Coil Code 200-220V 50 Hz / 208-240V 60 H
Maximum Ampere Rating 9 A
Product Family IEC
Voltage type for actuating AC
Rated control supply voltage at AC 50 Hz 200 V
Rated control supply voltage at AC 60 Hz 208 V
Current (Ie), max 97 A
Switching frequency, max 250 ops/h
Main current circuit resistance 2.7 mohm
Cross section per UL/CSA 16
Rated operational current for contactor at elevator duty (UL/CSA) 7.8A @ 200V
Rated operational power for contactor at elevator duty (UL/CSA) 5Hp @ 575V
Rated isolation voltage (Ui) 690V @ IEC
Rated voltage (Ue) 690V @ AC, 50/60 Hz
Rated operational power for contactor at wye-delta 5Hp @ 230V, 60 Hz
Rated filament current 12A @ 230/240V, AC-5b
Power dissipation 0.66 W @ 400V, AC-3, Ie
Coil terminal conductor cross section 1…4 mm² @ 2 conductor
Rated current (enclosed) 9.8A @ 115V, 1-phase per UL/CSA
Rated power (enclosed) 7.5Hp @ 575V, 3-phase per UL/CSA
Coil consumption pick-up (avg/peak) 14/22 W @ DC (electronic-EA)
General purpose current (enclosed) 25 A per UL/CSA
Capacitance, max 500 µF @ short-circuit current of 20 kA
Switching of low inductive loads 32A @ 440V, AC-7a per IEC 61095 (50 Hz)
Operating limits, pick-up (0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Switching of motor load 9A @ 400V, AC-7b per IEC 61095 (50 Hz)
Short time withstand (Icw) 170A @ 10s, 60 °C
Coil consumption, hold-in 9.5VA/2.7 W @ 50 Hz, 60 Hz, 50/60 Hz
Coil consumption, pick-up 75VA @ 50 Hz, 60 Hz, 50/60 Hz
Operating time 15…30 ms @ AC closing delay
Total power dissipation DC control (electronic): 2.4 W @ 400V, AC-3, Ie
Operating limits, dropout (0.3...0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Switching of lamps Gas discharge lA, open: 22.5A @ 40°C (104 °F), AC-5a
Switching of hermetically sealed cooling compressor motors 8A @ 690V, AC-8a (manual reset of overload release (50 Hz))
Coil insulation class Class F per IEC 60085, UL Class 105
Rating for switching AC motors 3-poles: 7.5Hp @ 575V (AC-2, AC-3, AC-4), 3-phase (60 Hz)
BS88 fuses current rating Type 2 (per IEC 60947-4-1): 20A @ 415V, 65 kA available fault current
UL class K5 and RK5 fuses rating 35A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
UL class CC and CSA HRCI-MISC fuses rating 20A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14
UL inverse-time circuit breaker 30 A @ 600Y/347V @ 25kA available fault current per UL 508 and CSA 22.2 No. 14
Rated operational current (Ie) 9A @ 575V, 3-phase per UL/CSA
Rated operational power (Pe) 7.5 kW @ 690V, Star-Delta starting (50 Hz)
DIN fuses (gG, gL) current rating Type 2 (per IEC 60947-4-1): 25A @ 690V, 50 kA available fault current
UL class J and CSA HRCI-J fuses rating 20A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14
Switching of power transformers Apparent power: 9.4 kVA @ 500V, AC-6a 50 Hz (n = 30)
Switching of 3-phase Capacitors Single capacitor: 8 kVAR @ 690V, AC-6b 50 Hz, 60 °C (Inductance of leads between capacitors in parallel: min. 6 µH)
Switching of DC loads 3-Poles in series: 6A @ 220V (Shunt-wound motors starting, reverse current braking, reversing, stepping DC-3 at 60 °C)
Contacts 3 power poles with internal NO or NC auxiliary contact or 4 power poles (9...23 A), Optional front-or side mounted 1-2 or 4-pole external auxiliary contact block
Function Reversing contactor
Rated impulse voltage withstand (Uimp) 6 kV
Conventional coil type True
Electronic-EI coil type True
Rated coil frequency AC 50/60 Hz, DC
Width 98.6 mm
Height 80.77 mm
Depth 84.63 mm
Options Empty
Optional overload relays Electronic or bimetallic
Optional accessories Front or side-mount auxiliary contacts, Surge suppressors, Electronic or pneumatic timers, Mechanical interlocks, Mechanical latches
Features Panel mounting or mounting on 35 mm DIN rail, AC or DC coil control, Reversible coil terminals (line or load side), Common accessories, Made of environmentally friendly materials
Recommended torque 9 in-lb
Vibration resistance IEC 60068-2-6
Shock resistance IEC 60068-2-27
Coil termination Line side connection
Conductor cross section Main contacts, 2 conductor: 1…4 mm²
Lifespan Mechanical DC control: 13000000 ops
Weight 1.27 kg (2.81 lbs) reverse @ DC
Type of electrical connection of main circuit Screw connection
Auxiliary contacts 1 NO, 1 NC
Altitude of installation site, max 2000 m (NN), per IEC60947-1
Protection against accidental contact Finger-and back-of-hand proof per VDE0106, part 100
Ambient temperature Storage: -55...80 (-67...176)
Protection class auxiliary contact IP2X
Sales Info
Repairable NOT_REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 10.795
Lead Time 21
Dimension Width 10.389
Dimension Length 2.489
Stock Status NON_STOCKED
Weight 0.108
Weight Unit KG
Dimension Unit CM
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
类型 资源 发布
General Product Cutsheet --
Technical Data 100-td013_-en-p 100-TD013
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library Chevron RightChevron Right
IECEE Scheme
  • IECEE Scheme
  • SUVA LVD Type Approval

This product was certified with the above certifications as of 2025-07-20. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

每页条目数:
1-1 的 1
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Technical Specifications
Coil Code 200-220V 50 Hz / 208-240V 60 H
Maximum Ampere Rating 9 A
Product Family IEC
Voltage type for actuating AC
Rated control supply voltage at AC 50 Hz 200 V
Rated control supply voltage at AC 60 Hz 208 V
Current (Ie), max 97 A
Switching frequency, max 250 ops/h
Main current circuit resistance 2.7 mohm
Cross section per UL/CSA 16
Rated operational current for contactor at elevator duty (UL/CSA) 7.8A @ 200V
Rated operational power for contactor at elevator duty (UL/CSA) 5Hp @ 575V
Rated isolation voltage (Ui) 690V @ IEC
Rated voltage (Ue) 690V @ AC, 50/60 Hz
Rated operational power for contactor at wye-delta 5Hp @ 230V, 60 Hz
Rated filament current 12A @ 230/240V, AC-5b
Power dissipation 0.66 W @ 400V, AC-3, Ie
Coil terminal conductor cross section 1…4 mm² @ 2 conductor
Rated current (enclosed) 9.8A @ 115V, 1-phase per UL/CSA
Rated power (enclosed) 7.5Hp @ 575V, 3-phase per UL/CSA
Coil consumption pick-up (avg/peak) 14/22 W @ DC (electronic-EA)
General purpose current (enclosed) 25 A per UL/CSA
Capacitance, max 500 µF @ short-circuit current of 20 kA
Switching of low inductive loads 32A @ 440V, AC-7a per IEC 61095 (50 Hz)
Operating limits, pick-up (0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Switching of motor load 9A @ 400V, AC-7b per IEC 61095 (50 Hz)
Short time withstand (Icw) 170A @ 10s, 60 °C
Coil consumption, hold-in 9.5VA/2.7 W @ 50 Hz, 60 Hz, 50/60 Hz
Coil consumption, pick-up 75VA @ 50 Hz, 60 Hz, 50/60 Hz
Operating time 15…30 ms @ AC closing delay
Total power dissipation DC control (electronic): 2.4 W @ 400V, AC-3, Ie
Operating limits, dropout (0.3...0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Switching of lamps Gas discharge lA, open: 22.5A @ 40°C (104 °F), AC-5a
Switching of hermetically sealed cooling compressor motors 8A @ 690V, AC-8a (manual reset of overload release (50 Hz))
Coil insulation class Class F per IEC 60085, UL Class 105
Rating for switching AC motors 3-poles: 7.5Hp @ 575V (AC-2, AC-3, AC-4), 3-phase (60 Hz)
BS88 fuses current rating Type 2 (per IEC 60947-4-1): 20A @ 415V, 65 kA available fault current
UL class K5 and RK5 fuses rating 35A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
UL class CC and CSA HRCI-MISC fuses rating 20A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14
UL inverse-time circuit breaker 30 A @ 600Y/347V @ 25kA available fault current per UL 508 and CSA 22.2 No. 14
Rated operational current (Ie) 9A @ 575V, 3-phase per UL/CSA
Rated operational power (Pe) 7.5 kW @ 690V, Star-Delta starting (50 Hz)
DIN fuses (gG, gL) current rating Type 2 (per IEC 60947-4-1): 25A @ 690V, 50 kA available fault current
UL class J and CSA HRCI-J fuses rating 20A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14
Switching of power transformers Apparent power: 9.4 kVA @ 500V, AC-6a 50 Hz (n = 30)
Switching of 3-phase Capacitors Single capacitor: 8 kVAR @ 690V, AC-6b 50 Hz, 60 °C (Inductance of leads between capacitors in parallel: min. 6 µH)
Switching of DC loads 3-Poles in series: 6A @ 220V (Shunt-wound motors starting, reverse current braking, reversing, stepping DC-3 at 60 °C)
Contacts 3 power poles with internal NO or NC auxiliary contact or 4 power poles (9...23 A), Optional front-or side mounted 1-2 or 4-pole external auxiliary contact block
Function Reversing contactor
Rated impulse voltage withstand (Uimp) 6 kV
Conventional coil type True
Electronic-EI coil type True
Rated coil frequency AC 50/60 Hz, DC
Width 98.6 mm
Height 80.77 mm
Depth 84.63 mm
Options Empty
Optional overload relays Electronic or bimetallic
Optional accessories Front or side-mount auxiliary contacts, Surge suppressors, Electronic or pneumatic timers, Mechanical interlocks, Mechanical latches
Features Panel mounting or mounting on 35 mm DIN rail, AC or DC coil control, Reversible coil terminals (line or load side), Common accessories, Made of environmentally friendly materials
Recommended torque 9 in-lb
Vibration resistance IEC 60068-2-6
Shock resistance IEC 60068-2-27
Coil termination Line side connection
Conductor cross section Main contacts, 2 conductor: 1…4 mm²
Lifespan Mechanical DC control: 13000000 ops
Weight 1.27 kg (2.81 lbs) reverse @ DC
Type of electrical connection of main circuit Screw connection
Auxiliary contacts 1 NO, 1 NC
Altitude of installation site, max 2000 m (NN), per IEC60947-1
Protection against accidental contact Finger-and back-of-hand proof per VDE0106, part 100
Ambient temperature Storage: -55...80 (-67...176)
Protection class auxiliary contact IP2X
Sales Info
Repairable NOT_REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 10.795
Lead Time 21
Dimension Width 10.389
Dimension Length 2.489
Stock Status NON_STOCKED
Weight 0.108
Weight Unit KG
Dimension Unit CM
Drawings
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
文档
Product Cutsheet General
--
100-td013_-en-p Technical Data
100-TD013
类型 资源 发布
General Product Cutsheet --
Technical Data 100-td013_-en-p 100-TD013
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library Chevron RightChevron Right
认证
IECEE Scheme
  • IECEE Scheme
  • SUVA LVD Type Approval

This product was certified with the above certifications as of 2025-07-20. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Accessories
每页条目数:
1-1 的 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Loading
Find your nearest distributor
Change location
EmailEmail
PhonePhone
Find a partner Chevron RightChevron Right
IEC 9 A Reversing Contactor
CloseClose
104-C09L22
关闭
打印
Allen-Bradley 104-C09L22 product image
手机:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页 Chevron RightChevron Right
  2. Chevron LeftChevron Left 产品 Chevron RightChevron Right
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose