Loading
Allen-Bradley 104-C60D22 product image
Allen Bradley

IEC 60 A Reversing Contactor

PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Catalog #: 104-C60D22
Lifecycle status: Active
Allen-Bradley 104-C60D22 product image
Allen Bradley
PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Lifecycle status: Active
Add to BoM
  • Get Support
Repair Options
CloseClose
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
Schedule a repair Request repair documentation Repair terms and conditions
Technical Specifications
Drawings
Documents
Certifications
Accessories
Technotes
Coil Code 110V 50 Hz / 120V 60 Hz.
Maximum Ampere Rating 60 A
Product Family IEC
Voltage type for actuating AC
Rated control supply voltage at AC 50 Hz 110 V
Rated control supply voltage at AC 60 Hz 120 V
Current (Ie), max 97 A
Switching frequency, max 120 ops/h
Main current circuit resistance 0.9 mohm
Cross section per UL/CSA 16
Rated operational current for contactor at elevator duty (UL/CSA) 42.0A @ 230V
Rated operational power for contactor at elevator duty (UL/CSA) 40Hp @ 575V
Rated isolation voltage (Ui) 690V @ IEC
Rated voltage (Ue) 690V @ AC, 50/60 Hz
Rated operational power for contactor at wye-delta 75Hp @ 575V, 60 Hz
Rated filament current 60A @ 230/240V, AC-5b
Power dissipation 9.7 W @ 400V, AC-3, Ie
Coil terminal conductor cross section 1…4 mm² @ 2 conductor
Rated current (enclosed) 56A @ 115V, 1-phase per UL/CSA
Rated power (enclosed) 50Hp @ 575V, 3-phase per UL/CSA
General purpose current (enclosed) 90 A per UL/CSA
Capacitance, max 800 µF @ short-circuit current of 50 kA
Operating limits, pick-up (0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Short time withstand (Icw) 700A @ 10s, 60 °C
Coil consumption, hold-in 4 W @ DC (conventional)
Coil consumption, pick-up 235VA @ 50 Hz, 60 Hz, 50/60 Hz
Operating time 20…40 ms @ DC (conventional) opening delay
Total power dissipation DC control (conventional): 13.7 W @ 400V, AC-3, Ie
Operating limits, dropout (0.3...0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Switching of lamps Gas discharge lA, open: 81A @ 40°C (104 °F), AC-5a
Switching of hermetically sealed cooling compressor motors 72A @ 500V, AC-8a (manual reset of overload release (50 Hz))
Coil insulation class Class F per IEC 60085, UL Class 105
Rating for switching AC motors 3-poles: 50Hp @ 575V (AC-2, AC-3, AC-4), 3-phase (60 Hz)
BS88 fuses current rating Type 2 (per IEC 60947-4-1): 100A @ 415V, 65 kA available fault current
UL class K5 and RK5 fuses rating 200A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
UL inverse-time circuit breaker 250A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
Rated operational current (Ie) 95A @ 500V, Star-Delta starting (50 Hz)
Rated operational power (Pe) 87 kW @ 500V, AC-1 active power load (50 Hz), ambient temperature 60 °C
DIN fuses (gG, gL) current rating Type 2 (per IEC 60947-4-1): 160A @ 690V, 50 kA available fault current
UL class J and CSA HRCI-J fuses rating 80A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14
Switching of power transformers Apparent power: 93.7 kVA @ 660V, AC-6a 60 Hz (n = 30)
Switching of 3-phase Capacitors Single capacitor: 50 kVAR @ 690V, AC-6b 50 Hz, 40 °C (Inductance of leads between capacitors in parallel: min. 6 µH)
Switching of DC loads 3-Poles in series: 90A @ 48/60V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C)
Contacts 3 power poles with internal NO or NC auxiliary contact or 4 power poles (9...23 A), Optional front-or side mounted 1-2 or 4-pole external auxiliary contact block
Function Reversing contactor
Rated impulse voltage withstand (Uimp) 6 kV
Conventional coil type True
Rated coil frequency AC 50/60 Hz, DC
Recommended torque 9 in-lb
Vibration resistance IEC 60068-2-6
Shock resistance IEC 60068-2-27
Coil termination Line side connection
Conductor cross section Main contacts, 2 conductor: 2.5…35 mm²
Lifespan Mechanical DC control: 6000000 ops
Weight 3.22 kg (7.1 lbs) reverse @ DC
Type of electrical connection of main circuit Screw connection
Options Empty
Optional overload relays Electronic or bimetallic
Optional accessories Front or side-mount auxiliary contacts, Surge suppressors, Electronic or pneumatic timers, Mechanical interlocks, Mechanical latches
Features Panel mounting or mounting on 35 mm DIN rail, AC or DC coil control, Reversible coil terminals (line or load side), Common accessories, Made of environmentally friendly materials
Auxiliary contacts 1 NO, 1 NC
Altitude of installation site, max 2000 m (NN), per IEC60947-1
Protection against accidental contact Finger-and back-of-hand proof per VDE0106, part 100
Ambient temperature Storage: -55...80 (-67...176)
Protection class auxiliary contact IP2X
Sales Info
Repairable NOT_REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 20.904
Lead Time 21
Dimension Width 18.009
Dimension Length 30.099
Stock Status NON_STOCKED
Weight 3.393
Weight Unit KG
Dimension Unit CM
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
类型 资源 发布
General Product Cutsheet --
Technical Data 100-td013_-en-p 100-TD013
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library Chevron RightChevron Right
China CCC
  • China CCC
  • SUVA LVD Type Approval

This product was certified with the above certifications as of 2025-07-20. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

每页条目数:
1-1 的 1
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Technical Specifications
Coil Code 110V 50 Hz / 120V 60 Hz.
Maximum Ampere Rating 60 A
Product Family IEC
Voltage type for actuating AC
Rated control supply voltage at AC 50 Hz 110 V
Rated control supply voltage at AC 60 Hz 120 V
Current (Ie), max 97 A
Switching frequency, max 120 ops/h
Main current circuit resistance 0.9 mohm
Cross section per UL/CSA 16
Rated operational current for contactor at elevator duty (UL/CSA) 42.0A @ 230V
Rated operational power for contactor at elevator duty (UL/CSA) 40Hp @ 575V
Rated isolation voltage (Ui) 690V @ IEC
Rated voltage (Ue) 690V @ AC, 50/60 Hz
Rated operational power for contactor at wye-delta 75Hp @ 575V, 60 Hz
Rated filament current 60A @ 230/240V, AC-5b
Power dissipation 9.7 W @ 400V, AC-3, Ie
Coil terminal conductor cross section 1…4 mm² @ 2 conductor
Rated current (enclosed) 56A @ 115V, 1-phase per UL/CSA
Rated power (enclosed) 50Hp @ 575V, 3-phase per UL/CSA
General purpose current (enclosed) 90 A per UL/CSA
Capacitance, max 800 µF @ short-circuit current of 50 kA
Operating limits, pick-up (0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Short time withstand (Icw) 700A @ 10s, 60 °C
Coil consumption, hold-in 4 W @ DC (conventional)
Coil consumption, pick-up 235VA @ 50 Hz, 60 Hz, 50/60 Hz
Operating time 20…40 ms @ DC (conventional) opening delay
Total power dissipation DC control (conventional): 13.7 W @ 400V, AC-3, Ie
Operating limits, dropout (0.3...0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Switching of lamps Gas discharge lA, open: 81A @ 40°C (104 °F), AC-5a
Switching of hermetically sealed cooling compressor motors 72A @ 500V, AC-8a (manual reset of overload release (50 Hz))
Coil insulation class Class F per IEC 60085, UL Class 105
Rating for switching AC motors 3-poles: 50Hp @ 575V (AC-2, AC-3, AC-4), 3-phase (60 Hz)
BS88 fuses current rating Type 2 (per IEC 60947-4-1): 100A @ 415V, 65 kA available fault current
UL class K5 and RK5 fuses rating 200A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
UL inverse-time circuit breaker 250A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
Rated operational current (Ie) 95A @ 500V, Star-Delta starting (50 Hz)
Rated operational power (Pe) 87 kW @ 500V, AC-1 active power load (50 Hz), ambient temperature 60 °C
DIN fuses (gG, gL) current rating Type 2 (per IEC 60947-4-1): 160A @ 690V, 50 kA available fault current
UL class J and CSA HRCI-J fuses rating 80A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14
Switching of power transformers Apparent power: 93.7 kVA @ 660V, AC-6a 60 Hz (n = 30)
Switching of 3-phase Capacitors Single capacitor: 50 kVAR @ 690V, AC-6b 50 Hz, 40 °C (Inductance of leads between capacitors in parallel: min. 6 µH)
Switching of DC loads 3-Poles in series: 90A @ 48/60V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C)
Contacts 3 power poles with internal NO or NC auxiliary contact or 4 power poles (9...23 A), Optional front-or side mounted 1-2 or 4-pole external auxiliary contact block
Function Reversing contactor
Rated impulse voltage withstand (Uimp) 6 kV
Conventional coil type True
Rated coil frequency AC 50/60 Hz, DC
Recommended torque 9 in-lb
Vibration resistance IEC 60068-2-6
Shock resistance IEC 60068-2-27
Coil termination Line side connection
Conductor cross section Main contacts, 2 conductor: 2.5…35 mm²
Lifespan Mechanical DC control: 6000000 ops
Weight 3.22 kg (7.1 lbs) reverse @ DC
Type of electrical connection of main circuit Screw connection
Options Empty
Optional overload relays Electronic or bimetallic
Optional accessories Front or side-mount auxiliary contacts, Surge suppressors, Electronic or pneumatic timers, Mechanical interlocks, Mechanical latches
Features Panel mounting or mounting on 35 mm DIN rail, AC or DC coil control, Reversible coil terminals (line or load side), Common accessories, Made of environmentally friendly materials
Auxiliary contacts 1 NO, 1 NC
Altitude of installation site, max 2000 m (NN), per IEC60947-1
Protection against accidental contact Finger-and back-of-hand proof per VDE0106, part 100
Ambient temperature Storage: -55...80 (-67...176)
Protection class auxiliary contact IP2X
Sales Info
Repairable NOT_REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 20.904
Lead Time 21
Dimension Width 18.009
Dimension Length 30.099
Stock Status NON_STOCKED
Weight 3.393
Weight Unit KG
Dimension Unit CM
Drawings
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Sign in to your Rockwell Automation account to view and download technical drawings.
登录
文档
Product Cutsheet General
--
100-td013_-en-p Technical Data
100-TD013
类型 资源 发布
General Product Cutsheet --
Technical Data 100-td013_-en-p 100-TD013
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library Chevron RightChevron Right
认证
China CCC
  • China CCC
  • SUVA LVD Type Approval

This product was certified with the above certifications as of 2025-07-20. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Accessories
每页条目数:
1-1 的 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Loading
Find your nearest distributor
Change location
EmailEmail
PhonePhone
Find a partner Chevron RightChevron Right
IEC 60 A Reversing Contactor
CloseClose
104-C60D22
关闭
打印
Allen-Bradley 104-C60D22 product image
手机:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页 Chevron RightChevron Right
  2. Chevron LeftChevron Left 产品 Chevron RightChevron Right
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose