Loading
Chevron UpChevron Up
Allen-Bradley 1408-BC3A-485 product image
Allen-Bradley 1408-BC3A-485 product image
Chevron DownChevron Down
Allen-Bradley 1408-BC3A-485 product image
Allen Bradley

PowerMonitor 1000, Consumption, RS-485

PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Catalog #: 1408-BC3A-485
Lifecycle status: Active
Allen-Bradley 1408-BC3A-485 product image
Allen-Bradley 1408-BC3A-485 product image
Allen-Bradley 1408-BC3A-485 product image
Allen Bradley
PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Lifecycle status: Active
Add to BoM
  • Get Support
Repair Options
CloseClose
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
Schedule a repair Request repair documentation Repair terms and conditions
Technical Specifications
Drawings
Documents
Accessories
Technotes
Vibration 2.0 G @ 10…500 Hz
Shock Operating : 30 G peak each axis
Dielectric withstand UL61010, EN61010, pollution degree 2
Storage temperature -40 to 85 °C
Operating temperature -10 to 60 °C
Humidity 5...95% noncondensing
Terminal blocks 0.34…2.5 mm² (22 AWG), 75 °C (167 °F) min copper wire only recommended torque 0.8 N.m (7 in-lb)
Control power 85…264V AC, 47…63 Hz 125…250V DC 4VA maximum
Current sense inputs: I1, I2, I3 Starting current : 5 mA
Voltage sense inputs: V1, V2, V3, max Input current : 2 mA
Voltage sense inputs: V1, V2, V3, min Input impedance : 5 MΩ
Control power and ground wiring terminals 120…240V AC, 50…60 Hz
Accuracy Power functions : kW, kVA, kVAR: EN62053-21:2003 accuracy requirement Class 1
Voltage sensing wiring terminals Direct connect up to 600V AC three-phase line-to-line, Maximum nominal line-to-ground voltage 347V, Use potential transformers (PTs) for higher voltages.
Ethernet network port - standard RJ45 jack with status indicators Ethernet network port hardware is included on all models. the port functions only on units ordered with or upgraded to the Ethernet network. the following protocols and functions are supported. Ethernet/IP Modbus TCP HTML webpage for configuration and data access lnk indicator solid green: IP link established OFF : no link established act indicator flashing yellow: data present on Ethernet port OFF : no data activity present
DIN rail clips Top and bottom clips for mounting unit on DIN rail
Configuration lock wiring terminals Wire together to help prevent configuration changes
LCD Unit configuration data display - not present on BC3 model
Mac ID label Aa:bb:cc:dd:ee:ff, used when assigning an IP address using DHCP, X, X, X
Current sensing wiring terminals Nominal input current 5 A, Use current transformers (CTs) to connect to power system
Serial port status indicators Tx indicator flashes yellow when data is being transmitted Rx indicator flashes yellow when data is being received
Status-input wiring terminals Restore factory defaults wiring terminals (BC3) Two internally-powered inputs (TS3, EM3), S2 can be used for demand period synchronization (TS3, EM3), FD1 and FD2 can be used to restore factory default configuration (BC3).
Serial port - three-pin RS-485 connector All models include RS-485 serial communication that supports the following protocols and functions. DF1 half-duplex slave, DF1 full-duplex, Modbus RTU slave, Configuration by using terminal emulation software, DH-485.
Module and network status indicators Module indicator GREEN: normal ops Alternating RED/GREEN: performing self-test RED (solid or blinking): initial power-up or failed self-test. network indicator GREEN: Ethernet connection established Blinking GREEN: Ethernet port looking for a connection RED: duplicate IP address detected.
Description PowerMonitor 1000 energy, demand, and PowerMonitor with serial network communication
Ampere meter True
Blind power meter True
Frequency meter True
Pulse counter True
Voltmeter True
Effective power measurement device True
Reactive power (kVAR) True
Real power (kW) True
Apparent power (kVA) True
True power factor True
Real power consumption (kWh) True
Reactive power consumption (kVARh) True
Apparent power consumption (kVAh) True
Time of use log True
Energy log True
Minimum/maximum log True
Unit status log True
Alarm log True
Digital output True
Digital accuracy Class1
Configurable via webpage True
CIP energy object True
Basic consumption meter w/ serial True
Sales Info
Repairable NOT_REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 14.9
Lead Time 71
Dimension Width 11.1
Dimension Length 20.399
Stock Status NON_STOCKED
Weight 0.576
Weight Unit KG
Dimension Unit CM
Drawings
Dimension Drawing (PDF) Download (PDF)
3D STP (STEP) Model Download (ZIP)
2D Drawing (PDF) Download (PDF)
Product Drawing Drawing (DXF)
Product Drawing Drawing (DXF)
Drawings
Dimension Drawing (PDF) Download (PDF)
3D STP (STEP) Model Download (ZIP)
2D Drawing (PDF) Download (PDF)
Product Drawing Drawing (DXF)
Product Drawing Drawing (DXF)
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
类型 资源 发布
General Product Profile --
General Product Cutsheet --
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Chevron RightChevron Right Search the Literature Library Chevron RightChevron Right
每页条目数:
1-1 的 1
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Technical Specifications
Vibration 2.0 G @ 10…500 Hz
Shock Operating : 30 G peak each axis
Dielectric withstand UL61010, EN61010, pollution degree 2
Storage temperature -40 to 85 °C
Operating temperature -10 to 60 °C
Humidity 5...95% noncondensing
Terminal blocks 0.34…2.5 mm² (22 AWG), 75 °C (167 °F) min copper wire only recommended torque 0.8 N.m (7 in-lb)
Control power 85…264V AC, 47…63 Hz 125…250V DC 4VA maximum
Current sense inputs: I1, I2, I3 Starting current : 5 mA
Voltage sense inputs: V1, V2, V3, max Input current : 2 mA
Voltage sense inputs: V1, V2, V3, min Input impedance : 5 MΩ
Control power and ground wiring terminals 120…240V AC, 50…60 Hz
Accuracy Power functions : kW, kVA, kVAR: EN62053-21:2003 accuracy requirement Class 1
Voltage sensing wiring terminals Direct connect up to 600V AC three-phase line-to-line, Maximum nominal line-to-ground voltage 347V, Use potential transformers (PTs) for higher voltages.
Ethernet network port - standard RJ45 jack with status indicators Ethernet network port hardware is included on all models. the port functions only on units ordered with or upgraded to the Ethernet network. the following protocols and functions are supported. Ethernet/IP Modbus TCP HTML webpage for configuration and data access lnk indicator solid green: IP link established OFF : no link established act indicator flashing yellow: data present on Ethernet port OFF : no data activity present
DIN rail clips Top and bottom clips for mounting unit on DIN rail
Configuration lock wiring terminals Wire together to help prevent configuration changes
LCD Unit configuration data display - not present on BC3 model
Mac ID label Aa:bb:cc:dd:ee:ff, used when assigning an IP address using DHCP, X, X, X
Current sensing wiring terminals Nominal input current 5 A, Use current transformers (CTs) to connect to power system
Serial port status indicators Tx indicator flashes yellow when data is being transmitted Rx indicator flashes yellow when data is being received
Status-input wiring terminals Restore factory defaults wiring terminals (BC3) Two internally-powered inputs (TS3, EM3), S2 can be used for demand period synchronization (TS3, EM3), FD1 and FD2 can be used to restore factory default configuration (BC3).
Serial port - three-pin RS-485 connector All models include RS-485 serial communication that supports the following protocols and functions. DF1 half-duplex slave, DF1 full-duplex, Modbus RTU slave, Configuration by using terminal emulation software, DH-485.
Module and network status indicators Module indicator GREEN: normal ops Alternating RED/GREEN: performing self-test RED (solid or blinking): initial power-up or failed self-test. network indicator GREEN: Ethernet connection established Blinking GREEN: Ethernet port looking for a connection RED: duplicate IP address detected.
Description PowerMonitor 1000 energy, demand, and PowerMonitor with serial network communication
Ampere meter True
Blind power meter True
Frequency meter True
Pulse counter True
Voltmeter True
Effective power measurement device True
Reactive power (kVAR) True
Real power (kW) True
Apparent power (kVA) True
True power factor True
Real power consumption (kWh) True
Reactive power consumption (kVARh) True
Apparent power consumption (kVAh) True
Time of use log True
Energy log True
Minimum/maximum log True
Unit status log True
Alarm log True
Digital output True
Digital accuracy Class1
Configurable via webpage True
CIP energy object True
Basic consumption meter w/ serial True
Sales Info
Repairable NOT_REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 14.9
Lead Time 71
Dimension Width 11.1
Dimension Length 20.399
Stock Status NON_STOCKED
Weight 0.576
Weight Unit KG
Dimension Unit CM
Drawings
Drawings
Dimension Drawing (PDF) Download (PDF)
3D STP (STEP) Model Download (ZIP)
2D Drawing (PDF) Download (PDF)
Product Drawing Drawing (DXF)
Product Drawing Drawing (DXF)
Drawings
Dimension Drawing (PDF) Download (PDF)
3D STP (STEP) Model Download (ZIP)
2D Drawing (PDF) Download (PDF)
Product Drawing Drawing (DXF)
Product Drawing Drawing (DXF)
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
文档
Product Profile General
--
Product Cutsheet General
--
类型 资源 发布
General Product Profile --
General Product Cutsheet --
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Chevron RightChevron Right Search the Literature Library Chevron RightChevron Right
Accessories
每页条目数:
1-1 的 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Loading
Find your nearest distributor
Change location
EmailEmail
PhonePhone
Find a partner Chevron RightChevron Right
PowerMonitor 1000, Consumption, RS-485
CloseClose
1408-BC3A-485
关闭
打印
Chevron LeftChevron Left
Allen-Bradley 1408-BC3A-485 product image
Chevron RightChevron Right
Chevron LeftChevron Left
Allen-Bradley 1408-BC3A-485 product image
Allen-Bradley 1408-BC3A-485 product image
Chevron RightChevron Right
手机:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页 Chevron RightChevron Right
  2. Chevron LeftChevron Left 产品 Chevron RightChevron Right
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策