生命周期状态:
活跃
Description
104-K 微型可逆接触器,螺丝式端子,9A,系统控制电压:440V 50Hz/480V 60Hz,3 个常开主触点,1 个常闭辅助触点
104-K09B02
IEC Miniature Reversing Contactor
Serial #:
此产品尚未验证,请{}确认真实性
注册您的产品
生命周期状态:
活跃
Description
104-K 微型可逆接触器,螺丝式端子,9A,系统控制电压:440V 50Hz/480V 60Hz,3 个常开主触点,1 个常闭辅助触点
概述
Electrical & Connectivity
General Features
Power & Electrical Characteristics
Compliance & Environment
Standards & Protection
Physical Characteristics
Mechanical
Construction
图纸
文档
配件
替代产品
技术说明
| 唯一产品序列号 |
104-K09B02
|
|---|---|
| 通用产品代码(UPC) |
662074499045
|
| 预计交期 |
29 天
|
| 标准保修期 |
1年 查看详情 |
| 原产国 |
瑞士
|
| Contact Rating |
9 A
|
|---|---|
| Sub Brand |
IEC
|
| Auxiliary contact configuration |
1 NC
|
|---|---|
| Coil consumption, hold-in |
5VA/1.8 W @ 50 Hz, 60 Hz, 50/60 Hz
|
| Coil consumption, pick-up |
35VA @ 50 Hz, 60 Hz, 50/60 Hz
|
| Coil insulation class |
Class F per IEC 60085, Class 105 insulation system per UL 508
|
| Coil operating limits, dropout |
(0.2...0.75) x Us @ 50 Hz, 60 Hz, 50/60 Hz
|
| Coil operating limits, pick-up |
(0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz
|
| Coil operating time |
15...40 ms, closing delay @ AC
|
| Conductor cross section per UL/CSA |
18
|
| Contacts |
3 power poles with internal NC auxiliary contact
|
| Current (Ie), max |
12 A
|
| Current rating |
5 A
|
| DIN fuses (gG, gL) current rating |
Type 2 (per IEC 60947-4-1): 20A @ 400V, 50 kA available fault current
|
| Function |
Reversing contactor
|
| Function or layout |
Nothing specified
|
| General purpose current (enclosed) |
15 A per UL/CSA
|
| Main current circuit resistance |
2.2 mohm
|
| Power dissipation by all circuits at Ie AC-3/400V |
0.9 W
|
| Rated coil frequency |
AC 50/60 Hz, DC
|
| Rated control supply voltage at AC 50 Hz |
440 V
|
| Rated control supply voltage at AC 60 Hz |
480 V
|
| Rated control supply voltage at DC |
0 V
|
| Rated current (enclosed) |
9.8A @ 115V, 1-phase per UL/CSA
|
| Rated filament current |
9A @ 230/240V, AC-5b
|
| Rated impulse withstand voltage (Uimp) |
6 kV
|
| Rated isolation voltage (Ui) |
690V per IEC
|
| Rated operational current (Ie) |
8.9A @ 690V, Star-Delta starting (50 Hz)
|
| Rated operational power (Pe) |
8.3 kW @ 240V, AC-1 (50 Hz), ambient temperature 40 °C
|
| Rated power (enclosed) |
5Hp @ 575V, 3-phase per UL/CSA
|
| Rated voltage (Ue) |
690V @ AC, 50/60 Hz
|
| Rating for switching AC motors |
3-poles: 4 kW @ 690V (AC-2, AC-3, AC-4), 3-phase (50 Hz)
|
| Short time withstand (Icw) |
96A @ 10s, 60 °C
|
| Switching frequency, max |
250 ops/h, AC-4 (approximately 200000 ops)
|
| Switching of DC loads |
3-poles in series: 9A @ 48/60V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C)
|
| Switching of hermetically sealed cooling compressor motors |
18A @ 400V, AC-8a (manual reset of overload release (50 Hz))
|
| Switching of lamps |
Gas discharge lA, open: 18A @ 40°C, AC-5a
|
| Switching of low inductive loads in home appliances |
20A @ 400V, AC-7a per IEC 61095 (50 Hz)
|
| Switching of motor load for home appliances |
11A @ 400V, AC-7b (50 Hz)
|
| Switching of power transformers |
Apparent power: 4 kVA @ 690V, AC-6a @ 50Hz (n = 30)
|
| Terminal type |
Screw terminals
|
| Total power dissipation |
DC control: 3.5 W @ 400V, AC-3, Ie
|
| UL class CC and CSA HRCI-MISC fuses rating |
30A @ 600V, 50 kA available fault current per UL 508 and CSA 22.2 No. 14
|
| UL class J and CSA HRCI-J fuses rating |
30A @ 600V, 50 kA available fault current per UL 508 and CSA 22.2 No. 14
|
| UL class K5 and RK5 fuses rating |
40A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
|
| Voltage type for actuating |
AC
|
| Altitude of installation site, max |
2000 m (NN), per IEC 60947-4
|
|---|---|
| Ambient temperature |
Storage: -55...80 (-67...176)
|
| Auxiliary contacts |
IP2X
|
| Degree of protection (IP) |
IP2X
|
Mechanical
| Conductor cross section |
0.75...2.5 mm², 2 conductors @ main contact
|
|---|---|
| Lifespan |
Mechanical DC control: 15000000 ops
|
| Recommended torque |
10.6 in-lb
|
| Shock resistance |
IEC 60068-2
|
| Type of electrical connection of main circuit |
Screw connection
|
| Vibration resistance |
IEC 60068-2
|
Construction
| Features |
Mini-contactors, Uniform panel mounting dimensions, Panel mounting or mounting on 35 mm DIN Rail, Made of environmentally friendly materials
|
|---|---|
| Optional accessories |
Front-mount auxiliary contacts, surge suppressors, electronic timers, mechanical interlocks
|
| Optional overload relays |
Bimetallic
|
| 基本信息 | 出版 |
|---|---|
| Product Cutsheet | -- |
| 技术数据 | 出版 |
|---|---|
| 100-td013_-en-p | 100-TD013 |
每页项目:
每页项目:
| 技术说明 |
|---|
概述
| 唯一产品序列号 |
104-K09B02
|
|---|---|
| 通用产品代码(UPC) |
662074499045
|
| 预计交期 |
29 天
|
| 标准保修期 |
1年 查看详情 |
| 原产国 |
瑞士
|
Electrical & Connectivity
| Contact Rating |
9 A
|
|---|---|
| Sub Brand |
IEC
|
| Auxiliary contact configuration |
1 NC
|
|---|---|
| Coil consumption, hold-in |
5VA/1.8 W @ 50 Hz, 60 Hz, 50/60 Hz
|
| Coil consumption, pick-up |
35VA @ 50 Hz, 60 Hz, 50/60 Hz
|
| Coil insulation class |
Class F per IEC 60085, Class 105 insulation system per UL 508
|
| Coil operating limits, dropout |
(0.2...0.75) x Us @ 50 Hz, 60 Hz, 50/60 Hz
|
| Coil operating limits, pick-up |
(0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz
|
| Coil operating time |
15...40 ms, closing delay @ AC
|
| Conductor cross section per UL/CSA |
18
|
| Contacts |
3 power poles with internal NC auxiliary contact
|
| Current (Ie), max |
12 A
|
| Current rating |
5 A
|
| DIN fuses (gG, gL) current rating |
Type 2 (per IEC 60947-4-1): 20A @ 400V, 50 kA available fault current
|
| Function |
Reversing contactor
|
| Function or layout |
Nothing specified
|
| General purpose current (enclosed) |
15 A per UL/CSA
|
| Main current circuit resistance |
2.2 mohm
|
| Power dissipation by all circuits at Ie AC-3/400V |
0.9 W
|
| Rated coil frequency |
AC 50/60 Hz, DC
|
| Rated control supply voltage at AC 50 Hz |
440 V
|
| Rated control supply voltage at AC 60 Hz |
480 V
|
| Rated control supply voltage at DC |
0 V
|
| Rated current (enclosed) |
9.8A @ 115V, 1-phase per UL/CSA
|
| Rated filament current |
9A @ 230/240V, AC-5b
|
| Rated impulse withstand voltage (Uimp) |
6 kV
|
| Rated isolation voltage (Ui) |
690V per IEC
|
| Rated operational current (Ie) |
8.9A @ 690V, Star-Delta starting (50 Hz)
|
| Rated operational power (Pe) |
8.3 kW @ 240V, AC-1 (50 Hz), ambient temperature 40 °C
|
| Rated power (enclosed) |
5Hp @ 575V, 3-phase per UL/CSA
|
| Rated voltage (Ue) |
690V @ AC, 50/60 Hz
|
| Rating for switching AC motors |
3-poles: 4 kW @ 690V (AC-2, AC-3, AC-4), 3-phase (50 Hz)
|
| Short time withstand (Icw) |
96A @ 10s, 60 °C
|
| Switching frequency, max |
250 ops/h, AC-4 (approximately 200000 ops)
|
| Switching of DC loads |
3-poles in series: 9A @ 48/60V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C)
|
| Switching of hermetically sealed cooling compressor motors |
18A @ 400V, AC-8a (manual reset of overload release (50 Hz))
|
| Switching of lamps |
Gas discharge lA, open: 18A @ 40°C, AC-5a
|
| Switching of low inductive loads in home appliances |
20A @ 400V, AC-7a per IEC 61095 (50 Hz)
|
| Switching of motor load for home appliances |
11A @ 400V, AC-7b (50 Hz)
|
| Switching of power transformers |
Apparent power: 4 kVA @ 690V, AC-6a @ 50Hz (n = 30)
|
| Terminal type |
Screw terminals
|
| Total power dissipation |
DC control: 3.5 W @ 400V, AC-3, Ie
|
| UL class CC and CSA HRCI-MISC fuses rating |
30A @ 600V, 50 kA available fault current per UL 508 and CSA 22.2 No. 14
|
| UL class J and CSA HRCI-J fuses rating |
30A @ 600V, 50 kA available fault current per UL 508 and CSA 22.2 No. 14
|
| UL class K5 and RK5 fuses rating |
40A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
|
| Voltage type for actuating |
AC
|
Compliance & Environment
| Altitude of installation site, max |
2000 m (NN), per IEC 60947-4
|
|---|---|
| Ambient temperature |
Storage: -55...80 (-67...176)
|
| Auxiliary contacts |
IP2X
|
| Degree of protection (IP) |
IP2X
|
Physical Characteristics
Mechanical
| Conductor cross section |
0.75...2.5 mm², 2 conductors @ main contact
|
|---|---|
| Lifespan |
Mechanical DC control: 15000000 ops
|
| Recommended torque |
10.6 in-lb
|
| Shock resistance |
IEC 60068-2
|
| Type of electrical connection of main circuit |
Screw connection
|
| Vibration resistance |
IEC 60068-2
|
Construction
| Features |
Mini-contactors, Uniform panel mounting dimensions, Panel mounting or mounting on 35 mm DIN Rail, Made of environmentally friendly materials
|
|---|---|
| Optional accessories |
Front-mount auxiliary contacts, surge suppressors, electronic timers, mechanical interlocks
|
| Optional overload relays |
Bimetallic
|
图纸
文档
|
Product Cutsheet
基本信息
-- |
|
100-td013_-en-p
技术数据
100-TD013 |
| 基本信息 | 出版 |
|---|---|
| Product Cutsheet | -- |
| 技术数据 | 出版 |
| 100-td013_-en-p | 100-TD013 |
配件
每页项目:
替代产品
每页项目:
技术说明
| 技术说明 |
|---|
基于制造地点的多个原产国
IEC Miniature Reversing Contactor
104-K09B02
关闭
打印
Copyright ©2026 Rockwell Automation, Inc.