IEC 60947-4-1 motor protection
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
技术数据 出版
140m-td002_-en-p 140M-TD002
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
每页项目:
1-1 关于 1
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
技术规格
Current Rating
1 - 1.6A,MxRtg MCPs(no OvPrt)is 1200.0A
With integrated auxiliary switch
No
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, AC
100 kA
Rated operation power at AC-3, 400 V
0.55 kw
Rated permanent current Iu
1.6 A
Rated operation power at AC-3, 230 V
0.25 kw
Rated operating voltage
230 A
Type of control element
Turn button
Overload release current setting
1 A
Type of electrical connection of main circuit
Screw connection
Magnetic release current per IEC
32 A
Rated operational current (Ie) per IEC
1.6 A
Magnetic trip current
33 A
Rated supply current (Ie)
0.1 A
Short circuit current (Icu) for group motor installation, max
65kA @ 480V
Current range
1 to 1.6 A
Ultimate short circuit breaking capacity (Icu) per IEC
8kA @ 690V
Rated service short circuit breaking capacity (Ics) per IEC
8kA @ 690V
Hp rating, max
1Hp @ 575V, 3-phase
Rated insulation voltage (Ui)
690V per IEC, SEV, VDE0660
Electrical life cycle
100000 ops (Ie maximum)
Switching of standard motors per IEC
1.1 kW @ 690V (AC-3), 3-phase
KW rating, max
1.1 kW @ 690V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC
No back-up fuse required @ 500V
Short circuit current (Type 2 coordination), max
50kA @ 480V
Total power loss (Pv) for circuit breaker
6...11.5 W @ rated load operating temperature
Rated thermal current (Ith)
0.1...32A @ 60°C ambient temperature
Short circuit current for tap conductor protection, max
65 kA @ 480Y/277V per UL 508-manual motor controller
Short circuit current for combination motor controller, max
65kA @ 480V/277V per UL 508-self-protected (Type E)
Fuse or circuit breaker per NEC, max
450 A, UL 508-manual motor controller
Rated impulse withstand voltage (Uimp)
Main circuits/overvoltage category: 6 kV/III
Short circuit current for group motor installation, max
65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect, max
65kA @ 480V, UL 508-manual motor controller
Magnetic release current
Fixed setting 16...21 x Ie max. Ie max. = maximum values of setting ranges (±20 %)
Number of poles
3
With thermal protection
Yes
Phase failure sensitive
Yes
Switch off technique
Thermomagnetic
Switching frequency, max
25 ops/h
Trip class
10
Rated frequency
50/60 Hz
Phase loss protection
Differential release
Width
45 mm
Depth
70 mm
Height
90 mm
Frame size
Frame size C, 32 A
Contactor size (Type 2 coordination), min
100-C16 @ 600V
Device construction
Built-in device fixed built-in technique
Degree of protection (IP)
IP2X
Weight
315 lb
Mechanical life operations
100000 /h
Breaking capacity
Standard breaking capacity
Shock
Transport (60068-2-27): 30 G, 11 ms, all axes
Protection type
Adjustable thermal/fixed magnetic (fixed at 16...20 x In)
Factory option
No circuit-breaker auxiliary or trip contacts
Vibration
Ops (60068-2-6): 5 G
Ambient storage temperature
-40 °C
Ambient operating temperature
-25 °C
Site altitude
2000 m (NN)
Moisture heat
40 °C, relative humidity 93 %, 56 d, (60068-2-3)
Dry heat
100 °C, relative humidity < 50 %, 7 d, (60086-2-2)
Dependence on temperature
No current reduction @ 60 °C
Moisture change climate
23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles, (600068-2-30)
Pollution degree
3
Ambient temperature compensation, max
-20 °C
Utilization category
Motor starter: AC-3 (IEC60947-4-1)
Overload protection characteristics
IEC 60947-4-1 motor protection
图纸
登录您的罗克韦尔自动化帐户以查看和下载技术图纸.
登录
文档
140m-td002_-en-p 技术数据
140M-TD002
技术数据 出版
140m-td002_-en-p 140M-TD002
寻找更多文档?
在技术文档中心查找此产品的技术文档,或搜索我们的文献资料库。
搜索文献资料库
替代产品
每页项目:
1-1 关于 1
技术说明
技术说明
想要更多的技术说明?
在我们的知识库中查找罗克韦尔自动化技术专家关于该产品的问题和答案。
搜索知识库
寻找最近经销商
请联系您在{0}的经销商
更改位置
EmailEmail
PhonePhone
寻找合作伙伴
Motor Protection Circuit-Breaker
CloseClose
140M-C2T-B16
关闭
打印
Allen-Bradley 140M-C2T-B16 product image
电话:
呼叫
Rockwell Automation Home
Copyright ©2026 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页
  2. Chevron LeftChevron Left 产品
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose