| Coil Code |
200-220V 50 Hz / 208-240V 60 H
|
|---|---|
| Maximum Ampere Rating |
9 A
|
| Sub Brand |
IEC
|
| Voltage type for actuating |
AC
|
|---|---|
| Rated control supply voltage at AC 50 Hz |
200 V
|
| Rated control supply voltage at AC 60 Hz |
208 V
|
| Current (Ie), max |
97 A
|
| Switching frequency, max |
250 ops/h
|
| Main current circuit resistance |
2.7 mohm
|
| Cross section per UL/CSA |
16
|
| Rated operational current for contactor at elevator duty (UL/CSA) |
7.8A @ 200V
|
| Rated operational power for contactor at elevator duty (UL/CSA) |
5Hp @ 575V
|
| Rated isolation voltage (Ui) |
690V @ IEC
|
| Rated voltage (Ue) |
690V @ AC, 50/60 Hz
|
| Rated operational power for contactor at wye-delta |
5Hp @ 230V, 60 Hz
|
| Rated filament current |
12A @ 230/240V, AC-5b
|
| Power dissipation |
0.66 W @ 400V, AC-3, Ie
|
| Coil terminal conductor cross section |
1…4 mm² @ 2 conductor
|
| Rated current (enclosed) |
9.8A @ 115V, 1-phase per UL/CSA
|
| Rated power (enclosed) |
7.5Hp @ 575V, 3-phase per UL/CSA
|
| Coil consumption pick-up (avg/peak) |
14/22 W @ DC (electronic-EA)
|
| General purpose current (enclosed) |
25 A per UL/CSA
|
| Capacitance, max |
500 µF @ short-circuit current of 20 kA
|
| Switching of low inductive loads |
32A @ 440V, AC-7a per IEC 61095 (50 Hz)
|
| Operating limits, pick-up |
(0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz
|
| Switching of motor load |
9A @ 400V, AC-7b per IEC 61095 (50 Hz)
|
| Short time withstand (Icw) |
170A @ 10s, 60 °C
|
| Coil consumption, hold-in |
9.5VA/2.7 W @ 50 Hz, 60 Hz, 50/60 Hz
|
| Coil consumption, pick-up |
75VA @ 50 Hz, 60 Hz, 50/60 Hz
|
| Operating time |
15…30 ms @ AC closing delay
|
| Total power dissipation |
DC control (electronic): 2.4 W @ 400V, AC-3, Ie
|
| Operating limits, dropout |
(0.3...0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz
|
| Switching of lamps |
Gas discharge lA, open: 22.5A @ 40°C (104 °F), AC-5a
|
| Switching of hermetically sealed cooling compressor motors |
8A @ 690V, AC-8a (manual reset of overload release (50 Hz))
|
| Coil insulation class |
Class F per IEC 60085, UL Class 105
|
| Rating for switching AC motors |
3-poles: 7.5Hp @ 575V (AC-2, AC-3, AC-4), 3-phase (60 Hz)
|
| BS88 fuses current rating |
Type 2 (per IEC 60947-4-1): 20A @ 415V, 65 kA available fault current
|
| UL class K5 and RK5 fuses rating |
35A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
|
| UL class CC and CSA HRCI-MISC fuses rating |
20A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14
|
| UL inverse-time circuit breaker |
30 A @ 600Y/347V @ 25kA available fault current per UL 508 and CSA 22.2 No. 14
|
| Rated operational current (Ie) |
9A @ 575V, 3-phase per UL/CSA
|
| Rated operational power (Pe) |
7.5 kW @ 690V, Star-Delta starting (50 Hz)
|
| DIN fuses (gG, gL) current rating |
Type 2 (per IEC 60947-4-1): 25A @ 690V, 50 kA available fault current
|
| UL class J and CSA HRCI-J fuses rating |
20A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14
|
| Switching of power transformers |
Apparent power: 9.4 kVA @ 500V, AC-6a 50 Hz (n = 30)
|
| Switching of 3-phase Capacitors |
Single capacitor: 8 kVAR @ 690V, AC-6b 50 Hz, 60 °C (Inductance of leads between capacitors in parallel: min. 6 µH)
|
| Switching of DC loads |
3-Poles in series: 6A @ 220V (Shunt-wound motors starting, reverse current braking, reversing, stepping DC-3 at 60 °C)
|
| Contacts |
3 power poles with internal NO or NC auxiliary contact or 4 power poles (9...23 A), Optional front-or side mounted 1-2 or 4-pole external auxiliary contact block
|
| Function |
Reversing contactor
|
| Rated impulse voltage withstand (Uimp) |
6 kV
|
| Conventional coil type |
Yes
|
| Electronic-EI coil type |
Yes
|
| Rated coil frequency |
AC 50/60 Hz, DC
|
| Width |
98.6 mm
|
|---|---|
| Height |
80.77 mm
|
| Depth |
84.63 mm
|
| Options |
Empty
|
| Optional overload relays |
Electronic or bimetallic
|
| Optional accessories |
Front or side-mount auxiliary contacts, Surge suppressors, Electronic or pneumatic timers, Mechanical interlocks, Mechanical latches
|
| Features |
Panel mounting or mounting on 35 mm DIN rail, AC or DC coil control, Reversible coil terminals (line or load side), Common accessories, Made of environmentally friendly materials
|
| Recommended torque |
9 in-lb
|
|---|---|
| Vibration resistance |
IEC 60068-2-6
|
| Shock resistance |
IEC 60068-2-27
|
| Coil termination |
Line side connection
|
| Conductor cross section |
Main contacts, 2 conductor: 1…4 mm²
|
| Lifespan |
Mechanical DC control: 13000000 ops
|
| Weight |
1.27 kg (2.81 lbs) reverse @ DC
|
| Type of electrical connection of main circuit |
Screw connection
|
| Auxiliary contacts |
1 NO, 1 NC
|
|---|---|
| Altitude of installation site, max |
2000 m (NN), per IEC60947-1
|
| Protection against accidental contact |
Finger-and back-of-hand proof per VDE0106, part 100
|
| Ambient temperature |
Storage: -55...80 (-67...176)
|
| Protection class auxiliary contact |
IP2X
|
| 图纸 | |
|---|---|
| 3-Dimensional STEP model (STP) | 下载 (ZIP) |
| Product Drawing | Drawing (DXF) |
| 图纸 |
|---|
| 3-Dimensional STEP model (STP) 下载 (ZIP) |
| Product Drawing Drawing (DXF) |
| 类型 | 资源 | 出版 |
|---|---|---|
| Technical Data | 100-td013_-en-p | 100-TD013 |
| 常规 | Product Cutsheet | -- |
- IECEE Scheme
- SUVA LVD Type Approval
- MOROCCO DOC
This product was certified with the above certifications as of 2025-12-23. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
技术规格
| Coil Code |
200-220V 50 Hz / 208-240V 60 H
|
|---|---|
| Maximum Ampere Rating |
9 A
|
| Sub Brand |
IEC
|
| Voltage type for actuating |
AC
|
|---|---|
| Rated control supply voltage at AC 50 Hz |
200 V
|
| Rated control supply voltage at AC 60 Hz |
208 V
|
| Current (Ie), max |
97 A
|
| Switching frequency, max |
250 ops/h
|
| Main current circuit resistance |
2.7 mohm
|
| Cross section per UL/CSA |
16
|
| Rated operational current for contactor at elevator duty (UL/CSA) |
7.8A @ 200V
|
| Rated operational power for contactor at elevator duty (UL/CSA) |
5Hp @ 575V
|
| Rated isolation voltage (Ui) |
690V @ IEC
|
| Rated voltage (Ue) |
690V @ AC, 50/60 Hz
|
| Rated operational power for contactor at wye-delta |
5Hp @ 230V, 60 Hz
|
| Rated filament current |
12A @ 230/240V, AC-5b
|
| Power dissipation |
0.66 W @ 400V, AC-3, Ie
|
| Coil terminal conductor cross section |
1…4 mm² @ 2 conductor
|
| Rated current (enclosed) |
9.8A @ 115V, 1-phase per UL/CSA
|
| Rated power (enclosed) |
7.5Hp @ 575V, 3-phase per UL/CSA
|
| Coil consumption pick-up (avg/peak) |
14/22 W @ DC (electronic-EA)
|
| General purpose current (enclosed) |
25 A per UL/CSA
|
| Capacitance, max |
500 µF @ short-circuit current of 20 kA
|
| Switching of low inductive loads |
32A @ 440V, AC-7a per IEC 61095 (50 Hz)
|
| Operating limits, pick-up |
(0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz
|
| Switching of motor load |
9A @ 400V, AC-7b per IEC 61095 (50 Hz)
|
| Short time withstand (Icw) |
170A @ 10s, 60 °C
|
| Coil consumption, hold-in |
9.5VA/2.7 W @ 50 Hz, 60 Hz, 50/60 Hz
|
| Coil consumption, pick-up |
75VA @ 50 Hz, 60 Hz, 50/60 Hz
|
| Operating time |
15…30 ms @ AC closing delay
|
| Total power dissipation |
DC control (electronic): 2.4 W @ 400V, AC-3, Ie
|
| Operating limits, dropout |
(0.3...0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz
|
| Switching of lamps |
Gas discharge lA, open: 22.5A @ 40°C (104 °F), AC-5a
|
| Switching of hermetically sealed cooling compressor motors |
8A @ 690V, AC-8a (manual reset of overload release (50 Hz))
|
| Coil insulation class |
Class F per IEC 60085, UL Class 105
|
| Rating for switching AC motors |
3-poles: 7.5Hp @ 575V (AC-2, AC-3, AC-4), 3-phase (60 Hz)
|
| BS88 fuses current rating |
Type 2 (per IEC 60947-4-1): 20A @ 415V, 65 kA available fault current
|
| UL class K5 and RK5 fuses rating |
35A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
|
| UL class CC and CSA HRCI-MISC fuses rating |
20A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14
|
| UL inverse-time circuit breaker |
30 A @ 600Y/347V @ 25kA available fault current per UL 508 and CSA 22.2 No. 14
|
| Rated operational current (Ie) |
9A @ 575V, 3-phase per UL/CSA
|
| Rated operational power (Pe) |
7.5 kW @ 690V, Star-Delta starting (50 Hz)
|
| DIN fuses (gG, gL) current rating |
Type 2 (per IEC 60947-4-1): 25A @ 690V, 50 kA available fault current
|
| UL class J and CSA HRCI-J fuses rating |
20A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14
|
| Switching of power transformers |
Apparent power: 9.4 kVA @ 500V, AC-6a 50 Hz (n = 30)
|
| Switching of 3-phase Capacitors |
Single capacitor: 8 kVAR @ 690V, AC-6b 50 Hz, 60 °C (Inductance of leads between capacitors in parallel: min. 6 µH)
|
| Switching of DC loads |
3-Poles in series: 6A @ 220V (Shunt-wound motors starting, reverse current braking, reversing, stepping DC-3 at 60 °C)
|
| Contacts |
3 power poles with internal NO or NC auxiliary contact or 4 power poles (9...23 A), Optional front-or side mounted 1-2 or 4-pole external auxiliary contact block
|
| Function |
Reversing contactor
|
| Rated impulse voltage withstand (Uimp) |
6 kV
|
| Conventional coil type |
Yes
|
| Electronic-EI coil type |
Yes
|
| Rated coil frequency |
AC 50/60 Hz, DC
|
| Width |
98.6 mm
|
|---|---|
| Height |
80.77 mm
|
| Depth |
84.63 mm
|
| Options |
Empty
|
| Optional overload relays |
Electronic or bimetallic
|
| Optional accessories |
Front or side-mount auxiliary contacts, Surge suppressors, Electronic or pneumatic timers, Mechanical interlocks, Mechanical latches
|
| Features |
Panel mounting or mounting on 35 mm DIN rail, AC or DC coil control, Reversible coil terminals (line or load side), Common accessories, Made of environmentally friendly materials
|
| Recommended torque |
9 in-lb
|
|---|---|
| Vibration resistance |
IEC 60068-2-6
|
| Shock resistance |
IEC 60068-2-27
|
| Coil termination |
Line side connection
|
| Conductor cross section |
Main contacts, 2 conductor: 1…4 mm²
|
| Lifespan |
Mechanical DC control: 13000000 ops
|
| Weight |
1.27 kg (2.81 lbs) reverse @ DC
|
| Type of electrical connection of main circuit |
Screw connection
|
| Auxiliary contacts |
1 NO, 1 NC
|
|---|---|
| Altitude of installation site, max |
2000 m (NN), per IEC60947-1
|
| Protection against accidental contact |
Finger-and back-of-hand proof per VDE0106, part 100
|
| Ambient temperature |
Storage: -55...80 (-67...176)
|
| Protection class auxiliary contact |
IP2X
|
图纸
| 图纸 | |
|---|---|
| 3-Dimensional STEP model (STP) | 下载 (ZIP) |
| Product Drawing | Drawing (DXF) |
| 图纸 |
|---|
| 3-Dimensional STEP model (STP) 下载 (ZIP) |
| Product Drawing Drawing (DXF) |
文档
|
100-td013_-en-p
Technical Data
100-TD013 |
|
Product Cutsheet
常规
-- |
| 类型 | 资源 | 出版 |
|---|---|---|
| Technical Data | 100-td013_-en-p | 100-TD013 |
| 常规 | Product Cutsheet | -- |
认证
- IECEE Scheme
- SUVA LVD Type Approval
- MOROCCO DOC
This product was certified with the above certifications as of 2025-12-23. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.